Reliability of Cardiorespiratory Parameters During Cycling Exercise Performed at the Severe Domain in Active Individuals


Autoria(s): Barbosa, Luis F.; Montagnana, Lucas; Denadai, Benedito S.; Greco, Camila C.
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

03/12/2014

03/12/2014

01/04/2014

Resumo

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Barbosa, LF, Montagnana, L, Denadai, BS, and Greco, CC. Reliability of cardiorespiratory parameters during cycling exercise performed at the severe domain in active individuals. J Strength Cond Res 28(4): 976-981, 2014-The purpose of this study was to determine the test-retest reliability of cardiorespiratory parameters during cycling exercise performed at severe domain in active individuals. Thirteen active males (24.5 +/- 4.5 years) performed the following tests: (a) an incremental test to determine V ̇o(2)max and the intensity associated with V ̇o(2)max (IV ̇o(2)max); and (b) 4 repetitions of square-wave transitions from rest to a power corresponding to 95%IV ̇o(2)max to determine the parameters of V ̇o(2) kinetics and time to exhaustion (Tlim). Participants performed only 2 transitions on any given day. The interval between the 2 experimental sessions was 48-72 hours. The intraclass correlation coefficient (ICC) and typical error as the coefficient of variation were used to assess reliability. Although the 2 measures of Tlim were moderately related (ICC = 0.78; p < 0.01), Tlim from the second session (545.2 +/- 103.1 seconds) was significantly higher than that of the first (492.5 +/- 100.9 seconds; p = 0.02). Moderate to high reliability (ICC = 0.76-0.93) for the amplitudes of the V ̇o(2) kinetics responses was found. Poor reliability, however, was found for time constants and time delays of the V ̇o(2) kinetics responses. Thus, in nonfamiliarized individuals, Tlim shows a relatively low within-subject coefficient of variation. However, the second score in a series of 2 Tlim tests may be significantly greater than the first. We have also demonstrated that the amplitudes of the V ̇o(2) response have significantly moderate to high reliability. The time-based parameters, however, present an important day-to-day intraindividual variation. Therefore, several transitions are recommended to monitoring changes in an individual over any time frame.

Formato

976-981

Identificador

http://dx.doi.org/10.1519/JSC.0b013e3182a1f408

Journal Of Strength And Conditioning Research. Philadelphia: Lippincott Williams & Wilkins, v. 28, n. 4, p. 976-981, 2014.

1064-8011

http://hdl.handle.net/11449/112803

10.1519/JSC.0b013e3182a1f408

WOS:000333557100015

Idioma(s)

eng

Publicador

Lippincott Williams & Wilkins

Relação

Journal of Strength and Conditioning Research

Direitos

closedAccess

Palavras-Chave #oxygen uptake kinetics #slow component #time to exhaustion
Tipo

info:eu-repo/semantics/article