814 resultados para Optical detection systems


Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this short paper, we present an integrated approach to detecting and mitigating cyber-attacks to modern interconnected industrial control systems. One of the primary goals of this approach is that it is cost effective, and thus whenever possible it builds on open-source security technologies and open standards, which are complemented with novel security solutions that address the specific challenges of securing critical infrastructures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background

Diabetic macular oedema (DMO) is a thickening of the central retina, or the macula, and is associated with long-term visual loss in people with diabetic retinopathy (DR). Clinically significant macular oedema (CSMO) is the most severe form of DMO. Almost 30 years ago, the Early Treatment Diabetic Retinopathy Study (ETDRS) found that CSMO, diagnosed by means of stereoscopic fundus photography, leads to moderate visual loss in one of four people within three years. It also showed that grid or focal laser photocoagulation to the macula halves this risk. Recently, intravitreal injection of antiangiogenic drugs has also been used to try to improve vision in people with macular oedema due to DR.Optical coherence tomography (OCT) is based on optical reflectivity and is able to image retinal thickness and structure producing cross-sectional and three-dimensional images of the central retina. It is widely used because it provides objective and quantitative assessment of macular oedema, unlike the subjectivity of fundus biomicroscopic assessment which is routinely used by ophthalmologists instead of photography. Optical coherence tomography is also used for quantitative follow-up of the effects of treatment of CSMO.

Objectives

To determine the diagnostic accuracy of OCT for detecting DMO and CSMO, defined according to ETDRS in 1985, in patients referred to ophthalmologists after DR is detected. In the update of this review we also aimed to assess whether OCT might be considered the new reference standard for detecting DMO.

Search methods

We searched the Cochrane Database of Systematic Reviews (CDSR), the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA) and the NHS Economic Evaluation Database (NHSEED) (The Cochrane Library 2013, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to June 2013), EMBASE (January 1950 to June 2013), Web of Science Conference Proceedings Citation Index - Science (CPCI-S) (January 1990 to June 2013), BIOSIS Previews (January 1969 to June 2013), MEDION and the Aggressive Research Intelligence Facility database (ARIF). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 25 June 2013. We checked bibliographies of relevant studies for additional references.

Selection Criteria

We selected studies that assessed the diagnostic accuracy of any OCT model for detecting DMO or CSMO in patients with DR who were referred to eye clinics. Diabetic macular oedema and CSMO were diagnosed by means of fundus biomicroscopy by ophthalmologists or stereophotography by ophthalmologists or other trained personnel.

Data collection and analysis

Three authors independently extracted data on study characteristics and measures of accuracy. We assessed data using random-effects hierarchical sROC meta-analysis models.

Main results

We included 10 studies (830 participants, 1387 eyes), published between 1998 and 2012. Prevalence of CSMO was 19% to 65% (median 50%) in nine studies with CSMO as the target condition. Study quality was often unclear or at high risk of bias for QUADAS 2 items, specifically regarding study population selection and the exclusion of participants with poor quality images. Applicablity was unclear in all studies since professionals referring patients and results of prior testing were not reported. There was a specific 'unit of analysis' issue because both eyes of the majority of participants were included in the analyses as if they were independent.In nine studies providing data on CSMO (759 participants, 1303 eyes), pooled sensitivity was 0.78 (95% confidence interval (CI) 0.72 to 0.83) and specificity was 0.86 (95% CI 0.76 to 0.93). The median central retinal thickness cut-off we selected for data extraction was 250 µm (range 230 µm to 300 µm). Central CSMO was the target condition in all but two studies and thus our results cannot be applied to non-central CSMO.Data from three studies reporting accuracy for detection of DMO (180 participants, 343 eyes) were not pooled. Sensitivities and specificities were about 0.80 in two studies and were both 1.00 in the third study.Since this review was conceived, the role of OCT has changed and has become a key ingredient of decision-making at all levels of ophthalmic care in this field. Moreover, disagreements between OCT and fundus examination are informative, especially false positives which are referred to as subclinical DMO and are at higher risk of developing clinical CSMO.

Authors' conclusions

Using retinal thickness thresholds lower than 300 µm and ophthalmologist's fundus assessment as reference standard, central retinal thickness measured with OCT was not sufficiently accurate to diagnose the central type of CSMO in patients with DR referred to retina clinics. However, at least OCT false positives are generally cases of subclinical DMO that cannot be detected clinically but still suffer from increased risk of disease progression. Therefore, the increasing availability of OCT devices, together with their precision and the ability to inform on retinal layer structure, now make OCT widely recognised as the new reference standard for assessment of DMO, even in some screening settings. Thus, this review will not be updated further.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present the GALEX detection of a UV burst at the time of explosion of an optically normal supernova (SN) IIP (PS1-13arp) from the Pan-STARRS1 survey at z = 0.1665. The temperature and luminosity of the UV burst match the theoretical predictions for shock breakout in a red supergiant (RSG), but with a duration a factor of similar to 50 longer than expected. We compare the NUV light curve of PS1-13arp to previous GALEX detections of SNe IIP and find clear distinctions that indicate that the UV emission is powered by shock breakout, and not by the subsequent cooling envelope emission previously detected in these systems. We interpret the similar to 1 day duration of the UV signal with a shock breakout in the wind of an RSG with a pre-explosion mass-loss rate of similar to 10(-3) M-circle dot yr(-1). This mass-loss rate is enough to prolong the duration of the shock breakout signal, but not enough to produce an excess in the optical plateau light curve or narrow emission lines powered by circumstellar interaction. This detection of nonstandard, potentially episodic high mass loss in an RSG SN progenitor has favorable consequences for the prospects of future wide-field UV surveys to detect shock breakout directly in these systems, and provide a sensitive probe of the pre-explosion conditions of SN progenitors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Systematic principal component analysis (PCA) methods are presented in this paper for reliable islanding detection for power systems with significant penetration of distributed generations (DGs), where synchrophasors recorded by Phasor Measurement Units (PMUs) are used for system monitoring. Existing islanding detection methods such as Rate-of-change-of frequency (ROCOF) and Vector Shift are fast for processing local information, however with the growth in installed capacity of DGs, they suffer from several drawbacks. Incumbent genset islanding detection cannot distinguish a system wide disturbance from an islanding event, leading to mal-operation. The problem is even more significant when the grid does not have sufficient inertia to limit frequency divergences in the system fault/stress due to the high penetration of DGs. To tackle such problems, this paper introduces PCA methods for islanding detection. Simple control chart is established for intuitive visualization of the transients. A Recursive PCA (RPCA) scheme is proposed as a reliable extension of the PCA method to reduce the false alarms for time-varying process. To further reduce the computational burden, the approximate linear dependence condition (ALDC) errors are calculated to update the associated PCA model. The proposed PCA and RPCA methods are verified by detecting abnormal transients occurring in the UK utility network.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Molecular logic-based computation continues to throw up new applications in sensing and switching, the newest of which is the edge detection of objects. The scope of this phenomenon is mapped out by the use of structure-activity relationships, where several structures of the molecules and of the objects are examined. The different angles and curvatures of the objects are followed with good-fidelity in the visualized edges, even when the objects are in reverse video.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Bridge weigh-in-motion (B-WIM), a system that uses strain sensors to calculate the weights of trucks passing on bridges overhead, requires accurate axle location and speed information for effective performance. The success of a B-WIM system is dependent upon the accuracy of the axle detection method. It is widely recognised that any form of axle detector on the road surface is not ideal for B-WIM applications as it can cause disruption to the traffic (Ojio & Yamada 2002; Zhao et al. 2005; Chatterjee et al. 2006). Sensors under the bridge, that is Nothing-on-Road (NOR) B-WIM, can perform axle detection via data acquisition systems which can detect a peak in strain as the axle passes. The method is often successful, although not all bridges are suitable for NOR B-WIM due to limitations of the system. Significant research has been carried out to further develop the method and the NOR algorithms, but beam-and-slab bridges with deep beams still present a challenge. With these bridges, the slabs are used for axle detection, but peaks in the slab strains are sensitive to the transverse position of wheels on the beam. This next generation B-WIM research project extends the current B-WIM algorithm to the problem of axle detection and safety, thus overcoming the existing limitations in current state-of–the-art technology. Finite Element Analysis was used to determine the critical locations for axle detecting sensors and the findings were then tested in the field. In this paper, alternative strategies for axle detection were determined using Finite Element analysis and the findings were then tested in the field. The site selected for testing was in Loughbrickland, Northern Ireland, along the A1 corridor connecting the two cities of Belfast and Dublin. The structure is on a central route through the island of Ireland and has a high traffic volume which made it an optimum location for the study. Another huge benefit of the chosen location was its close proximity to a nearby self-operated weigh station. To determine the accuracy of the proposed B-WIM system and develop a knowledge base of the traffic load on the structure, a pavement WIM system was also installed on the northbound lane on the approach to the structure. The bridge structure selected for this B-WIM research comprised of 27 pre-cast prestressed concrete Y4-beams, and a cast in-situ concrete deck. The structure, a newly constructed integral bridge, spans 19 m and has an angle of skew of 22.7°.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The increasing scale of Multiple-Input Multiple- Output (MIMO) topologies employed in forthcoming wireless communications standards presents a substantial implementation challenge to designers of embedded baseband signal processing architectures for MIMO transceivers. Specifically the increased scale of such systems has a substantial impact on the perfor- mance/cost balance of detection algorithms for these systems. Whilst in small-scale systems Sphere Decoding (SD) algorithms offer the best quasi-ML performance/cost balance, in larger systems heuristic detectors, such Tabu-Search (TS) detectors are superior. This paper addresses a dearth of research in architectures for TS-based MIMO detection, presenting the first known realisations of TS detectors for 4 × 4 and 10 × 10 MIMO systems. To the best of the authors’ knowledge, these are the largest single-chip detectors on record.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Esta tese descreve diversas estratégias preparativas assim como estudos de caracterização de nanocompósitos e outras nanoestruturas, para a análise em espectroscopia de Raman com intensificação por superfície (SERS). Em particular foi estudada a incorporação de nanopartículas (NPs) metálicas de Ag e Au em matrizes poliméricas visando avaliar o potencial destes materiais como novos substratos para SERS na deteção de moléculas. O primeiro capítulo consiste numa revisão bibliográfica, onde é destacado o desenvolvimento de novos substratos para SERS utilizando nomeadamente nanopartículas de Ag, Au e Cu. Numa primeira fase, esta secção apresenta uma breve descrição sobre as propriedades plasmónicas dos metais utilizados e alguns conceitos básicos de espectroscopia de difusão de Raman. Posteriormente, descreve-se em mais detalhe o efeito de SERS, revendo-se sobretudo a química de materiais descrita em trabalhos recentes tendo em conta a sua utilização como novas plataformas para análise química por SERS. O capítulo 2 descreve a síntese e caracterização de nanocompósitos de poli(acrilato de butilo) obtidos através de polimerização in situ por miniemulsão na presença de nanopartículas de Ag. Os nanocompósitos Ag/PtBA foram investigados como novos substratos de SERS visando o desenvolvimento de novas plataformas versáteis para deteção molecular. Estudos como o efeito da temperatura, pH e pressão foram investigados, visando a compreensão do efeito da matriz polimérica na difusão/adsorção do analito (ácido tiossalicílico) na superfície metálica. No capítulo 3, os nanocompósitos de Ag/PtBA descritos anteriormente foram investigados detalhadamente como substratos para bio-deteção em SERS, usando a adenina como analito modelo. Os nanocompósitos foram submetidos a vários tratamentos pré-analíticos para a bio-deteção da adenina. Foram realizadas experiências nos sistemas Ag/PtBA de modo a obter informação sobre o efeito do pH na deteção deste analito em soluções aquosas diluídas. Os nanocompósitos poliméricos obtidos apresentam a vantagem de poderem ser processados utilizando tecnologia disponível. Pelo que o estudo das suas propriedades térmicas é especialmente relevante. Assim, a influência da incorporação de NPs inorgânicas na temperatura de transição vítrea (Tg) do polímero PtBA foi investigada por meio de calorimetria diferencial de varrimento (DSC) e os resultados são apresentados no capítulo 4. Estes estudos descrevem efeitos na Tg do PtBA quando analisado em nanocompósitos obtidos por diferentes métodos (métodos ex situ e in situ), contendo nanopartículas metálicas com diferentes distribuições de tamanho e presentes em quantidade variável na matriz polimérica. Estes estudos possibilitaram relacionar a influência das NPs metálicas na mobilidade das cadeias poliméricas com as propriedades térmicas observadas. O capítulo 5 descreve a preparação e caracterização de materiais compósitos de base polimérica (PtBA) e NPs de Au com morfologia de bastonetes (NRs). Estes materiais foram investigados como substratos para SERS tendo originado um bom sinal de SERS na análise de 2-2’-ditiodipiridina. Investigouse igualmente o efeito da variação da morfologia das NPs metálicas (esferas e bastonetes), a razão de aspecto (R.A.) dos bastonetes e o tipo de matriz polimérica (PtBA e PnBA) no sinal de SERS. No capítulo 6 é descrita a utilização da técnica de SERS como método alternativo para a monitorização de alterações morfológicas de coloides de NRs de Au. Os NRs de Au foram recolhidos em diferentes fases de oxidação promovida pela presença de K2S2O8 e a sua sensibilidade como substratos de SERS foi avaliada utilizando o anião dietilditiocarbamato (DTC) como analito modelo. Os estudos foram realizados utilizando as linhas de excitação a 1064 nm e 633 nm. Este estudo demonstrou que a sensibilidade dos NRs de Au como substratos de SERS diminui à medida que a sua R.A. diminui devido à competitividade do CTAB (estabilizante) e o DTC pela superfície dos NRs. É de salientar que este processo é acompanhado por um diferente comportamento em termos de adsorção dos dois tautómeros do DTC à superfície do metal. O capítulo 7 introduz um novo tipo de compósitos para SERS, utilizando matrizes biopoliméricas. Assim, descreve-se a preparação e caracterização de nanocompósitos de carragenano e NPs de Ag. Nesta secção é avaliada a utilização destes materiais como novos substratos para a análise em SERS, utilizando a 2-2’-ditiodipiridina como molécula modelo. Descrevem-se estudos pioneiros que procuram relacionar a dependência do sinal de SERS com a força do gel. Para tal, realizou-se um estudo sistemático aos nanobiocompósitos usados como substratos de SERS em diferentes condições analíticas e investigaram-se as suas propriedades reológicas. No capitulo 8 é descrita a investigação de nanocompósitos de Ag/Gelatina como substratos para SERS, utilizando o anião dietilditiocarbamato como analito modelo. Realizaram-se várias experiências para correlacionar a variação da força do gel com o aumento do sinal de SERS bem como a diferente adsorção dos dois tautómeros do DTC à superfície do metal. Ao longo desta dissertação são apresentados metodologias distintas para a preparação e obtenção de nanocompósitos com base em polímeros (sintéticos ou naturais) e NPs metálicas (Ag e Au). Esta investigação não só permitiu a síntese e estudo de novos substratos para SERS mas também a compreensão do efeito matriz/NPs metálicas no sinal de SERS e na formação de “hot spots”. Este trabalho contribui para o enriquecimento na área da Nanociência e Nanotecnologia demonstrando a eficácia e reprodutibilidade de nanocompósitos com base em polímeros como novos substratos para SERS. Embora as propriedades óticas apresentadas por estes materiais serem aqui direcionadas para a deteção molecular pela técnica de SERS, estes materiais podem ser investigados em outras área tecnológicas.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

As comunicações quânticas aplicam as leis fundamentais da física quântica para codificar, transmitir, guardar e processar informação. A mais importante e bem-sucedida aplicação é a distribuição de chaves quânticas (QKD). Os sistemas de QKD são suportados por tecnologias capazes de processar fotões únicos. Nesta tese analisamos a geração, transmissão e deteção de fotões únicos e entrelaçados em fibras óticas. É proposta uma fonte de fotões única baseada no processo clássico de mistura de quatro ondas (FWM) em fibras óticas num regime de baixas potências. Implementamos essa fonte no laboratório, e desenvolvemos um modelo teórico capaz de descrever corretamente o processo de geração de fotões únicos. O modelo teórico considera o papel das nãolinearidades da fibra e os efeitos da polarização na geração de fotões através do processo de FWM. Analisamos a estatística da fonte de fotões baseada no processo clássico de FWM em fibras óticas. Derivamos um modelo teórico capaz de descrever a estatística dessa fonte de fotões. Mostramos que a estatística da fonte de fotões evolui de térmica num regime de baixas potências óticas, para Poissoniana num regime de potências óticas moderadas. Validamos experimentalmente o modelo teórico, através do uso de fotodetetores de avalanche, do método estimativo da máxima verossimilhança e do algoritmo de maximização de expectativa. Estudamos o processo espontâneo de FWM como uma fonte condicional de fotões únicos. Analisamos a estatística dessa fonte em termos da função condicional de coerência de segunda ordem, considerando o espalhamento de Raman na geração de pares de fotões, e a perda durante a propagação de fotões numa fibra ótica padrão. Identificamos regimes apropriados onde a fonte é quase ideal. Fontes de pares de fotões implementadas em fibras óticas fornecem uma solução prática ao problema de acoplamento que surge quando os pares de fotões são gerados fora da fibra. Exploramos a geração de pares de fotões através do processo espontâneo de FWM no interior de guias de onda com suceptibilidade elétrica de terceira ordem. Descrevemos a geração de pares de fotões em meios com elevado coeficiente de absorção, e identificamos regimes ótimos para o rácio contagens coincidentes/acidentais (CAR) e para a desigualdade de Clauser, Horne, Shimony, and Holt (CHSH), para o qual o compromisso entre perda do guia de onda e não-linearidades maximiza esses parâmetros.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper we present iterative frequency-domain multiuser detection (MUD) receivers for the uplink transmission of direct sequence code division multiple access systems (DS-CDMA) that combine iterative block decision feedback equalization (IB-DFE) principles with interference cancelation techniques. Both successive interference cancelation (SIC) and parallel interference cancelation (PIC) structures are considered. Our performance results show that the proposed receiver structures have excellent bit error rate (BER) performances, that can be close to the single-user matched filter bound (MFB), even for fully loaded systems and severely time-dispersive channels1.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A DS-CDMA (Direct Sequence-Coded Division Multiple Access) system has maximum spectral efficiency if the system is fully loaded (i.e., the number of users is equal to the spreading factor) and we employ signals with bandwidth equal to the chip rate. However, due to implementation constraints we need to employ signals with higher bandwidth, decreasing the system’s spectral efficiency. In this paper we consider prefixassisted DS-CDMA systems with bandwidth that can be significantly above the chip rate. To allow high spectral efficiency we consider highly overloaded systems where the number of users can be twice the spreading factor or even more. To cope with the strong interference levels we present an iterative frequencydomain receiver that takes full advantage of the total bandwidth of the transmitted signals. Our performance results show that the proposed receiver can have excellent performance, even for highly overloaded systems. Moreover, the overall system performance can be close to the maximum theoretical spectral efficiency, even with transmitted signals that have bandwidth significantly above the chip rate.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper we consider the uplink transmission within a DS-CDMA system employing CP-assisted (Cylic Prefix) block transmission techniques combined with spatial multiplexing techniques that require multiple antennas at both the transmitter and the receiver. We present an efficient frequency-domain receiver structure with iterative MUD (MultiUser Detection). The performance of the proposed receiver can be close to the single user matched filter bound, even for fully loaded systems and/or severely time-dispersive channels.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Freshness and safety of muscle foods are generally considered as the most important parameters for the food industry. To address the rapid detection of meat spoilage microorganisms during aerobic or modified atmosphere storage, an electronic nose with the aid of fuzzy wavelet network has been considered in this research. The proposed model incorporates a clustering pre-processing stage for the definition of fuzzy rules. The dual purpose of the proposed modelling approach is not only to classify beef samples in the respective quality class (i.e. fresh, semi-fresh and spoiled), but also to predict their associated microbiological population directly from volatile compounds fingerprints. Comparison results against neural networks and neurofuzzy systems indicated that the proposed modelling scheme could be considered as a valuable detection methodology in food microbiology