897 resultados para Measurement in Bacteriology


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The electrical and optical coupling between subcells in a multijunction solar cell affects its external quantum efficiency (EQE) measurement. In this study, we show how a low breakdown voltage of a component subcell impacts the EQE determination of a multijunction solar cell and demands the use of a finely adjusted external voltage bias. The optimum voltage bias for the EQE measurement of a Ge subcell in two different GaInP/GaInAs/Ge triple-junction solar cells is determined both by sweeping the external voltage bias and by tracing the I–V curve under the same light bias conditions applied during the EQE measurement. It is shown that the I–V curve gives rapid and valuable information about the adequate light and voltage bias needed, and also helps to detect problems associated with non-ideal I–V curves that might affect the EQE measurement. The results also show that, if a non-optimum voltage bias is applied, a measurement artifact can result. Only when the problems associated with a non-ideal I–V curve and/or a low breakdown voltage have been discarded, the measurement artifacts, if any, can be attributed to other effects such as luminescent coupling between subcells.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La clase de educación física es un espacio en el cual los niños y adolescentes pueden incrementar los niveles de actividad física y alcanzar las recomendaciones emitidas por la Organización Mundial de la Salud (OMS), sin embargo, existe poca evidencia científica a nivel nacional sobre las actividades físicas que realizan los estudiantes dentro del ámbito escolar, específicamente dentro de las clases de educación física y sus relaciones con el contexto; es por esto que el objetivo de este estudio fue evaluar los niveles de actividad física de niños y adolescentes durante las clases de educación física en tres colegios oficiales de Bogotá, Colombia, por medio de la herramienta SOFIT. Estudio de diseño descriptivo y transversal realizado entre octubre de 2014 y mayo de 2015. Las observaciones se llevaron a cabo en tres colegios oficiales de la ciudad de Bogotá ubicados en las localidades de Tunjuelito y Ciudad Bolívar que aceptaron su participación en la investigación. Se obtuvo la aprobación para participar de 1361 estudiantes (682 niñas y 679 niños) de 5 a 17 años de los cuales 180 estudiantes (93 niños y 87 niñas) fueron seleccionados de manera aleatoria sistemática, siguiendo el protocolo SOFIT para observar su nivel de actividad física durante las clases de educación física. El 45,23% del tiempo de la clase de educación física los estudiantes mantuvieron un comportamiento sedentario; mientras que el 30.91% y el 23.86% del tiempo de la clase presentaron un nivel de actividad física moderada (AFM) y vigorosa (AFV) respectivamente. El nivel de actividad física moderada a vigorosa (AFMV), fue de 54,78% es decir, 35,27 minutos de la clase. Los docentes no promovieron la actividad física en un 56,47% del tiempo de la clase y se encontró que ningún docente promovió la actividad física fuera de la clase, es decir, alentando a sus estudiantes a que practicaran cualquier forma de actividad física en horas extraescolares. El contexto de la clase que más se desarrolló fue la condición física con un 35,66% del tiempo de la clase, seguido por los contextos de generalidades 24,83% y habilidades 23,84%. El contexto de la clase generalidades está asociada significativamente y de manera negativa (β=-0,32, p=0,006) con menor porcentaje de tiempo en AFM y AFV, las variables activas de SOFIT, lo que sugiere que las clases deben invertir menos tiempo en este contexto e incrementar el porcentaje de tiempo en los otros contextos como condición física y habilidades para aumentar la cantidad de minutos de AFMV en los estudiantes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

•Objetivos: Se tradujo, adaptó y evaluaron las propiedades clinimétricas de la escala POSAS en pacientes con cicatrices hipertróficas (CHT) y queloides (CQ) cómo secuelas de quemadura, que fueron manejados con Z plastias en la Fundación del Quemado en Bogotá (Colombia), entre Junio de 2015 a Abril de 2016. •Métodos: Estudio de evaluación de las propiedades clinimétricas de una escala. Se hizo una traducción y adaptación transcultural siguiendo el método de traducción-retrotraducción. Se aplicó el instrumento adaptado a cincuenta y dos pacientes (n=52) antes y después de la intervención quirúrgica. Se evaluó la validez, confiabilidad, sensibilidad al cambio y la utilidad de la escala. •Resultados: Se hallaron diferencias significativas en los puntajes obtenidos del Observador y del Paciente, antes y después de la intervención quirúrgica (p<0.000); a excepción de prurito. La escala POSAS demostró ser altamente confiable para la Escala del Observador y del Paciente (α = 0.912 y 0.765). Hubo alta correlación en las evaluaciones de dos observadores para las variables ordinales de la Escala del Observador (r>0.6). La concordancia entre las evaluaciones de dos observadores para las variables categóricas de la Escala del Paciente fue buena para la evaluación antes de la intervención para pigmentación y relieve (κ>0.61). Se demostró que el instrumento es capaz de detectar cambios clínicos en el tiempo (p<0.0000), a excepción de prurito (p= 0.271). •Conclusiones: La escala POSAS demostró ser un instrumento válido, confiable y útil para evaluar la calidad de la cicatriz en pacientes con CHT y CQ cómo secuelas de quemadura.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Determinar la validez concurrente del Sistema de Observación de Tiempo de Instrucción de Condición Física (SOFIT) a través de acelerometría, como método para medir los niveles de actividad física (AF) de los escolares de 1º a 9º durante la clase de educación física en tres colegios públicos de Bogotá, Colombia. Estudio transversal entre Octubre de 2014 y Marzo de 2015. La medición se realizó en tres colegios públicos de Bogotá. Participaron 48 estudiantes (25 niñas; 23 niños), entre 5 y 17 años, seleccionados de acuerdo al protocolo de SOFIT. El resultado se categoriza en porcentaje de tiempo en comportamiento sedentario, AF moderada, AF vigorosa, y AF moderada a vigorosa. Se validó utilizando como patrón de oro la acelerometría en las mismas categorías. Se realizó diferencia de medias, regresión lineal y modelo de efectos fijos. La correlación entre SOFIT y acelerometría fue buena para AF moderada (rho=,958; p=0,000), AF vigorosa (rho=,937; p=0,000) y AF de moderada a vigorosa (rho=0,962; p=0,000). Al igual que utilizando un modelo de efectos fijos, AF moderada (β1=0,92; p=0,00), vigorosa (β1=0,94; p=0,00) y AF de moderada a vigorosa (β1=0,95; p=0,00), mostrando ausencia de diferencias significativas entre los dos métodos para la medición de los niveles de AF. El comportamiento sedentario correlacionó positivamente en Spearman (rho=,0965; p=0,000), El sistema SOFIT demostró ser válido para medir niveles de AF en clases de educación física, tras buena correlación y concordancia con acelerometría. SOFIT es un instrumento de fácil acceso y de bajo costo para la medición de la AF durante las clases de educación física en el contexto escolar y se recomienda su uso en futuros estudios.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introducción: La rápida detección e identificación bacteriana es fundamental para el manejo de los pacientes críticos que presentan una patología infecciosa, esto requiere de métodos rápidos para el inicio de un correcto tratamiento. En Colombia se usan pruebas microbiología convencional. No hay estudios de espectrofotometría de masas en análisis de muestras de pacientes críticos en Colombia. Objetivo general: Describir la experiencia del análisis microbiológico mediante la tecnología MALDI-TOF MS en muestras tomadas en la Fundación Santa Fe de Bogotá. Materiales y Métodos: Entre junio y julio de 2013, se analizaron 147 aislamientos bacterianos de muestras clínicas, las cuales fueron procesadas previamente por medio del sistema VITEK II. Los aislamientos correspondieron a 88 hemocultivos (60%), 28 urocultivos (19%), y otros cultivos 31 (21%). Resultados: Se obtuvieron 147 aislamientos con identificación adecuada a nivel de género y/o especie así: en el 88.4% (130 muestras) a nivel de género y especie, con una concordancia del 100% comparado con el sistema VITEK II. El porcentaje de identificación fue de 66% en el grupo de bacilos gram negativos no fermentadores, 96% en enterobacterias, 100% en gérmenes fastidiosos, 92% en cocos gram positivos, 100% bacilos gram negativos móviles y 100% en levaduras. No se encontró ninguna concordancia en bacilos gram positivos y gérmenes del genero Aggregatibacter. Conclusiones: El MALDI-TOF es una prueba rápida para la identificación microbiológica de género y especie que concuerda con los resultados obtenidos de manera convencional. Faltan estudios para hacer del MALDI-TOF MS la prueba oro en identificación de gérmenes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report measurements of single- and double-spin asymmetries for W^{±} and Z/γ^{*} boson production in longitudinally polarized p+p collisions at sqrt[s]=510  GeV by the STAR experiment at RHIC. The asymmetries for W^{±} were measured as a function of the decay lepton pseudorapidity, which provides a theoretically clean probe of the proton's polarized quark distributions at the scale of the W mass. The results are compared to theoretical predictions, constrained by polarized deep inelastic scattering measurements, and show a preference for a sizable, positive up antiquark polarization in the range 0.05

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Measurement instruments are an integral part of clinical practice, health evaluation and research. These instruments are only useful and able to present scientifically robust results when they are developed properly and have appropriate psychometric properties. Despite the significant increase of rating scales, the literature suggests that many of them have not been adequately developed and validated. The scope of this study was to conduct a narrative review on the process of developing new measurement instruments and to present some tools which can be used in some stages of the development process. The steps described were: I-The establishment of a conceptual framework, and the definition of the objectives of the instrument and the population involved; II-Development of the items and of the response scales; III-Selection and organization of the items and structuring of the instrument; IV-Content validity, V-Pre-test. This study also included a brief discussion on the evaluation of the psychometric properties due to their importance for the instruments to be accepted and acknowledged in both scientific and clinical environments.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Two experiments evaluated an operant procedure for establishing stimulus control using auditory and electrical stimuli as a baseline for measuring the electrical current threshold of electrodes implanted in the cochlea. Twenty-one prelingually deaf children, users of cochlear implants, learned a Go/No Go auditory discrimination task (i.e., pressing a button in the presence of the stimulus but not in its absence). When the simple discrimination baseline became stable, the electrical current was manipulated in descending and ascending series according to an adapted staircase method. Thresholds were determined for three electrodes, one in each location in the cochlea (basal, medial, and apical). Stimulus control was maintained within a certain range of decreasing electrical current but was eventually disrupted. Increasing the current recovered stimulus control, thus allowing the determination of a range of electrical currents that could be defined as the threshold. The present study demonstrated the feasibility of the operant procedure combined with a psychophysical method for threshold assessment, thus contributing to the routine fitting and maintenance of cochlear implants within the limitations of a hospital setting.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The flavonoids present in sugarcane (Saccharum officinarum) extracts were analyzed by liquid chromatography - mass spectrometry (LC-MS), and a study of the fragmentation patterns of selected flavonoids was conducted using orthogonal acceleration time-of-flight electrospray ionization mass spectrometry (ESI-oa-ToF MS). Seven C- and O-glycosylflavones were identified in the extracts, namely, schaftoside, isoschaftoside, luteolin-8-C-(rhamnosylglucoside), vitexin, orientin, tricin-7-O-neohesperidoside and tricin-7-O-glucoside. Of these, five were identified in the absence of direct comparison with their respective standards. The described method also permitted the differentiation of the 6-C and 8-C isomeric flavones, schaftoside and isoschaftoside. The combination of fragmentation data and exact mass measurement showed to be complimentary to the HPLC-UV-MS techniques previously utilized for isomers discrimination in sugarcane studies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction. We present some protocols aiming at partially characterizing banana fruit quality through measurement of some key biochemical parameters. The principle, key advantages, starting plant material, time required and expected results are presented. Materials and methods. This part describes the required laboratory materials and the steps necessary for achieving four protocols making it possible to measure sugar, organic acids and free ACC contents, and in vitro ACC oxidase activity. Results. Standard results obtained by using the protocols described are presented in the figures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This Letter reports new results from the MINOS experiment based on a two-year exposure to muon neutrinos from the Fermilab NuMI beam. Our data are consistent with quantum-mechanical oscillations of neutrino flavor with mass splitting vertical bar Delta m(2)vertical bar = (2.43 +/- 0.13) x 10(-3) eV(2) (68% C.L.) and mixing angle sin(2)(2 theta) > 0.90 (90% C.L.). Our data disfavor two alternative explanations for the disappearance of neutrinos in flight: namely, neutrino decays into lighter particles and quantum decoherence of neutrinos, at the 3.7 and 5.7 standard-deviation levels, respectively.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The PHENIX experiment at the Relativistic Heavy Ion Collider has measured the invariant differential cross section for production of K(S)(0), omega, eta', and phi mesons in p + p collisions at root s 200 GeV. Measurements of omega and phi production in different decay channels give consistent results. New results for the omega are in agreement with previously published data and extend the measured p(T) coverage. The spectral shapes of all hadron transverse momentum distributions measured by PHENIX are well described by a Tsallis distribution functional form with only two parameters, n and T, determining the high-p(T) and characterizing the low-p(T) regions of the spectra, respectively. The values of these parameters are very similar for all analyzed meson spectra, but with a lower parameter T extracted for protons. The integrated invariant cross sections calculated from the fitted distributions are found to be consistent with existing measurements and with statistical model predictions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report the first measurement of transverse single-spin asymmetries in J/psi production from transversely polarized p + p collisions at root s = 200 GeV with data taken by the PHENIX experiment in 2006 and 2008. The measurement was performed over the rapidity ranges 1.2 < vertical bar y vertical bar < 2.2 and vertical bar y vertical bar < 0.35 for transverse momenta up to 6 GeV/c. J/psi production at the Relativistic Heavy Ion Collider is dominated by processes involving initial-state gluons, and transverse single-spin asymmetries of the J/psi can provide access to gluon dynamics within the nucleon. Such asymmetries may also shed light on the long-standing question in QCD of the J/psi production mechanism. Asymmetries were obtained as a function of J/psi transverse momentum and Feynman-x, with a value of -0.086 +/- 0.026(stat) +/- 0.003(syst) in the forward region. This result suggests possible nonzero trigluon correlation functions in transversely polarized protons and, if well defined in this reaction, a nonzero gluon Sivers distribution function.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Correlations of charged hadrons of 1< p(T) < 10 Gev/c with high pT direct photons and pi(0) mesons in the range 5< p(T) < 15 Gev/c are used to study jet fragmentation in the gamma + jet and dijet channels, respectively. The magnitude of the partonic transverse momentum, k(T), is obtained by comparing to a model incorporating a Gaussian kT smearing. The sensitivity of the associated charged hadron spectra to the underlying fragmentation function is tested and the data are compared to calculations using recent global fit results. The shape of the direct photon-associated hadron spectrum as well as its charge asymmetry are found to be consistent with a sample dominated by quark-gluon Compton scattering. No significant evidence of fragmentation photon correlated production is observed within experimental uncertainties.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PHENIX has measured the e(+)e(-) pair continuum in root s(NN) = 200 GeV Au+Au and p+p collisions over a wide range of mass and transverse momenta. The e(+)e(-) yield is compared to the expectations from hadronic sources, based on PHENIX measurements. In the intermediate-mass region, between the masses of the phi and the J/psi meson, the yield is consistent with expectations from correlated c (c) over bar production, although other mechanisms are not ruled out. In the low-mass region, below the phi, the p+p inclusive mass spectrum is well described by known contributions from light meson decays. In contrast, the Au+Au minimum bias inclusive mass spectrum in this region shows an enhancement by a factor of 4.7 +/- 0.4(stat) +/- 1.5(syst) +/- 0.9(model). At low mass (m(ee) < 0.3 GeV/c(2)) and high p(T) (1 < p(T) < 5 GeV/c) an enhanced e(+)e(-) pair yield is observed that is consistent with production of virtual direct photons. This excess is used to infer the yield of real direct photons. In central Au+Au collisions, the excess of the direct photon yield over the p+p is exponential in p(T), with inverse slope T = 221 +/- 19(stat) +/- 19(syst) MeV. Hydrodynamical models with initial temperatures ranging from T(init) similar or equal to 300-600 MeV at times of 0.6-0.15 fm/c after the collision are in qualitative agreement with the direct photon data in Au+Au. For low p(T) < 1 GeV/c the low-mass region shows a further significant enhancement that increases with centrality and has an inverse slope of T similar or equal to 100 MeV. Theoretical models underpredict the low-mass, low-p(T) enhancement.