915 resultados para simultaneous inference


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of an electroanalytical method for simultaneous determination of copper and lead ions in sugar cane spirit (cachaca) using carbon paste electrode modified with ascorbic acid and carbon nanotubes (CPE-AaCNT) is described. Squarewave voltammetry (SWV) with anodic stripping was employed, and this technique was optimized with respect to the following parameters: frequency (50 Hz), amplitude (100 mV) and scan increment (9 mV). The analytical curves were linear in the range from 0.0900 to 7.00 mg L-1 for lead and copper. The limits of detection were 48.5 and 23.9 mu g L-1 for lead and copper, respectively. The developed method was applied to the simultaneous determination of copper and lead in five commercial samples of sugar cane spirit. The results were in good agreement with those obtained by F AAS/GF AAS (flame atomic absorption spectrometry/graphite furnace atomic absorption spectrometry) and showed that CPE-AaCNT can be successfully employed in the simultaneous determination of these metals in real sugar cane spirit samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper chronicles a 2-year-old girl who presented with acute leukemia/lymphoma syndrome of the T cell immuno-phenotype. At this time, the cytogenetic analysis of her bone marrow cells showed a reciprocal translocation between the short arm of chromosome 12 and the long arm of chromosome 13, t(12;13)(p13;q14). The immunophenotyping of bone marrow blast cells by flow cytometry revealed a population of cells positive for CD56, CD117, CD45, partial CD33, partial HLA-DR, CD13, CD7, CD2 and CD5. Therefore, a diagnosis of acute leukemia with a mixed T cell/myeloid phenotype was made. The patient had a poor response to classic T cell acute lymphocytic leukemia/lymphoma therapy; thus, her treatment was changed to a myeloid leukemia protocol, which produced a good response. She underwent a successful cord blood transplantation from an unrelated HLA partially matched donor. The coexistence of these two phenotypes prompts questions about the existence of clonal instability, which might influence the choice of therapy. The rarity of the t(12;13)(p13;q14) and the coexistence of T cell/myeloid markers suggest a nonrandom association. To the best of our knowledge, this is the first reported case in which a cell clone bearing a t(12;13)(p13;q14) translocation in a mixed T cell/myeloid lesion was detected. Copyright (C) 2012 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and sensitive analytical method for simultaneous determination of anastrozole, bicalutamide, and tamoxifen as well as their synthetic impurities, anastrozole pentamethyl, bicalutamide 3-fluoro-isomer, and tamoxifen e-isomer, was developed and validated by using high performance liquid chromatography (HPLC). The separation was achieved on a Symmetry (R) C-8 column (100 x 4.6 mm i.d., 3.5 mu m) at room temperature (+/- 24 degrees C), with a mobile phase consisting of acetonitrile/water containing 0.18% N,N dimethyloctylamine and pH adjusted to 3.0 with orthophosphoric acid (46.5/53.5, v/v) at a flow rate of 1.0 mL min(-1) within 20 min. The detection was made at a wavelength of 270 nm by using ultraviolet (UV) detector. No interference peaks from excipients and relative retention time indicated the specificity of the method. The calibration curve showed correlation coefficients (r) > 0.99 calculated by linear regression and analysis of variance (ANOVA). The limit of detection (LOD) and limit of quantitation (LOQ), respectively, were 2.2 and 6.7 mu g mL(-1) for anastrozole, 2.61 and 8.72 mu g mL(-1) for bicalutamide, 2.0 and 6.7 mu g mL(-1) for tamoxifen, 0.06 and 0.22 mu g mL(-1) for anastrozole pentamethyl, 0.02 and 0.07 mu g mL(-1) for bicalutamide 3-fluoro-isomer, and 0.002 and 0.007 mu g mL(-1) for tamoxifen e-isomer. Intraday and interday relative standard deviations (RSDs) were <2.0% (drugs) and <10% (degradation products) as well as the comparison between two different analysts, which were calculated by f test. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method using Liquid Phase Microextraction for simultaneous detection of citalopram (CIT), paroxetine (PAR) and fluoxetine (FLU), using venlafaxine as internal standard, in plasma by high performance liquid chromatography with fluorescence detection was developed. The linearity was evaluated between 5.0 and 500 ng mL(-1) (r > 0.99) and the limit of quantification was 2.0, 3.0 and 5.0 ng mL-1 for CIT. PAR and FLU, respectively. Therefore, it can be applied to therapeutic drug monitoring, pharmacokinetics or bioavailability studies and its advantages are that it necessary relatively inexpensive equipment and sample preparation techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lychnophora salicifolia Mart., which occurs in the Brazilian Cerrado in the states of Bahia and Minas Gerais as well as in the southeast of the state of Goias, is the most widely distributed and also the most polymorphic species of the genus. This plant is popularly known to have anti-inflammatory and analgesic activities. In this work, we have studied the variation in terms of polar metabolites of ninety-three Lychnophora salicifolia Mart, specimens collected from different regions of the Brazilian Cerrado. Identification of the constituents of this mixture was carried out by analysis of the UV spectra and MS data after chromatographic separation. Twenty substances were identified, including chlorogenic acid derivatives, a flavonoid C-glucoside, and other sesquiterpenes. The analytical method was validated, and the reliability and credibility of the results was ensured for the purposes of this study. The concentration range required for analysis of content variability within the analyzed group of specimens was covered with appropriate values of limits of detection and quantitation, as well as satisfactory precision and recovery. A quantitative variability was observed among specimens collected from the same location, but on average they were similar from a chemical viewpoint. In relation to the study involving specimens from different locations, there were both qualitative and quantitative differences among plants collected from different regions of Brazil. Statistical analysis revealed that there is a correlation between geographical localization and polar metabolites profile for specimens collected from different locations. This is evidence that the pattern of metabolites concentration depends on the geographical distribution of the specimens. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We extend the random permutation model to obtain the best linear unbiased estimator of a finite population mean accounting for auxiliary variables under simple random sampling without replacement (SRS) or stratified SRS. The proposed method provides a systematic design-based justification for well-known results involving common estimators derived under minimal assumptions that do not require specification of a functional relationship between the response and the auxiliary variables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, a fast, sensitive and robust method to quantify dextromethorphan, dextrorphan and doxylamine in human plasma using deuterated internal standards (IS) is described. The analytes and the IS were extracted from plasma by a liquid-liquid extraction (LLE) using diethyl-ether/hexane (80/20, v/v). Extracted samples were analyzed by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Chromatographic separation was performed by pumping the mobile phase (acetonitrile/water/formic acid (90/9/1, v/v/v) during 4.0 min at a flow-rate of 1.5 mL min(-1) into a Phenomenex Gemini (R) C18, 5 mu m analytical column (150 x 4.6 mm id.). The calibration curve was linear over the range from 0.2 to 200 ng mL(-1) for dextromethorphan and doxylamine and 0.05 to 10 ng mL(-1) for dextrorphan. The intra-batch precision and accuracy (%CV) of the method ranged from 2.5 to 9.5%, and 88.9 to 105.1%, respectively. Method inter-batch precision (%CV) and accuracy ranged from 6.7 to 10.3%, and 92.2 to 107.1%, respectively. The run-time was for 4 min. The analytical procedure herein described was used to assess the pharmacokinetics of dextromethorphan, dextrorphan and doxylamine in healthy volunteers after a single oral dose of a formulation containing 30 mg of dextromethorphan hydrobromide and 12.5 mg of doxylamine succinate. The method has high sensitivity, specificity and allows high throughput analysis required for a pharmacokinetic study. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Arboviral diseases are major global public health threats. Yet, our understanding of infection risk factors is, with a few exceptions, considerably limited. A crucial shortcoming is the widespread use of analytical methods generally not suited for observational data - particularly null hypothesis-testing (NHT) and step-wise regression (SWR). Using Mayaro virus (MAYV) as a case study, here we compare information theory-based multimodel inference (MMI) with conventional analyses for arboviral infection risk factor assessment. Methodology/Principal Findings: A cross-sectional survey of anti-MAYV antibodies revealed 44% prevalence (n = 270 subjects) in a central Amazon rural settlement. NHT suggested that residents of village-like household clusters and those using closed toilet/latrines were at higher risk, while living in non-village-like areas, using bednets, and owning fowl, pigs or dogs were protective. The "minimum adequate" SWR model retained only residence area and bednet use. Using MMI, we identified relevant covariates, quantified their relative importance, and estimated effect-sizes (beta +/- SE) on which to base inference. Residence area (beta(Village) = 2.93 +/- 0.41; beta(Upland) = -0.56 +/- 0.33, beta(Riverbanks) = -2.37 +/- 0.55) and bednet use (beta = -0.95 +/- 0.28) were the most important factors, followed by crop-plot ownership (beta = 0.39 +/- 0.22) and regular use of a closed toilet/latrine (beta = 0.19 +/- 0.13); domestic animals had insignificant protective effects and were relatively unimportant. The SWR model ranked fifth among the 128 models in the final MMI set. Conclusions/Significance: Our analyses illustrate how MMI can enhance inference on infection risk factors when compared with NHT or SWR. MMI indicates that forest crop-plot workers are likely exposed to typical MAYV cycles maintained by diurnal, forest dwelling vectors; however, MAYV might also be circulating in nocturnal, domestic-peridomestic cycles in village-like areas. This suggests either a vector shift (synanthropic mosquitoes vectoring MAYV) or a habitat/habits shift (classical MAYV vectors adapting to densely populated landscapes and nocturnal biting); any such ecological/adaptive novelty could increase the likelihood of MAYV emergence in Amazonia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Manaus, the capital city of the state of Amazon with nearly 2 million inhabitants, is located in the middle of the Amazon rain forest and has suffered dengue outbreaks since 1998. Methods: In this study, blood samples were investigated using reverse transcriptase-polymerase chain reaction (RT-PCR), aimed at identifying dengue virus serotypes. Results: Acute phase sera from 432 patients were tested for the presence of dengue virus. Out of the 432 patients, 137 (31.3%) were found to be positive. All the four dengue virus serotypes were observed. Conclusions: The simultaneous circulation of the four dengue serotypes is described for the first time in Manaus and in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a simultaneous optical signal-to-noise ratio (OSNR) and differential group delay (DGD) monitoring method based on degree of polarization (DOP) measurements in optical communications systems. For the first time in the literature (to our best knowledge), the proposed scheme is demonstrated to be able to independently and simultaneously extract OSNR and DGD values from the DOP measurements. This is possible because the OSNR is related to maximum DOP, while DGD is related to the ratio between the maximum and minimum values of DOP. We experimentally measured OSNR and DGD in the ranges from 10 to 30 dB and 0 to 90 ps for a 10 Gb/s non-return-to-zero signal. A theoretical analysis of DOP accuracy needed to measure low values of DGD and high OSNRs is carried out, showing that current polarimeter technology is capable of yielding an OSNR measurement within 1 dB accuracy, for OSNR values up to 34 dB, while DGD error is limited to 1.5% for DGD values above 10 ps. For the first time to our knowledge, the technique was demonstrated to accurately measure first-order polarization mode dispersion (PMD) in the presence of a high value of second-order PMD (as high as 2071 ps(2)). (C) 2012 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the simultaneous quantification of lycopene, beta-carotene, retinol and alpha-tocopherol by high-performance liquid chromatography (HPLC) with Vis/fluorescence detection with isocratic elution was optimized and validated. The method consists of a rapid and simple liquid-liquid extraction procedure and a posterior quantification of extracted supernatants by HPLC. Aliquots of plasma were stored at -20 degrees C for three months for stability study. The methodology was applied to samples from painters and individuals not exposed to paints (n = 75). The assay was linear for all vitamins (r > 0.99). Intra-and inter-run precisions were obtained with coefficient of variation smaller than 5%. The accuracies ranged from 0.29 to -5.80% and recoveries between 92.73 and 101.97%. Plasma samples and extracted supernatants were stable for 60 days at -20 degrees C. A significant decrease of lycopene, beta-carotene and retinol concentrations in plasma from exposed individuals compared to non-exposed individuals (p < 0.05) was observed. The method is simple, reproducible, precise, accurate and sensitive, and can be routinely utilized in clinical laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims. We report on simultaneous observations and modeling of mid-infrared (MIR), near-infrared (NIR), and submillimeter (sub-mm) emission of the source Sgr A * associated with the supermassive black hole at the center of our Galaxy. Our goal was to monitor the activity of Sgr A* at different wavelengths in order to constrain the emitting processes and gain insight into the nature of the close environment of Sgr A*. Methods. We used the MIR instrument VISIR in the BURST imaging mode, the adaptive optics assisted NIR camera NACO, and the sub-mm antenna APEX to monitor Sgr A* over several nights in July 2007. Results. The observations reveal remarkable variability in the NIR and sub-mm during the five nights of observation. No source was detected in the MIR, but we derived the lowest upper limit for a flare at 8.59 mu m (22.4 mJy with A(8.59 mu m) = 1.6 +/- 0.5). This observational constraint makes us discard the observed NIR emission as coming from a thermal component emitting at sub-mm frequencies. Moreover, comparison of the sub-mm and NIR variability shows that the highest NIR fluxes (flares) are coincident with the lowest sub-mm levels of our five-night campaign involving three flares. We explain this behavior by a loss of electrons to the system and/or by a decrease in the magnetic field, as might conceivably occur in scenarios involving fast outflows and/or magnetic reconnection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the preparation of platinum nanoparticles (PtNPs) using the 3-n-propylpyridinium silsesquioxane chloride (SiPy+Cl-) as a nanoreactor and stabilizer. The formation of PtNPs was monitored by UV-Vis spectroscopy by measuring the decrease in the intensity of the band at 375 nm, which is attributed to the electronic absorption of PtCl62- ions. TEM images of Pt-SiPy+Cl- nanohybrid indicated an average size of 3-40 nm for PtNPs. The Pt-SiPy+Cl- was used as a polycation in the preparation of layer-by-layer films (LbL) on a glass substrate coated with fluorine-doped tin oxide (FTO) alternating with the polyanion poly(vinyl sulfonic acid) (PVS). The films were electrochemically tested in sulfuric acid to confirm the deposition of Pt-SiPy+Cl- onto the LbL films, observing the adsorption and desorption of hydrogen (E-pa = 0.1 V) and by the redox process of formation for PtO with E-pa = 1.3 V and E-pc = 0.65 V. FTIR and Raman spectra confirmed the presence of the PVS and Pt-SiPy+Cl- in the LbL films. A linear increase in the absorbance in the UV-Vis spectra of the Pt-SiPy+Cl- at 258 nm (pi -> pi* transition of the pyridine groups) with a number of Pt-SiPy+Cl-/PVS or PVS/SiPy+Cl- bilayers (R = 0.992) was observed. These LbL films were tested for the determination of dopamine (DA) in the presence of ascorbic acid (AA) with a detection limit (DL) on the order of 2.6 x 10(-6) mol L-1 and a quantification limit (QL) of 8.6 x 10(-6) mol L-1. The films exhibited a good repeatability and reproducibility, providing a potential difference of 550 mV for the oxidation of DA with AA interferent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is no consensus regarding the accuracy of bioimpedance for the determination of body composition in older persons. This study aimed to compare the assessment of lean body mass of healthy older volunteers obtained by the deuterium dilution method (reference) with those obtained by two frequently used bioelectrical impedance formulas and one formula specifically developed for a Latin-American population. A cross-sectional study. Twenty one volunteers were studied, 12 women, with mean age 72 +/- 6.7 years. Urban community, Ribeiro Preto, Brazil. Fat free mass was determined, simultaneously, by the deuterium dilution method and bioelectrical impedance; results were compared. In bioelectrical impedance, body composition was calculated by the formulas of Deuremberg, Lukaski and Bolonchuck and Valencia et al. Lean body mass of the studied volunteers, as determined by bioelectrical impedance was 37.8 +/- 9.2 kg by the application of the Lukaski e Bolonchuk formula, 37.4 +/- 9.3 kg (Deuremberg) and 43.2 +/- 8.9 kg (Valencia et. al.). The results were significantly correlated to those obtained by the deuterium dilution method (41.6 +/- 9.3 Kg), with r=0.963, 0.932 and 0.971, respectively. Lean body mass obtained by the Valencia formula was the most accurate. In this study, lean body mass of older persons obtained by the bioelectrical impedance method showed good correlation with the values obtained by the deuterium dilution method. The formula of Valencia et al., developed for a Latin-American population, showed the best accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to determine the effect of sequence of insemination after simultaneous thawing of multiple 0.5 mL semen straws on conception rate in suckled multiparous Nelore cows. The effect of this thawing procedure on in vitro sperm characteristics was also evaluated. All cows (N = 944) received the same timed AI protocol. Ten straws (0.5 mL) of frozen semen from the same batch were simultaneously thawed at 36 degrees C, for a minimum of 30 sec. One straw per cow was used for timed AI. Frozen semen from three Angus bulls was used. Timed AI records included sequence of insemination (first to tenth) and time of semen removal from thawing bath. For laboratory analyses, the same semen batches used in the field experiment were evaluated. Ten frozen straws from the same batch were thawed simultaneously in a thawing unit identical to that used in the field experiment. The following sperm characteristics were analyzed: sperm motility parameters, sperm thermal resistance, plasma and acrosomal membrane integrity, lipid peroxidation, chromatin structure, and sperm morphometry. Based on logistic regression, there were no significant effects of breeding group, body condition score, AI technician, and sire on conception rate, but there was an interaction between sire and straw group (P = 0.002). Semen from only one bull had decreased (P < 0.05) field fertility for the group of straws associated with the longest interval from thawing to AI. However, the results of the laboratory experiment were unable to explain the findings of the field experiment. Sperm width:length ratio of morphometric analysis was the single sperm characteristic with a significant interaction between sire and straw group (P = 0.02). It was concluded that sequence of insemination after simultaneous thawing of 10 semen straws can differently affect conception rates at timed AI, depending on the sire used. Nevertheless, the effects of this thawing environment on in vitro sperm characteristics, remain to be further investigated. (C) 2012 Elsevier Inc. All rights reserved.