682 resultados para Toric implantable collamer lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS: Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay). RESULTS: PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case report reports the visual rehabilitation obtained with the fitting of a new design of full scleral contact lens (ICD 16.5 contact lens, Paragon Vision Sciences, distributed by Lenticon, Madrid, Spain) in a cornea with advanced keratoconus and previous implantation of intracorneal ring segment with a very limited effect. This eye had a refraction of –3.00 × 55° cylinder, providing a visual acuity of 0.5 LogMAR. The topographic pattern was very irregular with the presence of a significant central protrusion and a significant central corneal thinning. Some previous unsuccessful fittings have been performed with corneal and corneal-scleral lenses. A comfortable wearing was achieved with a fully scleral contact lens of 4600 μm of sagittal height, optical power of –11.25 D, and providing an apical clearance of 196 μm. A visual acuity of 0.0 LogMAR combined with a relevant aberrometric improvement was achieved with this contact lens. The patient was completely satisfied with the fitting. The result was maintained during 1 year after the fitting. Full scleral lenses are then able to provide comfortable wear and a significant increase in visual acuity combined with a significant improvement in the visual quality in eyes with advanced keratoconus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL) and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP). Materials and Methods: Clinical data from 25 eyes of 14 patients (age range, 52–77 years) and undergoing cataract surgery with implantation of the accommodating IOL Crystalens HD (Bausch and Lomb) were retrospectively reviewed. In all cases, the calculation of an adjusted IOL power (PIOLadj) based on Gaussian optics considering the residual refractive error was done using a variable keratometric index value (nkadj) for corneal power estimation with and without using an estimation algorithm for ELP obtained by multiple regression analysis (ELPadj). PIOLadj was compared to the real IOL power implanted (PIOLReal, calculated with the SRK-T formula) and also to the values estimated by the Haigis, HofferQ, and Holladay I formulas. Results: No statistically significant differences were found between PIOLReal and PIOLadj when ELPadj was used (P = 0.10), with a range of agreement between calculations of 1.23 D. In contrast, PIOLReal was significantly higher when compared to PIOLadj without using ELPadj and also compared to the values estimated by the other formulas. Conclusions: Predictable refractive outcomes can be obtained with the accommodating IOL Crystalens HD using a variable keratometric index for corneal power estimation and by estimating ELP with an algorithm dependent on anatomical factors and age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the visual, refractive, contrast-sensitivity, and aberrometric outcomes during a 1-year follow-up after implantation of a trifocal intraocular lens (IOL). Setting: Premium Clinic, Teplice, Czech Republic. Design: Prospective case series. Methods: This study included eyes of patients having cataract surgery with implantation of the trifocal IOL model AT Lisa tri 839MP. Distance, intermediate (66 and 80 cm), and near (33 and 40 cm) vision; contrast sensitivity; aberrometric outcomes; and the defocus curve were evaluated during a 12-month follow-up. The level of posterior capsule opacification (PCO) was also evaluated. Results: In 120 eyes (60 patients), 1 month postoperatively, an improvement was observed in all visual parameters (P ≤ .03) except corrected near and intermediate visual acuities (both P ≥ .05). From 1 month to 12 months postoperatively, small but statistically significant changes were observed in uncorrected and corrected distance and near visual acuities (all P ≤ .03) and in uncorrected intermediate visual acuity (P = .01). In the defocus curve, no significant differences were found between visual acuities corresponding to defocus levels of −1.0 diopter (D) and −2.0 D (P = .22). The level of ocular spherical aberration decreased statistically significantly at 6 months (P < .001). Ocular and internal higher-order aberrations increased minimally but significantly from 6 to 12 months postoperatively (P < .001). The mean 12-month PCO score was 0.32 ± 0.44 (SD). Four eyes (3.3%) required neodymium:YAG capsulotomy. Conclusion: The trifocal IOL provided complete and stable visual restoration after cataract surgery during a 12-month follow-up, with good levels of visual quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy harvesting devices are widely discussed as an alternative power source for todays active implantable medical devices. Repeated battery replacement procedures can be avoided by extending the implants life span, which is the goal of energy harvesting concepts. This reduces the risk of complications for the patient and may even reduce device size. The continuous and powerful contractions of a human heart ideally qualify as a battery substitute. In particular, devices in close proximity to the heart such as pacemakers, defibrillators or bio signal (ECG) recorders would benefit from this alternative energy source. The clockwork of an automatic wristwatch was used to transform the hearts kinetic energy into electrical energy. In order to qualify as a continuous energy supply for the consuming device, the mechanism needs to demonstrate its harvesting capability under various conditions. Several in-vivo recorded heart motions were used as input of a mathematical model to optimize the clockworks original conversion efficiency with respect to myocardial contractions. The resulting design was implemented and tested during in-vitro and in-vivo experiments, which demonstrated the superior sensitivity of the new design for all tested heart motions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"A quarterly journal of microscopy and the allied natural sciences, with the transactions of the State Microscopical Society of Illinois."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"From the Transactions of the Royal Society of Edinburgh, vol. XXXII, pt. III."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Looking northeast from Michigan Union