993 resultados para perfusion cérébrale


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – Os estudos Gated – Single Photon Emission Computed Tomography (SPECT) são uma das técnicas de imagiologia cardíaca que mais evoluiu nas últimas décadas. Para a análise das imagens obtidas, a utilização de softwares de quantificação leva a um aumento da reprodutibilidade e exatidão das interpretações. O objetivo deste estudo consiste em avaliar, em estudos Gated-SPECT, a variabilidade intra e interoperador de parâmetros quantitativos de função e perfusão do miocárdio, obtidos com os softwares Quantitative Gated SPECT (QGS) e Quantitative Perfusion SPECT (QPS). Material e métodos – Recorreu-se a uma amostra não probabilística por conveniência de 52 pacientes, que realizaram estudos Gated-SPECT do miocárdio por razões clínicas e que integravam a base de dados da estação de processamento da Xeleris da ESTeSL. Os cinquenta e dois estudos foram divididos em dois grupos distintos: Grupo I (GI) de 17 pacientes com imagens com perfusão do miocárdio normal; Grupo II (GII) de 35 pacientes que apresentavam defeito de perfusão nas imagens Gated-SPECT. Todos os estudos foram processados 5 vezes por 4 operadores independentes (com experiência de 3 anos em Serviços de Medicina Nuclear com casuística média de 15 exames/semana de estudos Gated-SPECT). Para a avaliação da variabilidade intra e interoperador foi utilizado o teste estatístico de Friedman, considerando α=0,01. Resultados e discussão – Para todos os parâmetros avaliados, os respectivos valores de p não traduziram diferenças estatisticamente significativas (p>α). Assim, não foi verificada variabilidade intra ou interoperador significativa no processamento dos estudos Gated-SPECT do miocárdio. Conclusão – Os softwares QGS e QPS são reprodutíveis na quantificação dos parâmetros de função e perfusão avaliados, não existindo variabilidade introduzida pelo operador.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – A tomografia de emissão de fotão simples sincronizada com o sinal eletrocardiográfico (Gated-SPECT) é essencial para a avaliação conjunta da perfusão e da função ventricular esquerda (VE) do miocárdio. Objetivo – Investigar a relação entre a função VE e o índice de captação (IC) miocárdio/pulmão direito (M/PD) e M/P esquerdo (M/PE) nos estudos Gated-SPECT com 99mTc-Tetrofosmina. Metodologia – Amostra de 32 pacientes que realizaram estudos Gated-SPECT por indicação clínica, sendo subdividida em dois grupos: Grupo I (GI) – pacientes com a informação clínica de enfarte agudo do miocárdio (EAM); Grupo II (GII) – pacientes com a informação clínica de isquemia. Por cada paciente adquiriram-se imagens estáticas torácico-abdominais e dois estudos Gated-SPECT do miocárdio (protocolo de um dia esforço/repouso). Nas imagens estáticas definiram-se regiões de interesse (Regions of interest – ROI) para calcular os IC. Nos estudos Gated-SPECT utilizou-se o software Quantitative Gated SPECT/Quantitative Perfusion SPECT para calcular a Fração de Ejeção do Ventrículo Esquerdo (FEVE). Efetuou-se análise estatística descritiva para caracterização da amostra. Aplicou-se o teste de Spearman para avaliar a correlação entre a FEVE e os IC por grupo de pacientes. O Teste de Willcoxon foi usado para comparar FEVE em repouso e em esforço. Resultados – Nos estudos Gated-SPECT em esforço não se verificou correlação estatisticamente significativa entre a FEVE e os IC, para GI e GII; em repouso existe correlação positiva estatisticamente significativa entre a FEVE e os IC, para GI; para GII não se verificou correlação. Na comparação dos valores de FEVE em esforço e repouso nos dois grupos constatou-se a existência de diferenças estatisticamente significativas, sendo a FEVE em Esforço

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Myocardial Perfusion Gated Single Photon Emission Tomography (Gated-SPET) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV). The purpose of this study is to evaluate the influence of the total number of counts acquired from myocardium, in the calculation of myocardial functional parameters using routine software procedures. Methods: Gated-SPET studies were simulated using Monte Carlo GATE package and NURBS phantom. Simulated data were reconstructed and processed using the commercial software package Quantitative Gated-SPECT. The Bland-Altman and Mann-Whitney-Wilcoxon tests were used to analyze the influence of the number of total counts in the calculation of LV myocardium functional parameters. Results: In studies simulated with 3MBq in the myocardium there were significant differences in the functional parameters: Left ventricular ejection fraction (LVEF), end-systolic volume (ESV), Motility and Thickness; between studies acquired with 15s/projection and 30s/projection. Simulations with 4.2MBq show significant differences in LVEF, end-diastolic volume (EDV) and Thickness. Meanwhile in the simulations with 5.4MBq and 8.4MBq the differences were statistically significant for Motility and Thickness. Conclusion: The total number of counts per simulation doesn't significantly interfere with the determination of Gated-SPET functional parameters using the administered average activity of 450MBq to 5.4MBq in myocardium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Ramo de especialização: Radiofarmácia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Myocardial perfusion gated-single photon emission computed tomography (gated-SPECT) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. The aim of this study is to analyze the influence of counts/pixel and concomitantly the total counts in the myocardium for the calculation of myocardial functional parameters. Material and methods: Gated-SPECT studies were performed using a Monte Carlo GATE simulation package and the NCAT phantom. The simulations of these studies use the radiopharmaceutical 99mTc-labeled tracers (250, 350, 450 and 680MBq) for standard patient types, effectively corresponding to the following activities of myocardium: 3, 4.2, 5.4-8.2MBq. All studies were simulated using 15 and 30s/projection. The simulated data were reconstructed and processed by quantitative-gated-SPECT software, and the analysis of functional parameters in gated-SPECT images was done by using Bland-Altman test and Mann-Whitney-Wilcoxon test. Results: In studies simulated using different times (15 and 30s/projection), it was noted that for the activities for full body: 250 and 350MBq, there were statistically significant differences in parameters Motility and Thickness. For the left ventricular ejection fraction (LVEF), end-systolic volume (ESV) it was only for 250MBq, and 350MBq in the end-diastolic volume (EDV), while the simulated studies with 450 and 680MBq showed no statistically significant differences for global functional parameters: LVEF, EDV and ESV. Conclusion: The number of counts/pixel and, concomitantly, the total counts per simulation do not significantly interfere with the determination of gated-SPECT functional parameters, when using the administered average activity of 450MBq, corresponding to the 5.4MBq of the myocardium, for standard patient types.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: multimodality environment; requirement for greater understanding of the imaging technologies used, the limitations of these technologies, and how to best interpret the results; dose optimization; introduction of new techniques; current practice and best practice; incidental findings, in low-dose CT images obtained as part of the hybrid imaging process, are an increasing phenomenon with advancing CT technology; resultant ethical and medico-legal dilemmas; understanding limitations of these procedures important when reporting images and recommending follow-up; free-response observer performance study was used to evaluate lesion detection in low-dose CT images obtained during attenuation correction acquisitions for myocardial perfusion imaging, on two hybrid imaging systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Germfree (GF and conventional (CV) mice were infected intraperitoneally with GF cercariae of Schistosoma mansoni and kept for six weeks. Twenty four hours before killing, they were injected with [³H]-thymidine. Schistosoma worms, harvested after perfusion of portal system, were counted as well as eggs from liver and intestines. Liver was also used for DNA, protein, and collagen determinations. [³H] -Thymidine incorporation and collagen determinations were used to establish the indices given by the difference between their contents in infected and control animals and expressed per thousand eggs in liver. The recovery of worms in GF mice was around twice as much as in CV ones, and the total number of eggs was higher in the liver of GF animals. No hypertrophy of liver cells was observed by the ratio protein/DNA, but [³H]-thymidine incorporation into DNA was higher than in controls in both GF and CV infected animals. The [³H]-thymidine and collagen indices were lower in GF animals which indicate a more discrete cellular replication and smaller collagen content in relation to the number of eggs present in livers of these mice. It was concluded that the disease seems to be less severe in GF animals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the first in vivo studies of cerebral function with radionuclides by Ingvar and Lassen, nuclear medicine (NM) brain applications have evolved dramatically, with marked improvements in both methods and tracers. Consequently it is now possible to assess not only cerebral blood flow and energy metabolism but also neurotransmission. Planar functional imaging was soon substituted by single-photon emission computed tomography (SPECT) and positron emission tomography (PET); it now has limited application in brain imaging, being reserved for the assessment of brain death.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The acquisition of a Myocardial Perfusion image (MPI) is of great importance for the diagnosis of the coronary artery disease, since it allows to evaluate which areas of the heart aren’t being properly perfused, in rest and stress situations. This exam is greatly influenced by photon attenuation which creates image artifacts and affects quantification. The acquisition of a Computerized Tomography (CT) image makes it possible to get an atomic images which can be used to perform high-quality attenuation corrections of the radiopharmaceutical distribution, in the MPI image. Studies show that by using hybrid imaging to perform diagnosis of the coronary artery disease, there is an increase on the specificity when evaluating the perfusion of the right coronary artery (RCA). Using an iterative algorithm with a resolution recovery software for the reconstruction, which balances the image quality, the administered activity and the scanning time, we aim to evaluate the influence of attenuation correction on the MPI image and the outcome in perfusion quantification and imaging quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Gestão e Avaliação de Tecnologias em Saúde

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – A cintigrafia de perfusão do miocárdio (CPM) desempenha um importante papel no diagnóstico, avaliação e seguimento de pacientes com doença arterial coronária, sendo o seu processamento realizado maioritariamente de forma semiautomática. Uma vez que o desempenho dos técnicos de medicina nuclear (TMN) pode ser afetado por fatores individuais e ambientais, diferentes profissionais que processem os mesmos dados poderão obter diferentes estimativas dos parâmetros quantitativos (PQ). Objetivo – Avaliar a influência da experiência profissional e da função visual no processamento semiautomático da CPM. Analisar a variabilidade intra e interoperador na determinação dos PQ funcionais e de perfusão. Metodologia – Selecionou-se uma amostra de 20 TMN divididos em dois grupos, de acordo com a sua experiência no software Quantitative Gated SPECTTM: Grupo A (GA) – TMN ≥600h de experiência e Grupo B (GB) – TMN sem experiência. Submeteram-se os TMN a uma avaliação ortóptica e ao processamento de 21 CPM, cinco vezes, não consecutivas. Considerou-se uma visão alterada quando pelo menos um parâmetro da função visual se encontrava anormal. Para avaliar a repetibilidade e a reprodutibilidade recorreu-se à determinação dos coeficientes de variação, %. Na comparação dos PQ entre operadores, e para a análise do desempenho entre o GA e GB, aplicou-se o Teste de Friedman e de Wilcoxon, respetivamente, considerando o processamento das mesmas CPM. Para a comparação de TMN com visão normal e alterada na determinação dos PQ utilizou-se o Teste Mann-Whitney e para avaliar a influência da visão para cada PQ recorreu-se ao coeficiente de associação ETA. Diferenças estatisticamente significativas foram assumidas ao nível de significância de 5%. Resultados e Discussão – Verificou-se uma reduzida variabilidade intra (<6,59%) e inter (<5,07%) operador. O GB demonstrou ser o mais discrepante na determinação dos PQ, sendo a parede septal (PS) o único PQ que apresentou diferenças estatisticamente significativas (zw=-2,051, p=0,040), em detrimento do GA. No que se refere à influência da função visual foram detetadas diferenças estatisticamente significativas apenas na fração de ejeção do ventrículo esquerdo (FEVE) (U=11,5, p=0,012) entre TMN com visão normal e alterada, contribuindo a visão em 33,99% para a sua variação. Denotaram-se mais diferenças nos PQ obtidos em TMN que apresentam uma maior incidência de sintomatologia ocular e uma visão binocular diminuída. A FEVE demonstrou ser o parâmetro mais consistente entre operadores (1,86%). Conclusão – A CPM apresenta-se como uma técnica repetível e reprodutível, independente do operador. Verificou-se influência da experiência profissional e da função visual no processamento semiautomático da CPM, nos PQ PS e FEVE, respetivamente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of anesthetic drugs on the localization of adult worms in albino mice was compared. The animals with 56 days of infection were anesthetized with pentobarbital sodium, ether or chlorophorm. Perfusion was carried out immediately after, recovering the worms and classifying them in relation to their localization on the liver or portal vein and the mesenteric veins. Our results showed that pentobarbital sodium produced a greater displacement of the worms to the liver (89%) than ether (76%) and chlorophorm (34%) did, when compared to the control group (22%). The difference between pentobarbital sodium and ether was significant (p < 0.05). We suggest that anesthetic drugs may not be used in studies on the distribution of adult worms in several hosts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertation submitted in Faculdade de Ciências e Tecnologia of Universidade Nova de Lisboa for the degree of Master in Biomedical Engineering

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mice transcutaneously infected with about 400 cercariae were submitted to treatment with oxamniquine (400 mg/kg), 24 hours after infection. The recovery of schistosomules, at 4, 24, 48 and 72 hours and 35 days after treatment, showed the activity of the drug on the parasites, thus practically preventing their migration from the skin to the lungs. Worm recovery performed in the lungs (96 hours after treatment) showed recovery means of 0.6 worms/mouse in the treated group and 53.8 in the control group (untreated). The perfusion of the portal system carried out at 35 days after treatment clearly showed the elimination of all the parasites in the treated group, whereas a recovery mean of 144.7 worms/mouse was detected in the control group (untreated). These findings confirm the efficacy of oxamniquine at the skin phase of infection, and also show similarity with the immunization method that uses irradiated cercariae. The practical application of these findings in the medical clinic is discussed too

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mice infected with about 90 cercariae of Schistosoma mansoni (LE strain) were treated during five consecutive days with dexamethasone (50 mg/Kg, subcutaneously), starting on the 42th day of infection. Groups of five mice were then daily sacrificed from the first day after onset of treatment until the first day after. The perfusion of the portal system was performed and a piece of the intestine was processed for qualitative and quantitative oograms. This treatment carries to larger numbers of eggs in the tissues of treated mice, when compared with untreated groups. No changes were observed in the kinetics of oviposition, as all stages of viable eggs were observed in the tissues of treated and control mice. These data reinforce the hypothesis of a partial blockade of the egg excretion in immunossupressed mice.