922 resultados para Tomografía computada volumétrica Cone-Beam
Resumo:
In continuation of our previous work on the quintet transitions 1s2s2p^2 ^5 P-1s2s2p3d ^5 P^0, ^5 D^0, results on other n = 2 - n' = 3 quintet transitions for elements N, 0 and F are presented. Assignments have been established by comparison with Multi-Configuration Dirac-Fock calculations. High spectral resolution on beam-foil spectroscopy was essential for the identification of most of the lines. For some of the quintet lines decay curves were measured, and the lifetimes extracted were found to be in reasonable agreement with MCDF calculations.
Resumo:
Energy spectra of electrons ejected from collisions between a carbon foil and Ne projectiles with energies between 1.4 and 20 MeV have been measured. Continuous and discrete electron energy distributions are observed. Auger transitions of foil-excited Ne have been studied. Using relativistic Dirac-Fock multiconfiguration calculations, most of the measured Auger transitions have been identified.
Resumo:
To study the behaviour of beam-to-column composite connection more sophisticated finite element models is required, since component model has some severe limitations. In this research a generic finite element model for composite beam-to-column joint with welded connections is developed using current state of the art local modelling. Applying mechanically consistent scaling method, it can provide the constitutive relationship for a plane rectangular macro element with beam-type boundaries. Then, this defined macro element, which preserves local behaviour and allows for the transfer of five independent states between local and global models, can be implemented in high-accuracy frame analysis with the possibility of limit state checks. In order that macro element for scaling method can be used in practical manner, a generic geometry program as a new idea proposed in this study is also developed for this finite element model. With generic programming a set of global geometric variables can be input to generate a specific instance of the connection without much effort. The proposed finite element model generated by this generic programming is validated against testing results from University of Kaiserslautern. Finally, two illustrative examples for applying this macro element approach are presented. In the first example how to obtain the constitutive relationships of macro element is demonstrated. With certain assumptions for typical composite frame the constitutive relationships can be represented by bilinear laws for the macro bending and shear states that are then coupled by a two-dimensional surface law with yield and failure surfaces. In second example a scaling concept that combines sophisticated local models with a frame analysis using a macro element approach is presented as a practical application of this numerical model.
Resumo:
The main focus and concerns of this PhD thesis is the growth of III-V semiconductor nanostructures (Quantum dots (QDs) and quantum dashes) on silicon substrates using molecular beam epitaxy (MBE) technique. The investigation of influence of the major growth parameters on their basic properties (density, geometry, composition, size etc.) and the systematic characterization of their structural and optical properties are the core of the research work. The monolithic integration of III-V optoelectronic devices with silicon electronic circuits could bring enormous prospect for the existing semiconductor technology. Our challenging approach is to combine the superior passive optical properties of silicon with the superior optical emission properties of III-V material by reducing the amount of III-V materials to the very limit of the active region. Different heteroepitaxial integration approaches have been investigated to overcome the materials issues between III-V and Si. However, this include the self-assembled growth of InAs and InGaAs QDs in silicon and GaAx matrices directly on flat silicon substrate, sitecontrolled growth of (GaAs/In0,15Ga0,85As/GaAs) QDs on pre-patterned Si substrate and the direct growth of GaP on Si using migration enhanced epitaxy (MEE) and MBE growth modes. An efficient ex-situ-buffered HF (BHF) and in-situ surface cleaning sequence based on atomic hydrogen (AH) cleaning at 500 °C combined with thermal oxide desorption within a temperature range of 700-900 °C has been established. The removal of oxide desorption was confirmed by semicircular streaky reflection high energy electron diffraction (RHEED) patterns indicating a 2D smooth surface construction prior to the MBE growth. The evolution of size, density and shape of the QDs are ex-situ characterized by atomic-force microscopy (AFM) and transmission electron microscopy (TEM). The InAs QDs density is strongly increased from 108 to 1011 cm-2 at V/III ratios in the range of 15-35 (beam equivalent pressure values). InAs QD formations are not observed at temperatures of 500 °C and above. Growth experiments on (111) substrates show orientation dependent QD formation behaviour. A significant shape and size transition with elongated InAs quantum dots and dashes has been observed on (111) orientation and at higher Indium-growth rate of 0.3 ML/s. The 2D strain mapping derived from high-resolution TEM of InAs QDs embedded in silicon matrix confirmed semi-coherent and fully relaxed QDs embedded in defectfree silicon matrix. The strain relaxation is released by dislocation loops exclusively localized along the InAs/Si interfaces and partial dislocations with stacking faults inside the InAs clusters. The site controlled growth of GaAs/In0,15Ga0,85As/GaAs nanostructures has been demonstrated for the first time with 1 μm spacing and very low nominal deposition thicknesses, directly on pre-patterned Si without the use of SiO2 mask. Thin planar GaP layer was successfully grown through migration enhanced epitaxy (MEE) to initiate a planar GaP wetting layer at the polar/non-polar interface, which work as a virtual GaP substrate, for the GaP-MBE subsequently growth on the GaP-MEE layer with total thickness of 50 nm. The best root mean square (RMS) roughness value was as good as 1.3 nm. However, these results are highly encouraging for the realization of III-V optical devices on silicon for potential applications.
Resumo:
Holes with different sizes from microscale to nanoscale were directly fabricated by focused ion beam (FIB) milling in this paper. Maximum aspect ratio of the fabricated holes can be 5:1 for the hole with large size with pure FIB milling, 10:1 for gas assistant etching, and 1:1 for the hole with size below 100 nm. A phenomenon of volume swell at the boundary of the hole was observed. The reason maybe due to the dose dependence of the effective sputter yield in low intensity Gaussian beam tail regions and redeposition. Different materials were used to investigate variation of the aspect ratio. The results show that for some special material, such as Ni-Be, the corresponding aspect ratio can reach 13.8:1 with Cl₂ assistant etching, but only 0.09:1 for Si(100) with single scan of the FIB.
Resumo:
We present the results of GaInNAs/GaAs quantum dot structures with GaAsN barrier layers grown by solid source molecular beam epitaxy. Extension of the emission wavelength of GaInNAs quantum dots by ~170nm was observed in samples with GaAsN barriers in place of GaAs. However, optimization of the GaAsN barrier layer thickness is necessary to avoid degradation in luminescence intensity and structural property of the GaInNAs dots. Lasers with GaInNAs quantum dots as active layer were fabricated and room-temperature continuous-wave lasing was observed for the first time. Lasing occurs via the ground state at ~1.2μm, with threshold current density of 2.1kA/cm[superscript 2] and maximum output power of 16mW. These results are significantly better than previously reported values for this quantum-dot system.
Resumo:
Tradicionalmente la TC de la base del cráneo ha incluido dos proyecciones, axial y coronal. Sin embargo, cuando un cirujano se dispone a abordar lesiones en esta área se encuentra que en algunas situaciones la disección no se realiza en un plano axial ni coronal, razón por la cual evaluamos la utilidad de los cortes sagitales y multiplanares.
Resumo:
A decentralized model reference controller is designed to reduce the magnitude of the transversal vibration of a flexible cable-stayed beam structure induced by a seismic excitation. The controller design is made based on the principle of sliding mode such that a priori knowledge
Resumo:
Introducción: El glaucoma representa la tercera causa de ceguera a nivel mundial y un diagnóstico oportuno requiere evaluar la excavación del nervio óptico que está relacionada con el área del mismo. Existen reportes de áreas grandes (macrodiscos) que pueden ser protectoras, mientras otros las asocian a susceptibilidad para glaucoma. Objetivo: Establecer si existe asociación entre macrodisco y glaucoma en individuos estudiados con Tomografía Optica Coherente (OCT ) en la Fundación Oftalmológica Nacional. Métodos: Estudio transversal de asociación que incluyó 25 ojos con glaucoma primario de ángulo abierto y 74 ojos sanos. A cada individuo se realizó examen oftalmológico, campo visual computarizado y OCT de nervio óptico. Se compararon por grupos áreas de disco óptico y número de macrodiscos, definidos según Jonas como un área de la media más dos desviaciones estándar y según Adabache como área ≥3.03 mm2 quien evaluó población Mexicana. Resultados: El área promedio de disco óptico fue 2,78 y 2,80 mm2 glaucoma Vs. sanos. De acuerdo al criterio de Jonas, se observó un macrodisco en el grupo sanos y según criterio de Adabache se encontraron ocho y veinticinco macrodiscos glaucoma Vs. sanos. (OR=0,92 IC95%=0.35 – 2.43). Discusión: No hubo diferencia significativa (P=0.870) en el área de disco entre los dos grupos y el porcentaje de macrodiscos para los dos grupos fue similar, aunque el bajo número de éstos no permitió concluir en términos estadísticos sobre la presencia de macrodisco y glaucoma.
Resumo:
Las fracturas proximales del húmero en tres y cuatro partes en mayores de 65 años son un reto diagnóstico y de tratamiento por su complejidad. La clasificación de Neer ha sido una herramienta de ayuda para la caracterización y el tratamiento de las fracturas proximales del húmero y se basa en la evaluación radiográfica la cual puede no dejar claros patrones fractuarios complejos; la tomografía computarizada logra identificar estos patrones complejos los cuales son comunes en pacientes mayores de 65 años, aun así, no es claro el impacto de realizar la tomografía. Este estudio está diseñado para evidenciar si existe un cambio en la clasificación e indicación de manejo en fracturas proximales del húmero en tres y cuatro partes interpretadas con radiografías al ser posteriormente valoradas con tomografía. 15 expertos interpretan e indican manejo de 20 estudios radiográficos de fracturas en tres y cuatro partes del húmero proximal de pacientes mayores de 65 años, previamente asintomáticos, funcionales con única fractura, se realiza la valoración tomográfica y se relaciona a los resultados radiográficos, allí se evidencia si existe o no el cambio de clasificación y manejo de las fracturas. Mediante un estudio observacional, descriptivo y retrospectivo se encuentra que la valoración de la tomografía puede variar la clasificación y el tratamiento indicados inicialmente por los estudios radiográficos en un 60.3% y 54.3% respectivamente, siendo una variación de conducta en más de la mitad de los casos se aprecia la necesidad de realizar el estudio tomográfico.
Resumo:
Las fracturas de la cúpula radial corresponden a un tercio de todas las fracturas del codo en adultos (1), por lo que se toman radiografías o tomografías, sin embargo no existe literatura que soporte la realización de la tomografía como estudio complementario, por lo que preguntamos ¿La tomografía de codo cambia la conducta tomada previamente con radiografía en fracturas de cúpula radial? Se propone un estudio de concordancia, donde se evalúan las radiografías y tomografías por parte de dos cirujanos de codo, de pacientes con diagnóstico de fractura de cúpula radial valorados en urgencias de dos hospitales de tercer nivel de Bogotá desde enero 2011 a enero 2013. Se revisaron 116 historias, 99 cumplieron los criterios, las radiografías fueron revisadas por dos ortopedistas de codo quienes realizaron clasificación de Mason obteniendo un κ 1 (p˂ 0,00), propuesta de tratamiento postradiografía κ 0,934 (p˂ 0,000 IC95% 0.85, 1). Tratamiento post-tomografía de codo κ 0.949 (p˂ 0,00 IC95% 0.867,1). Concordancia intra-ortopedista de la conducta pre y post-tomografía hay cambio en la conducta del ortopedista 1 en 32.6% (κ 0.674 p˂ 0,00 IC95% 0.52, 0.818) y del ortopedista 2 en 36% (κ 0.64 p˂ 0,00 IC95% 0.452, 0.792). Se dividieron los pacientes en Mason I, II, III con concordancia considerable en los pacientes Mason I y III, mientras que en Mason II fue una concordancia aceptable lo que significa que el uso de tomografía de codo cambia la conducta en general pero sobretodo en pacientes clasificados Masson II.
Resumo:
Introducción: La utilidad de la tomografía computarizada como prueba de rutina en la toma de decisiones para las fracturas de radio distal no ha sido bien establecida. Metodología: Estudio de concordancia intra e interobservador en el tratamiento de fracturas de radio distal Fernández V. Se realizaron dos visitas, con intervalo de 2 semanas entre ellas a 15 ortopedistas de trauma quienes evaluaron 22 radiografías de muñeca y sus respectivas tomografías con fracturas de radio distal Fernández V, determinaron para cada caso la mejor opción de tratamiento. Se utilizó el coeficiente Kappa para evaluar la concordancia intra e interobservador para el plan de tratamiento propuesto y se analizaron los resultados según la interpretación de este coeficiente según Landis y Koch. Resultados: La concordancia entre radiografía y tomografía fue moderada kappa 0,47 – 0,51 en las dos evaluaciones respectivamente, manteniéndose el cambio de tratamiento entre 24,9% y 26,7% (p‹0,001). La concordancia observada intraobservador para radiografía y tomografía evaluadas de manera individual fue buena (72,1% y 64,2% respectivamente) evidenciándose cambio en la decisión de tratamiento hasta en el 35,8% de las evaluaciones (p‹0,001); se determinó concordancia observada muy buena en los casos a los que se propuso manejo abierto. No se identificó influencia de la edad en la decisión de tratamiento. Conclusiones: Existe buena concordancia entre radiografía simple y tomografía en fracturas de radio distal Fernández V en cuanto a la decisión de tratamiento, siendo alta la concordancia en los casos en los que se decide manejo abierto.