937 resultados para Root canals


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increased demand for water placed upon the water resources of St. Lucie County by the expanding agricultural use has brought about hydrologic changes with ensuing problems. This report documents these changes and provides data which are necessary in solving the problems. (PDF has 59 pages)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimentally observed, results are presented for the DCarcplasmajets and theirarc-rootbehaviors generated atreduced gas pressure and without or with an' applied magnetic field. Pure argon, argon -hydrogen or argon-nitrogen mixture is used as the plasma-forming gas. A specially designed copper mirror is constructed and used for better observing the arc-root behavior on the anode surface of the DC non-transferred arcplasma torch. It is shown that for the cases without applied magnetic field, the laminar plasmajets are stable and approximately axisymmetrical. The arc-root attachment on the anode surface is completely diffusive when argon is used as the plasma-forming gas, while the arc-root attachment often becomes constrictive when hydrogen or nitrogen is added into the argon. When an external magnetic field is applied, the arcroot tends to rotate along the anode surface of the non-transferred arcplasma torch.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clarias gariepinus fingerlings were exposed 96 hours under laboratory conditions using static bioassays with continuous aeration to determine acute toxicity of Datura innoxia root extract. The LC sub(50) of the exposed fingerlings was 128.83 mg/L. The fish exhibited loss of balance, respiratory distress and swam erratically just prior to death

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arc root behavior affects the energy transfer and nozzle erosion in an arcjet thruster. To investigate the development of arc root attachment in 1 kW class N2 and H2-N2 arcjet thrusters from the time of ignition to the stably working condition, a kinetic series of end-on view images of the nozzle obtained by a high-speed video camera was analyzed. The addition of hydrogen leads to higher arc voltage levels and the determining factor for the mode of arc root attachment was found to be the nozzle temperature. At lower nozzle temperatures, constricted type attachment with unstable motions of the arc root was observed, while a fully diffused and stable arc root was observed at elevated nozzle temperatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho teve por objetivo quantificar, comparativamente, a área de preenchimento de dois materiais obturadores sólidos, cones de guta-percha (GP) e cones de Resilon (R), no terço apical de incisivos inferiores humanos, ex vivo, obturados pela técnica da onda contínua de condensação. Os espécimes foram submetidos a um protocolo, desde a cirurgia de acesso até o final do preparo químico-mecânico e divididos aleatoriamente em dois grupos, de 21 dentes cada, de acordo com o material utilizado. Não foi utilizado cimento endodôntico em nenhuma das amostras. Após a obturação, as amostras foram seccionadas transversalmente em dois níveis, a 3 e a 5mm do ápice, e subdivididas em grupos de acordo com a altura de corte e do material obturador, sendo estabelecido: GP3 (guta-percha com corte a 3mm), GP5 (guta-percha com corte a 5mm), R3 (Resilon com corte a 3mm) e R5 (Resilon com corte a 5mm). Posteriormente, as amostras foram submetidas a um processo de lixamento e polimento e examinadas em microscópio óptico por reflexão com aumento de 50x a 100x. Para a análise e processamento digital das imagens, foi utilizado o sistema de imagens Axio Vision 4.6 para Windows, sendo obtidas as medidas para cada área observada em micrômetros (μm); uma da área da cavidade, e outra da área de material obturador. Foi aferido o grau de circularidade de cada amostra, por uma fórmula matemática utilizada automaticamente pelo programa, onde 1 (um) é considerado o círculo perfeito e, quanto mais achatado o canal, mais tendente a 0 (zero) nesta escala. Obteve-se a área do canal, a circularidade de 0 a 1, a área preenchida pelo material obturador e, a porcentagem da área de preenchimento do material obturador em relação à área do canal. Foi realizado o cruzamento dos grupos dois a dois pelo teste t de Student, sendo verificada diferença estatisticamente significante entre os grupos GP3 e R3, tendo o grupo R3 apresentado maior porcentagem de área do canal radicular preenchida pelo material obturador em suas amostras (p<0,05). Na relação da circularidade com a quantidade de preenchimento, com o teste de Correlação de Pearson, não foi observada forte correlação entre a forma final do canal (relação de circularidade) e a quantidade de preenchimento do canal radicular pelos materiais obturadores testados. Conclui-se que houve grande variação de preenchimento mínimo e máximo em todos os grupos testados e o Resilon apresentou maior porcentagem de preenchimento de área do canal radicular em suas amostras.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar a espessura mínima radicular remanescente e o desgaste porcentual do terço cervical em raízes mesiais de molares inferiores, após a instrumentação com as técnicas ProTaper Universal e Lima única F2. Foram obtidos 100 primeiros molares inferiores com raízes completamente separadas. Desse total, foram selecionados e incluídos no estudo somente 22 que possuíam dois canais distintos na raiz mesial, comprimento entre 20 e 22 mm e grau de curvatura da raiz mesial com angulação variando entre 10 e 20. Destes, 8 foram eliminados por possuírem uma anatomia muito discrepante, o que limitava o processamento e análise digital das imagens (PADI). Os dentes foram acessados e a patência apical foi realizada em todos os canais determinando o comprimento de trabalho. Em cada dente, cada canal mesial foi instrumentado por uma técnica diferente. As amostras foram posicionadas em um dispositivo de montagem e digitalizadas através de microtomografia computadorizada antes e depois de serem completamente instrumentadas. O volume de interesse, correspondente à região de zona de risco, com uma grande margem de tolerância, tanto em direção apical quanto em direção cervical, foi determinado por 234 fatias, totalizando um comprimento vertical de 3,5 mm, para avaliação quantitativa comparativa. Através de PADI mediu-se, de forma automática, a espessura mínima radicular nos dois canais mesiais, antes e após a instrumentação, para todas as fatias de todos os dentes. A partir destes dados foi calculado o desgaste porcentual. Após o tratamento estatístico das mais de 6500 medidas obtidas, pôde-se concluir que não existiu diferença no desgaste da zona de risco produzido pelas duas técnicas de instrumentação testadas. Em todos os casos a espessura radicular remanescente permaneceu dentro de uma margem de segurança, não havendo, portanto, nenhum caso de rasgo ou perfuração. Dessa forma, ambas as técnicas estudadas foram consideradas seguras quanto ao desgaste da zona de risco da raiz mesial dos molares inferiores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper gives the results of the Environment Agency's research into the canal close season to the Salmon and Freshwater Fisheries Review Group. It presents the findings of the research, explains why the research was undertaken and how it relates to the Agency's duties. The background for this report includes that angling representative bodies have long argued that the existing situation in which somecanals have a close season and others do not, is unsatisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The impact of nano-scaled materials on photosynthetic organisms needs to be evaluated. Plants represent the largest interface between the environment and biosphere, so understanding how nanoparticles affect them is especially relevant for environmental assessments. Nanotoxicology studies in plants allude to quantum size effects and other properties specific of the nano-stage to explain increased toxicity respect to bulk compounds. However, gene expression profiles after exposure to nanoparticles and other sources of environmental stress have not been compared and the impact on plant defence has not been analysed. Results: Arabidopsis plants were exposed to TiO2-nanoparticles, Ag-nanoparticles, and multi-walled carbon nanotubes as well as different sources of biotic (microbial pathogens) or abiotic (saline, drought, or wounding) stresses. Changes in gene expression profiles and plant phenotypic responses were evaluated. Transcriptome analysis shows similarity of expression patterns for all plants exposed to nanoparticles and a low impact on gene expression compared to other stress inducers. Nanoparticle exposure repressed transcriptional responses to microbial pathogens, resulting in increased bacterial colonization during an experimental infection. Inhibition of root hair development and transcriptional patterns characteristic of phosphate starvation response were also observed. The exogenous addition of salicylic acid prevented some nano-specific transcriptional and phenotypic effects, including the reduction in root hair formation and the colonization of distal leaves by bacteria. Conclusions: This study integrates the effect of nanoparticles on gene expression with plant responses to major sources of environmental stress and paves the way to remediate the impact of these potentially damaging compounds through hormonal priming.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo do estudo foi verificar ex vivo a penetração de duas substâncias irrigantes hipoclorito de sódio 5% e Chlor-Xtra (Vista Dental Products, Racine, WI) através da adição de corante em canais simulados de dentes clarificados. Sessenta caninos inferiores unirradiculares humanos foram utilizados. As raízes foram seccionados em 16mm e instrumentadas com limas rotatórias do sistema Protaper até a F2 no comprimento de trabalho de 15mm. As amostras foram submetidas ao processo de clarificação para ficarem transparentes e durante o processo foram criados os canais simulados no terço apical. As raízes foram divididas aleatoriamente em três grupos ( NaOCl 5%, Chlor-Xtra e água) contendo 20 espécime por grupo. As amostras foram irrigadas com 1,5mL de solução contraste( tinta chinesa junto com a solução irrigante do respectivo grupo). E cada amostra foi fotografada e analisada. Os dados foram analisados estatisticamente pelos testes Kruskal-Wallis e Student-Neuman-Keuls. Não houve diferença estatística entre as substâncias irrigantes testadas (p>0,05). A partir da análise dos dados, foi possível concluir que apesar da presença de agentes surfactantes na solução irrigante de Chlor-Xtra não houve uma melhor penetrabilidade nos canais simulados em comparação ao hipoclorito de sódio(NaOCl).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo do presente trabalho foi avaliar, em microtomografia computadorizada (CT), o preparo de canais de molares inferiores com diferentes sistemas acionados a motor. Foram selecionadas 58 raízes mesiais patentes, de diâmetro anatômico correspondente a #10. Para a avaliação em TC, um anel de aço inoxidável foi confeccionado nos moldes do suporte para amostra do microtomógrafo, para que servisse de fôrma para a inclusão das raízes em resina Duralay, a fim de padronizar a posição do espécime no escaneamento inicial e final. Os canais foram preparados com os sistemas Reciproc R25 (n=16); WaveOne Primary File (n=16); Twisted File (n=14), e HyFlex (n=12). Após serem escaneados, foram reconstruídos tridimensionalmente e avaliados quantitativamente quanto à variação de volume (mm3), área de superfície (mm2) e structure model index (SMI). Foi, ainda, realizada a avaliação qualitativa das seções transversais por terço e por quadrante (MV, ML, DV, DL), sendo avaliado o toque de paredes. Os dados paramétricos foram analisados estatisticamente pelos testes ANOVA e t para amostras pareadas (α=5%). Não foi observada diferença estatística nos parâmetros quantitativos avaliados para Reciproc (142,77 76,75; 42,22 19,22; e 14,68 17,69, respectivamente); WaveOne (105,09 64,82; 29,54 19,21; 14,81 9,10, respectivamente); Twisted File (111,83 43,09; 33,31 18,40; 9,16 6,57, respectivamente), e HyFlex (151,74 149,37; 43,08 41,44; 10,80 8,52, respectivamente) (p=0,423). Dentro de cada grupo, foi observada diferença significante entre os resultados pré e pós-operatórios. O teste não paramétrico de Kruskal Wallis foi aplicado para a avaliação relativa ao toque de paredes. Foi observado que o sistema HyFlex apresentou a maior porcentagem de toques (82,3 13,1), seguido por Reciproc (81,3 16,9), Twisted File (78,3 14,4) e, por fim, WaveOne (76,9 21,7) (p>0,05). Em relação aos terços não foi observada diferença significativa (p=0,424). Os resultados da avaliação dos quadrantes intergrupo não demonstraram diferenças, porém indicaram tendência do preparo em direção à parede distal no terço cervical. Ao final, pôde-se concluir que os sistemas testados se equivalem quanto ao preparo de canais mesiais de molares inferiores; porém, nenhuma das técnicas foi capaz de tocar completamente em todas as paredes do canal radicular.