925 resultados para cache coherence protocols
Resumo:
by Lucien Wolf
Resumo:
We present an application and sample independent method for the automatic discrimination of noise and signal in optical coherence tomography Bscans. The proposed algorithm models the observed noise probabilistically and allows for a dynamic determination of image noise parameters and the choice of appropriate image rendering parameters. This overcomes the observer variability and the need for a priori information about the content of sample images, both of which are challenging to estimate systematically with current systems. As such, our approach has the advantage of automatically determining crucial parameters for evaluating rendered image quality in a systematic and task independent way. We tested our algorithm on data from four different biological and nonbiological samples (index finger, lemon slices, sticky tape, and detector cards) acquired with three different experimental spectral domain optical coherence tomography (OCT) measurement systems including a swept source OCT. The results are compared to parameters determined manually by four experienced OCT users. Overall, our algorithm works reliably regardless of which system and sample are used and estimates noise parameters in all cases within the confidence interval of those found by observers.
Resumo:
Retinal vein occlusion is a leading cause of visual impairment. Experimental models of this condition based on laser photocoagulation of retinal veins have been described and extensively exploited in mammals and larger rodents such as the rat. However, few reports exist on the use of this paradigm in the mouse. The objective of this study was to investigate a model of branch and central retinal vein occlusion in the mouse and characterize in vivo longitudinal retinal morphology alterations using spectral domain optical coherence tomography. Retinal veins were experimentally occluded using laser photocoagulation after intravenous application of Rose Bengal, a photo-activator dye enhancing thrombus formation. Depending on the number of veins occluded, variable amounts of capillary dropout were seen on fluorescein angiography. Vascular endothelial growth factor levels were markedly elevated early and peaked at day one. Retinal thickness measurements with spectral domain optical coherence tomography showed significant swelling (p<0.001) compared to baseline, followed by gradual thinning plateauing two weeks after the experimental intervention (p<0.001). Histological findings at day seven correlated with spectral domain optical coherence tomography imaging. The inner layers were predominantly affected by degeneration with the outer nuclear layer and the photoreceptor outer segments largely preserved. The application of this retinal vein occlusion model in the mouse carries several advantages over its use in other larger species, such as access to a vast range of genetically modified animals. Retinal changes after experimental retinal vein occlusion in this mouse model can be non-invasively quantified by spectral domain optical coherence tomography, and may be used to monitor effects of potential therapeutic interventions.
Resumo:
Purpose: Selective retina therapy (SRT) has shown great promise compared to conventional retinal laser photocoagulation as it avoids collateral damage and selectively targets the retinal pigment epithelium (RPE). Its use, however, is challenging in terms of therapy monitoring and dosage because an immediate tissue reaction is not biomicroscopically discernibel. To overcome these limitations, real-time optical coherence tomography (OCT) might be useful to monitor retinal tissue during laser application. We have thus evaluated a proprietary OCT system for its capability of mapping optical changes introduced by SRT in retinal tissue. Methods: Freshly enucleated porcine eyes, covered in DMEM upon collection were utilized and a total of 175 scans from ex-vivo porcine eyes were analyzed. The porcine eyes were used as an ex-vivo model and results compared to two time-resolved OCT scans, recorded from a patient undergoing SRT treatment (SRT Vario, Medical Laser Center Lübeck). In addition to OCT, fluorescin angiography and fundus photography were performed on the patient and OCT scans were subsequently investigated for optical tissue changes linked to laser application. Results: Biomicroscopically invisible SRT lesions were detectable in OCT by changes in the RPE / Bruch's complex both in vivo and the porcine ex-vivo model. Laser application produced clearly visible optical effects such as hyperreflectivity and tissue distortion in the treated retina. Tissue effects were even discernible in time-resolved OCT imaging when no hyper-reflectivity persisted after treatment. Data from ex-vivo porcine eyes showed similar to identical optical changes while effects visible in OCT appeared to correlate with applied pulse energy, leading to an additional reflective layer when lesions became visible in indirect ophthalmoscopy. Conclusions: Our results support the hypothesis that real-time high-resolution OCT may be a promising modality to obtain additional information about the extent of tissue damage caused by SRT treatment. Data shows that our exvivo porcine model adequately reproduces the effects occurring in-vivo, and thus can be used to further investigate this promising imaging technique.
Resumo:
AIMS The purpose of the present study was to investigate the relationship between in-stent neoatherosclerosis (NA) and native atherosclerosis progression of untreated coronary segments. METHODS AND RESULTS In-stent NA was assessed by optical coherence tomography (OCT) among patients included in the SIRTAX-LATE OCT study 5 years after drug-eluting stent (DES) (sirolimus-eluting and paclitaxel-eluting stents) implantation. Neoatherosclerosis was defined as the presence of fibroatheroma or fibrocalcific plaque within the neointima of stented segments with a longitudinal extension >1.0 mm. Atherosclerosis progression in untreated native coronary segments was evaluated by serial quantitative coronary angiography (QCA). The change in minimal lumen diameter (MLD) was serially assessed within matched segments at baseline and 5-year angiographic follow-up. The key clinical endpoint was non-target lesion (non-TL) revascularization throughout 5 years. A total of 88 patients with 88 lesions were available for OCT analysis 5 years after DES implantation. In-stent NA was observed in 16% of lesions with the majority of plaques being fibroatheromas (11.4%) followed by fibrocalcific plaques (5.7%). A total of 704 non-TL segments were serially evaluated by QCA. Between baseline and 5-year follow-up, the reduction in MLD was significantly more pronounced in patients with NA (-0.25 mm, 95% CI -0.36 to -0.17 mm) when compared with patients without NA (-0.13 mm, 95% CI -0.17 to -0.10 mm, P = 0.002). Similarly, non-TL revascularization was more frequent in patients with NA (78.6%) when compared with patients without NA (44.6%, P = 0.028) throughout 5 years. CONCLUSIONS In-stent NA is more common among patients with angiographic and clinical evidence of native atherosclerosis progression suggesting similar pathophysiological mechanisms.SIRTAX trial is registered at http://www.clinicaltrials.gov/ct2/show/NCT00617084.
Resumo:
PURPOSE Graves' orbitopathy (GO) is an extraocular eye disease with symptoms ranging from minor discomfort from dry eyes to strabismus and visual loss. One of the hallmarks of active GO is visible hyperemia at the insertion of the extraocular muscles. The aim of the present study was to evaluate the use of enhanced-depth imaging spectral domain anterior segment optical coherence tomography (EDI SD AS-OCT) for detecting pathological changes in horizontal recti muscles of patients with GO. METHODS Prospective cross sectional study of 27 eyes. Only women were included. EDI AS-OCT was used to measure the thickness of the tendons of the horizontal recti muscles in a predefined area in patients with GO and healthy controls. RESULTS EDI AS-OCT was able to image the tendons of the horizontal recti muscles in both healthy controls and patients suffering from GO. The mean thickness of the medial rectus muscle (MR) tendon was 256.4 μm [±17.13 μm standard deviation (SD)] in the GO group and, therefore, significantly thicker (p = 0.046) than in the healthy group which had a mean thickness of 214.7 μm (±5.516 μm SD). There was no significant difference in the mean thickness of the tendon of the lateral recti muscles (LRs) between these groups. CONCLUSION This is the first report showing that EDI AS-OCT is suitable to detect swelling at the insertion site of the MR muscle in GO. MR tendon thickness may be a useful parameter to monitor activity in these patients.
Resumo:
Trade, investment and migration are strongly intertwined, being three key factors in international production. Yet, law and regulation of the three has remained highly fragmented. Trade is regulated by the WTO on the multilateral level, and through preferential trade agreements on the regional and bilateral levels – it is fragmented and complex in its own right. Investment, on the other hand, is mainly regulated through bilateral investment treaties with no strong links to the regulation of trade or migration. And, finally, migration is regulated by a web of different international, regional and bilateral agreements which focus on a variety of different aspects of migration ranging from humanitarian to economic. The problems of institutional fragmentation in international law are well known. There is no organizational forum for coherent strategy-making on the multilateral level covering all three areas. Normative regulations may thus contradict each other. Trade regulation may bring about liberalization of access for service providers, but eventually faces problems in recruiting the best people from abroad. Investors may withdraw investment without being held liable for disruptions to labour and to the livelihood and infrastructure of towns and communities affected by disinvestment. Finally, migration policies do not seem to have a significant impact as long as trade policies and investment policies are not working in a way that is conducive to reducing migration pressure, as trade and investment are simply more powerful on the regulatory level than migration. This chapter addresses the question as to how fragmentation of the three fields could be reme-died and greater coherence between these three areas of factor allocation in international economic relations and law could be achieved. It shows that migration regulation on the international level is lagging behind that on trade and investment. Stronger coordination and consideration of migration in trade and investment policy, and stronger international cooperation in migration, will provide the foundations for a coherent international architecture in the field.
Resumo:
BACKGROUND To investigate anterior scleral thickness in a cohort of healthy subjects using enhanced depth imaging anterior segment optical coherence tomography. METHODS Observational case series. The mean scleral thickness in the inferonasal, inferotemporal, superotemporal, and superonasal quadrant was measured 2 mm from the scleral spur on optical coherence tomography in healthy volunteers. RESULTS Fifty-three eyes of 53 Caucasian patients (25 male and 28 female) with an average age of 48.6 years (range: 18 to 92 years) were analysed. The mean scleral thickness was 571 μm (SD 84 μm) in the inferonasal quadrant, 511 μm (SD 80 μm) in the inferotemporal quadrant, 475 (SD 81 μm) in the superotemporal, and 463 (SD 64 μm) in the superonasal quadrant. The mean scleral thickness was significantly different between quadrants (p < 0.0001, repeated measures one-way ANOVA). The association between average scleral thickness and age was statistically significant (p < 0.0001, Pearson r = 0.704). CONCLUSIONS Enhanced depth imaging optical coherence tomography revealed the detailed anatomy of the anterior sclera and enabled non-invasive measurements of scleral thickness in a non-contact approach. The anterior scleral thickness varies significantly between quadrants, resembling the spiral of Tillaux. An association of increasing scleral thickness with age was found.
Resumo:
Ecological research and monitoring of lacustrine ecosystems often requires a whole-lake assessment of fish communities. Gillnet sampling offers an efficient means of estimating abundance, biomass and fish community composition. However the choice of gillnet sampling protocol may influence lake characterization via physical properties of the nets and allocation of sampling effort between littoral, benthic and pelagic habitats. This paper compares two commonly used, whole-lake sampling protocols applied across 17 prealpine, subalpine and alpine European lakes ranging widely in size, depth and altitude to determine their relative strength for research and management applications. Effort-corrected estimates of abundance, biomass and species richness were correlated between the protocols and both distinguished the trout-dominated alpine communities from subalpine and prealpine lakes dominated by whitefish and perch. A considerable amount of variance remained unexplained between the two protocols however, which seemed to correspond with differences in the proportion of effort among benthic and pelagic habitats. We suggest that both the European standard (CEN) and vertical (VERT) netting protocols are suitable for assessing ecological status and monitoring changes in lake fish communities through time. However the details of each protocol should be kept in mind when comparing fish communities between lakes. Mesh sizes used in CEN nets produce a more even size frequency distribution, suggesting that this protocol is most appropriate for assessing size structure of fish assemblages. The high proportion of netting effort in benthic habitats shallower than 70 m depth under the CEN protocol means that, particularly in larger lakes, outcomes will be disproportionately influenced by the ecological condition of this habitat. The VERT protocol presumably provides a more accurate estimate of whole-lake CPUE and community composition because effort, in terms of net area, is more evenly distributed across the entire volume of the lake. This is particularly important in large and deep lakes where pelagic habitats occupy a high proportion of the lake volume.
Resumo:
Purpose: Selective retina therapy (SRT) is a novel treatment for retinal pathologies, solely targeting the retinal pigment epithelium (RPE). During SRT, the detection of an immediate tissue reaction is challenging as tissue effects remain limited to intracellular RPE photodisruption. Time-resolved ultra-high axial resolution optical coherence tomography (OCT) is thus evaluated for the monitoring of dynamic optical changes at and around the RPE during SRT. Methods: An experimental OCT system with an ultra-high axial resolution of 1.78 µm was combined with an SRT system and time-resolved OCT M-scans of the target area were recorded from four patients undergoing SRT. OCT scans were analyzed and OCT morphology was correlated with findings in fluorescein angiography, fundus photography and cross-sectional OCT. Results: In cases where the irradiation caused RPE damage proven by fluorescein angiography, the lesions were well discernible in time-resolved OCT images but remained invisible in fundus photography and cross-sectional OCT acquired after treatment. If RPE damage was introduced, all applied SRT pulses led to detectable signal changes in the time-resolved OCT images. The extent of optical signal variation seen in the OCT data appeared to scale with the applied SRT pulse energy. Conclusion: The first clinical results proved that successful SRT irradiation induces detectable changes in the OCT M-scan signal while it remains invisible in conventional ophthalmoscopic imaging. Thus, real-time high-resolution OCT is a promising modality to monitor and analyze tissue effects introduced by selective retina therapy and may be used to guide SRT in an automatic feedback mode.
Resumo:
PURPOSE Quantification of retinal layers using automated segmentation of optical coherence tomography (OCT) images allows for longitudinal studies of retinal and neurological disorders in mice. The purpose of this study was to compare the performance of automated retinal layer segmentation algorithms with data from manual segmentation in mice using the Spectralis OCT. METHODS Spectral domain OCT images from 55 mice from three different mouse strains were analyzed in total. The OCT scans from 22 C57Bl/6, 22 BALBc, and 11 C3A.Cg-Pde6b(+)Prph2(Rd2) /J mice were automatically segmented using three commercially available automated retinal segmentation algorithms and compared to manual segmentation. RESULTS Fully automated segmentation performed well in mice and showed coefficients of variation (CV) of below 5% for the total retinal volume. However, all three automated segmentation algorithms yielded much thicker total retinal thickness values compared to manual segmentation data (P < 0.0001) due to segmentation errors in the basement membrane. CONCLUSIONS Whereas the automated retinal segmentation algorithms performed well for the inner layers, the retinal pigmentation epithelium (RPE) was delineated within the sclera, leading to consistently thicker measurements of the photoreceptor layer and the total retina. TRANSLATIONAL RELEVANCE The introduction of spectral domain OCT allows for accurate imaging of the mouse retina. Exact quantification of retinal layer thicknesses in mice is important to study layers of interest under various pathological conditions.
Resumo:
The risk of a financial position is usually summarized by a risk measure. As this risk measure has to be estimated from historical data, it is important to be able to verify and compare competing estimation procedures. In statistical decision theory, risk measures for which such verification and comparison is possible, are called elicitable. It is known that quantile-based risk measures such as value at risk are elicitable. In this paper, the existing result of the nonelicitability of expected shortfall is extended to all law-invariant spectral risk measures unless they reduce to minus the expected value. Hence, it is unclear how to perform forecast verification or comparison. However, the class of elicitable law-invariant coherent risk measures does not reduce to minus the expected value. We show that it consists of certain expectiles.
Resumo:
Large scale acquisitions of land in the Global South have signifi-cantly increased since the millennium. It is often the case that foreign investors are involved in such acquisitions, which are commonly aimed at facilitating the export of commodities. These investments in land tend to transform conventional, rather small scale agricultural systems into large scale, industrial agricultural systems. While investment in ag-riculture in the Global South is much needed, large-scale investments in land often goes hand-in-hand with environmental and human rights re-lated challenges. As a consequence, lawyers need to address questions of sovereignty over natural resources (this paper focuses in particular on land resources), to peoples’ right to self-determination, to the responsi-bilities of the home and host states of the investors, including public-private relationships, and the role of international institutions who are involved, as well as relevant jurisprudence. This paper approaches these questions from the perspective of a theory on policy coherence for sus-tainable development.
Resumo:
The paper revives a theoretical definition of party coherence as being composed of two basic elements, cohesion and factionalism, to propose and apply a novel empirical measure based on spin physics. The simultaneous analysis of both components using a single measurement concept is applied to data representing the political beliefs of candidates in the Swiss general elections of 2003 and 2007, proposing a connection between the coherence of the beliefs party members hold and the assessment of parties being at risk of splitting. We also compare our measure with established polarization measures and demonstrate its advantage with respect to multi-dimensional data that lack clear structure. Furthermore, we outline how our analysis supports the distinction between bottom-up and top-down mechanisms of party splitting. In this way, we are able to turn the intuition of coherence into a defined quantitative concept that, additionally, offers a methodological basis for comparative research of party coherence. Our work serves as an example of how a complex systems approach allows to get a new perspective on a long-standing issue in political science.
Resumo:
PURPOSE To evaluate the sclera and episclera in patients with scleritis and episcleritis using anterior segment optical coherence tomography (AS-OCT). METHODS Cross-sectional prospective case series of 11 consecutive patients with episcleral or scleral inflammatory disease located anterior to the equator. The thickness of the ocular wall (sclera and the episclera) was measured using AS-OCT and compared to the contralateral healthy eye. RESULTS Eleven patients with a mean age of 49.5 years presented with symptomatic scleritis or episcleritis. The mean thickness of the ocular wall in the affected eye was 982 ± 56 μm compared to 790 ± 23 μm (p < 0.05) in the fellow eye. Enhanced-depth AS-OCT showed that the thickening occurred mainly in the episcleral layer in both scleritis and episcleritis. CONCLUSION Enhanced-depth AS-OCT may be a useful tool for imaging scleritis or episcleritis and may serve to monitor therapeutic success in these patients.