894 resultados para Measurement in tank
Resumo:
Full Text / Article complet
Resumo:
Background: Acute lower extremity compartment syndrome (CS) is a condition that untreated causes irreversible nerve and muscle ischemia. Treatment by decompression fasciotomy without delay prevents permanent disability. The use of intracompartmental pressure (iCP) measurement in uncertain situations aids in diagnosis of severe leg pain. As an infrequent complication of lower extremity trauma, consequences of CS include chronic pain, nerve injury, and contractures. The purpose of this study was to observe the clinical and functional outcomes for patients with lower extremity CS after fasciotomy. Methods: Retrospective chart analysis for patients with a discharge diagnosis of CS was performed. Physical demographics, employment status, activity at time of injury, injury severity score, fracture types, pain scores, hours to fasciotomy, iCP, serum creatine kinase levels, wound treatment regimen, length of hospital stay, and discharge facility were collected. Lower extremity neurologic examination, pain scores, orthopedic complications, and employment status at 30 days and 12 months after discharge were noted. Results: One hundred twenty‑four patients were enrolled in this study. One hundred and eight patients were assessed at 12 months. Eighty‑one percent were male. Motorized vehicles caused 51% of injuries in males. Forty‑one percent of injuries were tibia fractures. Acute kidney injury occurred in 2.4%. Mean peak serum creatine kinase levels were 58,600 units/ml. Gauze dressing was used in 78.9% of nonfracture patients and negative pressure wound vacuum therapy in 78.2% of fracture patients. About 21.6% of patients with CS had prior surgery. Nearly 12.9% of patients required leg amputation. Around 81.8% of amputees were male. Sixty‑seven percent of amputees had associated vascular injuries. Foot numbness occurred in 20.5% of patients and drop foot palsy in 18.2%. Osteomyelitis developed in 10.2% of patients and fracture nonunion in 6.8%. About 14.7% of patients underwent further orthopedic surgery. At long‑term follow‑up, 10.2% of patients reported moderate lower extremity pain and 69.2% had returned to work. Conclusion: Escalation in leg pain and changes in sensation are the cardinal signs for CS rather than reliance on assessing for firm compartments and pressures. The severity of nerve injury worsens with the delay in performing fasciotomy. Standardized diagnostic protocols and wound treatment strategies will result in improved outcomes from this complication.
Resumo:
Thesis (Master's)--University of Washington, 2016-08
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-08
Resumo:
International audience
Resumo:
En este trabajo se presenta un estudio exploratorio sobre prácticas de aula, relacionadas con las magnitudes longitud, tiempo y masa, llevadas a cabo en Educación Primaria en Portugal. El estudio fijó como objetivos determinar qué objetos y procesos matemáticos están implicados en esas prácticas y qué funciones ejecutan profesor y alumnos durante la realización de las mismas. Los resultados han evidenciado el predominio del conocimiento procedimental y algorítmico y el uso de situaciones extramatemáticas o de la vida cotidiana. El profesor es el gestor sistemático del trabajo de los alumnos así como de los tiempos, espacios y materiales disponibles en el aula.
Resumo:
Ce projet illustre cinq études, mettant l'emphase sur le développement d'une nouvelle approche diagnostique cardiovasculaire afin d'évaluer le niveau d’oxygène contenu dans le myocarde ainsi que sa fonction microvasculaire. En combinant une séquence de résonance magnétique cardiovasculaire (RMC) pouvant détecter le niveau d’oxygène (OS), des manœuvres respiratoires ainsi que des analyses de gaz artériels peuvent être utilisés comme procédure non invasive destinée à induire une réponse vasoactive afin d’évaluer la réserve d'oxygénation, une mesure clé de la fonction vasculaire. Le nombre de tests diagnostiques cardiaques prescrits ainsi que les interventions, sont en pleine expansion. L'imagerie et tests non invasifs sont souvent effectués avant l’utilisation de procédures invasives. L'imagerie cardiaque permet d’évaluer la présence ou absence de sténoses coronaires, un important facteur économique dans notre système de soins de santé. Les techniques d'imagerie non invasives fournissent de l’information précise afin d’identifier la présence et l’emplacement du déficit de perfusion chez les patients présentant des symptômes d'ischémie myocardique. Néanmoins, plusieurs techniques actuelles requièrent la nécessité de radiation, d’agents de contraste ou traceurs, sans oublier des protocoles de stress pharmacologiques ou physiques. L’imagerie RMC peut identifier une sténose coronaire significative sans radiation. De nouvelles tendances d’utilisation de RMC visent à développer des techniques diagnostiques qui ne requièrent aucun facteur de stress pharmacologiques ou d’agents de contraste. L'objectif principal de ce projet était de développer et tester une nouvelle technique diagnostique afin d’évaluer la fonction vasculaire coronarienne en utilisant l' OS-RMC, en combinaison avec des manœuvres respiratoires comme stimulus vasoactif. Ensuite, les objectifs, secondaires étaient d’utilisés l’OS-RMC pour évaluer l'oxygénation du myocarde et la réponse coronaire en présence de gaz artériels altérés. Suite aux manœuvres respiratoires la réponse vasculaire a été validée chez un modèle animal pour ensuite être utilisé chez deux volontaires sains et finalement dans une population de patients atteints de maladies cardiovasculaires. Chez le modèle animal, les manœuvres respiratoires ont pu induire un changement significatif, mesuré intrusivement par débit sanguin coronaire. Il a été démontré qu’en présence d'une sténose coronarienne hémodynamiquement significative, l’OS-RMC pouvait détecter un déficit en oxygène du myocarde. Chez l’homme sain, l'application de cette technique en comparaison avec l'adénosine (l’agent standard) pour induire une vasodilatation coronarienne et les manœuvres respiratoires ont pu induire une réponse plus significative en oxygénation dans un myocarde sain. Finalement, nous avons utilisé les manœuvres respiratoires parmi un groupe de patients atteint de maladies coronariennes. Leurs myocardes étant altérées par une sténose coronaire, en conséquence modifiant ainsi leur réponse en oxygénation. Par la suite nous avons évalué les effets des gaz artériels sanguins sur l'oxygénation du myocarde. Ils démontrent que la réponse coronarienne est atténuée au cours de l’hyperoxie, suite à un stimuli d’apnée. Ce phénomène provoque une réduction globale du débit sanguin coronaire et un déficit d'oxygénation dans le modèle animal ayant une sténose lorsqu’un supplément en oxygène est donné. En conclusion, ce travail a permis d'améliorer notre compréhension des nouvelles techniques diagnostiques en imagerie cardiovasculaire. Par ailleurs, nous avons démontré que la combinaison de manœuvres respiratoires et l’imagerie OS-RMC peut fournir une méthode non-invasive et rentable pour évaluer la fonction vasculaire coronarienne régionale et globale.
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2016.
Resumo:
Full Text / Article complet
Resumo:
With the high oil price variability, the petroleum and the reservoir engineers are usually face to face on how they can evaluate the well performance and productivity. They can improve high productivity from the well construction to the secondary recoveries, but they have never tried a measurement in the drilling operations about the lower productivity index. As a rule, frequently the drilling operations hear from the reservoir engineering and geology that, if there is a formation damage, probably some drilling operations practices were not done properly or the good practice in petroleum engineering or mud engineering were not observed. The study in this working search is an attempt of how to measure a formation damage just from the project drilling to the drilling operations, with datum from the fields in Brazilian northeast and putting into practice a Simulator developed from the modeling on the theory offered by different experts and sources in formation damage
Resumo:
The electrical and optical coupling between subcells in a multijunction solar cell affects its external quantum efficiency (EQE) measurement. In this study, we show how a low breakdown voltage of a component subcell impacts the EQE determination of a multijunction solar cell and demands the use of a finely adjusted external voltage bias. The optimum voltage bias for the EQE measurement of a Ge subcell in two different GaInP/GaInAs/Ge triple-junction solar cells is determined both by sweeping the external voltage bias and by tracing the I–V curve under the same light bias conditions applied during the EQE measurement. It is shown that the I–V curve gives rapid and valuable information about the adequate light and voltage bias needed, and also helps to detect problems associated with non-ideal I–V curves that might affect the EQE measurement. The results also show that, if a non-optimum voltage bias is applied, a measurement artifact can result. Only when the problems associated with a non-ideal I–V curve and/or a low breakdown voltage have been discarded, the measurement artifacts, if any, can be attributed to other effects such as luminescent coupling between subcells.
Resumo:
La clase de educación física es un espacio en el cual los niños y adolescentes pueden incrementar los niveles de actividad física y alcanzar las recomendaciones emitidas por la Organización Mundial de la Salud (OMS), sin embargo, existe poca evidencia científica a nivel nacional sobre las actividades físicas que realizan los estudiantes dentro del ámbito escolar, específicamente dentro de las clases de educación física y sus relaciones con el contexto; es por esto que el objetivo de este estudio fue evaluar los niveles de actividad física de niños y adolescentes durante las clases de educación física en tres colegios oficiales de Bogotá, Colombia, por medio de la herramienta SOFIT. Estudio de diseño descriptivo y transversal realizado entre octubre de 2014 y mayo de 2015. Las observaciones se llevaron a cabo en tres colegios oficiales de la ciudad de Bogotá ubicados en las localidades de Tunjuelito y Ciudad Bolívar que aceptaron su participación en la investigación. Se obtuvo la aprobación para participar de 1361 estudiantes (682 niñas y 679 niños) de 5 a 17 años de los cuales 180 estudiantes (93 niños y 87 niñas) fueron seleccionados de manera aleatoria sistemática, siguiendo el protocolo SOFIT para observar su nivel de actividad física durante las clases de educación física. El 45,23% del tiempo de la clase de educación física los estudiantes mantuvieron un comportamiento sedentario; mientras que el 30.91% y el 23.86% del tiempo de la clase presentaron un nivel de actividad física moderada (AFM) y vigorosa (AFV) respectivamente. El nivel de actividad física moderada a vigorosa (AFMV), fue de 54,78% es decir, 35,27 minutos de la clase. Los docentes no promovieron la actividad física en un 56,47% del tiempo de la clase y se encontró que ningún docente promovió la actividad física fuera de la clase, es decir, alentando a sus estudiantes a que practicaran cualquier forma de actividad física en horas extraescolares. El contexto de la clase que más se desarrolló fue la condición física con un 35,66% del tiempo de la clase, seguido por los contextos de generalidades 24,83% y habilidades 23,84%. El contexto de la clase generalidades está asociada significativamente y de manera negativa (β=-0,32, p=0,006) con menor porcentaje de tiempo en AFM y AFV, las variables activas de SOFIT, lo que sugiere que las clases deben invertir menos tiempo en este contexto e incrementar el porcentaje de tiempo en los otros contextos como condición física y habilidades para aumentar la cantidad de minutos de AFMV en los estudiantes.
Resumo:
•Objetivos: Se tradujo, adaptó y evaluaron las propiedades clinimétricas de la escala POSAS en pacientes con cicatrices hipertróficas (CHT) y queloides (CQ) cómo secuelas de quemadura, que fueron manejados con Z plastias en la Fundación del Quemado en Bogotá (Colombia), entre Junio de 2015 a Abril de 2016. •Métodos: Estudio de evaluación de las propiedades clinimétricas de una escala. Se hizo una traducción y adaptación transcultural siguiendo el método de traducción-retrotraducción. Se aplicó el instrumento adaptado a cincuenta y dos pacientes (n=52) antes y después de la intervención quirúrgica. Se evaluó la validez, confiabilidad, sensibilidad al cambio y la utilidad de la escala. •Resultados: Se hallaron diferencias significativas en los puntajes obtenidos del Observador y del Paciente, antes y después de la intervención quirúrgica (p<0.000); a excepción de prurito. La escala POSAS demostró ser altamente confiable para la Escala del Observador y del Paciente (α = 0.912 y 0.765). Hubo alta correlación en las evaluaciones de dos observadores para las variables ordinales de la Escala del Observador (r>0.6). La concordancia entre las evaluaciones de dos observadores para las variables categóricas de la Escala del Paciente fue buena para la evaluación antes de la intervención para pigmentación y relieve (κ>0.61). Se demostró que el instrumento es capaz de detectar cambios clínicos en el tiempo (p<0.0000), a excepción de prurito (p= 0.271). •Conclusiones: La escala POSAS demostró ser un instrumento válido, confiable y útil para evaluar la calidad de la cicatriz en pacientes con CHT y CQ cómo secuelas de quemadura.
Resumo:
Determinar la validez concurrente del Sistema de Observación de Tiempo de Instrucción de Condición Física (SOFIT) a través de acelerometría, como método para medir los niveles de actividad física (AF) de los escolares de 1º a 9º durante la clase de educación física en tres colegios públicos de Bogotá, Colombia. Estudio transversal entre Octubre de 2014 y Marzo de 2015. La medición se realizó en tres colegios públicos de Bogotá. Participaron 48 estudiantes (25 niñas; 23 niños), entre 5 y 17 años, seleccionados de acuerdo al protocolo de SOFIT. El resultado se categoriza en porcentaje de tiempo en comportamiento sedentario, AF moderada, AF vigorosa, y AF moderada a vigorosa. Se validó utilizando como patrón de oro la acelerometría en las mismas categorías. Se realizó diferencia de medias, regresión lineal y modelo de efectos fijos. La correlación entre SOFIT y acelerometría fue buena para AF moderada (rho=,958; p=0,000), AF vigorosa (rho=,937; p=0,000) y AF de moderada a vigorosa (rho=0,962; p=0,000). Al igual que utilizando un modelo de efectos fijos, AF moderada (β1=0,92; p=0,00), vigorosa (β1=0,94; p=0,00) y AF de moderada a vigorosa (β1=0,95; p=0,00), mostrando ausencia de diferencias significativas entre los dos métodos para la medición de los niveles de AF. El comportamiento sedentario correlacionó positivamente en Spearman (rho=,0965; p=0,000), El sistema SOFIT demostró ser válido para medir niveles de AF en clases de educación física, tras buena correlación y concordancia con acelerometría. SOFIT es un instrumento de fácil acceso y de bajo costo para la medición de la AF durante las clases de educación física en el contexto escolar y se recomienda su uso en futuros estudios.
Resumo:
The present study aimed determines lead (Pb), antimony (Sb) and barium (Ba) as the major elements present in GSR in the environmental air of the Ballistics Laboratory of the Sao Paulo Criminalistics Institute (I.C.-S.P.), Sao Paulo, SP, Brazil. Micro environmental monitors (mini samplers) were located at selected places. The PM2.5 fraction of this airborne was collected in, previously weighted filters, and analyzed by sector field inductively coupled plasma mass spectrometer (SF-HR-ICP-MS). The higher values of the airborne lead, antimony and barium, were found at the firing range (lead (Pb): 58.9 mu g/m(3); barium (Ba): 6.9 mu g/m(3); antimony (Sb): 7.3 mu g/m(3)). The mean value of the airborne in this room during 6 monitored days was Pb: 23.1 mu g/m(3); Ba: 2.2 mu g/m(3); Sb: 1.5 mu g/m(3). In the water tank room, the air did not show levels above the limits of concern. In general the airborne lead changed from day to day, but the barium and antimony remained constant. Despite of that, the obtained values suggest that the workers may be exposed to airborne lead concentration that can result in an unhealthy environment and could increase the risk of chronic intoxication. (C) 2011 Elsevier Ireland Ltd. All rights reserved.