918 resultados para high throughput
Resumo:
Quartz crystal impedance analysis has been developed as a technique to assess whether room-temperature ionic liquids are Newtonian fluids and as a small-volume method for determining the values of their viscosity-density product, rho eta. Changes in the impedance spectrum of a 5-MHz fundamental frequency quartz crystal induced by a water-miscible room-temperature ionic liquid, 1-butyl-3-methylimidazolium. trifluoromethylsulfonate ([C(4)mim][OTf]), were measured. From coupled frequency shift and bandwidth changes as the concentration was varied from 0 to 100% ionic liquid, it was determined that this liquid provided a Newtonian response. A second water-immiscible ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide [C(4)mim][NTf2], with concentration varied using methanol, was tested and also found to provide a Newtonian response. In both cases, the values of the square root of the viscosity-density product deduced from the small-volume quartz crystal technique were consistent with those measured using a viscometer and density meter. The third harmonic of the crystal was found to provide the closest agreement between the two measurement methods; the pure ionic liquids had the largest difference of similar to 10%. In addition, 18 pure ionic liquids were tested, and for 11 of these, good-quality frequency shift and bandwidth data were obtained; these 12 all had a Newtonian response. The frequency shift of the third harmonic was found to vary linearly with square root of viscosity-density product of the pure ionic liquids up to a value of root(rho eta) approximate to 18 kg m(-2) s(-1/2), but with a slope 10% smaller than that predicted by the Kanazawa and Gordon equation. It is envisaged that the quartz crystal technique could be used in a high-throughput microfluidic system for characterizing ionic liquids.
Resumo:
Rapid, quantitative SERS analysis of nicotine at ppm/ppb levels has been carried out using stable and inexpensive polymer-encapsulated Ag nanoparticles (gel-colls). The strongest nicotine band (1030 cm(-1)) was measured against d(5)-pyridine internal standard (974 cm(-1)) which was introduced during preparation of the stock gel-colls. Calibration plots of I-nic/I-pyr against the concentration of nicotine were non-linear but plotting I-nic/I-pyr against [nicotine](x) (x = 0.6-0.75, depending on the exact experimental conditions) gave linear calibrations over the range (0.1-10 ppm) with R-2 typically ca. 0.998. The RMS prediction error was found to be 0.10 ppm when the gel-colls were used for quantitative determination of unknown nicotine samples in 1-5 ppm level. The main advantages of the method are that the gel-colls constitute a highly stable and reproducible SERS medium that allows high throughput (50 sample h(-1)) measurements.
Resumo:
A study was performed to determine if targeted metabolic profiling of cattle sera could be used to establish a predictive tool for identifying hormone misuse in cattle. Metabolites were assayed in heifers (n ) 5) treated with nortestosterone decanoate (0.85 mg/kg body weight), untreated heifers (n ) 5), steers (n ) 5) treated with oestradiol benzoate (0.15 mg/kg body weight) and untreated steers (n ) 5). Treatments were administered on days 0, 14, and 28 throughout a 42 day study period. Two support vector machines (SVMs) were trained, respectively, from heifer and steer data to identify hormonetreated animals. Performance of both SVM classifiers were evaluated by sensitivity and specificity of treatment prediction. The SVM trained on steer data achieved 97.33% sensitivity and 93.85% specificity while the one on heifer data achieved 94.67% sensitivity and 87.69% specificity. Solutions of SVM classifiers were further exploited to determine those days when classification accuracy of the SVM was most reliable. For heifers and steers, days 17-35 were determined to be the most selective. In summary, bioinformatics applied to targeted metabolic profiles generated from standard clinical chemistry analyses, has yielded an accurate, inexpensive, high-throughput test for predicting steroid abuse in cattle.
Resumo:
Zygotes of the fucoid brown algae provide excellent models for addressing fundamental questions about zygotic symmetry breaking. Although the acquisition of polarity is tightly coordinated with the timing and orientation of the first asymmetric division-with zygotes having to pass through a G1/S-phase checkpoint before the polarization axis can be fixed -the mechanisms behind the interdependence of polarization and cell cycle progression remain unclear. In this study, we combine in vivo Ca(2+) imaging, single cell monitoring of S-phase progression and multivariate analysis of high-throughput intracellular Ca(2+) buffer loading to demonstrate that Ca(2+) signals coordinate polarization and cell cycle progression in the Fucus serratus zygote. Consistent with earlier studies on this organism, and in contrast to animal models, we observe no fast Ca(2+) wave following fertilization. Rather, we show distinct slow localized Ca(2+) elevations associated with both fertilization and S-phase progression, and we show that both S-phase and zygotic polarization are dependent on pre-S-phase Ca(2+) increases. Surprisingly, this Ca(2+) requirement cannot be explained by co-dependence on a single G1/ S-phase checkpoint, as S phase and zygotic polarization are differentially sensitive to pre-S-phase Ca(2+) elevations and can be uncoupled. Furthermore, subsequent cell cycle progression through M phase is independent of localized actin polymerization and zygotic polarization. This absence of a morphogenesis checkpoint, together with the observed Ca(2+)dependences of S phase and polarization, show that the regulation of zygotic division in the brown algae differs from that in other eukaryotic model systems, such as yeast and Drosophila.
Resumo:
This paper presents a matrix inversion architecture based on the novel Modified Squared Givens Rotations (MSGR) algorithm, which extends the original SGR method to complex valued data, and also corrects erroneous results in the original SGR method when zeros occur on the diagonal of the matrix either initially or during processing. The MSGR algorithm also avoids complex dividers in the matrix inversion, thus minimising the complexity of potential real-time implementations. A systolic array architecture is implemented and FPGA synthesis results indicate a high-throughput low-latency complex matrix inversion solution. © 2008 IEEE.
Resumo:
A new reconfigurable subpixel interpolation architecture for multistandard (e.g., MPEG-2, MPEG-4, H.264, and AVS) video motion estimation (ME) is presented. This exploits the mixed use of parallel and serial-input FIR filters to achieve high throughput rate and efficient silicon utilization. Silicon design studies show that this can be implemented using 34.8 × 10 3 gates with area and performance that compares very favorably with specific fixed solutions, e.g., for the H.264 standard alone. This can support SDTV and HDTV applications when implemented in 0.18 µm CMOS technology, with further performance enhancements achievable at 0.13 µm and below. © 2009 IEEE.
Resumo:
The fundamental difference between classic and modern biology is that technological innovations allow to generate high-throughput data to get insights into molecular interactions on a genomic scale. These high-throughput data can be used to infer gene networks, e. g., the transcriptional regulatory or signaling network, representing a blue print of the current dynamical state of the cellular system. However, gene networks do not provide direct answers to biological questions, instead, they need to be analyzed to reveal functional information of molecular working mechanisms. In this paper we propose a new approach to analyze the transcriptional regulatory network of yeast to predict cell cycle regulated genes. The novelty of our approach is that, in contrast to all other approaches aiming to predict cell cycle regulated genes, we do not use time series data but base our analysis on the prior information of causal interactions among genes. The major purpose of the present paper is to predict cell cycle regulated genes in S. cerevisiae. Our analysis is based on the transcriptional regulatory network, representing causal interactions between genes, and a list of known periodic genes. No further data are used. Our approach utilizes the causal membership of genes and the hierarchical organization of the transcriptional regulatory network leading to two groups of periodic genes with a well defined direction of information flow. We predict genes as periodic if they appear on unique shortest paths connecting two periodic genes from different hierarchy levels. Our results demonstrate that a classical problem as the prediction of cell cycle regulated genes can be seen in a new light if the concept of a causal membership of a gene is applied consequently. This also shows that there is a wealth of information buried in the transcriptional regulatory network whose unraveling may require more elaborate concepts than it might seem at first.
Resumo:
Substituted 3-(phenylamino)-1H-pyrrole-2,5-diones were identified from a high throughput screen as inducers of human ATP binding cassette transporter A1 expression. Mechanism of action studies led to the identification of GSK3987 (4) as an LXR ligand. 4 recruits the steroid receptor coactivator-1 to human LXR alpha and LXRP with EC(50)s of 40 nM, profiles as an LXR agonist in functional assays, and activates LXR though a mechanism that is similar to first generation LXR agonists.
Resumo:
PURPOSE: Retinitis pigmentosa (RP) causes hereditary blindness in adults (prevalence, approximately 1 in 4000). Each of the more than 30 causative genes identified to date are responsible for only a small percentage of cases. Genetic diagnosis via traditional methods is problematic, and a single test with a higher probability of detecting the causative mutation would be very beneficial for the clinician. The goal of this study therefore was to develop a high-throughput screen capable of detecting both known mutations and novel mutations within all genes implicated in autosomal recessive or simplex RP. DESIGN: Evaluation of diagnostic technology. PARTICIPANTS AND CONTROLS: Participants were 56 simplex and autosomal recessive RP patients, with 360 population controls unscreened for ophthalmic disease. METHODS: A custom genechip capable of resequencing all exons containing known mutations in 19 disease-associated genes was developed (RP genechip). A second, commercially available arrayed primer extension (APEX) system was used to screen 501 individual previously reported variants. The ability of these high-throughput approaches to identify pathogenic variants was assessed in a cohort of simplex and autosomal recessive RP patients. MAIN OUTCOME MEASURES: Number of mutations and potentially pathogenic variants identified. RESULTS: The RP genechip identified 44 sequence variants: 5 previously reported mutations; 22 known single nucleotide polymorphisms (SNPs); 11 novel, potentially pathogenic variants; and 6 novel SNPs. There was strong concordance with the APEX array, but only the RP genechip detected novel variants. For example, identification of a novel mutation in CRB1 revealed a patient, who also had a single previously known CRB1 mutation, to be a compound heterozygote. In some individuals, potentially pathogenic variants were discovered in more than one gene, consistent with the existence of disease modifier effects resulting from mutations at a second locus. CONCLUSIONS: The RP genechip provides the significant advantage of detecting novel variants and could be expected to detect at least one pathogenic variant in more than 50% of patients. The APEX array provides a reliable method to detect known pathogenic variants in autosomal recessive RP and simplex RP patients and is commercially available. High-throughput genotyping for RP is evolving into a clinically useful genetic diagnostic tool.
Resumo:
A new domain-specific, reconfigurable system-on-a-chip (SoC) architecture is proposed for video motion estimation. This has been designed to cover most of the common block-based video coding standards, including MPEG-2, MPEG-4, H.264, WMV-9 and AVS. The architecture exhibits simple control, high throughput and relatively low hardware cost when compared with existing circuits. It can also easily handle flexible search ranges without any increase in silicon area and can be configured prior to the start of the motion estimation process for a specific standard. The computational rates achieved make the circuit suitable for high-end video processing applications, such as HDTV. Silicon design studies indicate that circuits based on this approach incur only a relatively small penalty in terms of power dissipation and silicon area when compared with implementations for specific standards. Indeed, the cost/performance achieved exceeds that of existing but specific solutions and greatly exceeds that of general purpose field programmable gate array (FPGA) designs.
Resumo:
The spontaneous formation of the neurotoxic carcinogen acrylamide in a wide range of cooked foods has recently been discovered, leading to dietary exposure estimates of 30.8 mu g of acrylamide day(-1) for an average 77 kg human male. This is considerably higher than the European legal limit of acrylamide in drinking water, which is approximately 0.2 mu g of acrylamide person(-1) day(-1). A recent study of 62,573 women over 11.3 years has observed an increased risk of postmenopausal endometrial and ovarian cancer (but not breast cancer) with increasing dietary acrylamide intake, demonstrating significant risk to human health. As individual acrylamide exposure is affected by dietary habits, cooking methods, and cigarette consumption; accurate extrapolation from estimated dietary exposure is extremely difficult. Quantifying biomarkers of acrylamide exposure therefore remains the most effective means of rapidly determining individual exposure to acrylamide, and correlating exposure with lifestyle choices. Current methodologies for the analysis of blood biomarkers of acrylamide are focused on expensive, slower chromatographic techniques such as GC and LC coupled to mass spectrometry. This paper describes the first successful development of two monoclonal antibodies specific to acrylamide-adducted haemoglobin (IC50 of 94 ng ml(-1) and 198 ng ml(-1)), that are suitable for use in a high-throughput biomarker immunoassay to determine individual acrylamide exposure. Further development of acrylamide-haemoglobin standards with defined levels of acrylamide adduction will enable a fully quantitative assay, and allow sensitivity comparisons with alternative chromatographic methods of analysis. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Background
Inferring gene regulatory networks from large-scale expression data is an important problem that received much attention in recent years. These networks have the potential to gain insights into causal molecular interactions of biological processes. Hence, from a methodological point of view, reliable estimation methods based on observational data are needed to approach this problem practically.
Results
In this paper, we introduce a novel gene regulatory network inference (GRNI) algorithm, called C3NET. We compare C3NET with four well known methods, ARACNE, CLR, MRNET and RN, conducting in-depth numerical ensemble simulations and demonstrate also for biological expression data from E. coli that C3NET performs consistently better than the best known GRNI methods in the literature. In addition, it has also a low computational complexity. Since C3NET is based on estimates of mutual information values in conjunction with a maximization step, our numerical investigations demonstrate that our inference algorithm exploits causal structural information in the data efficiently.
Conclusions
For systems biology to succeed in the long run, it is of crucial importance to establish methods that extract large-scale gene networks from high-throughput data that reflect the underlying causal interactions among genes or gene products. Our method can contribute to this endeavor by demonstrating that an inference algorithm with a neat design permits not only a more intuitive and possibly biological interpretation of its working mechanism but can also result in superior results.
Resumo:
An enzyme labeled immunosorbent assay (ELISA) and surface plasmon resonance (SPR) biosensor assay for the detection of paralytic shellfish poisoning (PSP) toxins were developed and a comparative evaluation was performed. A polyclonal antibody (BC67) used in both assay formats was raised to saxitoxin–jeffamine–BSA in New Zealand white rabbits. Each assay format was designed as an inhibition assay. Shellfish samples (n = 54) were evaluated by each method using two simple rapid extraction procedures and compared to the AOAC high performance liquid chromatography (HPLC) and the mouse bioassay (MBA). The results of each assay format were comparable with the HPLC and MBA methods and demonstrate that an antibody with high sensitivity and broad specificity to PSP toxins can be applied to different immunological techniques. The method of choice will depend on the end-users needs. The reduced manual labor and simplicity of operation of the SPR biosensor compared to ELISA, ease of sample extraction and superior real time semi-quantitative analysis are key features that could make this technology applicable in a high-throughput monitoring unit.
Resumo:
The recent emergence of high-throughput arrays for methylation analysis has made the influence of tumor content on the interpretation of methylation levels increasingly pertinent. However, to what degree does tumor content have an influence, and what degree of tumor content makes a specimen acceptable for accurate analysis remains unclear. Taking a systematic approach, we analyzed 98 unselected formalin-fixed and paraffin-embedded gastric tumors and matched normal tissue samples using the Illumina GoldenGate methylation assay. Unsupervised hierarchical clustering showed 2 separate clusters with a significant difference in average tumor content levels. The probes identified to be significantly differentially methylated between the tumors and normals also differed according to the tumor content of the samples included, with the sensitivity of identifying the
Resumo:
Formalin fixed and paraffin embedded tissue (FFPE) collections in pathology departments are the largest resource for retrospective biomedical research studies. Based on the literature analysis of FFPE related research, as well as our own technical validation, we present the Translational Research Arrays (TRARESA), a tissue microarray centred, hospital based, translational research conceptual framework for both validation and/or discovery of novel biomarkers. TRARESA incorporates the analysis of protein, DNA and RNA in the same samples, correlating with clinical and pathological parameters from each case, and allowing (a) the confirmation of new biomarkers, disease hypotheses and drug targets, and (b) the postulation of novel hypotheses on disease mechanisms and drug targets based on known biomarkers. While presenting TRARESA, we illustrate the use of such a comprehensive approach. The conceptualisation of the role of FFPE-based studies in translational research allows the utilisation of this commodity, and adds to the hypothesis-generating armamentarium of existing high-throughput technologies.