868 resultados para Statistic validation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two high performance liquid chromatography (HPLC) methods for the quantitative determination of indinavir sulfate were tested, validated and statistically compared. Assays were carried out using as mobile phases mixtures of dibutylammonium phosphate buffer pH 6.5 and acetonitrile (55:45) at 1 mL/min or citrate buffer pH 5 and acetonitrile (60:40) at 1 mL/min, an octylsilane column (RP-8) and a UV spectrophotometric detector at 260 nm. Both methods showed good sensitivity, linearity, precision and accuracy. The statistical analysis using the t-student test for the determination of indinavir sulfate raw material and capsules indicated no statistically significant difference between the two methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and rapid precipitation titration method was developed and validated to determine sulfate ion content in indinavir sulfate raw material. 0.1 mol L-1 lead nitrate volumetric solution was used as titrant employing potentiometric endpoint determination using a lead-specific electrode. The United States Pharmacopoeia Forum indicates a potentiometric method for sulfate ion quantitation using 0.1 mol L-1 lead perchlorate as titrant. Both methods were validated concerning linearity, precision and accuracy, yielding good results. The sulfate ion content found by the two validated methods was compared by the statistical t-student test, indicating that there was no statistically significant difference between the methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Computerised databases of primary care clinical records are widely used for epidemiological research. In Catalonia, the InformationSystem for the Development of Research in Primary Care (SIDIAP) aims to promote the development of research based on high-quality validated data from primary care electronic medical records. Objective The purpose of this study is to create and validate a scoring system (Registry Quality Score, RQS) that will enable all primary care practices (PCPs) to be selected as providers of researchusable data based on the completeness of their registers. Methods Diseases that were likely to be representative of common diagnoses seen in primary care were selected for RQS calculations. The observed/ expected cases ratio was calculated for each disease. Once we had obtained an estimated value for this ratio for each of the selected conditions we added up the ratios calculated for each condition to obtain a final RQS. Rate comparisons between observed and published prevalences of diseases not included in the RQS calculations (atrial fibrillation, diabetes, obesity, schizophrenia, stroke, urinary incontinenceand Crohn’s disease) were used to set the RQS cutoff which will enable researchers to select PCPs with research-usable data. Results Apart from Crohn’s disease, all prevalences were the same as those published from the RQS fourth quintile (60th percentile) onwards. This RQS cut-off provided a total population of 1 936 443 (39.6% of the total SIDIAP population). Conclusions SIDIAP is highly representative of the population of Catalonia in terms of geographical, age and sex distributions. We report the usefulness of rate comparison as a valid method to establish research-usable data within primary care electronic medical records

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Validation and verification operations encounter various challenges in product development process. Requirements for increasing the development cycle pace set new requests for component development process. Verification and validation usually represent the largest activities, up to 40 50 % of R&D resources utilized. This research studies validation and verification as part of case company's component development process. The target is to define framework that can be used in improvement of the validation and verification capability evaluation and development in display module development projects. Validation and verification definition and background is studied in this research. Additionally, theories such as project management, system, organisational learning and causality is studied. Framework and key findings of this research are presented. Feedback system according of the framework is defined and implemented to the case company. This research is divided to the theory and empirical parts. Theory part is conducted in literature review. Empirical part is done in case study. Constructive methode and design research methode are used in this research A framework for capability evaluation and development was defined and developed as result of this research. Key findings of this study were that double loop learning approach with validation and verification V+ model enables defining a feedback reporting solution. Additional results, some minor changes in validation and verification process were proposed. There are a few concerns expressed on the results on validity and reliability of this study. The most important one was the selected research method and the selected model itself. The final state can be normative, the researcher may set study results before the actual study and in the initial state, the researcher may describe expectations for the study. Finally reliability of this study, and validity of this work are studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to examine the clinical validation of a Virtual Reality Environment (VRE) designed to normalize eating patterns in Eating Disorders (ED). The efficacy of VR in eliciting emotions, sense of presence and reality of the VRE were explored in 22 ED patients and 37 healthy eating individuals. The VRE (non-immersive) consisted of a kitchen room where participants had to eat a virtual pizza. In order to assess the sense of presence and reality produced by the VRE, participants answered seven questions with a Likert scale (0-10) during the experience, and then filled out the Reality Judgment and Presence Questionnaire (RJPQ) and ITC-Sense of Presence Inventory (ITC-SOPI). The results showed that the VRE induced a sense of presence and was felt as real for both groups, without differences in the experience of 'ease' with the VRE, sense of physical space, or the ecological validity assigned to the virtual kitchen and eating virtually. However, the ED patients reported paying more attention and experiencing greater emotional involvement and dysphoria after virtual eating. The results suggest that the VRE was clinically meaningful to the ED patients and might be a relevant therapy tool for normalizing their eating patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: There is a need for short, specific instruments that assess quality of life (QOL) adequately in the older adult population. The aims of the present study were to obtain evidence on the validity of the inferences that could be drawn from an instrument to measure QOL in the aging population (people 50+ years old), and to test its psychometric properties. METHODS: The instrument, WHOQOL-AGE, comprised 13 positive items, assessed on a five-point rating scale, and was administered to nationally representative samples (n = 9987) from Finland, Poland, and Spain. Cronbach's alpha was employed to assess internal consistency reliability, whereas the validity of the questionnaire was assessed by means of factor analysis, graded response model, Pearson's correlation coefficient and unpaired t-test. Normative values were calculated across countries and for different age groups. RESULTS: The satisfactory goodness-of-fit indices confirmed that the factorial structure of WHOQOL-AGE comprises two first-order factors. Cronbach's alpha was 0.88 for factor 1, and 0.84 for factor 2. Evidence supporting a global score was found with a second-order factor model, according to the goodness-of-fit indices: CFI = 0.93, TLI = 0.91, RMSEA = 0.073. Convergent validity was estimated at r = 0.75 and adequate discriminant validity was also found. Significant differences were found between healthy individuals (74.19 ± 13.21) and individuals with at least one chronic condition (64.29 ± 16.29), supporting adequate known-groups validity. CONCLUSIONS: WHOQOL-AGE has shown good psychometric properties in Finland, Poland, and Spain. Therefore, considerable support is provided to using the WHOQOL-AGE to measure QOL in older adults in these countries, and to compare the QOL of older and younger adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a validation of an analytical procedure for the analysis of petroleum hydrocarbons in marine sediment samples. The proposed protocol is able to measure n-alkanes and polycyclic aromatic hydrocarbons (PAH) in samples at concentrations as low as 30 ng/g, with a precision better than 15% for most of analytes. The extraction efficiency of fortified sediments varied from 65.1 to 105.6% and 59.7 to 97.8%, for n-alkanes and PAH in the ranges: C16 - C32 and fluoranthene - benzo(a)pyrene, respectively. The analytical protocol was applied to determine petroleum hydrocarbons in sediments collected from a marine coastal zone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports the validation of an analytical UV spectrophotometric method to assay dexamethasone in tablets (assay and dissolution studies). The method was linear in the range between 1 and 30 µg mL-1 presenting a good correlation coefficient (r = 0.9998, n = 7). Precision and accuracy analysis showed low relative standard deviation (< 2.00%) and good percentual recoveries (95-105%). The procedure was linear, accurate, precise, and robust. The method is simple, and it has low cost. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay dexamethasone in tablets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissolution test for telithromycin tablets was validated and developed. In order to choose the most discriminatory one, the conditions to carry out are 900 mL of sodium phosphate buffer at pH 7.5, paddles at 50 rpm stirring speed, time test set to 60 min and using USP apparatus 2 with paddles. The UV spectrophotometric method for determination of telithromycin released was developed and validated. The method presents linearity (r = 1) in the concentration range of 20-60 µg/mL. Precision and recoveries were good, 100.62 and 97.06%, respectively. The method was successfully used for the dissolution test of telithromycin tablets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method is described for the determination of the herbicide bispyribac-sodium in surface water, especially from river and irrigated rice water samples. The method involves extraction in solid phase and quantification by high performance liquid chromatography with diode array detection (HPLC-DAD). After optimization of the extraction and separation parameters, the method was validated. The method presented average recoveries of 101.3 and 97.7%, under repeatability and intermediate precision conditions, respectively, with adequate precision (RSD from 0.9 to 7.5%). The method was applied for the determination of bispyribac-sodium in surface water samples with a limit of detection of 0.1 μg L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study validated a high performance liquid chromatography (HPLC) method for the quantitative evaluation of quercetin in topical emulsions. The method was linear within 0.05 - 200 μg/mL range with a correlation coefficient of 0.9997, and without interference in the quercetin peak. The detection and quantitation limits were 18 and 29 ng/mL, respectively. The intra- and inter-assay precisions presented R.S.D. values lower than 2%. An average of 93% and 94% of quercetin was recovered for non-ionic and anionic emulsions, respectively. The raw material and anionic emulsion, but not non-ionic emulsion, were stable in all storage conditions for one year. The method reported is a fast and reliable HPLC technique useful for quercetin determination in topical emulsions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gas chromatographic method has been developed for the assay of fluvastatin sodium (FLU). FLU was silylated with N,O-bis(trimethylsilyl)trifluoroacetamide-1% trimethylchlorosilane at 90 ºC for 30 min and analysed in a DB-1 column by capillary gas chromatograph with a flame ionization detector. The method was validated. The assay was linear over the concentration range at 10.0 to 50.0 µg mL-1. The limit of detection and the limit of quantitation were 1.0 and 3.0 µg mL-1, respectively. The recoveries of FLU derivatives were in the range of 99.25-99.80%. In inter-day and intra-day analysis, the values of relative standard deviation (%) and the relative mean error (%) were found between 0.20-0.80% and -0.20-0.75%, respectively. The developed method was succesfully applied to analyze the FLU content in tablet formulation. The results were statistically compared with those obtained by the official method, and no significant difference was found between the two methods. Therefore, it can be recommended for the quality control assay of FLU in pharmaceutical industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reversed-phase liquid chromatographic (LC) and ultraviolet (UV) spectrophotometric methods were developed and validated for the assay of bromopride in oral and injectable solutions. The methods were validated according to ICH guideline. Both methods were linear in the range between 5-25 μg mL-1 (y = 41837x - 5103.4, r = 0.9996 and y = 0.0284x - 0.0351, r = 1, respectively). The statistical analysis showed no significant difference between the results obtained by the two methods. The proposed methods were found to be simple, rapid, precise, accurate, and sensitive. The LC and UV methods can be used in the routine quantitative analysis of bromopride in oral and injectable solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this research was to develop and validate an alternative analytical method for quantitative determination of levofloxacin in tablets and injection preparations. The calibration curves were linear over a concentration range from 3.0 to 8.0 μg mL-1. The relative standard deviation was below 1.0% for both formulations and average recovery was 101.42 ± 0.45% and 100.34 ± 0.85% for tablets and injection formulations, respectively. The limit of detection and limit of quantitation were 0.08 and 0.25 μg mL-1, respectively. It was concluded that the developed method is suitable for the quality control of levofloxacin in pharmaceuticals formulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive RP-HPLC method with UV detection successfully measured phenol(s) in an ointment containing 3% Stryphnodendron adstringens extract. Chromatography used acetonitrile (0.05% trifluoroacetic acid):water (0.05% trifluoroacetic acid) (v/v), flow rate 0.8 mL min-1. Quantitation was accomplished by the external-standard method. Linearity for 2.00 to 16.00 μg mL-1 (gallic acid) and 1.14 to 18.24 μg mL-1 (gallocatechin) was established. Intra- and inter-day precision levels were under 5%. LOD and LOQ were 0.231 and 0.770 μg mL-1 (gallic acid) and 0.151 and 0.504 μg mL-1 (gallocatechin), respectively. Determination of phenols was unaffected by product excipients.