953 resultados para interpersonal reproducibility


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho apresentado em XIII Congreso Internacional Galego-Portugués de Psicopedagoxía, Área 5 Familia, Escuela y Comunidad. Universidad da Coruña, 2 de Setembro de 2015.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho apresentado em XIII Congreso Internacional Galego-Portugués de Psicopedagoxía, Área 8 Interculturalidad, inclusión social y educación. Universidad da Coruña, 3 de Setembro de 2015.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado, Ciências Económicas e Empresariais, 16 de Dezembro de 2015, Universidade dos Açores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the business world, employees can contribute with information, ideas, concerns, opinions and proposals to their managers in respect of: (1) the way work could be performed, (2) what should / should not be done in the workplace, (3) how a particular decision can be implemented, and (4) how an organizational policy should be formed and executed (Rego, 2013). However, due to a diverse set of factors, employees often choose to remain silent in the workplace. One of these factors is psychological safety, which describes employees’ perceptions of the consequences of taking interpersonal risks in the workplace (Edmondson, 2014). The following paper is essentially a literature review and its aim is to, firstly, make a brief approach to factors reported in the literature that may affect employee voice and silence, followed up by an explanation of the types of silence that can be engaged by employees. Besides that, the authors will also make an approach to physical and psychological safety. Lastly, it will be reported some links, mentioned in the literature, between employee silence and psychological safety.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – Os estudos Gated – Single Photon Emission Computed Tomography (SPECT) são uma das técnicas de imagiologia cardíaca que mais evoluiu nas últimas décadas. Para a análise das imagens obtidas, a utilização de softwares de quantificação leva a um aumento da reprodutibilidade e exatidão das interpretações. O objetivo deste estudo consiste em avaliar, em estudos Gated-SPECT, a variabilidade intra e interoperador de parâmetros quantitativos de função e perfusão do miocárdio, obtidos com os softwares Quantitative Gated SPECT (QGS) e Quantitative Perfusion SPECT (QPS). Material e métodos – Recorreu-se a uma amostra não probabilística por conveniência de 52 pacientes, que realizaram estudos Gated-SPECT do miocárdio por razões clínicas e que integravam a base de dados da estação de processamento da Xeleris da ESTeSL. Os cinquenta e dois estudos foram divididos em dois grupos distintos: Grupo I (GI) de 17 pacientes com imagens com perfusão do miocárdio normal; Grupo II (GII) de 35 pacientes que apresentavam defeito de perfusão nas imagens Gated-SPECT. Todos os estudos foram processados 5 vezes por 4 operadores independentes (com experiência de 3 anos em Serviços de Medicina Nuclear com casuística média de 15 exames/semana de estudos Gated-SPECT). Para a avaliação da variabilidade intra e interoperador foi utilizado o teste estatístico de Friedman, considerando α=0,01. Resultados e discussão – Para todos os parâmetros avaliados, os respectivos valores de p não traduziram diferenças estatisticamente significativas (p>α). Assim, não foi verificada variabilidade intra ou interoperador significativa no processamento dos estudos Gated-SPECT do miocárdio. Conclusão – Os softwares QGS e QPS são reprodutíveis na quantificação dos parâmetros de função e perfusão avaliados, não existindo variabilidade introduzida pelo operador.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To translate the Need for Recovery Scale (NFR) into Brazilian Portuguese and culturally adapt it and assess the stability, internal consistency and convergent validity of the Brazilian scale among industrial workers. METHODS: The translation process followed the guidelines for cultural adaptation of questionnaires including the steps of translation, synthesis, back translation, expert committee review, and pre-testing. The Brazilian Portuguese NFR, final version (Br-NFR) was assessed for stability (n=52) and internal consistency (n=192) and for convergent validity through simultaneous assessment with other instruments: the Borg Scale (n=59); the Chalder Fatigue Questionnaire (n=57) and 3 subscales of the SF-36 (n=56). RESULTS: Stability and internal consistency met the criterion for a reliable measure (ICC=0.80 and Cronbach's alpha =0.87, respectively). The convergent validity between Br-NFR and other instruments also showed good results: Borg Scale (r= 0.64); Chalder Questionnaire (r= 0.67); SF-36 subscales: vitality (r= -0.84), physical functioning (r= -0.54), and role-physical (r= -0.47). CONCLUSIONS: The Br-NFR proved to be a reliable instrument to evaluate work-related fatigue symptoms in industrial workers. Furthermore, it showed significant and good correlations with well-established instruments such as the Borg Scale, the Chalder Questionnaire and SF-36 vitality subscale, supporting the validity of the Br-NFR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ian McEwan‘s novel Saturday deals with the complex issues of conflict and transformation in the age of terrorism. The plot presents one internal dilemma and several interpersonal altercations that occur within a mere twenty-four hours: a) Perowne (the protagonist) vs. himself, in face of his ambivalent thoughts regarding British military participation in the war in the Middle East; b) The protagonist vs. Baxter, a ruffian from East End, in the context of a car accident; c) Perowne vs. a fellow anaesthetist, Jay Strauss, during a squash game; d) Perowne‘s daughter, Daisy vs. her grandfather, John Grammaticus, both poets and rivals; e) Perowne‘s family vs. Baxter, who intrudes the protagonist‘s house. In this paper, I exemplify, analyse and discuss how: a) Understanding the causes of what we call evil constitutes an important step towards mutual understanding; b) Both science and arts (which Perowne considers, at first, irrelevant) are important elements in the process of transformation; c) Both personal and interpersonal conflicts are intrinsic to human nature — but they also propitiate healthy changes in behaviour and opinion, through reflection. In order to do so, I resort to Saturday, and to the work of several specialists in the field of conflict management.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze reliability of a self-applied questionnaire on substance use and misuse among adolescent students. METHODS: Two cross-sectional studies were carried out for the instrument test-retest. The sample comprised male and female students aged 1119 years from public and private schools (elementary, middle, and high school students) in the city of Salvador, Northeastern Brazil, in 2006. A total of 591 questionnaires were applied in the test and 467 in the retest. Descriptive statistics, the Kappa index, Cronbach's alpha and intraclass correlation were estimated. RESULTS: The prevalence of substance use/misuse was similar in both test and retest. Sociodemographic variables showed a "moderate" to "almost perfect" agreement for the Kappa index, and a "satisfactory" (>0.75) consistency for Cronbach's alpha and intraclass correlation. The age which psychoactive substances (tobacco, alcohol, and cannabis) were first used and chronological age were similar in both studies. Test-retest reliability was found to be a good indicator of students' age of initiation and their patterns of substance use. CONCLUSIONS: The questionnaire reliability was found to be satisfactory in the population studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method for the determination of some pesticide residues in must and wine samples was developed using solid-phase microextraction (SPME) and gas chromatography – electron capture detection (GC/ECD). The procedure only needs dilution as sample pre-treatment and is therefore simple, fast and solvent-free. Eight fungicides (vinclozolin, procymidone, iprodione, penconazole, fenarimol, folpet, nuarimol and hexaconazole), one insecticide (chlorpyriphos) and two acaricides (bromopropylate and tetradifon) can be quantified. Good linearity was observed for all the compounds in the range 5–100 µg/L. The reproducibility of the measurements was found acceptable (with RSD’s below 20%). Detection limits of 11 µg/L, on average, are sufficiently below the proposed maximum residue limits (MRL’s) for these compounds in wine. The analytical method was applied to the determination of these compounds in Portuguese must and wine samples from the Demarcated Region of Alentejo, where any residues could be detected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Few analytical methods are currently available for determination of apomorphine, the active substance of a new oral formulation used in the treatment of erectile dysfunction. In this way a flow injection electrochemical method (FIA-EC) was developed for its quantification and applied to pharmaceutical dosage forms. Based in previous findings regarding the stability of apomorphine in borate buffer and after optimization of several analytical parameters a single channel flow injection manifold was set up that enables the determination of this drug over the concentration range of 3 to 16 µmol L-1 with a detection limit of 0.5 µmol L-1 at a sampling rateof 90 h-1. The simplicity and rapidity of the FIA-EC method used, its reproducibility and sensitivity make it suitable for quality control of pharmaceutical preparations of apomorphine intended for clinical use and research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

23rd SPACE AGM and Conference from 9 to 12 May 2012 Conference theme: The Role of Professional Higher Education: Responsibility and Reflection Venue: Mikkeli University of Applied Sciences, Mikkeli, Finland

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new flow-injection analytical procedure is proposed for the determination of the total amount of polyphenols in wines; the method is based on the formation of a colored complex between 4-aminoantipyrine and phenols, in the presence of an oxidizing reagent. The oxidizing agents hexacyanoferrate(III), peroxodisulfate, and tetroxoiodate(VII) were tested. Batch trials were first performed to select appropriate oxidizing agents, pH, and concentration ratios of reagents, on the basis of their effect on the stability of the colored complex. Conditions selected as a result of these trials were implemented in a flow-injection analytical system in which the influence of injection volume, flow rate, and reaction- coil length, was evaluated. Under the optimum conditions the total amount of polyphenols, expressed as gallic acid, could be determined within a concentration range of 36 to 544 mg L–1, and with a sensitivity of 344 L mol–1 cm–1 and an RSD <1.1%. The reproducibility of analytical readings was indicative of standard deviations <2%. Interference from sugars, tartaric acid, ascorbic acid, methanol, ammonium sulfate, and potassium chloride was negligible. The proposed system was applied to the determination of total polyphenols in red wines, and enabled analysis of approximately 55 samples h–1. Results were usually precise and accurate; the RSD was <3.9% and relative errors, by the Folin–Ciocalteu method, <5.1%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relatório de Estágio apresentado à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ensino do 1.º e 2.º Ciclo do Ensino Básico

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Enrofloxacin (ENR) is an antimicrobial used both in humans and in food producing species. Its control is required in farmed species and their surroundings in order to reduce the prevalence of antibiotic resistant bacteria. Thus, a new biomimetic sensor enrofloxacin is presented. An artificial host was imprinted in specific polymers. These were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. The potentiometric sensors exhibited a near-Nernstian response. Slopes expressing mVΔlog([ENR]/M) varied within 48–63. The detection limits ranged from 0.28 to 1.01 µg mL 1. Sensors were independent from the pH of test solutions within 4–7. Good selectivity was observed toward potassium, calcium, barium, magnesium, glycine, ascorbic acid, creatinine, norfloxacin, ciprofloxacin, and tetracycline. In flowing media, the biomimetic sensors presented good reproducibility (RSD of ±0.7%), fast response, good sensitivity (47 mV/Dlog([ENR]/ M), wide linear range (1.0×10-5–1.0×10-3 M), low detection limit (0.9 µg mL-1), and a stable baseline for a 5×10-2 M acetate buffer (pH 4.7) carrier. The sensors were used to analyze fish samples. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in vivo measurements of enrofloxacin or parent-drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel biomimetic sensor for the potentiometric transduction of oxytetracycline is presented. The artificial host was imprinted in methacrylic acid and/or acrylamide based polymers. Different amounts of molecularly imprinted and non-imprinted polymers were dispersed in different plasticizing solvents and entrapped in a poly(vinyl chloride) matrix. Only molecularly imprinted based sensors allowed a potentiometric transduction, suggesting the existence of host–guest interactions. These sensors exhibited a near-Nernstian response in steady state evaluations; slopes and detection limits ranged 42–63 mV/decade and 2.5–31.3 µg/mL, respectively. Sensors were independent from the pH of test solutions within 2–5. Good selectivity was observed towards glycine, ciprofloxacin, creatinine, acid nalidixic, sulfadiazine, cysteine, hydroxylamine and lactose. In flowing media, the biomimetic sensors presented good reproducibility (RSD of ±0.7%), fast response, good sensitivity (65 mV/decade), wide linear range (5.0×10−5 to 1.0×10−2 mol/L), low detection limit (19.8 µg/mL), and a stable baseline for a 5×10−3M citrate buffer (pH 2.5) carrier. The sensors were successfully applied to the analysis of drugs and urine. This work confirms the possibility of using molecularly imprinted polymers as ionophores for organic ion recognition in potentiometric transduction.