902 resultados para platform geometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The implementation of local geodetic networks for georeferencing of rural properties has become a requirement after publication of the Georeferencing Technical Standard by INCRA. According to this standard, the maximum distance of baselines to GNSS L1 receivers is of 20 km. Besides the length of the baseline, the geometry and the number of geodetic control stations are other factors to be considered in the implementation of geodetic networks. Thus, this research aimed to examine the influence of baseline lengths higher than the regulated limit of 20 km, the geometry and the number of control stations on quality of local geodetic networks for georeferencing, and also to demonstrate the importance of using specific tests to evaluate the solution of ambiguities and on the quality of the adjustment. The results indicated that the increasing number of control stations has improved the quality of the network, the geometry has not influenced on the quality and the baseline length has influenced on the quality; however, lengths higher than 20 km has not interrupted the implementation, with GPS L1 receiver, of the local geodetic network for the purpose of georeferencing. Also, the use of different statistical tests, both for the evaluation of the resolution of ambiguities and for the adjustment, have enabled greater clearness in analyzing the results, which allow that unsuitable observations may be eliminated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate stress distribution on the pen-implant bone, simulating the influence of Nobel Select implants with straight or angulated abutments on regular and switching platform in the anterior maxilla, by means of 3-dimensional finite element analysis. Four mathematical models of a central incisor supported by external hexagon implant (13 mm x 5 mm) were created varying the platform (R, regular or S. switching) and the abutments (S, straight or A, angulated 15 degrees). The models were created by using Mimics 13 and Solid Works 2010 software programs. The numerical analysis was performed using ANSYS Workbench 10.0. Oblique forces (100 N) were applied to the palatine surface of the central incisor. The bone/implant interface was considered perfectly integrated. Maximum (sigma(max)) and minimum (sigma(min)) principal stress values were obtained. For the cortical bone the highest stress values (sigma(max)) were observed in the RA (regular platform and angulated abutment, 51 MPa), followed by SA (platform switching and angulated abutment, 44.8 MPa), RS (regular platform and straight abutment, 38.6 MPa) and SS (platform switching and straight abutment, 36.5 MPa). For the trabecular bone, the highest stress values (sigma(max)) were observed in the RA (6.55 MPa), followed by RS (5.88 MPa), SA (5.60 MPa), and SS (4.82 MPa). The regular platform generated higher stress in the cervical periimplant region on the cortical and trabecular bone than the platform switching, irrespective of the abutment used (straight or angulated).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a study case in which a geosynthetic-reinforced soil (GRS) structure was used to rebuild a 12 m high slope after its failure. The failed slope is located between the parking lot of a private company and a public school. Due to surrounding structures restrictions, this project required a solution with rapidity in execution. In addition, as a requirement established by its owner, this structure should recover the original geometry of the slope. Besides the importance regarding surrounding constructions, an interesting aspect of this study case relies on the versatility of geosynthetic materials. A woven geotextile was used as reinforcement. Five other geosynthetic materials were used in this study case. Facing comprised a geocell filled with local soil cover and grass mats, resulting in a green facing. A geonet was used to hold the grass mats in place before grass roots development. Regarding the drainage system, geocomposite drains and geopipes were installed to drain subsurface water. A nonwoven geotextile was used as filter in drainage trenches, which were placed near the structure toe. Additionally to the GRS structure, the lower portion of the slope was reinforced with soil nailing technique. The face of the nailed soil portion was covered with sandbags and shotcrete. It emphasizes the flexibility of GRS structures regarding their application with other technical options in Geotechnical Engineering. The economic aspect of this study case also deserves attention. It did not require soil transportation and other design and construction steps, e.g. concrete structures design and construction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study evaluated the effect of quantity of resin composite, C-factor, and geometry in Class V restorations on shrinkage stress after bulk fill insertion of resin using two-dimensional finite element analysis.Methods: An image of a buccolingual longitudinal plane in the middle of an upper first premolar and supporting tissues was used for modeling 10 groups: cylindrical cavity, erosion, and abfraction lesions with the same C-factor (1.57), a second cylindrical cavity and abfraction lesion with the same quantity of resin (QR) as the erosion lesion, and then all repeated with a bevel on the occlusal cavosurface angle. The 10 groups were imported into Ansys 13.0 for two-dimensional finite element analysis. The mesh was built with 30,000 triangle and square elements of 0.1 mm in length for all the models. All materials were considered isotropic, homogeneous, elastic, and linear, and the resin composite shrinkage was simulated by thermal analogy. The maximum principal (MPS) and von Mises stresses (VMS) were analyzed for comparing the behavior of the groups.Results: Different values of angles for the cavosurface margin in enamel and dentin were obtained for all groups and the higher the angle, the lower the stress concentration. When the groups with the same C-factor and QR were compared, the erosion shape cavity showed the highest MPS and VMS values, and abfraction shape, the lowest. A cavosurface bevel decreased the stress values on the occlusal margin. The geometry factor overcame the effects of C-factor and QR in some situations.Conclusion: Within the limitations of the current methodology, it is possible to conclude that the combination of all variables studied influences the stress, but the geometry is the most important factor to be considered by the operator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we show that the electronic properties of multi-open dots structures are strongly modified by even smalt changes in their geometries. Our discussion of these effects is done in terms of the interaction among localized states (dot-like) and extended states (channel-like), from which a Fano resonance situation arises.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of the geometry and design of prosthetic crown preparations on stress distribution in compression tests, using finite element analysis (FEA). Materials and Methods: Six combinations of 3D drawings of all-ceramic crowns (yttria-stabilized zirconia framework and porcelain veneer) were evaluated: F, flat preparation and simplified crown; FC, flat preparation and crown with contact point; FCM, flat preparation and modified crown; A, anatomical preparation and simplified anatomical crown framework; AC, anatomical preparation and crown with contact point; and ACM, anatomical preparation and modified crown. Bonded contact types at all interfaces with the mesh were assigned, and the material properties used were according to the literature. A 200 N vertical load was applied at the center of each model. The maximum principal stresses were quantitatively and qualitatively analyzed. Results: The highest values of tensile stress were observed at the interface between the ceramics in the region under the load application for the simplified models (F and A). Reductions in stress values were observed for the model with the anatomical preparation and modified infrastructure (ACM). The stress distribution in the flat models was similar to that of their respective anatomical models. Conclusions: The modified design of the zirconia coping reduces the stress concentration at the interface with the veneer ceramic, and the simplified preparation can exert a stress distribution similar to that of the anatomical preparation at and near the load point, when load is applied to the center of the crown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: In view of reports in the literature on the benefits achieved with the use of platform switching, described as the use of an implant with a larger diameter than the abutment diameter, the goal being to prevent the (previously) normal bone loss down to the first thread that occurs around most implants, thus enhancing soft tissue aesthetics and stability and the need for implant inclination due to bone anatomy in some cases, the aim of this study was to evaluate bone stress distribution on peri-implant bone, by using three-dimensional finite element analysis to simulate the influence of implants with different abutment angulations (0 and 15 degrees) in platform switching. METHODS: Four mathematical models of an implant-supported central incisor were created with varying abutment angulations: straight abutment (S1 and S2) and angulated abutment at 15 degrees (A1 and A2), submitted to 2 loading conditions (100 N): S1 and A1-oblique loading (45 degrees) and S2 and A2-axial loading, parallel to the long axis of the implant. Maximum (σmax) and minimum (σmin) principal stress values were obtained for cortical and trabecular bone. RESULTS: Models S1 and A1 showed higher σmax in cortical and trabecular bone when compared with S2 and A2. The highest σmax values (in MPa) in the cortical bone were found in S1 (28.5), followed by A1 (25.7), S2 (11.6), and A2 (5.15). For the trabecular bone, the highest σmax values were found in S1 (7.53), followed by A1 (2.87), S2 (2.85), and A2 (1.47). CONCLUSIONS: Implants with straight abutments generated the highest stress values in bone. In addition, this effect was potentiated when the load was applied obliquely.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of switching platform is the use of an implant by platform wider than the abutment. Recently, researches have shown that this type of dental implant design tends to offer a higher preservation of crestal bone when compared to the traditional pattern of bone loss. The present study aims to perform a critical review on the switching platform concept establishing possible advantages of the technique. A search was performed on Medline/Pubmed about the topic “dental implant” and “platform switching”, and after applying inclusion criteria 40 studies were selected. The literature on longevity present prospective studies that show less bone loss, studies in biomechanics exhibit better or similar stress distribution around the bone crest, however, is not yet defined the role of the biological width. Thus, studies of longevity, and randomized prospective studies are of a great relevance to be performed in order to confirm the benefits of this technique and to establish a protocol indication. It is possible, based on this literature review, to conclude that longitudinal and randomized studies show that the platform switching implants have longevity and less bone loss. Biomechanically, the technique is possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dendrimers of poly (amidoamine) (PAMAM) are nanoparticles which have proven succeed in transporting drugs due to high solubility, low toxicity and ability to control drugs release. Studies have explored the biological potential of dendrimers such as to transport genes, development of vaccines, antiviral, antibacterial and anticancer therapies. This review of literature on the PAMAM dendrimers discusses the architecture and general construction of dendrimers and intrinsic properties of the PAMAM. This study also describes how the PAMAM interact with many drugs and the potential of these macromolecules as well as drug nanocarriers in transdermal routes of administration, ocular, respiratory, oral and intravenous administration. Dendrimers promises good future prospects for the biomedicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the importance of an innovative analytical technique for drugs and pharmaceuticals quantification, using Fouriertransform infrared (FTIR) transmission spectroscopy. This method does not use organic solvents, which is one great advantage over the most common analytical methods. This fact contributes to minimize the generation of organic solvent waste by the industry and thereby reduces the impact of its activities on the environment. The method involved absorbance measurements of the band corresponding to one of the chosen group in the molecule. Obviously, the method should be validated according to ICH guidelines, showing linearity, precision, accuracy and robustness, over a concentration range, using small amounts to prepare the analyte. The validated method is able to quantify drugs and pharmaceuticals and can be used as an environmentally friendly alternative for the routine analysis in pharmaceutical industry quality control.