818 resultados para Reliability assessments
Resumo:
This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m2 mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.
Resumo:
The aim of this study was to assess the validity and reliability of the Fonseca Anamnestic Index (IAF), used to assess the severity of temporomandibular disorders, applied to Brazilian women. We used a probabilistic sampling design. The participants were 700 women over 18 years of age, living in the city of Araraquara (SP). The IAF questionnaire was applied by telephone interviews. We conducted Confirmatory Factor Analysis (CFA) using Chi-Square Over Degrees of Freedom (χ2/df), Comparative Fit Index (CFI), Tucker-Lewis Index (TLI), and Root Mean Square Error of Approximation (RMSEA) as goodness of fit indices. We calculated the convergent validity, the average variance extracted (AVE) and the composite reliability (CR). Internal consistency was assessed by Cronbach's alpha coefficient (α).The factorial weights of questions 8 and 10 were below the adequate values. Thus, we refined the original model and these questions were excluded. The resulting factorial model showed appropriate goodness of fit to the sample (χ2/df = 3.319, CFI = 0.978, TLI = 0.967, RMSEA = 0.058). The convergent validity (AVE = 0.513, CR = 0.878) and internal consistency (α = 0.745) were adequate. The reduced IAF version showed adequate validity and reliability in a sample of Brazilian women.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Nonalcoholic fatty liver disease (NAFLD) is a disorder associated with excessive fat accumulation, mainly in the intra-abdominal region. A simple technique to estimate abdominal fat in this region could be useful to assess the presence of NAFLD, in obese subjects who are more vulnerable to this disease. The aim of this cross-sectional study was to verify the reliability of waist circumference and body composition variables to identify the occurrence of NAFLD in obese children and adolescents.Methods: Sample was composed of 145 subjects, aged 11 to 17 years. Assessments of waist circumference (WC), trunk fat mass (TFM) and fat mass (FM) by dual-energy X-ray absorptiometry (DXA) and ultrasound for diagnosis of NAFLD and intra-abdominal adipose tissue (IAAT) were used. Correlation between variables was made by Spearman's coefficients; ROC curve parameters (sensitivity, specificity, area under curve) were used to assess the reliability of body composition variables to assess the presence of NAFLD. Statistical significance was set at 5%.Results: Significant correlations were observed between NAFLD and WC (p = 0.001), TFM (p = 0.002) and IAAT (p = 0.001). The higher values of area under the ROC curve were for WC (AUC = 0.720), TFM (AUC = 0.661) and IAAT (AUC = 0.741).Conclusions: Our findings indicated that TFM, IAAT and WC present high potential to identify NAFLD in obese children and adolescents.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Influence of abutment-to-fixture design on reliability and failure mode of all-ceramic crown systems
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To evaluate and compare the reliability of implant-supported single crowns cemented onto abutments retained with coated (C) or noncoated (NC) screws and onto platform-switched abutments with coated screws. Materials and Methods: Fifty-four implants (DT Implant 4-mm Standard Platform, Intra-Lock International) were divided into three groups (n = 18 each) as follows: matching-platform abutments secured with noncoated abutment screws (MNC); matching-platform abutments tightened with coated abutment screws (MC); and switched-platform abutments secured with coated abutment screws (SC). Screws were characterized by scanning electron microscopy and x-ray photoelectron spectroscopy (XPS). The specimens were subjected to step-stress accelerated life testing. Use-level probability Weibull curves and reliability for 100,000 cycles at 200 N and 300 N (90% two-sided confidence intervals) were calculated. Polarized light and scanning electron microscopes were used for fractographic analysis. Results: Scanning electron microscopy revealed differences in surface texture; noncoated screws presented the typical machining grooves texture, whereas coated screws presented a plastically deformed surface layer. XPS revealed the same base components for both screws, with the exception of higher degrees of silicon in the SiO2 form for the coated samples. For 100,000 cycles at 300 N, reliability values were 0.06 (0.01 to 0.16), 0.25 (0.09 to 0.45), and 0.25 (0.08 to 0.45), for MNC, MC, and SC, respectively. The most common failure mechanism for MNC was fracture of the abutment screw, followed by bending, or its fracture, along with fracture of the abutment or implant. Coated abutment screws most commonly fractured along with the abutment, irrespective of abutment type. Conclusion: Reliability was higher for both groups with the coated screw than with the uncoated screw. Failure modes differed between coated and uncoated groups.
Resumo:
Objectives: To investigate the reliability of regional three-dimensional registration and superimposition methods for assessment of temporomandibular joint condylar morphology across subjects and longitudinally.Methods: The sample consisted of cone beam CT scans of 36 patients. The across-subject comparisons included 12 controls, mean age 41.3 +/- 12.0 years, and 12 patients with temporomandibular joint osteoarthritis, mean age 41.3 +/- 14.7 years. The individual longitudinal assessments included 12 patients with temporomandibular joint osteoarthritis, mean age 37.8 +/- 16.7 years, followed up at pre-operative jaw surgery, immediately after and one-year post-operative. Surface models of all condyles were constructed from the cone beam CT scans. Two previously calibrated observers independently performed all registration methods. A landmark-based approach was used for the registration of across-subject condylar models, and temporomandibular joint osteoarthritis vs control group differences were computed with shape analysis. A voxel-based approach was used for registration of longitudinal scans calculated x, y, z degrees of freedom for translation and rotation. Two-way random intraclass correlation coefficients tested the interobserver reliability.Results: Statistically significant differences between the control group and the osteoarthritis group were consistently located on the lateral and medial poles for both observers. The interobserver differences were <= 0.2 mm. For individual longitudinal comparisons, the mean interobserver differences were <= 0.6 mm in translation errors and 1.2 degrees in rotation errors, with excellent reliability (intraclass correlation coefficient >0.75).Conclusions: Condylar registration for across-subjects and longitudinal assessments is reliable and can be used to quantify subtle bony differences in the three-dimensional condylar morphology.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study was aimed to analyze a procedure that makes the description of pictures in printed text from a book that promotes accessibility for blind people. In addition, the study was aimed to analyze the reformulations suggested by the judges and the index of agreement between researcher and judges. The descriptions were submitted to judges to evaluate the content of the material. The results were obtained through the analysis of two assessments: 1) agreement rate ‒ between the researcher and judges A and B, and between judge A and judge B and 2) analysis of the suggested reformulation. In quantitative terms, the results indicated that the material described achieved a high reliability. In qualitative terms, the reliability achieved represents the quality of the material offered, with well structured descriptions where writing meaning is equivalent to image information, fulfilling the purpose to present in printed text the elements represented in the pictures, effectively conveying their meaning.
Resumo:
This case study aims at identifying how a community of secondary school students selects web-based information and factors associated with the reliability of online reference sources during their collaborative inquiry (co-inquiry) projects. This study, conducted in a public secondary school in Brazil, focused on information literacy skills for collaborative open learning (colearning). The research is based on qualitative content analysis implemented on the online platform weSPOT. Although students are mindful of the importance of comparing different sources of information they seem not to be aware of reliability in online environments. Teacher's guidance is essential to support co-learners in developing competences, particularly related to critical thinking.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to investigate the reliability of visual and digital methods to assess marginal microleakage in vitro. Materials and Methods: Typical Class V preparations were made in bovine teeth and filled with composite resin. After dye penetration (0.5% basic fuchsin), teeth were sectioned and the 53 obtained fragments were assessed according to visual (stereomicroscope) and digital methods (Image Tool Software ® -ITS) (University of Texas Health Science Center-San Antonio Dental School, USA). Two calibrated examiners (A and B) evaluated dye penetration, by means of a stereomicroscope with ×20 magnification (scores), and by the ITS (millimeters). The intra- and inter-examiner agreement was estimated according to Kappa statistics (κ), and intraclass correlation coefficient (ρ). Results: In relation to the visual method, the intra-examiner agreement was almost perfect (κA = 0.87) and substantial (κB = 0.76), respectively to the examiner A and B. The inter-examiner agreement showed an almost perfect reliability (κ = 0.84). For the digital method, the intra-examiner agreement was almost perfect for both examiners and equal to ρ = 0.99, and so was the inter-examiner agreement value. Conclusion: Visual (stereomicroscope) and digital methods (ITS) showed high levels of intra- and inter-examiner reproducibility when marginal microleakage was assessed.