929 resultados para HIGH-SPEED
Resumo:
A gate-modulated nanowire oxide photosensor is fabricated by electron-beam lithography and conventional dry etch processing.. The device characteristics are good, including endurance of up to 10(6) test cycles, and gate-pulse excitation is used to remove persistent photoconductivity. The viability of nanowire oxide phototransistors for high speed and high resolution applications is demonstrated, thus potentially expanding the scope of exploitation of touch-free interactive displays.
Resumo:
The dynamic response of end-clamped sandwich and monolithic beams of equal areal mass subjected to loading via high-velocity slugs of dry and water-saturated sand is measured using a novel laboratory-based method. The sandwich beams comprise aluminium face sheets and an aluminium honeycomb core: the effect of sandwich core strength and beam thickness on the dynamic beam deflection is investigated by varying the orientation and height of the anisotropic aluminium honeycomb core material. High-speed imaging is used to measure the transient transverse deflection of the beams and to record the dynamic modes of deformation. The measurements show that sandwich beams with thick, strong cores are optimal and that these beams significantly outperform monolithic beams of equal mass. The water-saturated sand slugs cause significantly higher deflections compared to the dry sand slugs having the same mean slug velocity and we demonstrate that this enhanced deflection is due to the larger mass of the water-saturated slugs. Finally, we show that the impact of sand slugs is equivalent to the impact of a crushable foam projectile. The experiments using foam projectiles are significantly simpler to perform and thus represent a more convenient laboratory technique. © 2014 Elsevier Ltd. All rights reserved.
Resumo:
An electroabsorption modulator using an intra-step quantum well (IQW) active region is fabricated for a radio over fibre system. The strain-compensated InGaAsP/InGaAsP IQW shows good material quality and improved modulation properties, high extinction ratio efficiency (10 dB V-1) and low capacitance (< 0.42 pF), with which high frequency (> 15 GHz) can be obtained. High-speed measurement under high-power excitation shows no power saturation up to an excitation power of 21 dBm. To our knowledge, the input optical power is the highest reported for a multi-quantum well EAM without a heat sink.
Resumo:
An electroabsorption modulator using the intrastep quantum well (IQW) active region is fabricated for optical network systems. The strain-compensated InGaAsP/InGaAsP IQW shows good material quality and improved modulation properties, high extinction ratio elliciency 10 dB/V and low capacitance (< 0.42 pF), with which an ultra high frequency (> 15 GHz) can be obtained. High-speed measurement under high-power excitation shows no power saturation up to excitation power of 21 dBm. To our knowledge, the input optical power is the highest reported for multi-quantum well EAMs without heat sinks.
Resumo:
A 1.55 mu m low-temperature-grown GaAs (LT-GaAs) photodetector with a resonant-cavityenhanced structure was designed and fabricated. A LT-GaAs layer grown at 200 degrees C was used as the absorption layer. Twenty- and fifteen-pair GaAs/AlAs-distributed Bragg reflectors were grown as the bottom and top mirrors. A responsivity of 7.1 mA/W with a full width at half maximum of 4 nm was obtained at 1.61 mu m. The dark current densities are 1.28x10(-7) A/cm(2) at the bias of 0 V and 3.5x10(-5) A/cm(2) at the reverse bias of 4.0 V. The transient response measurement showed that the photocarrier lifetime in LT-GaAs is 220 fs. (c) 2006 American Institute of Physics.
Resumo:
A high quality (Q) factor microring resonator in silicon-on-insulator rib waveguides was fabricated by electron beam lithography, followed by inductively coupled plasma etching. The waveguide dimensions were scaled down to submicron, for a low bending loss and compactness. Experimentally, the resonator has been realized with a quality factor as high as 21,200, as well as a large extinction ratio 12.5dB at telecommunication wavelength near 1550nm. From the measured results, propagation loss in the rib waveguide is determined as low as 6.900/cm. This high Q microring resonator is expected to lead to high speed optical modulators and bio-sensing devices.
Resumo:
The wideband high-linearity mixers for a double conversion cable TV tuner is presented. The up-conversion mixer converts the input signal from 100MHz to 1000 MHz to the intermediate frequency (IF) of I GHz above. And the down-conversion mixer converts the frequency back. The degeneration resistors are used to Improve the linearity. The tuner is implemented in a 0.35 mu m SiGe technology. Input power at 1dB compression point can reach +14.23dBm. The lowest noise figure is 17.5dB. The two mixers consume 103mW under a supply voltage of 5 V.
Resumo:
This paper presents the design of a wide-band low-noise amplifier (LNA) implemented in a 0.35 mu m SiGe BiCMOS technology for cable (DVB-C) and terrestrial (DVB-T) tuner applications. The LNA utilizes current injection to achieve high linearity. Without using inductors, the LNA achieves 0.1-1GHz wide bandwidth and 18.8-dB gain with less than 1.4-dB gain variation. The noise figure(NF) of the wideband LNA is 5dB, its 1-dB compression point is -2dBm and IIP3 is 8dBm. The LNA dissipates 120mW power with a 5-V supply.
Resumo:
We present an efficient method to generate a ultrashort attosecond (as) pulse when a model He+ ion is exposed to the combination of an intense few-cycle chirped laser pulse and its 27th harmonics. By solving the time-dependent Schroumldinger equation, we found that high-order harmonic generation (HHG) from He+ ion is enhanced by seven orders of magnitude due to the presence of the harmonic pulse. After optimizing the chirp of the fundamental pulse, we show that the cut-off energy of the generated harmonics is extended effectively to I-p+25.5U(p). As a result, an isolated 26-as pulse with a bandwidth of 170.5 eV can be obtained directly from the supercontinuum around the cut-off of HHG. To better understand the physical origin of HHG enhancement and attosecond pulse emission, we perform semiclassical simulations and analyze the time-frequency characteristics of attosecond pulse.
Resumo:
Direction repulsion describes the phenomenon in which observers typically overestimate the direction difference between two superimposed motions moving in different directions (Marshak & Sekuler, Science 205(1979) 1399). Previous research has found that, when a relatively narrow range of distractor speeds is considered, direction repulsion of a target motion increases monotonically with increasing speed of the distractor motion. We sought to obtain a more complete measurement of this speed-tuning function by considering a wider range of distractor speeds than has previously been used. Our results show that, contrary to previous reports, direction repulsion as a function of distractor speed describes an inverted U-function. For a target of 2.5deg/s, we demonstrate that the attenuation of repulsion magnitude with high-speed disractors can be largely explained in terms of the reduced apparent contrast of the distractor. However, when we reduce target motion speed, this no longer holds. When considered from the perspective of Edwards et al.s (Edwards, Badcock, & Smith, Vision Research 38 (1998) 1573) two global-motion channels, our results suggest that direction repulsion is speed dependent when the distractor and target motions are processed by different globalmotion channels, but is not speed dependent when both motions are processed by the same, high-speed channel. The implications of these results for models of direction repulsion are discussed.
Resumo:
Purpose Poor water-solubility of BCS class II drugs can limit their commercialization because of reduced oral bioavailability. It has been reported that loading of drug by adsorption onto porous silica would enhance drug solubility due to the increased surface area available for solvent diffusion. In this work, solid dispersions are formed using supercritical carbon dioxide (scCO2). The aim of this research was to characterise the solid-state properties of scCO2 dispersion and to investigate the impact of altering scCO2 processing conditions on final amorphous product performance that could lead to enhancement of drug dissolution rate for BCS class II drugs. Methods Indomethacin (IND) was purchased from Sigma-Aldrich (Dorset, UK) and was used as a model drug with two grades of high surface area silica (average particle sizes 3&[micro] and 7&[micro]), which were obtained directly from Grace-Davison (Germany). Material crystallinity was evaluated using powder X-ray diffraction (PXRD, Rigaku™, miniflex II, Japan) and high-speed differential scanning calorimetry (Hyper-DSC 8000, Perkin Elmer, USA). Materials were placed in a high-pressure vessel consisting of a CO2 cylinder, a Thar™ Technologies P50 high-pressure pump and a 750 ml high-pressure vessel (Thar, USA). Physical mixtures were exposed to CO2 gas above its critical conditions. SEM imaging and elemental analysis were conducted using a Jeol 6500 FEGSEM (Advanced MicroBeam Inc., Austria). Drug release was examined using USP type II dissolution tester (Caleva™, UK). Results The two grades of silica were found to be amorphous using PXRD and Hyper-DSC. Using PXRD, it was shown that an increase in incubation time and pressure resulted in a decrease in the crystalline content. Drug release profiles from the two different silica formulations prepared under the same conditions are shown in Figure 1. It was found that there was a significant enhancement in drug release, which was influenced, by silica type and other experiment conditions such as temperature, pressure and exposure time. SEM imaging and elemental analysis showed drug deposited inside silica pores as well as on the outer surface. Conclusion This project has shown that silica carrier platforms may be used as an alternative approach to generating polymeric solid dispersions of amorphous drugs exhibiting enhanced solubility.
Resumo:
The thesis focuses on efficient design methods and reconfiguration architectures suitable for higher performance wireless communication .The work presented in this thesis describes the development of compact,inexpensive and low power communication devices that are robust,testable and capable of handling multiple communication standards.A new multistandard Decimation Filter Design Toolbox is developed in MATLAB GUIDE environment.RNS based dual-mode decimation filters reconfigurable for WCDMA/WiMAX and WCDMA/WLANa standards are designed and implemented.It offers high speed operation with lesser area requirement and lower dynamic power dissipation.A novel sigma-delta based direct analog-to-residue converter that reduces the complexity of RNS conversion circuitry is presented.The performance of an OFDM communication system with a new RRNS-convolutional concatenated coding is analysed and improved BER performance is obtained under different channel conditions. Easily testable MAC units for filters are presented using Reed-Muller logic for realization.
Resumo:
We present a first overview of flows in the high latitude ionosphere observed at 15 s resolution using the U.K.-Polar EISCAT experiment. Data are described from experiments conducted on two days, 27 October 1984 and 29 August 1985, which together span the local times between about 0200 and 2130MLT and cover five different regions of ionospheric flow. With increasing local time, these are: the dawn auroral zone flow cell, the dayside region of low background flows equatorward of the flow cells, the dusk auroral zone flow cell, the boundary region between the dusk auroral zone and the polar cap, and the evening polar cap. Flows in both the equatorward and poleward portions of the auroral zone cells appear to be relatively smooth, while in the central region of high speed flow considerable variations are generally present. These have the form of irregular fluctuations on a wide range of time scales in the early morning dawn cell, and impulsive wave-like variations with periods of a few minutes in the afternoon dusk cell. In the dayside region between the flow cells, the ionosphere is often essentially stagnant for long intervals, but low amplitude ULF waves with a period of about 5 min can also occur and persist for many cycles. These conditions are punctuated at one to two hour intervals by sudden ‘flow burst’ events with impulsively generated damped wave trains. Initial burst flows are generally directed poleward and can peak at line-of-sight speeds in excess of 1 km s^{−1} after perhaps 45 s. Flows in the polar cap are reasonably smooth on time scales of a few minutes and show no evidence for the presence of ULF waves. Under most, but not all, of the above conditions, the beam-swinging algorithm used to determine background vector flows should produce meaningful results. Comparison of these flow data with simultaneous plasma and magnetic field measurements in the solar wind, made by the AMPTE IRM and UKS spacecraft, emphasizes the strong control exerted on high latitude flows by the north-south component of the IMF.
Resumo:
O Mercado Acionário Americano evoluiu rapidamente na última década. Este tornou-se uma arquitetura aberta em que participantes com tecnologia inovadora podem competir de forma eficaz. Várias mudanças regulatórias e inovações tecnológicas permitiram mudanças profundas na estrutura do mercado. Essas mudanças, junto com o desenvolvimento tecnológico de redes de alta velocidade, agiu como um catalisador, dando origem a uma nova forma de negociação, denominada Negociação em Alta Frequência (HFT). As empresas de HFT surgiram e se apropriaram em larga escala do negócio de formação de mercado, no fornecimento de liquidez. Embora HFT tem crescido massivamente, ao longo dos últimos quatro anos, HFT perdeu rentabilidade significativamente, uma vez que mais empresas aderiram ao setor reduzindo as margens. Portanto, diante deste contexto, esta tese buscou apresentar uma breve revisão sobre a atividade de HFT, seguida de uma análise dos limites deste setor, bem como, das características do macroambiente do HFT. Para tanto, a tese realizou uma extensa revisão do histórico literário, documentos públicos qualitativos, tais como, jornais, atas de reunião e relatórios oficiais. A tese empregou um ferramental de análise, Barreiras de Entrada e Mobilidade (Porter, 1980); Modelos de Evolução Setorial (McGahan, 2004); Estrutura do Setor de Informação Intensiva (Sampler, 1998), para analisar os limites do setor de HFT. Adicionalmente, empregou as ferramentas de análise, Modelos de Evolução Setorial (McGahan, 2004) e PESTEL (JOHNSON, SCHOLES, and WHITTINGTON, 2011), para analisar o setor e o contexto que envolve o negócio de HFT. A análise concluiu que as empresas que empregam HFT para atuar e competir no mercado acionário, compoem um setor independente.
Resumo:
Objective The aim of this study was to compare intrapulpal temperature increases produced by a high-speed high-torque (speed-increasing) handpiece, a high-speed low-torque handpiece (air-turbine) and an Er: YAG (Erbium: Yttrium-Aluminum-Garnet) laser. Subject and methods Thirty bovine incisors were reduced to a dentine thickness of 2.0 mm. Class V preparations were prepared to a depth of 1.5 mm, measured with a caliper or by a mark on the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (C). Analysis was performed on the following groups (n = 10) treated with: G1, low-torque handpiece; G2, high-torque handpiece; and G3, Er: YAG laser (2.94 mu m at 250 mJ/4 Hz), all with water cooling. The temperature increases were recorded with a computer linked to the thermocouples. Results The data were submitted to ANOVA and Tukey statistical test. The average temperature rises were: 1.92 +/- 0.80 degrees C for G1, 1.34 +/- 0.86 degrees C for G2, and 0.75 +/- 0.39 degrees C for G3. There were significant statistical differences among the groups (p = 0.095). All the groups tested did not have a change of temperature that exceeds the threshold of 5.5 degrees C. Conclusion Temperature response to the low and high torque handpieces seemed to be similar, however the Er: YAG laser generated a lower temperature rise.