994 resultados para Ultrasonic measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims were to determine whether measures of acceleration of the legs and back of dairy cows while they walk could help detect changes in gait or locomotion associated with lameness and differences in the walking surface. In 2 experiments, 12 or 24 multiparous dairy cows were fitted with five 3-dimensional accelerometers, 1 attached to each leg and 1 to the back, and acceleration data were collected while cows walked in a straight line on concrete (experiment 1) or on both concrete and rubber (experiment 2). Cows were video-recorded while walking to assess overall gait, asymmetry of the steps, and walking speed. In experiment 1, cows were selected to maximize the range of gait scores, whereas no clinically lame cows were enrolled in experiment 2. For each accelerometer location, overall acceleration was calculated as the magnitude of the 3-dimensional acceleration vector and the variance of overall acceleration, as well as the asymmetry of variance of acceleration within the front and rear pair of legs. In experiment 1, the asymmetry of variance of acceleration in the front and rear legs was positively correlated with overall gait and the visually assessed asymmetry of the steps (r ≥0.6). Walking speed was negatively correlated with the asymmetry of variance of the rear legs (r=−0.8) and positively correlated with the acceleration and the variance of acceleration of each leg and back (r ≥0.7). In experiment 2, cows had lower gait scores [2.3 vs. 2.6; standard error of the difference (SED)=0.1, measured on a 5-point scale] and lower scores for asymmetry of the steps (18.0 vs. 23.1; SED=2.2, measured on a continuous 100-unit scale) when they walked on rubber compared with concrete, and their walking speed increased (1.28 vs. 1.22m/s; SED=0.02). The acceleration of the front (1.67 vs. 1.72g; SED=0.02) and rear (1.62 vs. 1.67g; SED=0.02) legs and the variance of acceleration of the rear legs (0.88 vs. 0.94g; SED=0.03) were lower when cows walked on rubber compared with concrete. Despite the improvements in gait score that occurred when cows walked on rubber, the asymmetry of variance of acceleration of the front leg was higher (15.2 vs. 10.4%; SED=2.0). The difference in walking speed between concrete and rubber correlated with the difference in the mean acceleration and the difference in the variance of acceleration of the legs and back (r ≥0.6). Three-dimensional accelerometers seem to be a promising tool for lameness detection on farm and to study walking surfaces, especially when attached to a leg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large-area PVDF thin films have been prepared and characterized for quasi-static and high frequency dynamic strain sensing applications. These films are prepared using hot press method and the piezoelectric phase (beta-phase) has been achieved by thermo-mechanical treatment and poling under DC field. The fabricated films have been characterized for quasi-static strain sensing and the linear strain-voltage relationship obtained is promising. In order to evaluate the ultrasonic sensing properties, a PZT wafer has been used to launch Lamb waves in a metal beam on which the PVDF film sensor is bonded at a distance. The voltage signals obtained from the PVDF films have been compared with another PZT wafer sensor placed on the opposite surface of the beam as a reference signal. Due to higher stiffness and higher thickness of the PZT wafer sensors, certain resonance patterns significantly degrade the sensor sensitivity curves. Whereas, the present results show that the large-area PVDF sensors can be superior with the signal amplitude comparable to that of PZT sensors and with no resonance-induced effect, which is due to low mechanical impedance, smaller thickness and larger area of the PVDF film. Moreover, the developed PVDF sensors are able to capture both A(0) and S-0 modes of Lamb wave, whereas the PZT sensors captures only A(0) mode in the same scale of voltage output. This shows promises in using large-area PVDF films with various surface patterns on structures for distributed sensing and structural health monitoring under quasi-static, vibration and ultrasonic situations. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of holographic interferometry to the measurement of the corrosion rate of aluminium in sodium hydroxide is investigated. Details of the fabrication of the corrosion cell and the experimental procedure are given. Thickness loss of aluminium was found for different dissolution times and compared with the conventional weight-loss method using a microbalance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A technique for the measurement of frequency within a cycle of a periodic input is described. This can be useful for quicker measurement of low frequencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method is described to combine a modern function generator and a digital oscilloscope to configure a setup that can directly measure the amplitude frequency response of a system. This is achieved by synchronously triggering both instruments, with the function generator operated in the ``Linear-Sweep'' frequency mode, while the oscilloscope is operated in the ``Envelope'' acquisition mode. Under these conditions, the acquired envelopes directly correspond to the (input and output signal) spectra, whose ratio yields the amplitude frequency response. The method is easy to configure, automatic, time-efficient, and does not require any external control or interface or programming. This method is ideally suited to impart hands-on experience in sweep frequency response measurements, demonstrate resonance phenomenon in transformer windings, explain the working principle of an impedance analyzer, practically exhibit properties of network functions, and so on. The proposed method is an inexpensive alternative to existing commercial equipment meant for this job and is also an effective teaching aid. Details of its implementation, along with some practical measurements on an actual transformer, are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlén equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilises direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially non-homogenous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The proportion of patients over 75 years of age, receiving all different types of healthcare, is constantly increasing. The elderly undergo surgery and anaesthetic procedures more often than middle-aged patients. Poor pain management in the elderly is still an issue. Although the elderly consumes the greatest proportion of prescribed medicines in Western Europe, most clinical pharmacological studies have been performed in healthy volunteers or middle-aged patients. The aim of this study was to investigate pain measurement and management in cognitively impaired patients in long term hospital care and in cognitively normal elderly patients after cardiac surgery. This thesis incorporated 366 patients, including 86 home-dwelling or hospitalized elderly with chronic pain and 280 patients undergoing cardiac surgery with acute pain. The mean age of patients was 77 (SD ± 8) years and approximately 8400 pain measurements were performed with four pain scales: Verbal Rating Scale (VRS), the Visual Analogue Scale (VAS), the Red Wedge Scale (RWS), and the Facial Pain Scale (FPS). Cognitive function, depression, functional ability in daily life, postoperative sedation and postoperative confusion were assessed with MMSE, GDS, Barthel Index, RASS, and CAM-ICU, respectively. The effects and plasma concentrations of fentanyl and oxycodone were measured in elderly (≥ 75 years) and middle-aged patients (≤ 60 years) and the opioid-sparing effect of pregabalin was studied after cardiac surgery. The VRS pain scores after movement correlated with the Barthel Index. The VRS was most successful in the groups of demented patients (MMSE 17-23, 11-16 and ≤ 10) and in elderly patients on the first day after cardiac surgery. The elderly had a higher plasma concentration of fentanyl at the end of surgery than younger patients. The plasma concentrations of oxycodone were comparable between the groups. Pain intensity on the VRS was lower and the sedation scores were higher in the elderly. Total oxycodone consumption during five postoperative days was reduced by 48% and the CAM-ICU scores were higher on the first postoperative day in the pregabalin group. The incidence of postoperative pain during movement was lower in the pregabalin group three months after surgery. This investigation demonstrates that chronic pain did not seem to impair daily activities in home-dwelling Finnish elderly. The VRS appeared to be applicable for elderly patients with clear cognitive dysfunction (MMSE ≤17) and it was the most feasible pain scale for the early postoperative period after cardiac surgery. After cardiac surgery, plasma concentrations of fentanyl in elderly were elevated, although oxycodone concentrations were at similar level compared to middle-aged patients. The elderly had less pain and were more sedated after doses of oxycodone. Therefore, particular attention must be given to individual dosing of the opioids in elderly surgical patients, who often need a smaller amount for adequate analgesia than middle-aged patients. The administration of pregabalin reduced postoperative oxycodone consumption after cardiac surgery. Pregabalin-treated patients had less confusion, and additionally to less postoperative pain on the first postoperative day and during movement at three months post-surgery. Pregabalin might be a new alternative as analgesic for acute postoperative and chronic pain management in the elderly. Its clinical role and safety remains to be verified in large-scale randomized and controlled studies. In the future, many clinical trials in the older category of patients will be needed to facilitate improvements in health care methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this note we demonstrate the use of top polarization in the study of t (t) over bar resonances at the LHC, in the possible case where the dynamics implies a non-zero top polarization. As a probe of top polarization we construct an asymmetry in the decay-lepton azimuthal angle distribution (corresponding to the sign of cos phi(l)) in the laboratory. The asymmetry is non-vanishing even for a symmetric collider like the LHC, where a positive z axis is not uniquely defined. The angular distribution of the leptons has the advantage of being a faithful top-spin analyzer, unaffected by possible anomalous tbW couplings, to linear order. We study, for purposes of demonstration, the case of a Z' as might exist in the little Higgs models. We identify kinematic cuts which ensure that our asymmetry reflects the polarization in sign and magnitude. We investigate possibilities at the LHC with two energy options: root s = 14TeV and root s = 7TeV, as well as at the Tevatron. At the LHC the model predicts net top quark polarization of the order of a few per cent for M-Z' similar or equal to 1200GeV, being as high as 10% for a smaller mass of the Z' of 700GeV and for the largest allowed coupling in the model, the values being higher for the 7TeV option. These polarizations translate to a deviation from the standard-model value of azimuthal asymmetry of up to about 4% (7%) for 14 (7) TeV LHC, whereas for the Tevatron, values as high as 12% are attained. For the 14TeV LHC with an integrated luminosity of 10 fb(-1), these numbers translate into a 3 sigma sensitivity over a large part of the range 500 less than or similar to M-Z' less than or similar to 1500GeV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the work related to characterisation of an ultrasonic transducer fabricated in the laboratory. The response of the medium to the ultrasonic wave was obtained by converting the time domain signal to frequency domain, using the FFT algorithm. Cross-correlation technique was adopted to increase the S/N ratio in the raw time domain signal and subsequently, to determine the ultrasonic velocity in the medium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AlxGa1-xN alloys with x=0.375, 0.398, 0.401, 0.592 and 0.696 were deposited on sapphire substrate by the hydride-vapor-phase epitaxy (HVPE) method. Thermal effusivity measurements were carried out on AlxGa1-xN alloys using a thermal microscope at room temperature. The lag between sinusoidal heating laser wave and thermoreflectance wave was used to measure the thermal diffusivity. Thermal conductivity values of the AlxGa1-xN alloys were also obtained as a function of AIN mole fraction in the alloy. The thermal conductivity was found to decrease with increasing AIN fraction and the experimental data agree with values estimated using the virtual crystal model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For studying systems containing nitrogen, limited use of N-14 NMR spectroscopy has been made because of the large quadrupolar interaction experienced by the N-14 nucleus and the absence of a central transition. To overcome the above problem, use of overtone spectroscopy has been suggested. Though this approach has limited applicability for powder samples due to second order quadrupole broadening, it is useful for studying oriented samples and single crystals. Here, we demonstrate the use of the recently proposed dipolar assisted polarization transfer (DAPT) pulse scheme for exciting the overtone transitions. The pulse sequence may also be utilized as a two-dimensional experiment to obtain H-1-N-14 dipolar couplings and H-1 chemical shifts. (C) 2010 Elsevier B.V. All rights reserved.