969 resultados para Standard setting


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hunhe, Taizihe rivers originating from the east mountain areas of Liaoning Province are the biggest tributaries of the left bank of Liaohe River. From the initial stage of New China to the early 1990s, the frequency of flood damage had decreased, but recently the disasters have upgraded and changed from trunk stream to tributary basins. In July 1995, Dongzhouhe, a tributary of Hunhe River, suffered from a heaviest flood since establishing the document of floods in Hunhe basin. Meanwhile, a peak discharge, almost beyond double defending ability, occurred at Dadongshanpu Station of Beishahe River, a tributary of Taizihe River. Besides the continued heavy rainstorm, no controllable water conservancy projects and ecological damages caused by quickly decreasing forest cover and water and soil loss are the two main causes of flood damage. In addition, the low flood protection standard is also one of causes. According to the above analyses, some strategies of synthetic controlling for flood damages were put forward: 1) Establishing the system of ecological engineering to defend floods and reduce disasters; 2)Setting up storage and detention areas; 3) Establishing flood controlling information system; 4) Improving the accuracy of media short period and short period rainstorm forecast and flood forecast; 5) Insurance of flood protection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nine cases of standard addition methods in instrumental analysis, including linear instruments, a non-linear response, the electrochemical Nernst equation, and radiochemical techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The procedure adopted by the Standard Seawater Service for the calibration of Standard Seawater in electrical conductivity relative to a defined potassium chloride solution is described

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work a nonmonotonic dependence of standard rate constant (k(0)) on reorganization energy (lambda) was discovered qualitatively from electron transfer (Marcus-Hush-Levich) theory for heterogeneous electron transfer processes on electrode surface. It was found that the nonmonotonic dependence of k(0) on lambda is another result, besides the disappearance of the famous Marcus inverted region, coming from the continuum of electronic states in electrode: with the increase of lambda, the states for both Process I and Process II ET processes all vary from nonadiabatic to adiabatic state continuously, and the lambda dependence of k(0) for Process I is monotonic thoroughly, while for Process II on electrode surface the lambda dependence of k(0) could show a nonmonotonicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the analysis of mussel standard reference material by inductively coupled plasma atomic emission spectrometry( ICP-AES) and inductively coupled plasma mass spectrometry(ICP-MS) was developed. K, Na, Ca, Mg, P, Al, Fe, Zn, Mn and Sr were determined by ICP-AES and As, B, Cd, Co, Cr, Cu, Ga, Ge, Mn, Mo, Ni, Pb, Se, Sr, U and V by ICP-MS, The interference coefficients at the Mn-55, Se-78, Cu-63, Co-59, Ni-58, Ni-60, As-75, Se-77, V-51, Cr-53 and Cr-52 originating from polyatomic ion of the matrix elements (KO)-K-39-O-16, K-39(2), (ArNa)-Ar-40-Na-23, (CaO)-Ca-43-O-16, (CaO)-Ca-42-O-16, (CaO)-Ca-44-O-16, (PO2)-P-31-O-16, (ArCl)-Ar-40-Cl-35, (ArCl)-Ar-40-Cl-37, (ClO)-Cl-35-O-16, (ClO)-Cl-37-O-16 and (ArC)-Ar-40-C-12 were determined under the selected operation parameters. The major matrix elements, such as K, Na and Ca, result in the suppression of analytes signals. The apparent concentration at the significant biological element which was produced by the different digestion methods, (.) HNO3 + H2O2 (3 + 2), HNO3 + HClO4 (3 + 0.5) and HNO3 + H2SO4 (3 + 0.5),was determined. The sample digested by HNO3 + H2O2 did not give rise to interfere on the analyte, and the backgrounds of Se-77, Ga-69, Zn-67, As-75, V-51, Cr-53 and Cr-52 were increased by HNO3 + HClO4 digestion method, that affected the determination of these elements, especially the monoisotope As and V. Sample digested by HNO3 + H2SO4 increased the backgrounds at Cu-65, Zn-64 and Zn-67. Detection limits of ICP-AES are 0.001 similar to 0.75 mg/L and those of ICP-MS are 0.005 similar to 1.01 mu g/L. The relative standard derivations of ICP-AES and ICP-MS are 2.7% similar to 12.8%, 3.4% similar to 24.8%, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The steady state voltammogram at a microdisk electrode is used to measure the diffusion coefficient and standard heterogeneous rate constant (k(s)) of ferrocene in polyelectrolyte PEG + LiClO4. The k(s) obtained is smaller in polyelectrolyte than in liquid medium. It is proposed that the polymer solvent electron transfer dynamics are affected by the relaxation rates of the ether dipole sites on the polymer chains, which are in turn constrained by the rates of polymer chain segment, or local structure, relaxations. The dependence of k(s) on temperature is observed. The k(s) increases with increasing temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The emfs of Cu|CuSO_4|Hg_2SO_4-Hg were determined at 5 temperature points from 278.15K to 313.15K. Based on the Pitzer' s Equation a polynomial approximation for the determination of standard emf, E_m, was proposed. The values of E_m obtained by author's method agree with values of E_m obtained by the extended Debye-Huckel equation within experimental errors. Compared with the extrapolation result of extended Debye-Huckel equation, the uncertainty by the selecting of parameter of ion size was avoided.By the...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Terrigenous components were separated from the bulk sediment of Core A7 from the Okinawa Trough and Core A37 from the Ryukru Trench and grain-size distributions of these sub-samples were analyzed. Based upon an analysis of the grain-size data of the two sedimentary sequences, grain-size populations are identified to be sensitive to sedimentary environmental changes. The modal values and size ranges of the two main grain-size populations in Core A7 are evidently different from those of Core A37, indicating the spatial variability of sediment sources and transport processes between the two places. The downcore variations in the content of the environmentally sensitive grain-size populations reveal that during the accumulation of sedimentary material the environment remained relatively stable at the site where Core A7 was collected, except for the apparent events for the formation of two turbidite layers and a volcanic ash layer. However, the sedimentary sequence of Core A37 shows six sedimentary cycles, indicating a highly variable sedimentary environment at this location.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The small mysid crustacean Neomysis awatschensis was collected in the west coast of Jiaozhou Bay, Qingdao, China in 1992 and acclimated and cultured in laboratory conditions since then. Standard acute toxicity tests using 4-6 d juvenile mysids of this species were conducted and the results were compared with Mysidopsis bahia, a standard toxicity test organism used in the US in terms of their sensitivities to reference toxins, as well as their taxonomy, morphology and geographic distributions. Because of its wide distribution along the Chinese coast, similar sensitivity to pollutants as M. bahia, short life history, small size and the case of handling, this study intended to use N. awatschensis as one of the standard marine organisms for toxicity testing in China. The species were applied to acute toxicity evaluations of drilling fluid and its additives I organotin TPT and toxic algae, and to chronic ( life cycle) toxicity assays of organotin TPT and a toxic dinofalgellate Alexandrium tamarense, respectively. Using N, awatschensis as a standard toxicity testing organism in marine pollution assessment in China is suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

根据领域中专用短程通信()协议的基础规范,设计出应用于电子收费系统的物理层、数据链路层和应用层相关参数ITSDSRCDSRC选定和设置。力求在电子收费领域相关的装置与设备能遵循指定的规格标准,并增进各系统相互之间的相容性和互连性。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis mainly studies the technologies of 3-D seismic visualization and Graphic User Interface of seismic processing software. By studying Computer Graphics and 3-D geological modeling, the author designs and implements the visualization module of seismic data processing software using OpenGL and Motif. Setting seismic visualization flow as the subject, NURBS surface approximation and Delaunay Triangulation as the two different methods, the thesis discusses the key algorithms and technologies of seismic visualization and attempts to apply Octree Space Partitioning and Mip Mapping to enhance system performance. According to the research mentioned above, in view of portability and scalability, the author adopts Object-oriented Analysis and Object-oriented Design, uses standard C++ as programming language, OpenGL as 3-D graphics library and Motif as GUI developing tool to implement the seismic visualization framework on SGI Irix platform. This thesis also studies the solution of fluid equations in porous media. 2-D alternating direction implicit procedure has been turned into 3-D successive over relaxation iteration, which possesses such virtues as faster computing speed, faster convergence rate, better adaptability to heterogeneous media and less memory demanding.