997 resultados para internal tapered connection
Resumo:
The theoretical investigation of the coupling efficiency of a laser diode to a single mode fiber via a hemispherical lens on the tip of the tapered fiber in the presence of possible transverse offset and angular mismatch is reported.Without the misalignment,coupling efficiency increases with the decreasing of taper length.With the misalignment,this relation is that the coupling efficiency decreases with each kind of offset.
Resumo:
A novel structure of spot-size converter is designed to allow low loss and large alignment tolerance between single-mode rib waveguide devices and fiber arrays theoretically. The spot-size converter consists of a tapered rib core region and a double-cladding region. Through optimizing parameters,an expanded mode field can be tightly confined in the inner cladding and thus radiation loss be reduced largely at the tapered region. The influence of refractive index and thickness of the inner cladding on coupling loss is analyzed in particular. A novel,easy method of fabricating tapered rib spot-size converter based on silicon-on-insulator material is proposed.
Resumo:
The authors have designed and fabricated 2x2 parabolically tapered MMI coupler with large cross-section and large space between difference ports using Silicon-on-Insulator ( SOI) technology. The devices demonstrate a minimum uniformity of 0.8dB and 30% shorter than the straight MMI coupler.
Resumo:
1.5 mu m DFB LD butt-joint integrated with vertical tapered spotsize converter was fabricated by LP-MOVPE. The vertical far field angle (FWHM) was decreased from 34degrees to 10degrees the threshold currents was as low as 19.8mA, the output power was 9.6mw at 100mA without HR coating and the SMSR was 35.8dB. The 1-dBm misalignment tolerance was 3.2 mu m, while the counterpart of the device without SSC was 2.2 mu m.
Resumo:
Fourier modal method incorporating staircase approximation is used to study tapered crossed subwavelength gratings in this paper. Three intuitive formulations of eigenvalue functions originating from the prototype are presented, and their convergences are compared through numerical calculation. One of them is found to be suitable in modeling the diffraction efficiency of the circular tapered crossed subwavelength gratings without high absorption, and staircase approximation is further proven valid for non-highly-absorption tapered gratings. This approach is used to simulate the "moth-eye" antireflection surface on silicon, and the numerical result agrees well with the experimental one.
Resumo:
A scheme based on a W-shaped axicon mirror device for total-internal-reflection fluorescence microscopy (TIRFM) is presented. This approach combines the advantages of higher efficiency compared with traditional TIRFM, adjustable illumination area, and simple switching between wide-field and TIRF imaging modes. TIRF images obtained with this approach are free of shadow artifacts and of interference fringes. Example micrographs of fluorescently labeled polystyrene beads, of Convallaria majalis tissue, and of Propidium-iodide-labeled Chinese hamster ovary cells are shown, and the capabilities of the scheme are discussed. (C) 2010 Optical Society of America
Resumo:
An approximate theoretical expression for the current induced by long internal solitary waves is presented when the ocean is continuously or two-layer stratified. Particular attention is paid to characterizing velocity fields in terms of magnitude, flow components, and their temporal evolution/spatial distribution. For the two-layer case, the effects of the upper/lower layer depths and the relative layer density difference upon the induced current are further studied. The results show that the horizontal components are basically uniform in each layer with a shear at the interface. In contrast, the vertical counterparts vary monotonically in the direction of the water depth in each layer while they change sign across the interface or when the wave peak passes through. In addition, though the vertical components are generally one order of magnitude smaller than the horizontal ones, they can never be neglected in predicting the heave response of floating platforms in gravitationally neutral balance. Comparisons are made between the partial theoretical results and the observational field data. Future research directions regarding the internal wave induced flow field are also indicated.
Resumo:
The generation of internal gravity waves by barotropic tidal flow passing over a two-dimensional topography is investigated. Rather than calculating the conversion of tidal energy, this study focuses on delineating the geometric characteristics of the spatial structure of the resulting internal wave fields (i.e., the configurations of the internal beams and their horizontal projections) which have usually been ignored. it is found that the various possible wave types can be demarcated by three characteristic frequencies: the tidal frequency, wo; the buoyancy frequency, N; and the vertical component of the Coriolis vector or earth's rotation.f. When different possibilities arising from the sequence of these frequencies are considered, there occur 12 kinds of wave structures in the full 3D space in contrast to the 5 kinds identified by the 2D theory. The constant wave phase lines may form as ellipses or hyperbolic lines on the horizontal plane, provided the buoyancy frequency is greater or less than the tidal frequency. The effect that stems from the consideration of the basic flow is also found, which not only serves as the reason for the occurrence of higtter harmonics but also increases the wave strength in the direction of basic flow. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Pellet target is one of the main candidate targets in CSRm (cooler storage ring’s main ring) for hadron physics studies. Pellet speed is an important physical parameter for the target. Larger pellet speed could shorten the interacting time interval between the pellet and the cyclotron beam, and thus results in a small temperature variation for the pellet. This could make the pellet facility work in a stable condition. A fluid dynamic simulation was carried out for the pellet speed, and it was found that the maximum speed for the target pellet may be restricted to about 100 m/s even if all working parameters were set to their optimal values.