A chromatographic method for the production of a human immunoglobulin G solution for intravenous use


Autoria(s): Tanaka,K.; Sawatani,E.; Shigueoka,E.M.; Campos,T.C.X.B.; Nakao,H.C.; Dias,G.A.; Fujita,R.K.; Arashiro,F.
Data(s)

01/11/1998

Resumo

Immunoglobulin G (IgG) of excellent quality for intravenous use was obtained from the cryosupernatant of human plasma by a chromatographic method based on a mixture of ion-exchange, DEAE-Sepharose FF and arginine Sepharose 4B affinity chromatography and a final purification step by Sephacryl S-300 HR gel filtration. The yield of 10 experimental batches produced was 3.5 g IgG per liter of plasma. A solvent/detergent combination of 1% Tri (n-butyl) phosphate and 1% Triton X-100 was used to inactivate lipid-coated viruses. Analysis of the final product (5% liquid IgG) based on the mean for 10 batches showed 94% monomers, 5.5% dimers and 0.5% polymers and aggregates. Anticomplementary activity was 0.3 CH50/mg IgG and prekallikrein activator levels were less than 5 IU/ml. Stability at 37ºC for 30 days in the liquid state was satisfactory. IgG was stored in flasks (2.5 g/flask) at 4 to 8ºC. All the characteristics of the product were consistent with the requirements of the 1997 Pharmacopée Européenne.

Formato

text/html

Identificador

http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X1998001100002

Idioma(s)

en

Publicador

Associação Brasileira de Divulgação Científica

Fonte

Brazilian Journal of Medical and Biological Research v.31 n.11 1998

Palavras-Chave #immunoglobulin G production #hemoderivate production #intravenous gamma globulin production #industrial chromatography #downstream process
Tipo

journal article