520 resultados para Ejection.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Doxorubicin (Dox), a mainstay of adjuvant breast cancer treatment, is associated with cardiac toxicity in the form of left ventricular dysfunction (LVD), LV diastolic dysfunction, or LV systolic dysfunction. Study objectives were to evaluate the prevalence of LVD in long-term breast cancer survivors treated with Dox and determine if brain-type natriuretic peptide (BNP) may help identify patients at risk for LVD. Patients who participated in prospective clinical trials of adjuvant Dox-based chemotherapy for breast cancer with a baseline left ventricular (LV) ejection fraction evaluation from 1999 to 2006 were retrospectively identified from the St Vincent's University Hospital database. Patients were invited to undergo transthoracic echocardiography, BNP analysis, and cardiovascular (CV) risk factor assessment. LVDD was defined as left atrial volume index >34 mL/m(2) and/or lateral wall E prime <10 m/s, and LVSD as LVEF <50 %. Of 212 patients identified, 154 participated, 19 patients had died (no cardiac deaths), and 39 declined. Mean age was 60.7 [55:67] years. A majority of the patients (128, 83 %) had low CV risk (0/1 risk factors), 21 (13.6 %) had 2 RFs, and 5 (3.2 %) ≥3 RFs. BMI was 27.2 ± 4.9 kg/m(2). Median Dox dose was 240 mg/m(2) [225-298]; 92 patients (59.7 %) received ≤240 mg/m(2) and 62 (40.3 %) > 240 mg/m(2). Baseline LVEF was 68.2 ± 8 %. At follow-up of 10.8 ± 2.2 years, LVEF was 64.4 ± 6 %. Three (1.9 %) subjects had LVEF <50 % and one (0.7 %) had LVDD. Dox >240 mg/m2 was associated with any LVEF drop. BNP levels at follow-up were 20.3 pg/ml [9.9-36.5] and 21.1 pg/ml [9.8-37.7] in those without LVD and 61.5 pg/ml [50-68.4] in those with LVD (p = 0.04). Long-term prospective data describing the impact of Dox on cardiotoxicity are sparse. At over 10 years of follow-up, decreases in LVEF are common, and dose related, but LVD as defined is infrequent (2.6 %). Monitoring with BNP for subclinical LVD needs further evaluation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Persistently elevated natriuretic peptide (NP) levels in heart failure (HF) patients are associated with impaired prognosis. Recent work suggests that NP-guided therapy can improve outcome, but the mechanisms behind an elevated BNP remain unclear. Among the potential stimuli for NP in clinically stable patients are persistent occult fluid overload, wall stress, inflammation, fibrosis, and ischemia. The purpose of this study was to identify associates of B-type natriuretic peptide (BNP) in a stable HF population.

METHODS: In a prospective observational study of 179 stable HF patients, the association between BNP and markers of collagen metabolism, inflammation, and Doppler-echocardiographic parameters including left ventricular ejection fraction (LVEF), left atrial volume index (LAVI), and E/e prime (E/e') was measured.

RESULTS: Univariable associates of elevated BNP were age, LVEF, LAVI, E/e', creatinine, and markers of collagen turnover. In a multiple linear regression model, age, creatinine, and LVEF remained significant associates of BNP. E/e' and markers of collagen turnover had a persistent impact on BNP independent of these covariates.

CONCLUSION: Multiple variables are associated with persistently elevated BNP levels in stable HF patients. Clarification of the relative importance of NP stimuli may help refine NP-guided therapy, potentially improving outcome for this at-risk population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The role of statin therapy in heart failure (HF) is unclear. The amino-terminal propeptide of procollagen type III (PIIINP) predicts outcome in HF, and yet there are conflicting reports of statin therapy effects on PIIINP.

OBJECTIVES: This study determined whether there was an increase in serum markers of inflammation, fibrosis (including PIIINP), and B-type natriuretic peptide (BNP) in patients with systolic HF and normal total cholesterol and determined the effects of long-term treatment with atorvastatin on these markers.

METHODS: Fifty-six white patients with systolic HF and normal cholesterol levels (age 72 [13] years; 68% male; body mass index 27.0 [7.3] kg/m(2); ejection fraction 35 [13]%; 46% with history of smoking) were randomly allocated to atorvastatin treatment for 6 months, titrated to 40 mg/d (A group) or not (C group). Age- and/or sex-matched subjects without HF (N group) were also recruited. Biomarkers were measured at baseline (all groups) and 6 months (A and C groups).

RESULTS: Serum markers of collagen turnover, inflammation, and BNP were significantly elevated in HF patients compared with normal participants (all P < 0.05). There were correlations between these markers in HF patients but not in normal subjects. Atorvastatin treatment for 6 months caused a significant reduction in the following biomarkers compared with baseline: BNP, from median (interquartile range) 268 (190-441) pg/mL to 185 (144-344) pg/mL; high-sensitivity C-reactive protein (hs-CRP), from 5.26 (1.95 -9.29) mg/L to 3.70 (2.34-6.81) mg/L; and PIIINP, from 4.65 (1.86) to 4.09 (1.25) pg/mL (all P < 0.05 baseline vs 6 months). Between-group differences were significant for PIIINP only (P = 0.027). There was a positive interaction between atorvastatin effects and baseline hs-CRP and PIIINP (P < 0.01).

CONCLUSIONS: Long-term statin therapy reduced PIIINP in this small, selected HF population with elevated baseline levels. Further evaluation of statin therapy in the management of HF patients with elevated PIIINP is warranted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Hypertension is one of the main drivers of the heart failure (HF) epidemic. The aims of this study were to profile fibro-inflammatory biomarkers across stages of the hypertensive heart disease (HHD) spectrum and to examine whether particular biochemical profiles in asymptomatic patients identify a higher risk of evolution to HF.

METHODS AND RESULTS: This was a cross-sectional observational study involving a population of 275 stable hypertensive patients divided into two different cohorts: Group 1, asymptomatic hypertension (AH) (n= 94); Group 2, HF with preserved ejection fraction (n= 181). Asymptomatic hypertension patients were further subdivided according to left atrial volume index ≥34 mL/m(2) (n= 30) and <34 mL/m(2) (n= 64). Study assays involved inflammatory markers [interleukin 6 (IL6), interleukin 8 (IL8), monocyte chemoattractant protein 1 (MCP1), and tumour necrosis factor α], collagen 1 and 3 metabolic markers [carboxy-terminal propeptide of collagen 1, amino-terminal propeptide of collagen 1, amino-terminal propeptide of collagen 3 (PIIINP), and carboxy-terminal telopeptide of collagen 1 (CITP)], extra-cellular matrix turnover markers [matrix metalloproteinase 2 (MMP2), matrix metalloproteinase 9 (MMP9), and tissue inhibitor of metalloproteinase 1 (TIMP1)], and the brain natriuretic peptide. Data were adjusted for age, sex, systolic blood pressure, and creatinine. Heart failure with preserved ejection fraction was associated with an increased inflammatory signal (IL6, IL8, and MCP1), an increased fibrotic signal (PIIINP and CITP), and an increased matrix turnover signal (MMP2 and MMP9). Alterations in MMP and TIMP enzymes were found to be significant indicators of greater degrees of asymptomatic left ventricular diastolic dysfunction.

CONCLUSION: These data define varying fibro-inflammatory profiles throughout different stages of HHD. In particular, the observations on MMP9 and TIMP1 raise the possibility of earlier detection of those at risk of evolution to HF which may help focus effective preventative strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Device-based remote monitoring (RM) has been linked to improved clinical outcomes at short to medium-term follow-up. Whether this benefit extends to long-term follow-up is unknown. We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICD). METHODS: We performed a retrospective cohort study of consecutive patients who underwent ICD implantation for primary prevention. RM was initiated with patient consent according to availability of RM hardware at implantation. Patients with concomitant cardiac resynchronization therapy were excluded. Data on hospitalizations, mortality and cause of death were systematically assessed using a nationwide healthcare platform. A Cox proportional hazards model was employed to estimate the effect of RM on mortality and a composite endpoint of cardiovascular mortality and hospital admission due to heart failure (HF). RESULTS: 312 patients were included with a median follow-up of 37.7months (range 1 to 146). 121 patients (38.2%) were under RM since the first outpatient visit post-ICD and 191 were in conventional follow-up. No differences were found regarding age, left ventricular ejection fraction, heart failure etiology or NYHA class at implantation. Patients under RM had higher long-term survival (hazard ratio [HR] 0.50, CI 0.27-0.93, p=0.029) and lower incidence of the composite outcome (HR 0.47, CI 0.27-0.82, p=0.008). After multivariate survival analysis, overall survival was independently associated with younger age, higher LVEF, NYHA class lower than 3 and RM. CONCLUSION: RM was independently associated with increased long-term survival and a lower incidence of a composite endpoint of hospitalization for HF or cardiovascular mortality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La présente thèse propose une étude expérimentale du décollement dans le diffuseur d’un modèle de turbine hydroélectrique bulbe. Le décollement se produit quand la turbine est opérée à forte charge et il réduit la section effective de récupération du diffuseur. La diminution de la performance du diffuseur à forte charge engendre une baisse brusque de l’efficacité de la turbine et de la puissance extraite. Le modèle réduit de bulbe est fidèle aux machines modernes avec un diffuseur particulièrement divergent. Les performances de la turbine sont mesurées sur une large gamme de points d’opération pour déterminer les conditions les plus intéressantes pour l’étude du décollement et pour étudier la distribution paramétrique de ce phénomène. La pression est mesurée le long de l’aspirateur par des capteurs dynamiques affleurants alors que les champs de vitesse dans la zone de décollement sont mesurés avec une méthode PIV à deux composantes. Les observations à la paroi sont pour leur part faites à l’aide de brins de laine. Pour un débit suffisant, le gradient de pression adverse induit par la géométrie du diffuseur affaiblit suffisamment la couche limite, entraînant ainsi l’éjection de fluide de la paroi le long d’une large enveloppe tridimensionelle. Le décollement instationnaire tridimensionnel se situe dans la même zone du diffuseur indépendamment du point d’opération. L’augmentation du débit provoque à la fois une extension de la zone de décollement et une augmentation de l’occurrence de ses manifestations. La position et la forme du front de décollement fluctue significativement sans périodicité. L’analyse topologique et celle des tourbillons des champs de vitesse instantanés montrent une topologie du front de décollement complexe qui diffère beaucoup d’une réalisation à l’autre. Bien que l’écoulement soit turbulent, les tourbillons associés aux foyers du front sont clairement plus gros et plus intenses que ceux de la turbulence. Cela suggère que le mécanisme d’enroulement menant aux tourbillons du décollement est clairement distinct des mécanismes de la turbulence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Área de especialização: Intervenção Cardiovascular.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Heart failure (HF) is a major health concern affecting 15 million people in Europe and around 900 000 people in the U.K. HF predominantly affects the elderly, with the mean age of patients with a diagnosis of HF between 70 and 80 years. Most previous HF studies have accordingly focused on older patients. Although HF is less common in younger adults (<65 years), 15% to 20% of patients hospitalised with HF are younger than 60 years of age. Very few studies have described the characteristics of younger adults with HF and its outcome. The aims of this thesis are to describe the clinical characteristics of younger adults with HF, explore the epidemiology of HF in younger adults and determine their short- and long-term outcomes. This was made possible by access multiple databases consisting of large patient cohorts with HF. The first chapter is a systematic literature review of younger adults with HF. Gaps in the current literature were identified and the thesis focused on some of these. The CHARM study allows detail characterisations of younger adults with HF. It recorded characteristics of patients with HF, including symptoms and signs of HF, electrocardiographic changes, chest radiographic findings, and also left ventricular ejection fraction. HF hospitalisations and its precipitating factors were also recorded systematically. Younger adults were more likely to have a third heart sound and hepatomegaly, but less likely to have pulmonary crackles and peripheral oedema. Similarly, radiological findings in younger adults were less likely to show interstitial pulmonary oedema or pleural effusion. Interestingly, younger adults aged <40 years not only have similar HF hospitalisation rate to older patients, however during their presentation with decompensated HF, they were less likely to have clinical pulmonary oedema and radiological signs of HF. Physicians managing younger adults with HF need to be aware of this. Younger adults were also less compliant with medications and lifestyle restriction resulting in hospitalisation with decompensated HF. Fortunately, despite these challenges, mortality rates in younger adults with HF were lower compared to older patients. To further substantiate the findings from the CHARM study, the MAGGIC study, a meta-analysis consists of over 40 000 patients with HF from large observational studies and randomised controlled trials, was examined. In both databases, the commonest aetiology of HF in younger adults was dilated cardiomyopathy. The ejection fraction was the lowest in younger adults. Similar to the CHARM study, mortality rates in younger adults were lower compared to older patients. However, in the MAGGIC study, by stratifying mortality into patients with preserved ejection fraction and with reduced ejection fraction, younger patients with preserved ejection fraction have a much lower mortality rate compared to patients with reduced ejection fraction. Findings from clinical trials are not always reflective of the real life clinical practice. The U.K. Clinical Practice Research Datalink (CPRD), a large and well-validated primary care database with 654 practices contributing information into the database representing approximated 8% of the U.K. population, is a rich dataset offering a unique opportunity to examine the characteristics, treatments, and outcomes of younger adults with HF in the community. In contrast to the CHARM and MAGGIC studies, younger adults aged <40 years were stratified into 20-29 and 30-39 years in the CPRD analysis. This is possible due to the larger number of younger adults with HF. Further stratifying the younger age groups demonstrated heterogeneity among younger adults with HF. In contrast to previous data showing younger adults have lower co-morbidities, the proportions of depression, chronic kidney disease, asthma, and any connective tissue disease were high among patients aged 20-29 years in the analysis from the CPRD. Surprisingly, the treatment rates for angiotensin converting enzyme (ACE) inhibitor, and aldosterone antagonist were the lowest in patients aged 20-29 years. With the exception of patients aged ≥80 years, treatment rate with beta-blocker was also the lowest in patients aged 20-29 years. With over two decades of follow up, long-term mortality rates in younger adults with HF can be determined. The mortality rates continued to decline from 1988 to 2011. Physicians managing younger adults with HF can now use this contemporary data to provide prognostic information to patients and their family. A hospital administrative database is the logical next platform to explore younger adults with HF. The Alberta Ministry of Health database links an outpatient database to a hospitalisation database providing ample data to examine the relationship between outpatient clinic visits and hospital admissions in younger adults with HF. Following a diagnosis of HF in the outpatient setting, younger adults were admitted to the hospital with decompensated HF much sooner than older patients. Younger adults also presented to emergency department more frequently following their first hospitalisation for HF. In conclusion, this thesis presented the characteristics and outcomes of younger adults with HF, and helped to extend our current understanding on this important topic. I hope the data presented here will benefit not only physicians looking after younger adults with HF, but also patients and their family.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulmonary hypertension (PH) is a rare but serious condition that causes progressive right ventricular (RV) failure and death. PH may be idiopathic, associated with underlying connective-tissue disease or hypoxic lung disease, and is also increasingly being observed in the setting of heart failure with preserved ejection fraction (HFpEF). The management of PH has been revolutionised by the recent development of new disease-targeted therapies which are beneficial in pulmonary arterial hypertension (PAH), but can be potentially harmful in PH due to left heart disease, so accurate diagnosis and classification of patients is essential. These PAH therapies improve exercise capacity and pulmonary haemodynamics, but their overall effect on the right ventricle remains unclear. Current practice in the UK is to assess treatment response with 6-minute walk test and NYHA functional class, neither of which truly reflects RV function. Cardiac magnetic resonance (CMR) imaging has been established as the gold standard for the evaluation of right ventricular structure and function, but it also allows a non-invasive and accurate study of the left heart. The aims of this thesis were to investigate the use of CMR in the diagnosis of PH, in the assessment of treatment response, and in predicting survival in idiopathic and connective-tissue disease associated PAH. In Chapter 3, a left atrial volume (LAV) threshold of 43 ml/m2 measured with CMR was able to distinguish idiopathic PAH from PH due to HFpEF (sensitivity 97%, specificity 100%). In Chapter 4, disease-targeted PAH therapy resulted in significant improvements in RV and left ventricular ejection fraction (p<0.001 and p=0.0007, respectively), RV stroke volume index (p<0.0001), and left ventricular end-diastolic volume index (p=0.0015). These corresponded to observed improvements in functional class and exercise capacity, although correlation coefficients between Δ 6MWD and Δ RVEF or Δ LVEDV were low. Finally, in Chapter 5, one-year and three-year survival was worse in CTD-PAH (75% and 53%) than in IPAH (83% and 74%), despite similar baseline clinical characteristics, lung function, pulmonary haemodynamics and treatment. Baseline right ventricular stroke volume index was an independent predictor of survival in both conditions. The presence of LV systolic dysfunction was of prognostic significance in CTD-PAH but not IPAH, and a higher LAV was observed in CTD-PAH suggesting a potential contribution from LV diastolic dysfunction in this group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Reliable diagnostic measures for the evaluation of left ventricular systolic performance in the setting of altered myocardial loading characteristics in sickle cell anaemia remains unresolved. Objective: The study was designed to assess left ventricular systolic function in adult sickle cell patients using non-invasive endsystolic stress – end-systolic volume index ratio. Methods: A descriptive cross sectional comparative study was done using 52 patients recruited at the adult sickle cell anaemia clinic of the University of Nigeria Teaching Hospital Enugu. An equal number of age and sex-matched healthy volunteers served as controls. All the participants had haematocrit estimation, haemoglobin electrophoresis, as well as echocardiographic evaluation. Result: The mean age of the patients and controls were 23.93 ± 5.28 (range 18-42) and 24.17 ± 4.39 (range 19 -42) years respectively, (t = 0.262; p= .794). No significant difference was seen in estimate of fractional shortening, and ejection fraction. The cardiac out-put, cardiac index and velocity of circumferential shortening were all significantly increased in the cases compared with the controls. The end systolic stress – end systolic volume index ratio (ESS/ESVI) was significantly lower in cases than controls. There were strong positive correlation between the ejection phase indices (ejection fraction and fractional shortening) and end systolic stress and ESS/ESVI. Conclusion: The study findings suggest the presence of left ventricular systolic dysfunction in adult sickle cell anaemia. This is best detected using the loading-pressures independent force-length relationship expressed in ESS/ESVI ratio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado Integrado em Medicina Veterinária

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the cardioprotective effects and possible mechanisms of Dan-Yang-Fu-Xin decoction (DYFX) in a rat chronic heart failure (CHF). Methods: A CHF rat model induced by ligation of the left anterior descending coronary artery was used to investigate the cardioprotective effects of DYFX. After intragastric administration for 8 weeks, several functional cardiac indices, including fractional shortening (FS), ejection fraction (EF), heart rate (HR) and cardiac output (CO) were assessed by ultrasound examination. Subsequently, inflammatory markers, viz, interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α), myocardial enzymes, namely, lactate dehydrogenase (LDH) and creatine kinase (CK), were also assessed by enzyme-linked immunosorbent assay (ELISA). Results: Intragastric administration of DYFX (200, 400 and 600 mg/kg) significantly reversed the decrease in body weight and increase in cardiac weight (p < 0.05) induced by CHF. Treatment with DYFX also significantly reversed EF, FS, HR, and CO changes in CHF rats. In addition, DYFX inhibited the two inflammatory cytokines (TNF-α and IL-6) and myocardial enzymes (CK and LDH), suggesting that these effects may include the mechanisms of cardioprotectiion involved in attenuation of CHF. Conclusion: DYFX possesses cardioprotective effects involving CHF. The protective mechanisms may include the suppression of expression of inflammatory mediators and myocardial enzymes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis presents investigations of chemical reactions occurring at the liquid/vapor interface studied using novel sampling methodologies coupled with detection by mass spectrometry. Chapters 2 and 3 utilize the recently developed technique of field-induced droplet ionization mass spectrometry (FIDI-MS), in which the application of a strong electric field to a pendant microliter droplet results in the ejection of highly charged progeny droplets from the liquid surface. In Chapter 2, this method is employed to study the base-catalyzed dissociation of a surfactant molecule at the liquid/vapor interface upon uptake of ammonia from the gas phase. This process is observed to occur without significant modulation of the bulk solution pH, suggesting a transient increase in surface pH following the uptake of gaseous ammonia. Chapter 3 presents real-time studies of the oxidation of the model tropospheric organic compound glycolaldehyde by photodissociation of iron (III) oxalate complexes. The oxidation products of glycolaldehyde formed in this process are identified, and experiments in a deoxygenated environment identify the role of oxygen in the oxidation pathway and in the regeneration of iron (III) following photo-initiated reduction. Chapter 4 explores alternative methods for the study of heterogeneous reaction processes by mass spectrometric sampling from liquid surfaces. Bursting bubble ionization (BBI) and interfacial sampling with an acoustic transducer (ISAT) generate nanoliter droplets from a liquid surface that can be sampled via the atmospheric pressure interface of a mass spectrometer. Experiments on the oxidation of oleic acid by ozone using ISAT are also presented. Chapters 5 and 6 detail mechanistic studies and applications of free-radical-initiated peptide sequencing (FRIPS), a technique employing gas-phase free radical chemistry to the sequencing of peptides and proteins by mass spectrometry. Chapter 5 presents experimental and theoretical studies on the anomalous mechanism of dissociation observed in the presence of serine and threonine residues in peptides. Chapter 6 demonstrates the combination of FRIPS with ion mobility-mass spectrometry (IM-MS) for the separation of isomeric peptides.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La fraction d’éjection du ventricule gauche est un excellent marqueur de la fonction cardiaque. Plusieurs techniques invasives ou non sont utilisées pour son calcul : l’angiographie, l’échocardiographie, la résonnance magnétique nucléaire cardiaque, le scanner cardiaque, la ventriculographie radioisotopique et l’étude de perfusion myocardique en médecine nucléaire. Plus de 40 ans de publications scientifiques encensent la ventriculographie radioisotopique pour sa rapidité d’exécution, sa disponibilité, son faible coût et sa reproductibilité intra-observateur et inter-observateur. La fraction d’éjection du ventricule gauche a été calculée chez 47 patients à deux reprises, par deux technologues, sur deux acquisitions distinctes selon trois méthodes : manuelle, automatique et semi-automatique. Les méthodes automatique et semi-automatique montrent dans l’ensemble une meilleure reproductibilité, une plus petite erreur standard de mesure et une plus petite différence minimale détectable. La méthode manuelle quant à elle fournit un résultat systématiquement et significativement inférieur aux deux autres méthodes. C’est la seule technique qui a montré une différence significative lors de l’analyse intra-observateur. Son erreur standard de mesure est de 40 à 50 % plus importante qu’avec les autres techniques, tout comme l’est sa différence minimale détectable. Bien que les trois méthodes soient d’excellentes techniques reproductibles pour l’évaluation de la fraction d’éjection du ventricule gauche, les estimations de la fiabilité des méthodes automatique et semi-automatique sont supérieures à celles de la méthode manuelle.