964 resultados para Sequential Monte Carlo
Resumo:
Due to the increasing demand from clients and the search for better performances in the heavy vehicles industry, a progressive evolution in technology in a general way was needed. This paper uses a scientific method to validate, prior to its manufacture, the project of an agricultural wheel for sugar cane harvesters. Monte Carlo Simulation is used in conjunction with Finite Elements Method, in order to simulate the wheel's behavior in a cornering test, identify possible failure regions and get an estimate for its life under fatigue. To this end, test conditions according to EUWA Standards were simulated and obeyed, relevant to fatigue. Simulation results were interesting, according to industry experts involved in the project and manufacture of the product in question, and have provided important elements for the decision making regarding improvements that could be made on the product project before its execution
Resumo:
The extrapolation chamber is a parallel-plate ionization chamber that allows variation of its air-cavity volume. In this work, an experimental study and MCNP-4C Monte Carlo code simulations of an ionization chamber designed and constructed at the Calibration Laboratory at IFEN to be used as a secondary dosimetry standard for low-energy X-rays are reported. The results obtained were within the international recommendations, and the simulations showed that the components of the extrapolation chamber may influence its response up to 11.0%. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
In this work, a Monte Carlo code was used to investigate the performance of different x-ray spectra in digital mammography, through a figure of merit (FOM), defined as FOM = CNR2/(D) over bar (g), with CNR being the contrast-to-noise ratio in image and (D) over bar (g) being the average glandular dose. The FOM was studied for breasts with different thicknesses t (2 cm <= t <= 8 cm) and glandular contents (25%, 50% and 75% glandularity). The anode/filter combinations evaluated were those traditionally employed in mammography (Mo/Mo, Mo/Rh, Rh/Rh), and a W anode combined with Al or K-edge filters (Zr, Mo, Rh, Pd, Ag, Cd, Sn), for tube potentials between 22 and 34 kVp. Results show that the W anode combined with K-edge filters provides higher values of FOM for all breast thicknesses investigated. Nevertheless, the most suitable filter and tube potential depend on the breast thickness, and for t >= 6 cm, they also depend on breast glandularity. Particularly for thick and dense breasts, a W anode combined with K-edge filters can greatly improve the digital technique, with the values of FOM up to 200% greater than that obtained with the anode/filter combinations and tube potentials traditionally employed in mammography. For breasts with t < 4 cm, a general good performance was obtained with the W anode combined with 60 mu m of the Mo filter at 24-25 kVp, while 60 mu m of the Pd filter provided a general good performance at 24-26 kVp for t = 4 cm, and at 28-30 and 29-31 kVp for t = 6 and 8 cm, respectively.
Resumo:
Using fixed node diffusion quantum Monte Carlo (FN-DMC) simulations and density functional theory (DFT) within the generalized gradient approximations, we calculate the total energies of the relaxed and unrelaxed neutral, cationic, and anionic aluminum clusters, Al-n (n = 1-13). From the obtained total energies, we extract the ionization potential and electron detachment energy and compare with previous theoretical and experimental results. Our results for the electronic properties from both the FN-DMC and DFT calculations are in reasonably good agreement with the available experimental data. A comparison between the FN-DMC and DFT results reveals that their differences are a few tenths of electron volt for both the ionization potential and the electron detachment energy. We also observe two distinct behaviors in the electron correlation contribution to the total energies from smaller to larger clusters, which could be assigned to the structural transition of the clusters from planar to three-dimensional occurring at n = 4 to 5.
Resumo:
The extension of Boltzmann-Gibbs thermostatistics, proposed by Tsallis, introduces an additional parameter q to the inverse temperature beta. Here, we show that a previously introduced generalized Metropolis dynamics to evolve spin models is not local and does not obey the detailed energy balance. In this dynamics, locality is only retrieved for q = 1, which corresponds to the standard Metropolis algorithm. Nonlocality implies very time-consuming computer calculations, since the energy of the whole system must be reevaluated when a single spin is flipped. To circumvent this costly calculation, we propose a generalized master equation, which gives rise to a local generalized Metropolis dynamics that obeys the detailed energy balance. To compare the different critical values obtained with other generalized dynamics, we perform Monte Carlo simulations in equilibrium for the Ising model. By using short-time nonequilibrium numerical simulations, we also calculate for this model the critical temperature and the static and dynamical critical exponents as functions of q. Even for q not equal 1, we show that suitable time-evolving power laws can be found for each initial condition. Our numerical experiments corroborate the literature results when we use nonlocal dynamics, showing that short-time parameter determination works also in this case. However, the dynamics governed by the new master equation leads to different results for critical temperatures and also the critical exponents affecting universality classes. We further propose a simple algorithm to optimize modeling the time evolution with a power law, considering in a log-log plot two successive refinements.
Resumo:
A detailed characterization of a X-ray Si(Li) detector was performed to obtain the energy dependence of efficiency in the photon energy range of 6.4 - 59.5 keV. which was measured and reproduced by Monte Carlo (MC) simulations. Significant discrepancies between MC and experimental values were found when lhe manufacturer parameters of lhe detector were used in lhe simulation. A complete Computerized Tomagraphy (CT) detector scan allowed to find the correct crystal dimensions and position inside the capsule. The computed efficiencies with the resulting detector model differed with the measured values no more than 10% in most of the energy range.
Resumo:
Doctorado en Análisis Económico. Programa en Análisis Económico Aplicado
Resumo:
Máster Universitario en Sistemas Inteligentes y Aplicaciones Numéricas en Ingeniería (SIANI)
Resumo:
Monte Carlo (MC) simulation techniques are becoming very common in the Medical Physicists community. MC can be used for modeling Single Photon Emission Computed Tomography (SPECT) and for dosimetry calculations. 188Re, is a promising candidate for radiotherapeutic production and understanding the mechanisms of the radioresponse of tumor cells "in vitro" is of crucial importance as a first step before "in vivo" studies. The dosimetry of 188Re, used to target different lines of cancer cells, has been evaluated by the MC code GEANT4. The simulations estimate the average energy deposition/per event in the biological samples. The development of prototypes for medical imaging, based on LaBr3:Ce scintillation crystals coupled with a position sensitive photomultiplier, have been studied using GEANT4 simulations. Having tested, in the simulation, surface treatments different from the one applied to the crystal used in our experimental measurements, we found out that the Energy Resolution (ER) and the Spatial Resolution (SR) could be improved, in principle, by machining in a different way the lateral surfaces of the crystal. We have then studied a system able to acquire both echographic and scintigraphic images to let the medical operator obtain the complete anatomic and functional information for tumor diagnosis. The scintigraphic part of the detector is simulated by GEANT4 and first attempts to reconstruct tomographic images have been made using as method of reconstruction a back-projection standard algorithm. The proposed camera is based on slant collimators and LaBr3:Ce crystals. Within the Field of View (FOV) of the camera, it possible to distinguish point sources located in air at a distance of about 2 cm from each other. In particular conditions of uptake, tumor depth and dimension, the preliminary results show that the Signal to Noise Ratio (SNR) values obtained are higher than the standard detection limit.
Resumo:
Monte Carlo-Simulationen zum kritischen Verhalten dünnerIsing-Filme Dünne Ising-Filme können als vereinfachtes Modell zurBeschreibung von binären Mischungen oder von Flüssigkeitenin schlitzartigen Kapillaren dienen. Infolge dereingeschränkten Geometrie unterscheidet sich das kritischeVerhalten dieser Systeme signifikant von dem einesBulk-Systems, es kommt zu einem Crossover von zwei- zudreidimensionalem kritischen Verhalten. Zusätzlichverschiebt sich der Phasenübergang in den ungesättigtenBereich, ein Effekt, der als 'capillary condensation'bezeichnet wird. In der vorliegenden Arbeit wurden die kritischenEigenschaften von Ising-Filmen im Rahmen einer MonteCarlo-Simulation untersucht. Zur Verbesserung der Effizienzwurde ein Cluster-Algorithmus verwendet, der um einenGhost-Spin-Term zur Behandlung der Magnetfelder erweitertwar. Bei der Datenanalyse kamen moderneMulti-Histogramm-Techniken zur Anwendung. Für alle untersuchten Schichtdicken konnten kritischeTemperatur und Magnetfeld sehr präzise bestimmt werden. DieSkalenhypothese von Fisher und Nakanishi, die dieVerschiebung des kritischen Punktes gegenüber seinesBulk-Wertes beschreibt, wurde sowohl für Systeme mit freienOberflächen als auch für Systeme mit schwachemOberflächenfeld bestätigt. Der Wert des Gap-Exponenten derOberfläche wurde mit $Delta_1$=0.459(13) in Übereinstimmungmit den Literaturwerten abgeschätzt. Die Observablen Magnetisierung und magnetischeSuszeptibilität sowie deren auf die Oberfläche bezogenenEntsprechungen zeigen kein reines zweidimensionaleskritisches Verhalten. Zu ihrer Beschreibung in der Nähe deskritischen Punktes wurden effektive Exponenten für dieeinzelnen Schichtdicken bestimmt.
Resumo:
Oberflächengebundene flüssigkristalline Polymere innematischer Lösung - eine Monte Carlo-Untersuchung In der vorliegenden Arbeit wurde ein System vonoberflächengebundenen flüssigkristallinen Polymeren innematischer Lösung mittels Monte Carlo-Simulationen imNpT-Ensemble untersucht. Dabei wurden die Lösungsmittelteilchen und Polymerteilchen durchweiche abstoßende Ellipsoide des Durchmessers sigma_s undder Länge sigma_l modelliert. Darüber hinaus wirktenzwischen Teilchen innerhalb einer Kette zusätzliche Bondlängen- und Bondwinkelpotentiale. Die Kopfenden der Ketten waren mit ihren Mittelpunkten auf einen kubischen Gitter in der Oberfläche fixiert und wechselwirkten nicht mit den übrigen Teilchen. Für die Simulation kam ein neuartiger 'Configurationalbiased Monte Carlo'-Algorithmus zum Einsatz, mit dem esmöglich war, die Simulation stark zu beschleunigen. Dieswurde erreicht, indem die Bindungen einer Polymerkette entfernt und die ehemaligen Kettenteilchen somit zu Lösungsmittelteilchen werden. Aus den Lösungsmittelteilchen wurde dann durch das Ziehen neuer Bindungen eine neue Kette generiert, über deren Annahme dann eine Metropolisabfrage entschied. In den Simulationen sollte untersucht werden, inwieweit esmöglich ist durch Variation der Pfropfdichte einer auf eineglatte Wand aufgebrachten Polymerbürste die Richtung derOrientierung des sie quellenden Lösungsmittels zu einflussen. Neben Systemen ohne Ketten wurden Systeme mit Pfropfdichtenbis zu sigma = 0.84/sigma_s^2 über mehrere Millionen MonteCarlo-Schritte simuliert. Mit den durchgeführten Simulationen konnte gezeigt werden,daß ein Phasenübergang zwischen einer Phase mit flachentlang den Wänden ausgerichteten Teilchen und einer Phasemit Teilchen, deren Orientierung nicht parallel zur Wand ist, existiert.Dieser Phasenübergang tritt im hier betrachteten System beieiner Pfropfdichte von sigma = 0.13/sigma_s^2 auf. Weiterhin konnte bei hohen Pfropfdichten (sigma >=0.8/sigma_s^2) eine Phase mit einer Ausrichtung derLösungsmittelteilchen senkrecht zur Grundfläche gefundenwerden, obwohl die Ketten auch bei diesen Pfropfdichten nicht senkrecht stehen und die Bürste und das Lösungsmittel entkoppeln.