Screen-printed electrode-based electrochemical detector coupled with in-situ ionic-liquid-assisted dispersive liquid–liquid microextraction for determination of 2,4,6-trinitrotoluene


Autoria(s): Fernández Martínez, Elena; Vidal, Lorena; Iniesta Valcárcel, Jesús; Metters, Jonathan P.; Banks, Craig E.; Canals Hernández, Antonio
Contribuinte(s)

Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología

Universidad de Alicante. Departamento de Química Física

Universidad de Alicante. Instituto Universitario de Materiales

Universidad de Alicante. Instituto Universitario de Electroquímica

Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas

Electroquímica Aplicada y Electrocatálisis

Data(s)

22/05/2014

22/05/2014

01/03/2014

Resumo

A novel method is reported, whereby screen-printed electrodes (SPELs) are combined with dispersive liquid–liquid microextraction. In-situ ionic liquid (IL) formation was used as an extractant phase in the microextraction technique and proved to be a simple, fast and inexpensive analytical method. This approach uses miniaturized systems both in sample preparation and in the detection stage, helping to develop environmentally friendly analytical methods and portable devices to enable rapid and onsite measurement. The microextraction method is based on a simple metathesis reaction, in which a water-immiscible IL (1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [Hmim][NTf2]) is formed from a water-miscible IL (1-hexyl-3-methylimidazolium chloride, [Hmim][Cl]) and an ion-exchange reagent (lithium bis[(trifluoromethyl)sulfonyl]imide, LiNTf2) in sample solutions. The explosive 2,4,6-trinitrotoluene (TNT) was used as a model analyte to develop the method. The electrochemical behavior of TNT in [Hmim][NTf2] has been studied in SPELs. The extraction method was first optimized by use of a two-step multivariate optimization strategy, using Plackett–Burman and central composite designs. The method was then evaluated under optimum conditions and a good level of linearity was obtained, with a correlation coefficient of 0.9990. Limits of detection and quantification were 7 μg L−1 and 9 μg L−1, respectively. The repeatability of the proposed method was evaluated at two different spiking levels (20 and 50 μg L−1), and coefficients of variation of 7 % and 5 % (n = 5) were obtained. Tap water and industrial wastewater were selected as real-world water samples to assess the applicability of the method.

The authors would like to thank the Spanish Ministry of Science and Innovation (project n. CTQ2011-23968), Generalitat Valenciana (Spain) (projects n. ACOMP/2013/072 and PROMETEO/2012/038) and Universidad de Alicante (Spain) (project n. GRE12-45) for the financial support. E.F. also thanks Generalitat Valenciana for her fellowship.

Identificador

Analytical and Bioanalytical Chemistry. 2014, 406(8): 2197-2204. doi:10.1007/s00216-013-7415-y

1618-2642 (Print)

1618-2650 (Online)

http://hdl.handle.net/10045/37264

10.1007/s00216-013-7415-y

Idioma(s)

eng

Publicador

Springer Berlin Heidelberg

Relação

http://dx.doi.org/10.1007/s00216-013-7415-y

Direitos

The original publication is available at www.springerlink.com

info:eu-repo/semantics/openAccess

Palavras-Chave #Liquid-phase microextraction #Dispersive liquid-liquid microextraction #Ionic liquid #Screen-printed electrodes #2,4,6-Trinitrotoluene #Water samples #Química Analítica #Química Física
Tipo

info:eu-repo/semantics/article