897 resultados para transparent electrode
Resumo:
A theoretical model for the steady-state response of anodic contactors that emit a plasma current Ii and collect electrons from a collisionless, unmagnetized plasma is presented. The use of a (kinetic) monoenergetic population for the attracted species, well known in passive probe theory, gives both accuracy and tractability to the theory. The monoenergetic population is proved to behave like an isentropic fluid with radial plus centripetal motion, allowing direct comparisons with ad hoc fluid models. Also, a modification of the original monoenergetic equations permits analysis of contactors operating in orbit-limited conditions. Besides that, the theory predicts that, only for plasma emissions above certain threshold current a presheath/double layer/core structure for the potential is formed (the core mode), while for emissions below that threshold, a plasma contactor behaves exactly as a positive-ion emitter with a presheath/sheath structure (the no-core mode). Ion emitters are studied as a particular case. Emphasis is placed on obtaining dimensionless charts and approximate asymptotic laws of the current-voltage characteristic.
Resumo:
Building-integrated Photovoltaics (BIPV) is one of the most promising technologies enabling buildings to generate on-site part of their electricity needs while performing architectural functionalities. A clear example of BIPV products consists of semi-transparent photovoltaic modules (STPV), designed to replace the conventional glazing solutions in building façades. Accordingly, the active building envelope is required to perform multiple requirements such as provide solar shading to avoid overheating, supply solar gains and thermal insulation to reduce heat loads and improve daylight utilization. To date, various studies into STPV systems have focused on their energy performance based on existing simulation programs, or on the modelling, normally validated by limited experimental data, of the STPV modules thermal behaviour. Taking into account that very limited experimental research has been conducted on the energy performance of STPV elements and that the characterization in real operation conditions is necessary to promote an energetically efficient integration of this technology in the building envelope, an outdoor testing facility has been designed, developed and built at the Solar Energy Institute of the Technical University of Madrid. In this work, the methodology used in the definition of the testing facility, its capability and limitations are presented and discussed.
Resumo:
A complete characterisation of PV modules for building integration is needed in order to know their influence on the building’s global energy balance. Specifically, certain characteristic parameters should be obtained for each different PV module suitable for building integrated photovoltaics (BIPV), some by direct or indirect measurements at the laboratory, and others by monitoring the element performance mounted in real operating conditions. In the case of transparent building envelopes it is particularly important to perform an optical and thermal characterization of the PV modules that would be integrated in them. This paper addresses the optical characterization of some commercial thin-film PV modules having different degrees of transparency, suitable for building integration in façades. The approach is based on the measurement of the spectral UV/Vis/NIR reflectance and transmittance of the different considered samples, both at normal incidence and as a function of the angle of incidence. With the obtained results, the total and zoned UV, visible and NIR transmission and reflection values are calculated, enabling the correct characterization of the PV modules integrated in façades and the subsequent evaluation of their impact over the electrical, thermal and lighting performance in a building.
Resumo:
In this paper, a methodology for the integral energy performance characterization (thermal, daylighting and electrical behavior) of semi-transparent photovoltaic modules (STPV) under real operation conditions is presented. An outdoor testing facility to analyze simultaneously thermal, luminous and electrical performance of the devices has been designed, constructed and validated. The system, composed of three independent measurement subsystems, has been operated in Madrid with four prototypes of a-Si STPV modules, each one corresponding to a specific degree of transparency. The extensive experimental campaign, continued for a whole year rotating the modules under test, has validated the reliability of the testing facility under varying environmental conditions. The thermal analyses show that both the solar protection and insulating properties of the laminated prototypes are lower than those achieved by a reference glazing whose characteristics are in accordance with the Spanish Technical Building Code. Daylighting analysis shows that STPV elements have an important lighting energy saving potential that could be exploited through their integration with strategies focused to reduce illuminance values in sunny conditions. Finally, the electrical tests show that the degree of transparency is not the most determining factor that affects the conversion efficiency.
Resumo:
Within the building energy saving strategies, BIPV (building integrated photovoltaic systems) present a promising potential based on the close relationship existing between these multifunctional systems and the overall building energy balance. Building integration of STPV (semi-transparent photovoltaic) elements affects deeply the building energy demand since it influences the heating, cooling and lighting loads as well as the local electricity generation. This work analyses over different window-to-wall ratios the overall energy performance of five STPV elements, each element having a specific degree of transparency, in order to assess the energy saving potential compared to a conventional solar control glass compliant with the local technical standard. The prior optical characterization, focused to measure the spectral properties of the elements, was experimentally undertaken. The obtained data were used to perform simulations based on a reference office building using a package of specific software tools (DesignBuilder, EnergyPlus, PVsyst, and COMFEN) to take proper account of the STPV peculiarities. To evaluate the global energy performance of the STPV elements a new Energy Balance Index was formulated. The results show that for intermediate and large façade openings the energy saving potential provided by the STPV solutions ranges between 18% and 59% compared to the reference glass.
Integral energy behaviour of photovoltaic semi-transparent glazing elements for building integration
Resumo:
La hipótesis general que esta tesis quiere demostrar es que la integración arquitectónica de sistemas fotovoltaicos semitransparentes (STPV) puede contribuir a mejorar la eficiencia energética de los edificios. Por lo tanto, la investigación se centra en el desarrollo de una metodología capaz de cuantificar la reducción de la demanda energética del edificio proporcionada por estas novedosas soluciones constructivas. Al mismo tiempo, los parámetros de diseño de las soluciones STPV se han analizado para establecer cuales presentan el mayor impacto sobre el balance energético global del edificio y por lo tanto tienen que ser cuidadosamente definidos a la hora de optimizar el comportamiento energético del mismo. A la luz de estos objetivos, la metodología de estudio se ha centrado en tres puntos principales: Caracterizar el comportamiento energético global de sistemas STPV en condiciones de operación realistas, similares a las que se darían en un sistema real; Caracterizar el comportamiento energético global de sistemas STPV en condiciones controladas, con el objetivo de estudiar la variación del comportamiento del los elementos en función de parámetro de diseño y operación; Evaluar el potencial de ahorro energético global de los sistemas STPV en comparación con soluciones acristaladas convencionales al variar de las condiciones de contorno constituidas por los parámetros de diseño (como el grado de transparencia), las características arquitectónicas (como el ratio entre superficie acristalada y superficie opaca en la fachada del edificio) y las condiciones climáticas (cubriendo en particular la climatología europea). En síntesis, este trabajo intenta contribuir a comprender la interacción que existe entre los sistemas STPV y el edificio, proporcionando tanto a los fabricantes de los componentes como a los profesionales de la construcción información valiosa sobre el potencial de ahorro energético asociado a estos nuevos sistemas constructivos. Asimismo el estudio define los parámetros de diseño adecuados para lograr soluciones eficientes tanto en proyectos nuevos como de rehabilitación. ABSTRACT The general hypothesis this work seeks to demonstrate is that the architectural integration of Semi-Transparent Photovoltaic (STPV) systems can contribute to improving the energy efficiency of buildings. Accordingly, the research has focused on developing a methodology able to quantify the building energy demand reduction provided by these novel constructive solutions. At the same time, the design parameters of the STPV solution have been analysed to establish which of them have the greatest impact on the global energy balance of the building, and therefore which have to be carefully defined in order to optimize the building operation. In the light of these goals, the study methodology has focused on three main points: To characterise the global energy behaviour of STPV systems in realistic operating conditions, similar to those in which a real system will operate; To characterise the global energy behaviour of STPV systems in controlled conditions in order to study how the performance varies depending on the design and operating parameters; To assess the global energy saving potential of STPV systems in comparison with conventional glazing solutions by varying the boundary conditions, including design parameters (such as the degree of transparency), architectural characteristics (such as the Window to Wall Ratio) and climatic conditions (covering the European climatic conditions). In summary, this work has sought to contribute to the understanding of the interaction between STPV systems and the building, providing both components manufacturers and construction technicians, valuable information on the energy savings potential of these new construction systems and defining the appropriate design parameters to achieve efficient solutions in both new and retrofitting projects.
Resumo:
Postprint
Resumo:
Funding: Work on this article has been partially funded by the European Commission FP7 Program (grant agreement 258583) as part of the DECIDE project. Sole responsibility lies with the authors; the European Commission is not responsible for any use that may be made of the information contained therein.
Resumo:
Funding: Work on this article has been partially funded by the European Commission FP7 Program (grant agreement 258583) as part of the DECIDE project. Sole responsibility lies with the authors; the European Commission is not responsible for any use that may be made of the information contained therein.
Resumo:
The performance of an amperometric biosensor, consisting of a subcutaneously implanted miniature (0.29 mm diameter, 5 × 10−4 cm2 mass transporting area), 90 s 10–90% rise/decay time glucose electrode, and an on-the-skin electrocardiogram Ag/AgCl electrode was tested in an unconstrained, naturally diabetic, brittle, type I, insulin-dependent chimpanzee. The chimpanzee was trained to wear on her wrist a small electronic package and to present her heel for capillary blood samples. In five sets of measurements, averaging 5 h each, 82 capillary blood samples were assayed, their concentrations ranging from 35 to 400 mg/dl. The current readings were translated to blood glucose concentration by assaying, at t = 1 h, one blood sample for each implanted sensor. The rms error in the correlation between the sensor-measured glucose concentration and that in capillary blood was 17.2%, 4.9% above the intrinsic 12.3% rms error of the Accu-Chek II reference, through which the illness of the chimpanzee was routinely managed. Linear regression analysis of the data points taken at t>1 h yielded the relationship (Accu-Chek) = 0.98 × (implanted sensor) + 4.2 mg/dl, r2 = 0.94. The capillary blood and the subcutaneous glucose concentrations were statistically indistinguishable when the rate of change was less than 1 mg/(dl⋅min). However, when the rate of decline exceeded 1.8 mg/(dl⋅min) after insulin injection, the subcutaneous glucose concentration was transiently higher.
Resumo:
The large potential of redox enzymes to carry out formation of high value organic compounds motivates the search for innovative strategies to regenerate the cofactors needed by their biocatalytic cycles. Here, we describe a bioreactor where the reducing power to the cycle is supplied directly to purified cytochrome CYP101 (P450cam; EC 1.14.15.1) through its natural redox partner (putidaredoxin) using an antimony-doped tin oxide working electrode. Required oxygen was produced at a Pt counter electrode by water electrolysis. A continuous catalytic cycle was sustained for more than 5 h and 2,600 enzyme turnovers. The maximum product formation rate was 36 nmol of 5-exo-hydroxycamphor/nmol of CYP101 per min.
Resumo:
Materials with high electrical conductivity and optical transparency are needed for future flat panel display, solar energy, and other opto-electronic technologies. InxCd1-xO films having a simple cubic microstructure have been grown on amorphous glass substrates by a straightforward chemical vapor deposition process. The x = 0.05 film conductivity of 17,000 S/cm, carrier mobility of 70 cm2/Vs, and visible region optical transparency window considerably exceed the corresponding parameters for commercial indium-tin oxide. Ab initio electronic structure calculations reveal small conduction electron effective masses, a dramatic shift of the CdO band gap with doping, and a conduction band hybridization gap caused by extensive Cd 5s + In 5s mixing.
Resumo:
We have investigated the influence of electrode material and crystallographic structure on electron transfer and biofilm formation of Geobacter sulfurreducens. Single-crystal gold - Au(110), Au(111), Au(210) - and platinum - Pt(100), Pt(110), Pt(111), Pt(210) - electrodes were tested and compared to graphite rods. G. sulfurreducens electrochemically interacts with all these materials with different attachment kinetics and final current production, although redox species involved in the electron transfer to the anode are virtually the same in all cases. Initial bacterial colonization was fastest on graphite up to the monolayer level, whereas gold electrodes led to higher final current densities. Crystal geometry showed to have an important influence, with Au(210) sustaining a current density of up to 1442 (± 101) μA cm- 2 at the steady state, over Au(111) with 961 (± 94) μA cm- 2 and Au(110) with 944 (± 89) μA cm- 2. On the other hand, the platinum electrodes displayed the lowest performances, including Pt(210). Our results indicate that both crystal geometry and electrode material are key parameters for the efficient interaction of bacteria with the substrate and should be considered for the design of novel materials and microbial devices to optimize energy production.
Resumo:
A novel method is reported, whereby screen-printed electrodes (SPELs) are combined with dispersive liquid–liquid microextraction. In-situ ionic liquid (IL) formation was used as an extractant phase in the microextraction technique and proved to be a simple, fast and inexpensive analytical method. This approach uses miniaturized systems both in sample preparation and in the detection stage, helping to develop environmentally friendly analytical methods and portable devices to enable rapid and onsite measurement. The microextraction method is based on a simple metathesis reaction, in which a water-immiscible IL (1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [Hmim][NTf2]) is formed from a water-miscible IL (1-hexyl-3-methylimidazolium chloride, [Hmim][Cl]) and an ion-exchange reagent (lithium bis[(trifluoromethyl)sulfonyl]imide, LiNTf2) in sample solutions. The explosive 2,4,6-trinitrotoluene (TNT) was used as a model analyte to develop the method. The electrochemical behavior of TNT in [Hmim][NTf2] has been studied in SPELs. The extraction method was first optimized by use of a two-step multivariate optimization strategy, using Plackett–Burman and central composite designs. The method was then evaluated under optimum conditions and a good level of linearity was obtained, with a correlation coefficient of 0.9990. Limits of detection and quantification were 7 μg L−1 and 9 μg L−1, respectively. The repeatability of the proposed method was evaluated at two different spiking levels (20 and 50 μg L−1), and coefficients of variation of 7 % and 5 % (n = 5) were obtained. Tap water and industrial wastewater were selected as real-world water samples to assess the applicability of the method.
Resumo:
The electrochemical behaviour of o-cresol in acidic medium on platinum electrode has been studied by cyclic voltammetry and in situ Fourier transform infrared spectroscopy. The o-cresol suffers hydrolysis during oxidation giving rise to the formation of methyl-p-benzoquinone. In situ FTIR spectroscopic studies also reveal the presence of CO2, formed as a consequence of the rupture of the aromatic ring. Moreover, the oxidation of o-cresol in acidic medium produces a polymeric film on the platinum surface that precludes further oxidation of o-cresol. The reduction of o-cresol at potentials below 0 V produces in the first step the partial reduction of the aromatic ring and when the potential goes to values below 0 V, methyl-cyclohexanone.