Avaliação do efeito de duas técnicas de instrumentação na zona de risco de molares inferiores curvos por microtomografia computadorizada e análise de imagens


Autoria(s): Karina Andrade Di Giorgi
Contribuinte(s)

Sidnei Paciornik

Sandra Rivera Fidel

Carlos Augusto de Melo Barbosa

Adilia Maria Vieira Bruno

Rivail Antonio Sergio Fidel

Data(s)

25/02/2010

Resumo

O objetivo deste estudo foi avaliar a espessura mínima radicular remanescente e o desgaste porcentual do terço cervical em raízes mesiais de molares inferiores, após a instrumentação com as técnicas ProTaper Universal e Lima única F2. Foram obtidos 100 primeiros molares inferiores com raízes completamente separadas. Desse total, foram selecionados e incluídos no estudo somente 22 que possuíam dois canais distintos na raiz mesial, comprimento entre 20 e 22 mm e grau de curvatura da raiz mesial com angulação variando entre 10 e 20. Destes, 8 foram eliminados por possuírem uma anatomia muito discrepante, o que limitava o processamento e análise digital das imagens (PADI). Os dentes foram acessados e a patência apical foi realizada em todos os canais determinando o comprimento de trabalho. Em cada dente, cada canal mesial foi instrumentado por uma técnica diferente. As amostras foram posicionadas em um dispositivo de montagem e digitalizadas através de microtomografia computadorizada antes e depois de serem completamente instrumentadas. O volume de interesse, correspondente à região de zona de risco, com uma grande margem de tolerância, tanto em direção apical quanto em direção cervical, foi determinado por 234 fatias, totalizando um comprimento vertical de 3,5 mm, para avaliação quantitativa comparativa. Através de PADI mediu-se, de forma automática, a espessura mínima radicular nos dois canais mesiais, antes e após a instrumentação, para todas as fatias de todos os dentes. A partir destes dados foi calculado o desgaste porcentual. Após o tratamento estatístico das mais de 6500 medidas obtidas, pôde-se concluir que não existiu diferença no desgaste da zona de risco produzido pelas duas técnicas de instrumentação testadas. Em todos os casos a espessura radicular remanescente permaneceu dentro de uma margem de segurança, não havendo, portanto, nenhum caso de rasgo ou perfuração. Dessa forma, ambas as técnicas estudadas foram consideradas seguras quanto ao desgaste da zona de risco da raiz mesial dos molares inferiores.

The aim of the present study was to evaluate the minimal remaining root canal thickness and percentage of dentin removed of the cervical third of the mesial roots mandibular molars after instrumentation with the ProTaper Universal and Single File F2 Techniques. From a total of 100 teeth, only 22 were selected and included in the study by having two distinct canals in the mesial root with length between 20 and 22 mm and degree of curvature presenting angle between 10 and 20. Eight specimens were eliminated because they have a very disparate anatomy that limited the digital processing and analysis of the images (PADI). The teeth were accessed and patency was performed in all canals determining the working length. In each tooth, each mesial canal was instrumented by a different technique. The samples were placed in a mounting device and scanned by microcomputed tomography before and after instrumentation. The corresponding volume of interest to the region of the risk zone was determined by 234 slices, with a total vertical length of 3.5 mm, for quantitative comparative evaluation with a high degree of tolerance. The PADI performed the measures automatically of the minimal thickness of root in both mesial canals, before and after instrumentation for all slices of each tooth. From these data, the percentage of dentin removed was calculated. After statistical analysis of more than 6500 measurements, it was concluded that there was no difference in the wear of the risk zone produced by the two instrumentation techniques tested. In all instrumented specimens, the root thickness remained within a security margin, thus, no case of strip perforation was observed. Therefore, both techniques were considered safe to be used in mesial root of mandibular molars.

Formato

PDF

Identificador

http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=3078

Idioma(s)

pt

Publicador

Biblioteca Digital de Teses e Dissertações da UERJ

Direitos

Liberar o conteúdo dos arquivos para acesso público

Palavras-Chave #Endodontia #Instrumentação endodôntica #Zona de risco #ProTaper universal #Técnica da lima única #Microtomografia computadorizada #Análise de imagens #Endodontics #Root canal instrumentation #Risk zone #ProTaper universal #Single file technique #Microcomputed tomography #Image analysis #ENDODONTIA #Canal radicular #Endodontia - Instrumentação #Microtomografia por Raio-X
Tipo

Eletronic Thesis or Dissertation

Tese ou Dissertação Eletrônica