893 resultados para Solution-processed Photovoltaic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Imazapyr has presented excellent results in controlling coppices in stand reforms of eucalypt forests, despite differences in the efficacy levels. To find out whether these different responses are caused by the genetic variability of the cultivated materials, two experiments were carried out under greenhouse conditions with different imazapyr doses in a hydroponic system in plastic vases containing 2,500 mL solution. The clones IEF-1 (Eucalyptus grandis x Eucalyptus sp. hybrid), GE 463 (E. urophylla x E. grandis), and MN 445 (E. grandis x Eucalyptus sp. hybrid) were used in the first assay, and IEF-1, IEF2 (E. grandis x E. urophylla) x Eucalyptus sp. hybrid) and the clones 129 and 7182 (E. grandis x Eucalyptus sp. hybrids) in the second assay. Thirty days after transplanting the seedlings to a nutritive solution, imazapyr was applied to the solution at doses of 0.00, 0.05, 0.10, 0.20, 0.40, 0.80, 1.60 and 3.20 muL L-1. Clone GE 463 proved to be more tolerant to imazapyr than clones IEF-1 and MN 445 in the first assay; however, in the second, clone 7182 was the most tolerant. Thus, doses should also be differentiated when controlling coppices, according to the cultivated clone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential of three macrophytes, Azolla caroliniana, Salvinia minima, and Lemna gibba was assessed in this study to select plants for use in environmental remediation contaminated with atrazine. Experiments were carried out in a greenhouse over six days in pots containing Hoagland 0.25 strength nutritive solution at the following atrazine concentrations: 0; 0.01; 0.1; 1.0; 10.0 mg L-1. Decrease in biomass accumulation was observed in the three macrophytes, as well as toxic effects evidenced by the symptomatology developed by the plants which caused their deaths. The chlorosis and necrosis allowed to observe in the plants the high sensitivity of the three species to the herbicide. Plants presented low potential for removal of atrazine in solution when exposed to low concentrations of the herbicide. However, at the 10.0 mg L-1 atrazine concentration, L. gibba and A. caroliniana showed potential to remove the herbicide from the solution (0.016 and 0.018 mg atrazine per fresh mass gram, respectively). This fact likely resulted from the processes of atrazine adsorption by the dead material. The percentage of atrazine removed from the solution by the plants decreased when the plants were exposed to high concentrations of the pollutant. Azolla caroliniana, S. minima, and L. gibba were not effective in removing the herbicide from solution. The use of these species to remedy aquatic environments was shown to be limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential of three aquatic macrophytes, Azoll caroliniana, Salvinia minima and Lemna gibba, was evaluated in this work aimed at selection of plants to be used in remediation of environments contaminated by arsenic (As). The experiments were carried out in a greenhouse during six days in pots containing Hoagland solution (¼ ionic strength) at As concentrations of 0.5; 2.5 and 5.0 mg L-1. The three species showed greater As accumulation as the concentration of the metalloid in solution increased. However, a reduction was detected in fresh and dry mass gain when the plants were exposed to high As concentrations. The macrophytes showed differences in efficiency of removal of As in solution. A. caroliniana, S. minima and L. gibba accumulated, on average, 0.130; 0.200; and 1.397 mg mDM-1, respectively, when exposed to 5.0 mg L-1 of As. The macrophytes absorbed a greater quantity of As in solution with low phosphate content. The greater As concentration in L. gibba tissues lowered the chlorophyll and carotenoid contents as shown by the high chlorosis incidence. Lemna gibba also exhibited a decrease in leaf size, with the total chlorophyll and carotenoid synthesis not being affected by As in A. caroliniana. This species exhibited purplish leaves with high concentration of anthocyanin, whose presence suggested association to phosphate deficiency. Marginal necrosis occurred on S. minima floating leaves, with the released daughter-plants not showing any visual symptoms during the treatment. The percentage of As removed from the solution decreased when the plants were exposed to high concentrations of the pollutant. Among the three species studied, only L. gibba could be considered an As hyper-accumulator. The use of this plant species for remediation of aquatic environments was shown to be limited and requires further investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of five adjuvants (non-ionic surfactant, paraffinic oil, vegetable oil, mixture of fatty acids methyl esters plus surfactant blend, and organosilicone) on diquat efficacy was assessed on poverty brome, sterile oat, and Italian ryegrass in field and pot experiments. All tank mixtures with diquat increased diquat efficacy from 50-54% to 77-98% as for fresh weight reduction, indicating significant enhancement of diquat efficacy on grasses. The increased efficacy was most likely attributed to better droplet retention and diffusion on the leaf surfaces. When combined with non-ionic surfactant, diquat showed slightly more rapid control of grass weeds (i.e. symptoms were visible within a few hours after application).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presentation at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presentation at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presentation at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Putkipalkkiliitosten käyttäminen offshore-teollisuuden rakennusten tukirakenteissa on erittäin yleistä. Liitosten valmistaminen on hankalaa ja hidasta. Hyvin usein tukirakenteiden putkipalkkiliitokset joudutaan hitsaamaan manuaalisesti tukirakenteen suuren koon vuoksi. Tukirakenteen uudella valmistustavalla, jossa rakenne kootaan pienemmistä osista, voidaan putkipalkkiliitosten valmistaminen ja hitsaaminen automatisoida. Robottihitsausasema sekä sen käyttöliittymä ja ohjelmisto todettiin toimivaksi ratkaisuksi putkipalkkiliitosten hitsaamiseen. Automaatiosuunnitteluun liittyy monia eri vaiheita, joiden huolellinen läpikäynti takaa todenmukaisemman konseptiratkaisun. Konseptiratkaisu kehittyy samalla, kun laitteistoja ja layoutia muokataan valmiimmiksi. Automaatiosuunnittelun aikana pyritään löytämään oikea taso automaatiolle. Valittu automaation taso vaikuttaa tuotannon tuottavuuteen, läpimenoaikaan ja joustavuuteen. Automaation määrällä vaikutetaan myös ihmisen tekemän työn määrään ja työnkuvaan. Tässä diplomityössä kehitettiin Pemamek Oy:lle hitsausautomaatioratkaisuja putkimaisille kappaleille. Putkiston osia valmistavan tehtaan hitsaus- ja tuotantoautomaation konseptiratkaisua tarkasteltiin esimerkkitapauksen muodossa, jolla kuvattiin, kuinka automaatiojärjestelmä voidaan suunnitella konseptitasolle. Toinen hitsausautomaatioratkaisu, joka tässä työssä kehitettiin, on robottihitsausasema käyttöliittymineen putkipalkkiliitoksen hitsaamiseen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some modifications were made to the methodology of Imai et al. (Jpn. J. Genet. 63: 159-185, 1988) for cytogenetic analysis of the leaf-cutting ants Atta sexdens piriventris and Acromyrmex heyeri (Hymenoptera, Formicidae), shortening preparation time and improving chromosomal preparations. The brain ganglia of prepupae were dissected in a 0.0025% hypotonic solution of colchicine, placed on a glass slide on a cold plate (4 ± 1oC) for 20 min. The material was fixed directly on the cold slide (with cold fixative I), macerated with a histological needle and fixed again with fixative I, followed by fixatives II and III, all of them cold. The slide was flame-dried right after the use of fixative III, and it was allowed to air-dry at room temperature for 2 h. The resulting metaphases presented less contracted chromosomes, with separated and well defined sister chromatids at a high frequency, when the material was processed in the manner described and stained with 3% Giemsa in phosphate buffer (pH 6.8) for 15 min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immunoglobulin G (IgG) of excellent quality for intravenous use was obtained from the cryosupernatant of human plasma by a chromatographic method based on a mixture of ion-exchange, DEAE-Sepharose FF and arginine Sepharose 4B affinity chromatography and a final purification step by Sephacryl S-300 HR gel filtration. The yield of 10 experimental batches produced was 3.5 g IgG per liter of plasma. A solvent/detergent combination of 1% Tri (n-butyl) phosphate and 1% Triton X-100 was used to inactivate lipid-coated viruses. Analysis of the final product (5% liquid IgG) based on the mean for 10 batches showed 94% monomers, 5.5% dimers and 0.5% polymers and aggregates. Anticomplementary activity was 0.3 CH50/mg IgG and prekallikrein activator levels were less than 5 IU/ml. Stability at 37ºC for 30 days in the liquid state was satisfactory. IgG was stored in flasks (2.5 g/flask) at 4 to 8ºC. All the characteristics of the product were consistent with the requirements of the 1997 Pharmacopée Européenne.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parallel-connected photovoltaic inverters are required in large solar plants where it is not economically or technically reasonable to use a single inverter. Currently, parallel inverters require individual isolating transformers to cut the path for the circulating current. In this doctoral dissertation, the problem is approached by attempting to minimize the generated circulating current. The circulating current is a function of the generated common-mode voltages of the parallel inverters and can be minimized by synchronizing the inverters. The synchronization has previously been achieved by a communication link. However, in photovoltaic systems the inverters may be located far apart from each other. Thus, a control free of communication is desired. It is shown in this doctoral dissertation that the circulating current can also be obtained by a common-mode voltage measurement. A control method based on a short-time switching frequency transition is developed and tested with an actual photovoltaic environment of two parallel inverters connected to two 5 kW solar arrays. Controls based on the measurement of the circulating current and the common-mode voltage are generated and tested. A communication-free method of controlling the circulating current between parallelconnected inverters is developed and verified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis focuses on the development of sustainable industrial architectures for bioenergy based on the metaphors of industrial symbiosis and industrial ecosystems, which imply exchange of material and energy side-flows of various industries in order to improve sustainability of those industries on a system level. The studies on industrial symbiosis have been criticised for staying at the level of incremental changes by striving for cycling waste and by-flows of the industries ‘as is’ and leaving the underlying industry structures intact. Moreover, there has been articulated the need for interdisciplinary research on industrial ecosystems as well as the need to extend the management and business perspectives on industrial ecology. This thesis addresses this call by applying a business ecosystem and business model perspective on industrial symbiosis in order to produce knowledge on how industrial ecosystems can be developed that are sustainable environmentally and economically. A case of biogas business is explored and described in four research papers and an extended summary that form this thesis. Since the aim of the research was to produce a normative model for developing sustainable industrial ecosystems, the methodology applied in this research can be characterised as constructive and collaborative. A constructive research mode was required in order to expand the historical knowledge on industrial symbiosis development and business ecosystem development into the knowledge of what should be done, which is crucial for sustainability and the social change it requires. A collaborative research mode was employed through participating in a series of projects devoted to the development of a biogas-for-traffic industrial ecosystem. The results of the study showed that the development of material flow interconnections within industrial symbiosis is inseparable from larger business ecosystem restructuring. This included a shift in the logic of the biogas and traffic fuel industry and a subsequent development of a business ecosystem that would entail the principles of industrial symbiosis and localised energy production and consumption. Since a company perspective has been taken in this thesis, the role of an ecosystem integrator appeared as a crucial means to achieve the required industry restructuring. This, in turn, required the development of a modular and boundary-spanning business model that had a strong focus on establishing collaboration among ecosystem stakeholders and development of multiple local industrial ecosystems as part of business growth. As a result, the designed business model of the ecosystem integrator acquired the necessary flexibility in order to adjust to local conditions, which is crucial for establishing industrial symbiosis. This thesis presents a normative model for the development of a business model required for creating sustainable industrial ecosystems, which contributes to approaches at the policy-makers’ level, proposed earlier. Therefore, this study addresses the call for more research on the business level of industrial ecosystem formation and the implications for the business models of the involved actors. Moreover, the thesis increases the understanding of system innovation and innovation in business ecosystems by explicating how business model innovation can be the trigger for achieving more sustainable industry structures, such as those relying on industrial symbiosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preparative liquid chromatography is one of the most selective separation techniques in the fine chemical, pharmaceutical, and food industries. Several process concepts have been developed and applied for improving the performance of classical batch chromatography. The most powerful approaches include various single-column recycling schemes, counter-current and cross-current multi-column setups, and hybrid processes where chromatography is coupled with other unit operations such as crystallization, chemical reactor, and/or solvent removal unit. To fully utilize the potential of stand-alone and integrated chromatographic processes, efficient methods for selecting the best process alternative as well as optimal operating conditions are needed. In this thesis, a unified method is developed for analysis and design of the following singlecolumn fixed bed processes and corresponding cross-current schemes: (1) batch chromatography, (2) batch chromatography with an integrated solvent removal unit, (3) mixed-recycle steady state recycling chromatography (SSR), and (4) mixed-recycle steady state recycling chromatography with solvent removal from fresh feed, recycle fraction, or column feed (SSR–SR). The method is based on the equilibrium theory of chromatography with an assumption of negligible mass transfer resistance and axial dispersion. The design criteria are given in general, dimensionless form that is formally analogous to that applied widely in the so called triangle theory of counter-current multi-column chromatography. Analytical design equations are derived for binary systems that follow competitive Langmuir adsorption isotherm model. For this purpose, the existing analytic solution of the ideal model of chromatography for binary Langmuir mixtures is completed by deriving missing explicit equations for the height and location of the pure first component shock in the case of a small feed pulse. It is thus shown that the entire chromatographic cycle at the column outlet can be expressed in closed-form. The developed design method allows predicting the feasible range of operating parameters that lead to desired product purities. It can be applied for the calculation of first estimates of optimal operating conditions, the analysis of process robustness, and the early-stage evaluation of different process alternatives. The design method is utilized to analyse the possibility to enhance the performance of conventional SSR chromatography by integrating it with a solvent removal unit. It is shown that the amount of fresh feed processed during a chromatographic cycle and thus the productivity of SSR process can be improved by removing solvent. The maximum solvent removal capacity depends on the location of the solvent removal unit and the physical solvent removal constraints, such as solubility, viscosity, and/or osmotic pressure limits. Usually, the most flexible option is to remove solvent from the column feed. Applicability of the equilibrium design for real, non-ideal separation problems is evaluated by means of numerical simulations. Due to assumption of infinite column efficiency, the developed design method is most applicable for high performance systems where thermodynamic effects are predominant, while significant deviations are observed under highly non-ideal conditions. The findings based on the equilibrium theory are applied to develop a shortcut approach for the design of chromatographic separation processes under strongly non-ideal conditions with significant dispersive effects. The method is based on a simple procedure applied to a single conventional chromatogram. Applicability of the approach for the design of batch and counter-current simulated moving bed processes is evaluated with case studies. It is shown that the shortcut approach works the better the higher the column efficiency and the lower the purity constraints are.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of various hypertonic solutions on the intraventricular conduction, ventricular repolarization and the arrhythmias caused by the intravenous (iv) injection of bupivacaine (6.5 mg/kg) were studied in sodium pentobarbital-anesthetized mongrel dogs. Hypertonic solutions, given iv 5 min before bupivacaine, were 7.5% (w/v) NaCl, 5.4% (w/v) LiCl, 50% (w/v) glucose (2,400 mOsm/l, 5 ml/kg), or 20% (w/v) mannitol (1,200 mOsm/l, 10 ml/kg). Bupivacaine induced severe arrhythmias and ventricular conduction and repolarization disturbances, as reflected by significant increases in QRS complex duration, HV interval, IV interval and monophasic action potential duration, as well as severe hemodynamic impairment. Significant prevention against ventricular electrophysiologic and hemodynamic disturbances and ventricular arrhythmias was observed with 7.5% NaCl (percent increase in QRS complex duration: 164.4 ± 21.8% in the non-pretreated group vs 74.7 ± 14.1% in the pretreated group, P<0.05; percent increase in HV interval: 131.4 ± 16.1% in the non-pretreated group vs 58.2 ± 7.5% in the pretreated group, P<0.05; percent increase in monophasic action potential duration: 22.7 ± 6.8% in the non-pretreated group vs 9.8 ± 6.3% in the pretreated group, P<0.05; percent decrease in cardiac index: -46 ± 6% in the non-pretreated group vs -28 ± 5% in the pretreated group, P<0.05). The other three hypertonic solutions were ineffective. These findings suggest an involvement of sodium ions in the mechanism of hypertonic protection.