900 resultados para UROLOGIC SURGICAL PROCEDURES
Resumo:
The ligaments of the wrist are highly variable and poorly described, which is more obvious on the ulnar side of the wrist. Previous studies highlighted the potential differences within the ligaments of the wrist but no consensus has been reached. Poor tissue description and inconsistent use of terminology hindered the reproducibility of the results. Improved understanding of the morphological variations between carpal bones may facilitate improved understanding of the ligamentous structure within the wrist. This study aims to identify the potential variations between carpal bones that could be used to separate palmar ligamentous patterns around the triquetrum-hamate joint into subgroups within the sample population. Investigations were performed following a detailed nomenclature and a clear definition of ligamentous structures to facilitate detailed description and reproducible results. Quantitative analyses were conducted using 3D modelling technique. Histological sections were then analysed to identify the structure of each ligamentous attachment. Variable patterns of ligamentous attachments were identified. Differences were not only obvious between samples but also between the right and left hands of the same person. These identifications suggested that the palmar ligamentous patterns around the triquetrum-hamate joint are best described as a spectrum with a higher affinity of the triquetrum-hamate-capitate ligament and the lunate-triquetrum ligament to be associated with type I lunate wrists on one extreme and type II lunate wrists with the palmar triquetrum-hamate ligament, triquetrum-hamate-capitate ligament and palmar radius-lunate-triquetrum ligament attachments at the other extreme. Histological analyses confirmed pervious established work regarding the mechanical role of ligaments in wrist joint biomechanics. Also, there were no significant differences between the quantitative data obtained from the Genelyn-embalmed and unembalmed specimens (p>0.05). The current study demonstrated variable ligamentous patterns that suggest different bone restraints and two different patterns of motion. These findings support previous suggestions regarding separating the midcarpal joint into two distinct functional types. Type I wrists were identified with ligamentous attachments that are suggestive of rotating/translating hamate whilst type II wrists identified with ligamentous attachments that are suggestive of flexing/extending hamate motion based upon the patterns of the ligamentous attachments in relation to the morphological features of the underlying lunate type of the wrist. This opens the horizon for particular consideration and/or modification of surgical procedures, which may enhance the clinical management of wrist dysfunction.
Resumo:
As tecnologias de saúde, nomeadamente medicamentos, dispositivos médicos (DM), procedimentos médicos ou cirúrgicos, entre outros, têm ocupado uma posição de destaque no setor da saúde, e na vida dos seus utilizadores. A inovação e utilização de tecnologias de saúde, e consequente aumento das despesas fizeram emergir a necessidade de avaliação das tecnologias de saúde. Surge assim, a avaliação de tecnologias de saúde (ATS), que tem por objetivo abordar os impactos clínicos, económicos, organizacionais, sociais, legais e éticos de uma tecnologia de saúde, considerando o seu contexto médico específico, bem como as alternativas disponíveis. A ATS pretende que os processos sejam feitos de forma rigorosa, transparente, valorizando e garantindo a sustentabilidade do acesso aos cuidados em saúde. Seguindo a tendência europeia de implementação de políticas e modelos de ATS, Portugal criou o seu próprio sistema de avaliação de tecnologias. O Decreto-Lei nº 97/2015, de 1 de junho veio oficializar a criação do Sistema Nacional de Avaliação de Tecnologias de Saúde (SiNATS). O SiNATS vai permitir uma avaliação não só de medicamentos, mas também de DM e outras tecnologias tendo em consideração a avaliação técnica, terapêutica e económica das tecnologias de saúde com base em fatores sociais, políticos, éticos e a participação de entidades, como, a indústria, as instituições de ensino, as instituições de saúde, os investigadores, os profissionais de saúde, os doentes e as associações dos doentes. O SiNATS vai emitir recomendações e decisões sobre o uso das tecnologias de saúde e possibilitar o ganho em saúde e contribuir para a sustentabilidade do Serviço Nacional de Saúde (SNS). O SiNATS vem permitir a avaliação de DM. O sector dos DM é um sector caracterizado pela inovação, crescimento e também competitividade. A complexidade e especificidade deste sector devem por isso ser tidas em consideração aquando da sua análise. A implementação do SiNATS permitirá avaliar e reavaliar preços, comparticipações, recomendações, contratos ao longo do ciclo de vida de cada DM. No presente momento, ainda é difícil expor os processos através dos quais esta avaliação vai ser processada, uma vez que se aguarda a publicação de despachos e portarias referidos no Decreto-Lei nº 97/2015, de 1 de junho. Tendo em consideração a partilha de informação sobre políticas, métodos, procedimentos de ATS aplicada aos DM na Europa, foram analisados os casos de França e do Reino Unido com o objetivo de alargar o conhecimento acerca do que já é feito a nível Europeu e explorar se os mesmos poderiam ser adaptados à realidade portuguesa. Em França, a ATS está diretamente relacionada com a comparticipação de DM, já no Reino Unido, o National Institute and Centre of Excellence (NICE) tem a responsabilidade de avaliar os DM segundo procedimentos de ATS, mas não está diretamente relacionado com comparticipação. O NICE publica normas de orientação que auxiliam a decisão de aquisição ou não de um DM. Tendo em consideração a informação reunida e descrita, este trabalho também propõe um modelo hipotético sobre o sistema português de avaliação de DM. Este modelo aborda, ainda que não de forma exaustiva, os possíveis processos e procedimentos para a avaliação de DM. Este sistema caracteriza-se pela importância dada ao envolvimento dos stakeholders e partilha de informação com os mesmos, mas também na agilização dos processos, isto é, uma redução e simplificação dos processos de avaliação de DM. A reavaliação de DM durante a sua comercialização também ganha destaque, apontando que cada grupo genérico de dispositivos ou DM inovador dever ser reavaliado a cada cinco anos, ou sempre que informação emergente o justifique. Este modelo representa uma abordagem experimental sobre o futuro do SiNATS aplicado aos DM. A partilha de informação, os fóruns de discussão e o envolvimento da sociedade serão uma mais-valia para que a implementação do SiNATS aos DM seja feita de forma gradual e com a máxima transparência possível.
Resumo:
Enquadramento: O carácter inovador da Cirurgia de Ambulatório reside no seu modelo organizativo específico, centrado no doente, que o envolve num circuito independente do de internamento, procurando-se ganhos em eficiência e em qualidade e obtendo-se níveis de maior humanização e satisfação dos utentes e seus familiares. Objetivos: Analisar de que forma as variáveis sociodemográficos influenciam a qualidade percebida dos utentes de uma Unidade de Cirurgia de Ambulatório de um Hospitalar Central; verificar se existem efeitos significativos das variáveis circunstanciais na qualidade percebida dos utentes de uma Unidade de Cirurgia de Ambulatório de um Hospitalar Central; verificar a existência de efeitos significativos das variáveis sociofamiliares na qualidade percebida nos utentes. Métodos: Estudo quantitativo, com corte transversal, descritivo e correlacional; enquadra-se num estudo descritivo analítico-correlacional porque o mesmo tem por objetivo explorar as relações entre variáveis e descrevê-las. Os dados foram colhidos junto dos utentes tendo como base escalas e questionários. A amostra é não probabilística por conveniência, constituída por 140 utentes de uma Unidade de Cirurgia de Ambulatório de um Hospitalar Central, na maioria, do sexo masculino (60,7%), com uma idade mínima de 19 anos e uma máxima de 94 anos, ao que corresponde uma idade média de 58,01 (±19.26 anos). Foi aplicado um Questionário de caracterização sociodemográfica e sociofamiliar, incluindo-se o Questionário (Medical Outcomes Study Social Support Survey) MOS-SSS (Fachado et al., 2007) e o Questionário Service Quality (SERVQUAL) (Parasuraman et al., 1988). Resultados: Os utentes do sexo feminino manifestam mais satisfação em relação à UCA (cortesia/empatia p=0.000; compreensão do utente p=0.000; fiabilidade p=0.005; acessibilidade p=0.010; qualidade global p=0.001; os utentes idosos obtiveram valores mais elevados em quase todas as dimensões e na qualidade global (aspetos físicos p=0.006); os participantes com o ensino básico manifestaram mais satisfação (fiabilidade p<0,016); os que possuem um rendimento familiar até 1000€ apresentaram maior nível de satisfação (cortesia/empatia p=0,033); os utentes que não se deslocam em meio de transporte próprio atribuem mais qualidade à UCA (fiabilidade p=0,028); aqueles cuja residência está situada a uma distância superior a 15 km do hospital revelam índices mais elevados de qualidade (cortesia/simpatia p=0.037; compreensão do utente p=0.044; fiabilidade p=0.022; acessibilidade p=0.001; qualidade global p=0.013); os participantes cuja distância de casa ao centro de saúde é superior a 9 km revelam mais satisfação (fiabilidade p=0.038); os utentes com tempos de espera para a cirurgia entre 6-12 meses atribuem mais qualidade à UCA (cortesia/empatia p=0.000; compreensão do utente p=0.011; fiabilidade p=0.007; acessibilidade p=0.001; qualidade global p=0.001). Conclusão: A maioria dos utentes atribui qualidade à UCA, tendo em conta a cortesia/empatia, a compreensão do utente, fiabilidade, acessibilidade e aspetos físicos, pode afirmar-se que a referida Unidade adequa os serviços prestados às suas necessidades, garantindo, deste modo, a satisfação dos utentes. Palavras-chave: Cirurgia de Ambulatório; Satisfação dos utentes; Qualidade; Atendimento.
Resumo:
Congenital heart disease (CHD) is the most common birth defect, causing an important rate of morbidity and mortality. Treatment of CHD requires surgical correction in a significant percentage of cases which exposes patients to cardiac and end organ injury. Cardiac surgical procedures often require the utilisation of cardiopulmonary bypass (CPB), a system that replaces heart and lungs function by diverting circulation into an external circuit. The use of CPB can initiate potent inflammatory responses, in addition a proportion of procedures require a period of aortic cross clamp during which the heart is rendered ischaemic and is exposed to injury. High O2 concentrations are used during cardiac procedures and when circulation is re-established to the heart which had adjusted metabolically to ischaemia, further injury is caused in a process known as ischaemic reperfusion injury (IRI). Several strategies are in place in order to protect the heart during surgery, however injury is still caused, having detrimental effects in patients at short and long term. Remote ischaemic preconditioning (RIPC) is a technique proposed as a potential cardioprotective measure. It consists of exposing a remote tissue bed to brief episodes of ischaemia prior to surgery in order to activate protective pathways that would act during CPB, ischaemia and reperfusion. This study aimed to assess RIPC in paediatric patients requiring CHD surgical correction with a translational approach, integrating clinical outcome, marker analysis, cardiac function parameters and molecular mechanisms within the cardiac tissue. A prospective, single blinded, randomized, controlled trial was conducted applying a RIPC protocol to randomised patients through episodes of limb ischaemia on the day before surgery which was repeated right before the surgery started, after anaesthesia induction. Blood samples were obtained before surgery and at three post-operative time points from venous lines, additional pre and post-bypass blood samples were obtained from the right atrium. Myocardial tissue was resected during the ischaemic period of surgery. Echocardiographic images were obtained before the surgery started after anaesthetic induction and the day after surgery, images were stored for later off line analysis. PICU surveillance data was collected including ventilation parameters, inotrope use, standard laboratory analysis and six hourly blood gas analysis. Pre and post-operative quantitation of markers in blood specimens included cardiac troponin I (cTnI) and B-type natriuretic peptide (BNP), inflammatory mediators including interleukins IL-6, IL-8, IL-10, tumour necrosis factor (TNF-α), and the adhesion molecules ICAM-1 and VCAM-1; the renal marker Cystatin C and the cardiovascular markers asymmetric dymethylarginine (ADMA) and symmetric dymethylarginine (SDMA). Nitric oxide (NO) metabolites and cyclic guanosine monophosphate (cGMP) were measured before and after bypass. Myocardial tissue was processed at baseline and after incubation at hyperoxic concentration during four hours in order to mimic surgical conditions. Expression of genes involved in IRI and RIPC pathways was analysed including heat shock proteins (HSPs), toll like receptors (TLRs), transcription factors nuclear factor κ-B (NF- κ-B) and hypoxia inducible factor 1 (HIF-1). The participation of hydrogen sulfide enzymatic genes, apelin and its receptor were explored. There was no significant difference according to group allocation in any of the echocardiographic parameters. There was a tendency for higher cTnI values and inotropic score in control patients post-operatively, however this was not statistically significant. BNP presented no significant difference according to group allocation. Inflammatory parameters tended to be higher in the control group, however only TNF- α was significantly higher. There was no difference in levels of Cystatin C, NO metabolites, cGMP, ADMA or SDMA. RIPC patients required shorter PICU stay, all other clinical and laboratory analysis presented no difference related to the intervention. Gene expression analysis revealed interesting patterns before and after incubation. HSP-60 presented a lower expression at baseline in tissue corresponding to RIPC patients, no other differences were found. This study provided with valuable descriptive information on previously known and newly explored parameters in the study population. Demographic characteristics and the presence of cyanosis before surgery influenced patterns of activity in several parameters, numerous indicators were linked to the degree of injury suffered by the myocardium. RIPC did not reduce markers of cardiac injury or improved echocardiographic parameters and it did not have an effect on end organ function; some effects were seen in inflammatory responses and gene expression analysis. Nevertheless, an important clinical outcome indicator, PICU length of stay was reduced suggesting benefit from the intervention. Larger studies with more statistical power could determine if the tendency of lower injury and inflammatory markers linked to RIPC is real. The present results mostly support findings of larger multicentre trials which have reported no cardiac benefit from RIPC in paediatric cardiac surgery.
Resumo:
Voir aussi : F. Plumereau, S. Mucci, P. Le Naoures, J.B. Finel, A. Hamy. Ischémie mésentérique aiguë d’étiologie artérielle : intérêt d’une revascularisation précoce. Journal de Chirurgie Viscérale, Volume 152, Issue 1, February 2015, pp. 16-21. doi:10.1016/j.jchirv.2014.07.014
Resumo:
Background There is a potential risk of infection with blood-borne viruses if a doctor receives a blood splash to a mucous membrane. The quantification of facial contamination with blood has never been documented in the context of dermatological surgery. Objectives (i) To identify the number of facial blood splashes that occur during skin surgery and to identify the procedures that present higher risks for the operator and assistant. (ii) To assess the provision of eye protection and attitudes to its use in dermatological surgery in the U.K. Methods (i) Prospective, observational study in the skin surgery suite of a U.K. teaching hospital assessing 100 consecutive dermatological surgery procedures, plus 100 consecutive operations in which an assistant was present. Primary outcome: number of face-mask visors with at least one blood splash. Secondary outcomes: to identify if any of the following variables influenced the occurrence of a blood splash: grade of operator, site and type of procedure, and the use of electrocautery. (ii) A postal survey of all U.K.-based members of the British Society of Dermatological Surgery (BSDS) was conducted assessing facilities available and the attitudes of U.K.-based clinicians to the use of face masks during surgery. Results (i) In 33% of all surgical procedures there was at least one facial splash to the operator (range 1–75) and in 15% of procedures the assistant received at least one splash (range 1–11). Use of monopolar electrocautery was significantly less likely to result in splashes to the mask compared with bipolar electrocautery [odds ratio (OR) 0Æ04; 95% confidence interval (CI) 0Æ01–0Æ19]. Compared with the head/neck, operations on the body were significantly more likely to result in splashes to the mask (OR 6Æ52) (95% CI 1Æ7–25Æ07). The type of procedure and the status of the operator did not have a bearing on the likelihood of receiving a splash to the mask. (ii) From the survey, 33 of 159 (20Æ8%) of BSDS members had no face masks available and 54 of 159 (34Æ0%) did not wear any facial protection while operating. The majority (53Æ5%) thought they received a splash in £ 1% of procedures. Conclusions There is a substantial risk of a splash of blood coming into contact with the face during dermatological surgery for both the operator and assistant, regardless of the procedure. The risk of receiving a blood splash to the face may be substantially underestimated by U.K.-based dermatologists. The use of protective eyewear is advisable at all times, but particularly when using bipolar electrocautery, or when operating on high-risk individuals.
Resumo:
Introduction: One of the most common strategies for pain control during and after surgical procedures is the use of local anesthetics. Prolonged analgesia can be safely achieved with drug delivery systems suitably chosen for each local anesthetic agent.Areas covered: This review considers drug delivery formulations of local anesthetics designed to prolong the anesthetic effect and decrease toxicity. The topics comprise the main drug delivery carrier systems (liposomes, biopolymers, and cyclodextrins) for infiltrative administration of local anesthetics. A chronological review of the literature is presented, including details of formulations as well as the advantages and pitfalls of each carrier system. The review also highlights pharmacokinetic data on such formulations, and gives an overview of the clinical studies published so far concerning pain control in medicine and dentistry.Expert opinion: The design of novel drug delivery systems for local anesthetics must focus on how to achieve higher uploads of the anesthetic into the carrier, and how to sustain its release. This comprehensive review should be useful to provide the reader with the current state-of-art regarding drug delivery formulations for local anesthetics and their possible clinical applications.
Resumo:
Ropivacaine (RVC) is an enantiomerically pure local anesthetic (LA) largely used in surgical procedures, which presents physico-chemical and therapeutic properties similar to those of bupivacaine (BPV), but associated to less systemic toxicity This study focuses on the development and pharmacological evaluation of a RVC in 2-hydroxypropyl-beta-cyclodextrin (HP-P-CD) inclusion complex. Phase-solubility diagrams allowed the determination of the association constant between RVC and HP-beta-CD (9.46 M-1) and showed an increase on RVC solubility upon complexation. Release kinetics revealed a decrease on RVC release rate and reduced hemolytic effects after complexation. (onset at 3.7 mM and 11.2 mM for RVC and RVCHP-beta-CD, respectively) were observed. Differential scanning calorimetry (DSC), scanning electron microscopy (SEM) and X-ray analysis (X-ray) showed the formation and the morphology of the complex. Nuclear magnetic resonance (NMR) and job-plot experiments afforded data regarding inclusion complex stoichiometry (1:1) and topology. Sciatic nerve blockade studies showed that RVCHP-beta-CD was able to reduce the latency without increasing the duration of motor blockade, but prolonging the duration and intensity of the sensory blockade (p < 0.001) induced by the LA in mice. These results identify the RVCHP-beta-CD complex as an effective novel approach to enhance the pharmacological effects of RVC, presenting it as a promising new anesthetic formulation. (c) 2007 Elsevier B.V All rights reserved.
Resumo:
Dissertação de Mestrado Integrado em Medicina Veterinária
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Instituto de Ciências Biológicas, Departamento de Biologia Molecular, 2016.
Resumo:
With the advances in medicine, life expectancy of the world population has grown considerably in recent decades. Studies have been performed in order to maintain the quality of life through the development of new drugs and new surgical procedures. Biomaterials is an example of the researches to improve quality of life, and its use goes from the reconstruction of tissues and organs affected by diseases or other types of failure, to use in drug delivery system able to prolong the drug in the body and increase its bioavailability. Biopolymers are a class of biomaterials widely targeted by researchers since they have ideal properties for biomedical applications, such as high biocompatibility and biodegradability. Poly (lactic acid) (PLA) is a biopolymer used as a biomaterial and its monomer, lactic acid, is eliminated by the Krebs Cycle (citric acid cycle). It is possible to synthesize PLA through various synthesis routes, however, the direct polycondensation is cheaper due the use of few steps of polymerization. In this work we used experimental design (DOE) to produce PLAs with different molecular weight from the direct polycondensation of lactic acid, with characteristics suitable for use in drug delivery system (DDS). Through the experimental design it was noted that the time of esterification, in the direct polycondensation, is the most important stage to obtain a higher molecular weight. The Fourier Transform Infrared (FTIR) spectrograms obtained were equivalent to the PLAs available in the literature. Results of Differential Scanning Calorimetry (DSC) showed that all PLAs produced are semicrystalline with glass transition temperatures (Tgs) ranging between 36 - 48 °C, and melting temperatures (Tm) ranging from 117 to 130 °C. The PLAs molecular weight characterized from Size Exclusion Chromatography (SEC), varied from 1000 to 11,000 g/mol. PLAs obtained showed a fibrous morphology characterized by Scanning Electron Microscopy (SEM)
Resumo:
Tese (doutorado)—Universidade de Brasília, Faculdade de Medicina, Programa de Pós-Graduação em Ciências Médicas, 2016.
Resumo:
Magnesium alloys have been widely explored as potential biomaterials, but several limitations to using these materials have prevented their widespread use, such as uncontrollable degradation kinetics which alter their mechanical properties. In an attempt to further the applicability of magnesium and its alloys for biomedical purposes, two novel magnesium alloys Mg-Zn-Cu and Mg-Zn-Se were developed with the expectation of improving upon the unfavorable qualities shown by similar magnesium based materials that have previously been explored. The overall performance of these novel magnesium alloys has been assessesed in three distinct phases of research: 1) analysing the mechanical properties of the as-cast magnesium alloys, 2) evaluating the biocompatibility of the as-cast magnesium alloys through the use of in-vitro cellular studies, and 3) profiling the degradation kinetics of the as-cast magnesium alloys through the use of electrochemical potentiodynamic polarization techqnique as well as gravimetric weight-loss methods. As compared to currently available shape memory alloys and degradable as-cast alloys, these experimental alloys possess superior as-cast mechanical properties with elongation at failure values of 12% and 13% for the Mg-Zn-Se and Mg-Zn-Se alloys, respectively. This is substantially higher than other as-cast magnesium alloys that have elongation at failure values that range from 7-10%. Biocompatibility tests revealed that both the Mg-Zn-Se and Mg-Zn-Cu alloys exhibit low cytotoxicity levels which are suitable for biomaterial applications. Gravimetric and electrochemical testing was indicative of the weight loss and initial corrosion behavior of the alloys once immersed within a simulated body fluid. The development of these novel as-cast magnesium alloys provide an advancement to the field of degradable metallic materials, while experimental results indicate their potential as cost-effective medical devices.
Resumo:
Introducción: El incremento de pacientes sintomáticos de rodilla y la osteoartrosis en jóvenes con limitadas posibilidades terapéuticas después de una meniscectomía, genera la búsqueda de alternativas terapéuticas. A pesar que es poco utilizado en Colombia, el trasplante meniscal es una propuesta para el manejo sintomático. Según cifras norteamericanas, se practican entre 700.000 a 1.500.000 artroscopias de rodilla anualmente, el 50% termina en meniscectomía y de este un 40% persisten sintomáticos. Métodos: Estudio de cohorte retrospectivo, con el objetivo de evaluar dolor (Escala Visual Análoga-EVA) y funcionalidad (Escala de Tegner y Lysholm) en los pacientes a quienes se les realizó trasplante meniscal o meniscectomía por segunda vez, entre los años 2007 a 2015. Resultados: A partir de los 6 meses la EVA mostró una tendencia a la mejoría en el grupo de trasplante meniscal, pasando de Moderado a Leve (p: <0.000). La Escala de Tegner y Lysholm cambió de Pobre a Bueno en el grupo de segunda meniscectomía (p= 0.008) y de Bueno a Excelente en el grupo trasplantado (p=0.225). La calificación promedio de la EVA en el grupo de trasplante presentó mejoría (p=<0.000), a diferencia del grupo de segunda meniscectomía (p=0.591). La escala de Tegner y Lysholm, mostró significancia estadística con tendencia a la mejoría en el grupo de segunda meniscectomía. Discusión: Los resultados muestran que con trasplante meniscal hay mejoría del dolor y la funcionalidad versus un segunda meniscectomía. Para fortalecer la evidencia de este tratamiento son necesarios estudios prospectivos complementarios.
Resumo:
Introduccion: El canal lumbar estrecho es un motivo de consulta frecuente en el servicio de columna de la Fundación Santa Fe de Bogotá. Derivado del tratamiento quirurgico se pueden generar múltiples complicaciones, entre las que se encuentra la transfusión sanguínea. Objetivo: Identificar los factores sociodemográficos, antecedentes personales y factores quirúrgicos asociados a transfusión sanguínea en cirugía canal lumbar estrecho en la Fundación Santa Fe de Bogotá 2003- 2013. Materiales y métodos: Se aplicó en diseño de estudio observacional analítico transversal. Se incluyeron 367 pacientes sometidos a cirugía de canal lumbar estrecho a quienes se les analizaron variables de antecedentes personales, características sociodemograficas y factores quirúrgicos. Resultados: La mediana de la edad fue de 57 años y la mayoría de pacientes fueron mujeres (55,6%). La mediana del Índice de Masa Corporal (IMC) fue de 24,9 clasificado como normal. Entre los antecedentes patológicos, la hipertensión arterial fue el más común (37,3%). La mayoría de pacientes (59,1%) presentaron clasificación ASA de II. El tipo de cirugía más prevalente fue el de descompresión (55,6%). En el 79,8% de los pacientes se intervinieron 2 niveles. Se realizó transfusión de glóbulos rojos en 26 pacientes correspondiente a 7,1% del total. En la mayoría de procedimientos quirúrgicos (42,5%) el sangrado fue clasificado como moderado (50-500 ml). En el modelo explicativo transfusión sanguínea en cirugía de canal lumbar estrecho se incluyen: antecedente de cardiopatía (OR 4,68, P 0,034, IC 1,12 – 19,44), Sangrado intraoperatorio >500ml (OR 6,74, p 0,001, 2,09 – 21,74) y >2 niveles intervenidos (OR 3,97, p 0,023, IC 1,20 – 13,09). Conclusión: Como factores asociados a la transfusión sanguínea en el manejo quirúrgico del canal lumbar estrecho a partir de la experiencia de 10 años en la Fundación Santa Fe de Bogotá se encontraron: enfermedad cardiaca, sangrado intraoperatorio mayor de 500ml y más de dos niveles intervenidos.