640 resultados para IONIC SELECTIVITY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effectiveness of drugs is often limited by their insufficient selectivity. I propose designs of therapeutic agents that address this problem. The key feature of these reagents, termed comtoxins (codominance-mediated toxins), is their ability to utilize codominance, a property characteristic of many signals in proteins, including degradation signals (degrons) and nuclear localization signals. A comtoxin designed to kill cells that express intracellular proteins P1 and P2 but to spare cells that lack P1 and/or P2 is a multidomain fusion containing a cytotoxic domain and two degrons placed within or near two domains P1* and P2* that bind, respectively, to P1 and P2. In a cell containing both P1 and P2, these proteins would bind to the P1* and P2* domains of the comtoxin and sterically mask the nearby (appropriately positioned) degrons, resulting in a long-lived and therefore toxic drug. By contrast, in a cell lacking P1 and/or P2, at least one of the comtoxin's degrons would be active (unobstructed), yielding a short-lived and therefore nontoxic drug. A comtoxin containing both a degron and a nuclear localization signal can be designed to kill exclusively cells that contain P1 but lack P2. Analogous strategies yield comtoxins sensitive to the presence (or absence) of more than two proteins in a cell. Also considered is a class of comtoxins in which a toxic domain is split by a flexible insert containing binding sites for the target proteins. The potentially unlimited, combinatorial selectivity of comtoxins may help solve the problem of side effects that bedevils present-day therapies, for even nonselective delivery of a comtoxin would not affect cells whose protein "signatures" differ from the targeted one.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cleavage specificity of the Pvu II and BamHI restriction endonucleases is found to be dramatically reduced at elevated osmotic pressure. Relaxation in specificity of these otherwise highly accurate and specific enzymes, previously termed "star activity," is uniquely correlated with osmotic pressure between 0 and 100 atmospheres. No other colligative solvent property exhibits a uniform correlation with star activity for all of the compounds tested. Application of hydrostatic pressure counteracts the effects of osmotic pressure and restores the natural selectivity of the enzymes for their canonical recognition sequences. These results indicate that water solvation plays an important role in the site-specific recognition of DNA by many restriction enzymes. Osmotic pressure did not induce an analogous effect on the specificity of the EcoRV endonuclease, implying that selective hydration effects do not participate in DNA recognition in this system. Hydrostatic pressure was found to have little effect on the star activity induced by changes in ionic strength, pH, or divalent cation, suggesting that distinct mechanisms may exist for these observed alterations in specificity. Recent evidence has indicated that BamHI and EcoRI share similar structural motifs, while Pvu II and EcoRV belong to a different structural family. Evidently, the use of hydration water to assist in site-specific recognition is a motif neither limited to nor defined by structural families.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho, anticorpos anti-IgGh foram conjugados às nanopartículas de prata (NPAg) para detectar imunoglobulina G humana (IgGh). Um imunoensaio colorimétrico baseado na diminuição da agregação devido ao aumento da repulsão eletrostática após a interação ligante-alvo. A agregação é induzida pela variação da força iônica e uma mudança da coloração da suspensão coloidal de amarelo para vermelho pode ser observada. Na presença de IgGh, a agregação é inibida e a coloração da suspensão coloidal não se altera. As nanopartículas foram obtidas por meio de cinco procedimentos diferentes e caracterizadas por espectroscopia UV-Vis, espalhamento dinâmico de luz, difração de raios-X e microscopia eletrônica. Glicose e borohidreto de sódio foram utilizados como agentes redutores, enquanto CTAB e β-ciclodextrina foram utilizados como estabilizantes. Citrato de sódio foi utilizado como agente redutor e/ou estabilizante. Nanoesferas de carbono foram obtidas por tratamento hidrotérmico de uma solução aquosa de glicose e também foram utilizadas no preparo das nanopartículas. As nanopartículas foram funcionalizadas com ácido mercaptossuccínico e a conjugação ocorreu devido à interação entre grupos aminas e grupos carboxílicos ionizados, presentes no anticorpo e agente de acoplamento, respectivamente. A estabilidade dos conjugados e o efeito da adição de IgGh foram avaliados para todos os sistemas preparados. As nanopartículas de prata preparadas com borohidreto de sódio e citrato de sódio foram selecionadas para serem aplicadas no desenvolvimento do imunoensaio e as condições experimentais foram avaliadas. Em condições ótimas, observou-se uma correlação linear entre a diminuição da agregação do sistema (NPAg-anti-IgGh) e a concentração de IgGh (0 a 200 ng mL-1). O limite de detecção foi estimado em 25 ng mL-1. O método colorimétrico apresentou boa seletividade para a detecção de IgGh. Além disso, foi obtido um resultado satisfatório ao aplicar o método para determinação do fator IX de coagulação. Foi desenvolvido também um método para determinação de ATP baseado na agregação de nanopartículas de ouro. Aptâmeros foram utilizados como elemento de reconhecimento. Em princípio, o método pode ser aplicável à determinação de outros analitos, por meio da substituição do aptâmero utilizado neste trabalho pelo oligonucleotídeo específico para o alvo de interesse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Author: Kristopher D. Veo Title: Amino acid residues implicated in the interaction of Melanocortin ligands and their receptors: A study of MC2R selectivity Advisor: Dr. Robert M. Dores Degree Date: August 2009 ABSTRACT Melanocortin receptor ligand selectivity has been a question not easily answered. The inability to functionally express melanocortin 2 receptor (MC2R) has inhibited the study of why MC2R is only stimulated by ACTH, a melanocortin hormone. With the recent discovery of the MC2R accessory protein (MRAP), creating a heterologous system is now feasible. Using a general cell line like CHO-K1 cells, which do not express endogenous MCRs, we were able to create a heterologous expression system and test the selectivity of MC2R using analog variants of ACTH(1-24). Our results indicate an amino acid requirement in the C-terminal portion of ACTH(1-24) for activation, which supports the 2-step method of activation hypothesized for MC2R. This site, the tetra basic cleavage site, when altered does not stimulate cAMP production and does not compete with ACTH(1-24) for binding. We also demonstrate the potential for a non-mammalian MC2R system in cloning full length Silurana tropicalis MC2R and completed localization studies with this system with MRAP using CHO-K1 cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method is reported, whereby screen-printed electrodes (SPELs) are combined with dispersive liquid–liquid microextraction. In-situ ionic liquid (IL) formation was used as an extractant phase in the microextraction technique and proved to be a simple, fast and inexpensive analytical method. This approach uses miniaturized systems both in sample preparation and in the detection stage, helping to develop environmentally friendly analytical methods and portable devices to enable rapid and onsite measurement. The microextraction method is based on a simple metathesis reaction, in which a water-immiscible IL (1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [Hmim][NTf2]) is formed from a water-miscible IL (1-hexyl-3-methylimidazolium chloride, [Hmim][Cl]) and an ion-exchange reagent (lithium bis[(trifluoromethyl)sulfonyl]imide, LiNTf2) in sample solutions. The explosive 2,4,6-trinitrotoluene (TNT) was used as a model analyte to develop the method. The electrochemical behavior of TNT in [Hmim][NTf2] has been studied in SPELs. The extraction method was first optimized by use of a two-step multivariate optimization strategy, using Plackett–Burman and central composite designs. The method was then evaluated under optimum conditions and a good level of linearity was obtained, with a correlation coefficient of 0.9990. Limits of detection and quantification were 7 μg L−1 and 9 μg L−1, respectively. The repeatability of the proposed method was evaluated at two different spiking levels (20 and 50 μg L−1), and coefficients of variation of 7 % and 5 % (n = 5) were obtained. Tap water and industrial wastewater were selected as real-world water samples to assess the applicability of the method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quaternary ammonium-functionalized silica materials were synthesized and applied for solid-phase extraction (SPE) of aromatic amines, which are classified as priority pollutants by US Environmental Protection Agency. Hexamethylenetetramine used for silica surface modification for the first time was employed as SPE sorbent under normal phase conditions. Hexaminium-functionalized silica demonstrated excellent extraction efficiencies for o-toluidine, 4-ethylaniline and quinoline (recoveries 101–107%), while for N,N-dimethylaniline and N-isopropylaniline recoveries were from low to moderate (14–46%). In addition, the suitability of 1-alkyl-3-(propyl-3-sulfonate) imidazolium-functionalized silica as SPE sorbent was tested under normal phase conditions. The recoveries achieved for the five aromatic amines ranged from 89 to 99%. The stability of the sorbent was evaluated during and after 150 extractions. Coefficients of variation between 4.5 and 10.2% proved a high stability of the synthesized sorbent. Elution was carried out using acetonitrile in the case of hexaminium-functionalized silica and water for 1-alkyl-3-(propyl-3-sulfonate) imidazolium-functionalized silica sorbent. After the extraction the analytes were separated and detected by liquid chromatography ultraviolet detection (LC-UV). The retention mechanism of the materials was primarily based on polar hydrogen bonding and π–π interactions. Comparison made with activated silica proved the quaternary ammonium-functionalized materials to offer different selectivity and better extraction efficiencies for aromatic amines. Finally, 1-alkyl-3-(propyl-3-sulfonate) imidazolium-functionalized silica sorbent was successfully tested for the extraction of wastewater and soil samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of carbide-derived carbons (CDC) have been prepared starting from TiC and using different chlorine treatment temperatures (500–1200 °C). Contrary to N2 adsorption measurements at −196 °C, CO2 adsorption measurements at room temperature and high pressure (up to 1 MPa) together with immersion calorimetry measurements into dichloromethane suggest that the synthesized CDC exhibit a similar porous structure, in terms of narrow pore volume, independently of the temperature of the reactive extraction treatment used (samples synthesized below 1000 °C). Apparently, these carbide-derived carbons exhibit narrow constrictions were CO2 adsorption under standard conditions (0 °C and atmospheric pressure) is kinetically restricted. The same accounts for a slightly larger molecule as N2 at a lower adsorption temperature (−196 °C), i.e. textural parameters obtained from N2 adsorption measurements on CDC must be underestimated. Furthermore, here we show experimentally that nitrogen exhibits an unusual behavior, poor affinity, on these carbide-derived carbons. CH4 with a slightly larger diameter (0.39 nm) is able to partially access the inner porous structure whereas N2, with a slightly smaller diameter (0.36 nm), does not. Consequently, these CDC can be envisaged as excellent sorbent for selective CO2 capture in flue-gas streams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immobilization of enzymes may produce alterations in their observed activity, specificity or selectivity. Although in many cases an impoverishment of the enzyme properties is observed upon immobilization (caused by the distortion of the enzyme due to the interaction with the support) in some instances such properties may be enhanced by this immobilization. These alterations in enzyme properties are sometimes associated with changes in the enzyme structure. Occasionally, these variations will be positive. For example, they may be related to the stabilization of a hyperactivated form of the enzyme, like in the case of lipases immobilized on hydrophobic supports via interfacial activation. In some other instances, these improvements will be just a consequence of random modifications in the enzyme properties that in some reactions will be positive while in others may be negative. For this reason, the preparation of a library of biocatalysts as broad as possible may be a key turning point to find an immobilized biocatalyst with improved properties when compared to the free enzyme. Immobilized enzymes will be dispersed on the support surface and aggregation will no longer be possible, while the free enzyme may suffer aggregation, which greatly decreases enzyme activity. Moreover, enzyme rigidification may lead to preservation of the enzyme properties under drastic conditions in which the enzyme tends to become distorted thus decreasing its activity. Furthermore, immobilization of enzymes on a support, mainly on a porous support, may in many cases also have a positive impact on the observed enzyme behavior, not really related to structural changes. For example, the promotion of diffusional problems (e.g., pH gradients, substrate or product gradients), partition (towards or away from the enzyme environment, for substrate or products), or the blocking of some areas (e.g., reducing inhibitions) may greatly improve enzyme performance. Thus, in this tutorial review, we will try to list and explain some of the main reasons that may produce an improvement in enzyme activity, specificity or selectivity, either real or apparent, due to immobilization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach is presented, whereby gold nanostructured screen-printed carbon electrodes (SPCnAuEs) are combined with in-situ ionic liquid formation dispersive liquid–liquid microextraction (in-situ IL-DLLME) and microvolume back-extraction for the determination of mercury in water samples. In-situ IL-DLLME is based on a simple metathesis reaction between a water-miscible IL and a salt to form a water-immiscible IL into sample solution. Mercury complex with ammonium pyrrolidinedithiocarbamate is extracted from sample solution into the water-immiscible IL formed in-situ. Then, an ultrasound-assisted procedure is employed to back-extract the mercury into 10 µL of a 4 M HCl aqueous solution, which is finally analyzed using SPCnAuEs. Sample preparation methodology was optimized using a multivariate optimization strategy. Under optimized conditions, a linear range between 0.5 and 10 µg L−1 was obtained with a correlation coefficient of 0.997 for six calibration points. The limit of detection obtained was 0.2 µg L−1, which is lower than the threshold value established by the Environmental Protection Agency and European Union (i.e., 2 µg L−1 and 1 µg L−1, respectively). The repeatability of the proposed method was evaluated at two different spiking levels (3 and 10 µg L−1) and a coefficient of variation of 13% was obtained in both cases. The performance of the proposed methodology was evaluated in real-world water samples including tap water, bottled water, river water and industrial wastewater. Relative recoveries between 95% and 108% were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Very different carbon materials have been used as support in the preparation of supported ionic liquid phase samples (SILP). Some of them have been oxidized, either strongly (with ammonium persulfate solution) or weakly (with air at 300 °C, 2 h). The purpose is to establish which properties of the supports (e.g., porosity -volume and type-, surface area, oxygen surface chemistry and morphology) determine the IL adsorption capacity and the stability (immobilization) of the supported IL phase. The ionic liquid used in this work is 1-butyl-3-methyl-imidazolium hexafluorophosphate ([bmim][PF6]). For each support, samples with different amounts of ionic liquid have been prepared. The maximum IL that can be loaded depends mainly on the total pore volume of the supports. For comparable pore volumes, the porosity type and the oxygen surface content have no influence on the IL loading. The supported IL fills most of the pores, leaving some blocked porosity. The stability of the supported IL phase (especially important for its subsequent use in catalysis) has been tested in water under general hydrogenation conditions (60 °C and 10 bar H2). In general, leaching is low but it increases with the amount of IL loaded and with the oxidation treatments of the supports.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interface between Au(hkl) basal planes and the ionic liquid 1-Ethyl-2,3-dimethyl imidazolium bis(trifluoromethyl)sulfonil imide was investigated by using both cyclic voltammetry and laser-induced temperature jump. Cyclic voltammetry showed characteristic features, revealing surface sensitive processes at the interfaces Au(hkl)/[Emmim][Tf2N]. From laser-induced heating the potential of maximum entropy (pme) is determined. Pme is close to the potential of zero charge (pzc) and, therefore, the technique provides relevant interfacial information. The following order for the pme values has been found: Au(111) > Au(100) > Au(110). This order correlates well with work function data and values of pzc in aqueous solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach is presented to determine mercury in urine samples, employing vortex-assisted ionic liquid dispersive liquid–liquid microextraction and microvolume back-extraction to prepare samples, and screen-printed electrodes modified with gold nanoparticles for voltammetric analysis. Mercury was extracted directly from non-digested urine samples in a water-immiscible ionic liquid, being back-extracted into an acidic aqueous solution. Subsequently, it was determined using gold nanoparticle-modified screen-printed electrodes. Under optimized microextraction conditions, standard addition calibration was applied to urine samples containing 5, 10 and 15 μg L−1 of mercury. Standard addition calibration curves using standards between 0 and 20 μg L−1 gave a high level of linearity with correlation coefficients ranging from 0.990 to 0.999 (N = 5). The limit of detection was empirical and statistically evaluated, obtaining values that ranged from 0.5 to 1.5 μg L−1, and from 1.1 to 1.3 μg L−1, respectively, which are significantly lower than the threshold level established by the World Health Organization for normal mercury content in urine (i.e., 10–20 μg L−1). A certified reference material (REC-8848/Level II) was analyzed to assess method accuracy finding 87% and 3 μg L−1 as the recovery (trueness) and standard deviation values, respectively. Finally, the method was used to analyze spiked urine samples, obtaining good agreement between spiked and found concentrations (recovery ranged from 97 to 100%).