955 resultados para Cyclic voltammetry


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A wound-type cell with a polyaniline (PAn) positive electrode, a LiClO4-propylene carbonate (PC) electrolyte, and a lithium foil negative electrode has been constructed. The two electrodes are separated by a polypropylene separator. The PAn is deposited on carbon felt from a HClO4 solution containing aniline by galvanostatic or potentiostatic electrolysis. Using cyclic voltammetry charge/discharge cycles and charge/retention tests, the following results have been obtained: (i) reversibility of the charge/discharge reaction of the PAn electrode is very good; (ii) more than 50 charge/discharge cycles at 80% charge/discharge efficiency and 260 W h kg-1 discharge energy density can be achieved at 50 mA between 2 and 4 V; (iii) the open-circuit voltage and the capacity retention of the battery after storage at open-circuit for 60 days are 3.4 V and 33%, respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The electrochemical reduction of yttrium ion on a molybdenum electrode in a LiCl-KCl-NaCl eutectic melt at 723 K was found to be almost reversible and to proceed by a one-step three electron reaction. The diffusion coefficient D of the Y(III) ion was measured to be (3.3 +/- 0.4) x 10(-6) cm2 s-1 by cyclic voltammetry, (5.0 +/- 0.9) x 10(-6) cm2 s-1 by the rotating disk electrode method, and (7.1 +/- 0.7) x 10(-6) cm2 s-1 by chronopotentiometry. The D values obtained by the latter two methods are in fairly good agreement with each other. The rather low D value obtained by cyclic voltammetry might be attributed to the fact that yttrium metal can dissolve slightly in the chloride melt. The standard potential of Y(III)/Y(0) couple was determined to be (-3.174 +/- 0.006) V (vs. Cl2/Cl-) by open-circuit potentiometry, (-3.15 +/- 0.02) V (vs. Cl2/Cl-) by the rotating disk electrode method and (-3.16 +/- 0.02) V (vs. Cl2/Cl) by chronopotentiometry. These three values are in good agreement with each other. Several types of Ni-Y intermetallic compounds were found to be formed on a nickel electrode.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Electrochemical stability of poly(3-methylthiophene) (PMT) thin film modified glassy carbon electrodes was investigated experimentally with successive cyclic voltammetry(CV) The effects of electrolyte solutions on the stability were studied. In the presence of small hydrated anions (less-than-or-equal-to 3.5nm) in the solution, the electroactivity of PMT films decreased with the characteristics of second order kinetics. In a solution with large hydrated anions (greater-than-or-equal-to 4 nm), PMT films have good stability. PMT/GO electrode can electrocatalyse the oxidation of Br- and Cl- anions, and loses its electroactivity rapidly. X-ray photoelectron spectra (XPS) have demonstrated that chlorine has bonded covalently onto the PMT structure after OV cycles in NaCl solutions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The transfer of H+, Li+, Na+, Zn2+, Mg2+ and Cu2+ facilitated by ionophore ETH 129 (N, N, N', N'-tetracyolohexyl-3-oxapentanediamide) across water/nitrobenzene interface has been studied by the cyclic voltammetry. The mechanism of the transfer process has been discussed. The diffusion coefficients and the stability constants of the complexes formed in the nitrobenzene phase have been determined.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel Eastman-AQ/Ni(II) chemically modified electrode (CME) produced by "double coating step" deposition of a poly(ester sulphonic acid) polymer film and Ni2+-containing crystalline species onto glassy carbon instead of a metallic nickel electrode exhibited stable electrocatalytic oxidation of numerous alpha-hydrogen compounds including carbohydrates, amines and amino acids. In cyclic voltammetry, the electrocatalysis appeared with an irreversible anodic wave at +0.55 V (vs. Ag/AgCl). The CME was adapted for constant-potential amperometric detection of these compounds in flow injection analysis. Using the CME, the linear response concentration range was between 1.0 x 10(-5) and 5.0 x 10(-2) mol/l and the detection limit was 5.0 x 10(-6) mol/l for glucose. The stability of the CME was adequate for routine quantitative application.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Transfer behaviors across the water/nitrobenzene interface were studied for five choline derivatives by chronopotentiometry with linear current scanning, cyclic voltammetry and differential pulse voltammetry. The irreversible hydrolysis reactions coupled to the phase transfer of ions across the water/nitrobenzene interface were observed. The Gibbs energies of the transfer of choline derivatives show the effects of an additive constitution on hydrophobic property of the medicine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A microcarbon array electrode was modified by the placement of a Nafion film containing cobalt tetramethylpyridyl phorphyrin on its surface. This electrode was applied to the analysis of solution glucose when it was further modified by the immobilization of glucose oxidase on the outermost surface of the Nafion by the cross-linking of serum albumin with glutaraldehyde. The concomitant decrease in the concentration of oxygen, as it was consumed in the enzymatic reaction of glucose with glucose oxidase, was determined by either cyclic voltammetry or a double potential step method at the porphyrin-Nafion catalytic electrode. Glucose could be determined in the range of 0.01-4 mM rapidly, without interference from substances such as ascorbate or other saccharides.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The electrocatalytic oxidation of hydrazine (N2H4) on a glassy carbon electrode (GC) modified by monolayer and polymer films of cobalt protoporphyrin dimethyl ester (CoPP) has been studied. Both the monolayer and polymer films of CoPP are very active to the anodic oxidation of N2H4. The activity of CoPP for the anodic oxidation of N2H4 is dependent on the pH of the solution, and the thickness of polymerized CoPP film. The oxidation kinetics were examined by methods of cyclic voltammetry, rotating disc electrodes and steady-state polarization measurement.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A wall-jet cell incorporating a carbon fibre array ring/glassy-carbon disk electrode has been constructed, and characterized by the cyclic voltammetry and flow-injection techniques. The ring (composed of several microdisks) and glassy-carbon disk electrode, can be used separately for different purposes, e.g., detection in solution without a supporting electrolyte, collection/shielding detection with dual-electrode and voltammetric/amperometric detection with series dual-electrode. The electrode shows better collection and shielding effects than usual ring-disk electrode in quiescent solution and the series dual-electrode in a thin-layer flow-through cell. The detection limit at the ring electrode is comparable with that at a conventional-size electrode, and has been used in the mobile phase without a supporting electrolyte, proving to be a promising detector for normal-phase liquid chromatography.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The potential windows of the system water/pure solvent (W/P) and water/solvent mixtures(W/S) have been investigated by cyclic voltammetry with solvents whose dielectric constants lie between 5.87 and 34.82. In the presence of LiCI in the aqueous phase and tetrabutytammoniumtetraphenylborate(TBATPB) in the organic phase, the systems water/allyl iso-thiocyanate (W/AIT) and water/nitrobensene (W/NB) show a same wide epotential window. thermodynamic parameters of ion transfer W/AIT interface were determined. In systems of W/P and V/S the influence solvent effect on the standard gibbs energies of transfer of was discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Electrochemical transfer behavier of the V~vMo_(11)-V_5~vMo_7 heteropolyanions at the water/nitrobenzene interface has been investigated by using cyclic voltammetry. The effect of the solution acidity on the transfer behavior and the stable pH range of heteropolyanions were observed. Mixed melybdovanadate anions are more stable than 12-molybdophosphoric acid, however, the stability of the former decreases with increasing number of vanadium atoms. The main transfer species within the "potential window" has t...

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The surface structure of glassy carbon electrode subjected to "galvanostat" pretreat- ment and its electrocatalytic behaviour in the presence of ascorbic acid, catechol and hydroquinone were studied by means of cyclic voltammetry, chronoamperometry, chronocoulometry and scanning electron microscopy. The electrocatalytic mechanism was discussed, which was due to the adsorption and the catalysis of functional groups at the electrode surface. Three separated peaks from the mixture of catecnol, hydroq...

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A monolayer of 1:12 phosphomolybdic anion (PMo_(12)) was modified electrochemically on a glassy carbon electrode and its electrochemical behavior was studied with cyclic voltammetry (CV). It is shown that PMo_(12) film is adsoibed strongly on the surface of glassy carbon electrodes, H~+ ions in the solution plays an important role in the electrochemical processes of PMo_(12) film modified electrodes, whereas other anions, such as Cl~-, NO_3~-, SO_4~(2-), ClO_4~- and PO_4~(3-) etc., do not take par...

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It has been firstly found by means of cyclic voltammetry (CV) and chronopotentiometry with linear current-scanning (CLC)that 12-silicotungstate anion (SiW_(12)O_(40)~(4-)) with high charge numbers, large molecular volume and symmetric structure can cross

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The chemical reactions coupled with the phase transfer of Co(Ⅱ) catalyzed by 2,2′ -bipyridine across the water/nitrobenzene interface have been observed by using cyclic voltammetry (CV). Coupled chemical reactions both in the organic phase or in the aqueus phase influence the CV behavior of successive complex phase transfer obviously and an irreversible phenomenon similar to that existed at the metal electrode/electrolyte solution interface was observed. For different complexes, the phase transfer mechanism...