816 resultados para Gold standard.


Relevância:

60.00% 60.00%

Publicador:

Resumo:

3D video-fluoroscopy is an accurate but cumbersome technique to estimate natural or prosthetic human joint kinematics. This dissertation proposes innovative methodologies to improve the 3D fluoroscopic analysis reliability and usability. Being based on direct radiographic imaging of the joint, and avoiding soft tissue artefact that limits the accuracy of skin marker based techniques, the fluoroscopic analysis has a potential accuracy of the order of mm/deg or better. It can provide fundamental informations for clinical and methodological applications, but, notwithstanding the number of methodological protocols proposed in the literature, time consuming user interaction is exploited to obtain consistent results. The user-dependency prevented a reliable quantification of the actual accuracy and precision of the methods, and, consequently, slowed down the translation to the clinical practice. The objective of the present work was to speed up this process introducing methodological improvements in the analysis. In the thesis, the fluoroscopic analysis was characterized in depth, in order to evaluate its pros and cons, and to provide reliable solutions to overcome its limitations. To this aim, an analytical approach was followed. The major sources of error were isolated with in-silico preliminary studies as: (a) geometric distortion and calibration errors, (b) 2D images and 3D models resolutions, (c) incorrect contour extraction, (d) bone model symmetries, (e) optimization algorithm limitations, (f) user errors. The effect of each criticality was quantified, and verified with an in-vivo preliminary study on the elbow joint. The dominant source of error was identified in the limited extent of the convergence domain for the local optimization algorithms, which forced the user to manually specify the starting pose for the estimating process. To solve this problem, two different approaches were followed: to increase the optimal pose convergence basin, the local approach used sequential alignments of the 6 degrees of freedom in order of sensitivity, or a geometrical feature-based estimation of the initial conditions for the optimization; the global approach used an unsupervised memetic algorithm to optimally explore the search domain. The performances of the technique were evaluated with a series of in-silico studies and validated in-vitro with a phantom based comparison with a radiostereometric gold-standard. The accuracy of the method is joint-dependent, and for the intact knee joint, the new unsupervised algorithm guaranteed a maximum error lower than 0.5 mm for in-plane translations, 10 mm for out-of-plane translation, and of 3 deg for rotations in a mono-planar setup; and lower than 0.5 mm for translations and 1 deg for rotations in a bi-planar setups. The bi-planar setup is best suited when accurate results are needed, such as for methodological research studies. The mono-planar analysis may be enough for clinical application when the analysis time and cost may be an issue. A further reduction of the user interaction was obtained for prosthetic joints kinematics. A mixed region-growing and level-set segmentation method was proposed and halved the analysis time, delegating the computational burden to the machine. In-silico and in-vivo studies demonstrated that the reliability of the new semiautomatic method was comparable to a user defined manual gold-standard. The improved fluoroscopic analysis was finally applied to a first in-vivo methodological study on the foot kinematics. Preliminary evaluations showed that the presented methodology represents a feasible gold-standard for the validation of skin marker based foot kinematics protocols.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction – Although imatinib (IM) is a recognized gold standard in chronic myeloid leukemia (CML) therapy, resistance has emerged in a significant proportion of patients. Aim – The aim of this study was: (1) to investigate the role of genetic variants in genes encoding for IM transporters, as candidate of IM responsiveness and (2) to test the influence of miRNAs on IM response, focusing on efflux transporters. Methods – As a first step, a panel of polymorphisms (SNPs) was genotyped in a subgroup population of 189 patients enrolled in the Tyrosine Kinase Inhibitor Optimization and Selectivity (TOPS) trial. The association with cytogenetic response and molecular response (MR) was assessed for each SNP. As a second step, an in vitro IM-resistant model (K-562 CML cell line) was established. miRNAs profiles were analyzed using Taqman arrays and in silico search was performed for miRNAs deregulated after IM treatment. mRNA and protein expression were quantified using TaqMan realtime PCR and Western blotting, respectively. Results – (1) Among Caucasian patients, ABCB1 rs60023214 significantly correlated with complete MR (P = 0.005). Concerning SNPs combination in IM uptake transporters, the associations with treatment outcomes were statistically significant for both major and complete MR (P = 0.005 and P = 0.01, respectively). (2) ABCB1 protein was not expressed under any conditions of treatment, differently from ABCG2. Two deregulated miRNAs, namely miR-212 and miR-328, were identified to be inversely correlated with ABCG2 (r2= 0.57; p=0.03 and r2=0.47; p=0.06, respectively). Experiments of loss and gain of function confirmed the functional influence of these miRNAs on ABCG2. Conclusion – The multiple candidate gene approach identified single and combination of SNPs that can be proposed as predictor of IM response. The in vitro study suggested that IM resistance could be mediated by miRNA-dependent mechanism. Further studies are needed to validate these preliminary findings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction Lower pole kidney stones represent at time a challenge for the urologist. The gold standard treatment for intrarenal stones <2 cm is Extracorporeal Shock Wave Lithotripsy (ESWL) while for those >2 cm is Percutaneous Nephrolithotomy (PCNL). The success rate of ESWL, however, decreases when it is employed for lower pole stones, and this is particularly true in the presence of narrow calices or acute infundibular angles. Studies have proved that ureteroscopy (URS) is an efficacious alternative to ESWL for lower pole stones <2 cm, but this is not reflected by either the European or the American guidelines. The aim of this study is to present the results of a large series of flexible ureteroscopies and PCNLs for lower pole kidney stones from high-volume centers, in order to provide more evidences on the potential indications of the flexible ureteroscopy for the treatment of kidney stones. Materials and Methods A database was created and the participating centres retrospectively entered their data relating to the percutaneous and flexible ureteroscopic management of lower pole kidney stones. Patients included were treated between January 2005 and January 2010. Variables analyzed included case load number, preoperative and postoperative imaging, stone burden, anaesthesia (general vs. spinal), type of lithotripter, access location and size, access dilation type, ureteral access sheath use, visual clarity, operative time, stone-free rate, complication rate, hospital stay, analgesic requirement and follow-up time. Stone-free rate was defined as absence of residual fragments or presence of a single fragment <2 mm in size at follow-up imaging. Primary end-point was to test the efficacy and safety of flexible URS for the treatment of lower pole stones; the same descriptive analysis was conducted for the PCNL approach, as considered the gold standard for the treatment of lower pole kidney stones. In this setting, no statistical analysis was conducted owing to the different selection criteria of the patients. Secondary end-point consisted in matching the results of stone-free rates, operative time and complications rate of flexible URS and PCNL in the subgroup of patients harbouring lower pole kidney stones between 1 and 2 cm in the higher diameter. Results A total 246 patients met the criteria for inclusion. There were 117 PCNLs (group 1) and 129 flexible URS (group 2). Ninety-six percent of cases were diagnosed by CT KUB scan. Mean stone burden was 175±160 and 50±62 mm2 for groups 1 and 2, respectively. General anaesthesia was induced in 100 % and 80% of groups 1 and 2, respectively. Pneumo-ultrasonic energy was used in 84% of cases in the PCNL group, and holmium laser in 95% of the cases in the flexible URS group. The mean operative time was 76.9±44 and 63±37 minutes for groups 1 and 2 respectively. There were 12 major complications (11%) in group 1 (mainly Grade II complications according to Clavidien classification) and no major complications in group 2. Mean hospital stay was 5.7 and 2.6 days for groups 1 and 2, respectively. Ninety-five percent of group 1 and 52% of group 2 required analgesia for a period longer than 24 hours. Intraoperative stone-free rate after a single treatment was 88.9% for group 1 and 79.1% for group 2. Overall, 6% of group 1 and 14.7% of group 2 required a second look procedure. At 3 months, stone-free rates were 90.6% and 92.2% for groups 1 and 2, respectively, as documented by follow-up CT KUB (22%) or combination of intra-venous pyelogram, regular KUB and/or kidney ultrasound (78%). In the subanalysis conducted comparing 82 vs 65 patients who underwent PCNL and flexible URS for lower pole stones between 1 and 2 cm, intreoperative stone-free rates were 88% vs 68% (p= 0.03), respectively; anyway, after an auxiliary procedure which was necessary in 6% of the cases in group 1 and 23% in group 2 (p=0.03), stone-free rates at 3 months were not statistically significant (91.5% vs 89.2%; p=0.6). Conversely, the patients undergoing PCNL maintained a higher risk of complications during the procedure, with 9 cases observed in this group versus 0 in the group of patients treated with URS (p=0.01) Conclusions These data highlight the value of flexible URS as a very effective and safe option for the treatment of kidney stones; thanks to the latest generation of flexible devices, this new technical approach seems to be a valid alternative in particular for the treatment of lower pole kidney stones less than 2 cm. In high-volume centres and in the hands of skilled surgeons, this technique can approach the stone-free rates achievable through PCNL in lower pole stones between 1 and 2 cm, with a very low risk of complications. Furthermore, the results confirm the high success rate and relatively low morbidity of modern PCNL for lower pole stones, with no difference detectable between the prone and supine position.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Compliance mit der immunsuppressiven Therapie spielt eine entscheidende Rolle für den langfristigen Erfolg einer Organtransplantation. Strategien zur Förderung der Compliance von organtransplantierten Patienten sind daher von besonderem Interesse. Im Rahmen der vorliegenden Arbeit wurde erstmals in Deutschland ein Konzept zur Pharmazeutischen Betreuung von organtransplantierten Patienten entworfen und mit wissenschaftlichen Methoden auf Durchführbarkeit und Nutzen geprüft. Zu diesem Zweck wurde eine prospektive, randomisierte Studie mit Kontrollgruppendesign initiiert, in die insgesamt 50 Patienten eingeschlossen wurden. Hauptziel der Studie war die Untersuchung des Einflusses einer 12-monatigen Pharmazeutischen Betreuung von lebertransplantierten Patienten auf die Compliance mit der immunsuppressiven Therapie. Zur Messung der Compliance wurden MEMS® (Medication Event Monitoring Systems) herangezogen, die momentan als Goldstandard in der Compliance-Messung angesehen werden. Weitere direkte und indirekte M

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die chronisch obstruktive Lungenerkrankung (engl. chronic obstructive pulmonary disease, COPD) ist ein Überbegriff für Erkrankungen, die zu Husten, Auswurf und Dyspnoe (Atemnot) in Ruhe oder Belastung führen - zu diesen werden die chronische Bronchitis und das Lungenemphysem gezählt. Das Fortschreiten der COPD ist eng verknüpft mit der Zunahme des Volumens der Wände kleiner Luftwege (Bronchien). Die hochauflösende Computertomographie (CT) gilt bei der Untersuchung der Morphologie der Lunge als Goldstandard (beste und zuverlässigste Methode in der Diagnostik). Möchte man Bronchien, eine in Annäherung tubuläre Struktur, in CT-Bildern vermessen, so stellt die geringe Größe der Bronchien im Vergleich zum Auflösungsvermögen eines klinischen Computertomographen ein großes Problem dar. In dieser Arbeit wird gezeigt wie aus konventionellen Röntgenaufnahmen CT-Bilder berechnet werden, wo die mathematischen und physikalischen Fehlerquellen im Bildentstehungsprozess liegen und wie man ein CT-System mittels Interpretation als lineares verschiebungsinvariantes System (engl. linear shift invariant systems, LSI System) mathematisch greifbar macht. Basierend auf der linearen Systemtheorie werden Möglichkeiten zur Beschreibung des Auflösungsvermögens bildgebender Verfahren hergeleitet. Es wird gezeigt wie man den Tracheobronchialbaum aus einem CT-Datensatz stabil segmentiert und mittels eines topologieerhaltenden 3-dimensionalen Skelettierungsalgorithmus in eine Skelettdarstellung und anschließend in einen kreisfreien Graphen überführt. Basierend auf der linearen System Theorie wird eine neue, vielversprechende, integral-basierte Methodik (IBM) zum Vermessen kleiner Strukturen in CT-Bildern vorgestellt. Zum Validieren der IBM-Resultate wurden verschiedene Messungen an einem Phantom, bestehend aus 10 unterschiedlichen Silikon Schläuchen, durchgeführt. Mit Hilfe der Skelett- und Graphendarstellung ist ein Vermessen des kompletten segmentierten Tracheobronchialbaums im 3-dimensionalen Raum möglich. Für 8 zweifach gescannte Schweine konnte eine gute Reproduzierbarkeit der IBM-Resultate nachgewiesen werden. In einer weiteren, mit IBM durchgeführten Studie konnte gezeigt werden, dass die durchschnittliche prozentuale Bronchialwandstärke in CT-Datensätzen von 16 Rauchern signifikant höher ist, als in Datensätzen von 15 Nichtrauchern. IBM läßt sich möglicherweise auch für Wanddickenbestimmungen bei Problemstellungen aus anderen Arbeitsgebieten benutzen - kann zumindest als Ideengeber dienen. Ein Artikel mit der Beschreibung der entwickelten Methodik und der damit erzielten Studienergebnisse wurde zur Publikation im Journal IEEE Transactions on Medical Imaging angenommen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Poiché la diagnosi differenziale degli episodi parossistici notturni è affidata alla VEPSG, tenendo conto dei limiti di tale metodica, il progetto attuale ha lo scopo di definire la resa diagnostica di strumenti alternativi alla VEPSG: anamnesi, home-made video ed EEG intercritico. Sono stati reclutati consecutivamente 13 pazienti, afferiti al nostro Dipartimento per episodi parossistici notturni. Ciascun paziente è stato sottoposto ad un protocollo diagnostico standardizzato. A 5 Medici Esperti in Epilessia e Medicina del Sonno è stato chiesto di formulare un orientamento diagnostico sulla base di anamnesi, EEG intercritico, home-made video e VEPSG. Attraverso l’elaborazione degli orientamenti diagnostici è stata calcolata la resa diagnostica delle procedure esaminate, a confronto con la VEPSG, attraverso il concetto di “accuratezza diagnostica”. Per 6 pazienti è stato possibile porre una diagnosi di Epilessia Frontale Notturna, per 2 di parasonnia, in 5 la diagnosi è rimasta dubbia. L’accuratezza diagnostica di ciascuna procedura è risultata moderata, con lievi differenze tra le diverse procedure (61.5% anamnesi; 66% home-made video; 69,2 % EEG intercritico). E’ essenziale migliorare ulteriormente l’accuratezza diagnostica di anamnesi, EEG intercritico ed home-made video, che possono risultare cruciali nei casi in cui la diagnosi non è certa o quando la VEPSG non è disponibile.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Until today, autogenic bone grafts from various donor regions represent the gold standard in the field of bone reconstruction, providing both osteoinductive and osteoconductive characteristics. However, due to low availability and a disequilibrium between supply and demand, the risk of disease transfer and morbidity, usually associated with autogeneic bone grafts, the development of biomimic materials with structural and chemical properties similar to those of natural bone have been extensively studied. So far,rnonly a few synthetic materials, so far, have met these criteria, displaying properties that allow an optimal bone reconstitution. Biosilica is formed enzymatically under physiological-relevant conditions (temperature and pH) via silicatein (silica protein), an enzyme that was isolated from siliceous sponges, cloned, and prepared in a recombinant way, retaining its catalytic activity. It is biocompatible, has some unique mechanical characteristics, and comprises significant osteoinductive activity.rnTo explore the application of biosilica in the fields of regenerative medicine,rnsilicatein was encapsulated, together with its substrate sodium metasilicate, into poly(D,L-lactide)/polyvinylpyrrolidone(PVP)-based microspheres, using w/o/wrnmethodology with solvent casting and termed Poly(D,L-lactide)-silicatein silicacontaining-microspheres [PLASSM]. Both silicatein encapsulation efficiency (40%) and catalytic activity retention upon polymer encapsulation were enhanced by addition of an essential pre-emulsifying step using PVP. Furthermore, the metabolic stability, cytoxicity as well as the kinetics of silicatein release from the PLASSM were studied under biomimetic conditions, using simulated body fluid. As a solid support for PLASSM, a polyvinylpyrrolidone/starch/Na2HPO4-based matrix (termed plastic-like filler matrix containing silicic acid [PMSA]) was developed and its chemical and physical properties determined. Moreover, due to the non-toxicity and bioinactivity of the PMSA, it is suggested that PMSA acts as osteoconductive material. Both components, PLASSM and PMSA, when added together, form arnbifunctional 2-component implant material, that is (i)non-toxic(biocompatible), (ii)moldable, (iii) self-hardening at a controlled and clinically suitable rate to allows a tight insertion into any bone defect (iv) biodegradable, (v)forms a porous material upon exposure to body biomimetic conditions, and (vi)displays both osteoinductive (silicatein)and osteoconductive (PMSA) properties.rnPreliminary in vivo experiments were carried out with rabbit femurs, by creatingrnartificial bone defects that were subsequently treated with the bifunctional 2-component implant material. After 9 weeks of implantation, both computed tomography (CT) and morphological analyses showed complete resorption of the implanted material, concurrent with complete bone regeneration. The given data can be considered as a significant contribution to the successful introduction of biosilica-based implants into the field of bone substitution surgery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Im Rahmen der vorliegenden Arbeit wurden Eignung und Nutzen des „Objective therapy Compliance Measurement“ (OtCMTM)-Systems, einer innovativen Weiterentwicklung im Bereich der elektronischen Compliance-Messung, untersucht. Unter experimentellen Bedingungen wurden Funktionalität und Verlässlichkeit der elektronischen OtCMTM-Blisterpackungen überprüft, um deren Eignung für den klinischen Einsatz zu zeigen. Funktionalität (≥90% lesbare Blister), Richtigkeit (≤2% Fehler) und Robustheit waren bei den OtCMTM-Blistern der Version 3 gegeben, nachdem die Fehler der Versionen 1 und 2 in Zusammenarbeit mit dem Hersteller TCG identifiziert und eliminiert worden waren. Der als Alternative zu den elektronischen Blistern für die Verpackung von klinischen Prüfmustern entwickelte OtCMTM e-Dispenser wurde bezüglich Funktionalität und Anwenderfreundlichkeit in einer Pilotstudie untersucht. Dabei wurde ein Optimierungsbedarf festgestellt. In einer klinischen Studie wurde das OtCMTM-System mit dem als „Goldstandard geltenden MEMS® verglichen. Vergleichskriterien waren Datenqualität, Akzeptanz und Anwenderfreundlichkeit, Zeitaufwand bei der Bereitstellung der Medikation und Datenauswertung, sowie Validität. Insgesamt 40 Patienten, die mit Rekawan® retard 600mg behandelt wurden, nahmen an der offenen, randomisierten, prospektiven Studie teil. Das OtCMTM-System zeigte sich bezüglich Validität, Akzeptanz und Anwenderfreundlichkeit mit MEMS® vergleichbar. Eine erwartete Zeitersparnis wurde mit dem OtCMTM-System gegenüber MEMS® nicht erreicht. Vorteile des OtCMTM-Systems sind eine höhere Datenqualität und die Möglichkeit zum Einsatz in der Telemedizin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La risonanza magnetica cardiaca è una tecnica di imaging non invasiva, in quanto non necessita l’uso di radiazioni ionizzanti, caratterizzata da un’elevata risoluzione spaziale e che permette acquisizioni in 4-D senza vincoli di orientazione. Grazie a queste peculiarità, la metodica della risonanza magnetica ha mostrato la sua superiorità nei confronti delle altre tecniche diagnostiche ed è riconosciuta come il gold standard per lo studio della fisiologia e fisiopatologia della pompa cardiaca. Nonostante la potenza di questi vantaggi, esistono ancora varie problematiche che, se superate, potrebbero probabilmente migliorare ulteriormente la qualità delle indagini diagnostiche. I software attualmente utilizzati nella pratica clinica per le misure del volume e della massa ventricolare richiedono un tracciamento manuale dei contorni dell’endocardio e dell’epicardio per ciascuna fetta, per ogni frame temporale del ciclo cardiaco. Analogamente avviene per il tracciamento dei contorni del tessuto non vitale. In questo modo l’analisi è spesso qualitativa. Di fatti, la necessità dell’intervento attivo dell’operatore rende questa procedura soggettiva e dipendente dall’esperienza, provocando un’elevata variabilità e difficile ripetibilità delle misure intra e inter operatore, oltre ad essere estremamente dispendiosa in termini di tempo, a causa dell’elevato numero di immagini da analizzare. La disponibilità di una tecnica affidabile per il tracciamento automatico dei contorni dell’endocardio e dell’epicardio consente di superare queste limitazioni ed aumentare l’accuratezza e la ripetibilità delle misure di interesse clinico, quali dimensione, massa e curve di volume ventricolari. Lo scopo di questa tesi è di sviluppare e validare una tecnica di segmentazione automatica che consenta l’identificazione e la quantificazione di cicatrici nel miocardio, a seguito di infarto cardiaco. Il lavoro è composto da due tappe principali. Inizialmente, è presentato un metodo innovativo che permette, in via totalmente automatica, di tracciare in modo accurato e rapido i contorni dell’endocardio e dell’epicardio nel corso dell’intero ciclo cardiaco. Successivamente, l’informazione sulla morfologia cardiaca ricavata nella prima fase è utilizzata per circoscrivere il miocardio e quantificare la transmuralità dell’infarto presente in pazienti ischemici.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hintergrund: Die Systembiopsie gilt als Goldstandard zum Nachweis eines Prostatakarzinoms, obwohl ein relevanter Anteil an Prostatakarzinomen nicht diagnostiziert wird. Wir wollten mit unserer Arbeit die Frage beantworten, ob mittels elastographisch gezielter Biopsien die Prostatakarzinom-Detektion im Vergleich zur Goldstandard-Systembiopsie verbessert werden kann. Material und Methode: 152 Patienten wurden in einer prospektiven Studie einer 12-fachen Prostata-Systembiopsie unterzogen. In Linksseitenlagerung wurde dabei aus jedem der vordefinierten 6 Prostatasegmente je 1 laterale und 1 mediale Stanze entnommen. Elastographisch suspekte Areale wurden zusätzlich gezielt biopsiert. Als statistisch signifikant wurde p<0,05 angenommen. Ergebnisse: Bei 62 der 152 Patienten (40,8%) wurde ein Prostatakarzinom diagnostiziert. Die Detektionsrate der Systembiopsie betrug 39,5% (60/152), die Detektionsrate der Elastographie 29,6% (45/152). Somit war die Systembiopsie der elastographisch gezielten Biopsie signifikant überlegen (p=0,039).Jedoch war die Wahrscheinlichkeit mit einer Prostatastanze ein Karzinomherd zu entdecken, für die elastographischen Biopsien 3,7-fach höher als für die Systembiopsien. Die Sensitivität der Elastographie betrug 72,6% und die Spezifität 66,6%. Der positive Vorhersagewert für die Elastographie war 60%, der negative Vorhersagewert 78%. Die Kombination von Systembiopsie und elastographisch gezielten Biopsien bot die höchste Detektionsrate. In der rechten Prostatahälfte (48%) verzeichneten wir doppelt so viele elastographisch falsch-positive Befunde wie in der linken Prostatahälfte (25%). Desweiteren fanden sich am häufigsten falsch-positive Befunde im Prostata-Apex (46%) und am seltensten in der Prostata-Basis (29%). Schlussfolgerung: In unserer Studie war die elastographisch gezielte Biopsie der Systembiopsie signifikant unterlegen (p=0,039). Die Kombination von Systembiopsie mit elastographisch gezielten Biopsien bot die höchste Detektionsrate und kann daher empfohlen werden. Die Auffälligkeiten in der Segment-bezogenen Auswertung und ein möglicher Einfluss der Patienten-Lagerung müssen durch weitere Studien überprüft werden.rn

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Il proposito principale di questo studio è valutare, attraverso un confronto tra tecnologia Nexfin e metodo invasivo, se l’attuazione di modelli fisiologici realizzata dal Monitor Nexfin, rende possibile un preciso e accurato monitoraggio dinamico della pressione arteriosa, garantendo in questo modo l’affidabilità della suddetta tecnologia in ambito clinico. È stato deciso di porre come termine di paragone il sistema invasivo in quanto rappresenta il gold standard per la rilevazione della pressione arteriosa. I capitoli sono stati disposti in modo da introdurre gradualmente il lettore all’interno del topic principale dell’elaborato, fornendo di volta in volta tutte le conoscenze essenziali per una comprensione ottimale degli argomenti trattati. Il primo capitolo fornisce inizialmente una breve visione d’insieme sull’apparato cardiocircolatorio, per poi concentrarsi sui fenomeni che concorrono alla definizione e alla caratterizzazione della pressione arteriosa. Il secondo capitolo presenta alcuni cenni storici sulle prime misurazioni di pressione effettuate, in seguito illustra i principali metodi di misurazione non invasivi, articolando il discorso anche attraverso l’analisi dei principali sfigmomanometri ad oggi disponibili. Il terzo capitolo guida il lettore attraverso la scoperta delle più recenti metodiche non invasive per la misurazione della pressione che consentono un monitoraggio dinamico, esponendo nel dettaglio i loro limiti e le loro peculiarità. Nella parte finale del capitolo si affronta anche l’evoluzione del “Volume Clamp Method” di Peñáz partendo dal progetto originale fino a giungere al notevole contributo di Wesseling e alla ricostruzione del segnale di pressione brachiale. Il quarto capitolo delinea brevemente le caratteristiche principali del metodo invasivo, ovvero il gold standard per quanto riguarda il monitoraggio della pressione sanguigna. Il quinto capitolo infine illustra in maniera completa le proprietà del Monitor Nexfin e analizza i risultati conseguiti, confrontando la tecnologia Nexfin con il sistema invasivo, durante lo studio condotto presso l’Ospedale Maurizio Bufalini dell’Azienda USL della Romagna – Sede operativa di Cesena. Lo studio è presentato seguendo una impostazione scientifica.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Opportunistic diseases caused by Human Immunodeficiency Virus (HIV) and Hepatitis B Virus (HBV) is an omnipresent global challenge. In order to manage these epidemics, we need to have low cost and easily deployable platforms at the point-of-care in high congestions regions like airports and public transit systems. In this dissertation we present our findings in using Localized Surface Plasmon Resonance (LSPR)-based detection of pathogens and other clinically relevant applications using microfluidic platforms at the point-of-care setting in resource constrained environment. The work presented here adopts the novel technique of LSPR to multiplex a lab-on-a-chip device capable of quantitatively detecting various types of intact viruses and its various subtypes, based on the principle of a change in wavelength occurring when metal nano-particle surface is modified with a specific surface chemistry allowing the binding of a desired pathogen to a specific antibody. We demonstrate the ability to detect and quantify subtype A, B, C, D, E, G and panel HIV with a specificity of down to 100 copies/mL using both whole blood sample and HIV-patient blood sample discarded from clinics. These results were compared against the gold standard Reverse Transcriptase Polymerase Chain Reaction (RT-qPCR). This microfluidic device has a total evaluation time for the assays of about 70 minutes, where 60 minutes is needed for the capture and 10 minutes for data acquisition and processing. This LOC platform eliminates the need for any sample preparation before processing. This platform is highly multiplexable as the same surface chemistry can be adapted to capture and detect several other pathogens like dengue virus, E. coli, M. Tuberculosis, etc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Movement analysis carried out in laboratory settings is a powerful, but costly solution since it requires dedicated instrumentation, space and personnel. Recently, new technologies such as the magnetic and inertial measurement units (MIMU) are becoming widely accepted as tools for the assessment of human motion in clinical and research settings. They are relatively easy-to-use and potentially suitable for estimating gait kinematic features, including spatio-temporal parameters. The objective of this thesis regards the development and testing in clinical contexts of robust MIMUs based methods for assessing gait spatio-temporal parameters applicable across a number of different pathological gait patterns. First, considering the need of a solution the least obtrusive as possible, the validity of the single unit based approach was explored. A comparative evaluation of the performance of various methods reported in the literature for estimating gait temporal parameters using a single unit attached to the trunk first in normal gait and then in different pathological gait conditions was performed. Then, the second part of the research headed towards the development of new methods for estimating gait spatio-temporal parameters using shank worn MIMUs on different pathological subjects groups. In addition to the conventional gait parameters, new methods for estimating the changes of the direction of progression were explored. Finally, a new hardware solution and relevant methodology for estimating inter-feet distance during walking was proposed. Results of the technical validation of the proposed methods at different walking speeds and along different paths against a gold standard were reported and showed that the use of two MIMUs attached to the lower limbs associated with a robust method guarantee a much higher accuracy in determining gait spatio-temporal parameters. In conclusion, the proposed methods could be reliably applied to various abnormal gaits obtaining in some cases a comparable level of accuracy with respect to normal gait.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Herz-Kreislauf-Erkrankungen zählen weltweit zu den Hauptursachen, die zu frühzeitigem Tod führen. Pathophysiologisch liegt eine Gefäßwandverdickung durch Ablagerung arteriosklerotischer Plaques (Arteriosklerose) vor. Die molekulare Bildgebung mit den nuklearmedizinischen Verfahren SPECT und PET zielt darauf ab, minderperfundierte Myokardareale zu visualisieren, um den Krankheitsverlauf durch frühzeitige Therapie abschwächen zu können. Routinemäßig eingesetzt werden die SPECT-Perfusionstracer [99mTc]Sestamibi und [99mTc]Tetrofosmin. Zum Goldstandard für die Quantifizierung der Myokardperfusion werden allerdings die PET-Tracer [13N]NH3 und [15O]H2O, da eine absolute Bestimmung des Blutflusses in mL/min/g sowohl in der Ruhe als auch bei Belastung möglich ist. 2007 wurde [18F]Flurpiridaz als neuer Myokardtracer vorgestellt, dessen Bindung an den MC I sowohl in Ratten, Hasen, Primaten als auch in ersten klinischen Humanstudien eine selektive Myokardaufnahme zeigte. Um eine Verfügbarkeit des Radionuklids über einen Radionuklidgenerator gewährleisten zu können, sollten makrozyklische 68Ga-Myokard-Perfusionstracer auf Pyridaben-Basis synthetisiert und evaluiert werden. Die neue Tracer-Klasse setzte sich aus dem makrozyklischen Chelator, einem Linker und dem Insektizid Pyridaben als Targeting-Vektor zusammen. Struktur-Affinitätsbeziehungen konnten auf Grund von Variation des Linkers (Länge und Polarität), der Komplexladung (neutral und einfach positiv geladen), des Chelators (DOTA, NODAGA, DO2A) sowie durch einen Multivalenzansatz (Monomer und Dimer) aufgestellt werden. Insgesamt wurden 16 neue Verbindungen synthetisiert. Ihre 68Ga-Markierung wurde hinsichtlich pH-Wert, Temperatur, Vorläufermenge und Reaktionszeit optimiert. Die DOTA/NODAGA-Pyridaben-Derivate ließen sich mit niedrigen Substanzmengen (6 - 25 nmol) in 0,1 M HEPES-Puffer (pH 3,4) bei 95°C innerhalb 15 min mit Ausbeuten > 95 % markieren. Für die DO2A-basierenden Verbindungen bedurfte es einer mikrowellengestützen Markierung (300 W, 1 min, 150°C), um vergleichbare Ausbeuten zu erzielen. Die in vitro-Stabilitätstests aller Verbindungen erfolgten in EtOH, NaCl und humanem Serum. Es konnten keine Instabilitäten innerhalb 80 min bei 37°C festgestellt werden. Unter Verwendung der „shake flask“-Methode wurden die Lipophilien (log D = -1,90 – 1,91) anhand des Verteilungs-quotienten in Octanol/PBS-Puffer ermittelt. Die kalten Referenzsubstanzen wurden mit GaCl3 hergestellt und zur Bestimmung der IC50-Werte (34,1 µM – 1 µM) in vitro auf ihre Affinität zum MC I getestet. In vivo-Evaluierungen erfolgten mit den zwei potentesten Verbindungen [68Ga]VN160.MZ und [68Ga]VN167.MZ durch µ-PET-Aufnahmen (n=3) in gesunden Ratten über 60 min. Um die Organverteilung ermitteln zu können, wurden ex vivo-Biodistributionsstudien (n=3) vorgenommen. Sowohl die µ-PET-Untersuchungen als auch die Biodistributionsstudien zeigten, dass es bei [68Ga]VN167.MZ zwar zu einer Herzaufnahme kam, die jedoch eher perfusionsabhängig ist. Eine Retention des Tracers im Myokard konnte in geringem Umfang festgestellt werden.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die Fallzahlen von Prostata- und Brustkrebs nehmen aktuell die Spitzenplätze bei Krebserkrankungen weltweit ein. Eine schwerwiegende Folge dieser Erkrankung stellen Metastasierungen in das Knochengewebe dar, welche zu einer dramatischen Verschlechterung des Allgemeinzustandes und der Lebensqualität des Patienten führen. Die Symptome sind gekennzeichnet durch enorme Schmerzen in Kombination mit osteoblastischen und osteolytischen Knochenveränderungen, bis hin zu Frakturen und spinalen Kompressionssyndromen, sowie einer metabolischen Hypercalcaemie.rnBei der Diagnose und Therapie nehmen verschiedene Radiopharmaka eine Schlüsselrolle ein. Konjugate aus makrozyklischen Chelatoren und knochenaffinen Bisphosphonaten stellen ein geeignetes Mittel dar als so genannte Theranostika, die Diagnose und Therapie in einem Molekül vereinen. Hierbei konnten mit dem Generator basierenden PET-Nuklid 68Ga(III) und dem Therapienuklid 177Lu(III) erste Erfolge mit der Verbindung BPAMD am Patienten erzielt werden. Im Rahmen der vorliegenden Arbeit ist es gelungen, die pharmakologischen Eigenschaften der BPAMD-Leitstruktur weiter zu optimieren und neue Derivate erfolgreich zu synthetisieren. Diese zeichneten sich durch eine erhöhte Knochenaffinität und eines besseren ´target to background´ Verhältnisses aus. Im Zuge der Derivatisierung ist es außerdem gelungen, erfolgreich eine Substanz darzustellen, welche über eine gesteigerte Blutretention verfügt und die letztendlich die Bioverfügbarkeit des Tracers erhöhte. Verbindungen solchen Typs können zu einem besseren Tumor zu gesundem Knochen Verhältnis beitragen und eventuell einen höheren Therapieerfolg erzielen. Eines dieser neuen vielversprechenden Bisphosphonate, [68Ga]NO2APBP konnte innerhalb einer klinischen Phase 0 bzw. I sein großes Potential als Diagnostikum zur Erfassung von Skelettmetastasen unter Beweis stellen. Innerhalb einer Testreihe mit 12 Patienten wurde eine hohe diagnostische Übereinstimmung mit dem Goldstandard 18F-Fluorid erreicht. In ausgesuchten Metastasen konnte sogar eine höhere Tracer-Aufnahme erzielt werden.rnIn Zukunft können makrozyklische Bisphosphonate eine wichtige Rolle bei der palliativen Schmerztherapie von Knochenmetastasen einnehmen. rn