967 resultados para BLOCK POLYMER-SOLUTIONS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymer electrolytes are currently the focus of much attention as potential electrolytes in electrochemical devices such as batteries, display devices and sensors. Generically, solid polymer electrolytes (SPEs) are mixtures of salts with soft polar polymers. SPEs have many advantages including high energy density, no risk of leakage, no issues related to the presence of solvent, wide electrochemical stability windows, simplified processability and light weight. With the goal of developing a new family of environmentally friendly multifunctional biohybrid materials displaying high ionic conductivity we have produced in the present work, flexible films based on different polymers or hybrids incorporating different salts. The polymer electrolytes studied here have been characterized by means of Differential Scanning Calorimetry, Thermogravimetric Analysis, X-ray diffraction, Polarized Optical Microscopy, complex impedance spectroscopy and cyclic voltammetry. An evaluation of the performance of the sample with the highest conductivity as electrolyte in all solid-state ECDs was performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Técnicas de Caracterização e Análise Química

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Sistemas de Informação

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Projeto de investigação integrado de International Master in Sustainable Built Environment

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(dimethylsiloxane) (PDMS) is an organosilicon polymer widely used in the fabrication of microfluidic systems to integrate biochips. In this study, we propose the use of an adapted PDMS mould for the creation of a miniaturized, reusable, reference electrode for in-chip electrochemical measurements. Through its integrated microfluidic system it is possible to replenish internal buffer solutions, unclog critical junctions and treat the electrode’s surface, assuring a long term reuse of the same device. Planar Ag/AgCl reference electrodes were microfabricated over a passivated p-type Silicon Wafer. The PDMS mould, containing an integrated microfluidic system, was fabricated based on patterned SU-8 mould, which includes a lateral horizontal inlet access point. Surface oxidation was used for irreversible permanent bondage between flat surfaces. The final result was planar Ag/AgCl reference electrode with integrated microfluidic that allows for electrochemical analysis in biochips

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large amplitude oscillatory shear (LAOS) coupled with Fourier transform rheology (FTR) was used for the first time to characterize the large deformation behavior of selected bituminous binders at 20 C. Two polymer modified bitumens (PMB) containing recycled EVA and HDPE and two unmodified bitumens were tested with LAOS-FTR. The LAOS-FTR response of all binders was compared at same frequency, at same Deborah number (by tuning the frequency to the relaxation time of each binder) and at same phase shift angle d (by tuning the frequency to the one corresponding to d = 50 in the SAOS response of each sample). In all the approaches, LAOS-FTR results allowed to differentiate between all the nonlinear mechanical characteristics of the tested binders. All binders show LAOS-FTR patterns reminiscent from colloidal dispersions and emulsions. EVA PMB was less prone to strain-induced microstructural changes when compared to HDPE PMB which showed larger values of nonlinear FTR parameters for the range of shear strains tested in LAOS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Estudos da Criança (área de especialização em Intervenção Psicossocial com Crianças, Jovens e Famílias)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the incidence of intraventricular and atrioventricular conduction defects associated with acute myocardial infarction and the degree of in hospital mortality resulting from this condition during the era of thrombolytic therapy. METHODS: Observational study of a cohort of 929 consecutive patients with acute myocardial infarction. Multivariate analysis by logistic regression. Was used. RESULTS: Logistic regression showed a greater incidence of bundle branch block in male sex (odds ratio = 1.87, 95% CI = 1.02-3.42), age over 70 years (odds ratio = 2.31, 95% CI = 1.68-5.00), anterior localization of the infarction (odds ratio = 1.93, 95% CI = 1.03-3.65). There was a greater incidence of complete atrioventricular block in inferior infarcts (odds ratio = 2.59, 95% CI 1.30-5.18) and the presence of cardiogenic shock (odds ratio = 3.90, 95% CI = 1.43-10.65). Use of a thrombolytic agent was associated with a tendency toward a lower occurrence of bundle branch block (odds ratio = 0.68) and a greater occurrence of complete atrioventricular block (odds ratio = 1.44). The presence of bundle branch block (odds ratio = 2.45 95% , CI = 1.14-5.28) and of complete atrioventricular block (odds ratio = 13.59, 95% CI = 5.43-33.98) was associated with a high and independent probability of inhospital death. CONCLUSION: During the current era of thrombolytic therapy and in this population, intraventricular disturbances of electrical conduction and complete atrioventricular block were associated with a high and independent risk of inhospital death during acute myocardial infarction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The case of a 16-year-old patient with atrioventricular tachycardia caused by a single left anterolateral accessory pathway is reported. When the patient underwent radiofrequency ablation, a lesion on the mitral annulus lateral wall produced changes in the retrograde atrial activation pattern determined by that pathway; changes ranged from a delay in depolarization of the annulus posterior portions to full left atrium counterclockwise activation. Such phenomena were probably caused by a block in the isthmus between the annulus and the lower left pulmonary vein ostium. This case illustrates the importance of the mitral-pulmonary isthmus in the process of left atrium activation, an alert to changes induced by its unintentional block during accessory pathway ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PhD in Chemical and Biological Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciência e Engenharia de Polímeros e Compósitos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the clinical, electrocardiographic, and electrophysiologic characteristics of patients (pt) with intra-His bundle block undergoing an electrophysiologic study (EPS). METHODS: We analyzed the characteristics of 16 pt with second-degree atrioventricular block and symptoms of syncope or dyspnea, or both, undergoing conventional EPS. RESULTS: Intra-His bundle block was documented in 16 pt during an EPS. In 15 (94%) pt, the atrioventricular block was recorded in sinus rhythm; 4 (25%) pt had intra-His Wenckebach phenomenon, which correlated with Mobitz I (MI) atrioventricular block on the electrocardiogram. Seven (44%) pt had 2:1 atrioventricular block, 2 of whom were asymptomatic (12.5%). One (6%) pt had intra- and infra-His bundle block. Clinically, 11 (68%) pt had syncope or presyncope, 3 (18%) had dyspnea on exertion, and 2 (12.5%) were asymptomatic. Eight (50%) pt had bundle-branch block as follows: 4 (25%) pt had left bundle-branch block, and 4 (25%) had right bundle-branch block. Left anterosuperior divisional block was observed in 3 pt (19%), 2 of whom with associated right bundle-branch block. CONCLUSION: Intra-His bundle block was observed in 11% of the pt with second-degree atrioventricular block, syncope or presyncope, or both, it being the most frequent clinical presentation. Intra-His bundle block was more common in the elderly (> 60 years) and among females. The most frequent electrocardiographic presentations were second-degree Mobitz I or type 2:1 atrioventricular block.