944 resultados para Quality audit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lean Thinking is an important pillar in the success of any program of continuous improvement process. Its tools are useful means in the analysis, control and organization of important data for correct decision making in organizations. This project had as main objective the design of a program of quality improvement in Eurico Ferreira, S.A., based on the evaluation of customer satisfaction and the implementation of 5S. Subsequently, we have selected which business area of the company to address. After the selection, there was an initial diagnostic procedure, identifying the various points of improvement to which some tools of Lean Thinking have been applied, in particular Value Stream Mapping and 5S methodology. With the first, we were able to map the current state of the process in which all stakeholders were represented as well as the flow of materials and information throughout the process. The 5S methodology allowed to act on the wastage, identifying and implementing various process improvements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measuring the quality of a b-learning environment is critical to determine the success of a b-learning course. Several initiatives have been recently conducted on benchmarking and quality in e-learning. Despite these efforts in defining and examining quality issues concerning online courses, a defining instrument to evaluate quality is one of the key challenges for blended learning, since it incorporates both traditional and online instruction methods. For this paper, six frameworks for quality assessment of technological enhanced learning were examined and compared regarding similarities and differences. These frameworks aim at the same global objective: the quality of e-learning environment/products. They present different perspectives but also many common issues. Some of them are more specific and related to the course and other are more global and related to institutional aspects. In this work we collected and arrange all the quality criteria identified in order to get a more complete framework and determine if it fits our b-learning environment. We also included elements related to our own b-learning research and experience, acquired during more than 10 years of experience. As a result we have create a new quality reference with a set of dimensions and criteria that should be taken into account when you are analyzing, designing, developing, implementing and evaluating a b-learning environment. Besides these perspectives on what to do when you are developing a b-learning environment we have also included pedagogical issues in order to give directions on how to do it to reach the success of the learning. The information, concepts and procedures here presented give support to teachers and instructors, which intend to validate the quality of their blended learning courses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A revision of several paths for the Quality journey is presented: from Quality Gurus and Total Quality Management (TQM) models to the ISO 9000 International Standards Series. Since ISO 9001:2008 is now in the revision process to the expected ISO 9001:2015 version, an analysis is made of he proposed changes and the underlying reasons and the impacts foreseen on the more than 1.3 Million certified organizations. This revision should be a step towards TQM and reflect the changes of an increasingly complex, demanding and dynamic environment, while assuring that complying organizations are able to provide conformity products and services that satisfy their customers. Major benefits are expected such as less emphasis on documentation and new/reinforced approaches: consideration of Organizational Context and (relevant) Stakeholders, Risk Based thinking and Knowledge Management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Um dos princípios da Gestão é: “If you cannot measure it, you cannot improve it.” In The Economist – 26.Dez.2008, idea of 19th century English physicist Lord Kelvin. Embora seja uma afirmação aplicável à gestão económica, também pode ser utilizada no domínio da gestão da energia. Este trabalho surge da necessidade sentida pela empresa Continental - Industria Têxtil do Ave, S.A. em efetuar uma atualização dos seus standards de produção, minimizando os seus consumos de eletricidade e gás natural. Foi necessário efetuar o levantamento dos consumos em diversas máquinas e equipamentos industriais, caracterizando e analisando os consumos ao longo de todo o processo produtivo. Para o tratamento de dados recolhidos foi desenvolvida uma folha de cálculo em MS Office ExcelTM com metodologia adequada ao equipamento em análise, que dará apoio ao decisor para a identificação dos aspetos que melhorem o processo produtivo e garantam uma elevada eficiência energética. Porém, não se enquadra no âmbito do Plano Nacional de Racionalização de Energia, sendo uma “auditoria energética” ao processo produtivo. Recentemente, a empresa, tem vindo a utilizar equipamentos eletrónicos que permitem otimizar o funcionamento mecânico dos equipamentos e das potências instaladas dos transformadores, na tentativa de racionalizar o consumo da energia elétrica. Outros equipamentos como, conversores de frequência para controlo de motores, balastros eletrónicos que substituem os convencionais balastros ferromagnéticos das lâmpadas de descarga fluorescente, têm sido incluídos ao nível das instalações elétricas, sendo gradualmente substituída a eletromecânica pela eletrónica. Este tipo de soluções vem deteriorar as formas de onda da corrente e da tensão do sistema pela introdução de distorções harmónicas. Faz ainda parte deste trabalho, um estudo de uma solução que melhore, simultaneamente o fator de potência e reduza as harmónicas presentes num posto de transformação localizado no seio da fábrica. Esta solução, permite melhorar a qualidade da energia elétrica e as condições de continuidade de serviço, garantindo melhores condições de exploração e incrementando a produtividade da empresa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O registo clinico é um documento hospitalar confidencial, nele é registado todo o percurso clinico de um determinado paciente. Esse percurso é registado através da atribuição de códigos descritos num sistema de classificação, também denominados de dados da codificação. Os dados da codificação são armazenados electronicamente numa Base de Dados, e é a partir dela que certas medidas, tais como facturação hospitalar, financiamentos hospitalares anuais, tratamentos médicos, ou até mesmo dados epidemiológicos, são adotadas. Portanto torna-se fundamental a garantia da qualidade na área da codificação clinica, para isso é necessário recorrer a processos de auditorias aos registos clínicos. O processo de auditoria é uma atividade independente de avaliação, cujo objetivo visa acrescentar valor e melhorar os objetos e processos da auditoria. Atualmente uma ferramenta denominada de Programa Auditor é utilizada, contudo essa ferramenta demonstra uma tecnologia já ultrapassada. A Tese que se pretende defender é a de que, através de Sistemas Periciais, é possível realizar auditorias internas aos registos clínicos. Pretende-se ainda demonstrar que dos Sistemas Periciais e um benefício para os peritos na área, pois diminui a probabilidade de erros e torna o processo de verificação menos moroso. Neste contexto, o objetivo desta Dissertação prende-se em definir e implementar um Sistema Pericial que permita a auditoria de registos clínicos hospitalares. O Sistema Pericial dever a ainda ser capaz de traduzir o raciocínio do perito, detectando assim diversos tipos de erros que traduzem num registo clínico não conforme. Por sua vez, foi desenvolvido um protótipo de um Sistema Pericial para auditoria de registos clínicos em linguagem PROLOG. Este mesmo protótipo serviu de base à realização de uma experiência que permitiu comparar com o programa Auditor e verificar a sua aplicabilidade no dia-a-dia hospitalar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low back problems are associated with decreased quality of life. Specific exercises can improve quality of life, resulting in better professional performance and functionality. The purpose of this study was to evaluate the effect of following a 21-month exercise program on the quality of life of warehouse workers. The population included 557 male warehouse workers from a food distribution company in Oporto, Portugal. Upon application of the selection criteria, 249 workers were deemed eligible, which were randomized into two groups (125 in the intervention group and 124 in the control group). Then, subjects were asked to volunteer for the study, the sample being formed by 229 workers (112 in the intervention group and 117 in the control group). All subjects completed the SF-36 questionnaire prior to beginning the program and on the 11th and 21st months following it. The exercises were executed in the company facilities once a day for 8 min. Data were analyzed using SPSS® 17.0 for Windows®. After 11 months of following the exercise program, there was an increase in all scores for the experimental group, with statistically significant differences in the dimensions physical functioning (0.019), bodily pain (0.010), general health (0.004), and rolephysical (0.037). The results obtained at the end of the study (21 months) showed significant improvements in the dimensions physical functioning (p = 0.002), rolephysical (p = 0.007), bodily pain (p = 0.001), social functioning (p = 0.015), role-emotional (p = 0.011), and mental health (p = 0.001). In the control group all dimensions showed a decrease in mean scores. It can be concluded that the implementation of a low back specific exercise program has changed positively the quality of life of warehouse workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the components of the Fuenzalida-Palacios antirabies vaccine, which is till used in most developing countries in human immunization for treatment and prophylaxis. This vaccine is prepared from newborn mouse brains at 1% concentration. Even though the vaccine is considered to have a low myelin content, it is not fully free of myelin or of other undesirable components that might trigger adverse effects after vaccination. The most severe effect is a post-vaccination neuroparalytic accident associated with Guillain-Barré syndrome. In the present study we demonstrate how the vaccines produced and distributed by different laboratories show different component patterns with different degrees of impurity and with varying protein concentrations, indicating that production processes can vary from one laboratory to another. These differences, which could be resolved using a better quality control process, may affect and impair immunization, with consequent risks and adverse effects after vaccination. We used crossed immunoelectrophoresis to evaluate and demonstrate the possibility of quality control in vaccine production, reducing the risk factors possibly involved in these immunizing products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação tem como principal propósito avaliar o desempenho energético e a qualidade do ar interior do edifício principal do Parque Biológico de Vila Nova de Gaia (PBG). Para esse efeito, este estudo relaciona os termos definidos na legislação nacional em vigor até à presente data, e referentes a esta área de atuação, em particular, os presentes no SCE, RSECE, RCCTE e RSECE-QAI. Para avaliar o desempenho energético, procedeu-se numa primeira fase ao processo de auditoria no local e posteriormente à realização de uma simulação dinâmica detalhada, cuja modelação do edifício foi feita com recurso ao software DesignBuilder. Após a validação do modelo simulado, por verificação do desvio entre os consumos energéticos registados nas faturas e os calculados na simulação, igual a 5,97%, foi possível efetuar a desagregação dos consumos em percentagem pelos diferentes tipos de utilizações. Foi também possível determinar os IEE real e nominal, correspondendo a 29,9 e 41.3 kgep/m2.ano, respetivamente, constatando-se através dos mesmos que o edifício ficaria dispensado de implementar um plano de racionalização energética (PRE) e que a classe energética a atribuir é a C. Contudo, foram apresentadas algumas medidas de poupança de energia, de modo a melhorar a eficiência energética do edifício e reduzir a fatura associada. Destas destacam-se duas propostas, a primeira propõe a alteração do sistema de iluminação interior e exterior do edifício, conduzindo a uma redução no consumo de eletricidade de 47,5 MWh/ano, com um período de retorno de investimento de 3,5 anos. A segunda está relacionada com a alteração do sistema de produção de água quente para o aquecimento central, através do incremento de uma caldeira a lenha ao sistema atual, que prevê uma redução de 50 MWh no consumo de gás natural e um período de retorno de investimento de cerca de 4 anos. Na análise realizada à qualidade do ar interior (QAI), os parâmetros quantificados foram os exigidos legalmente, excetuando os microbiológicos. Deste modo, para os parâmetros físicos, temperatura e humidade relativa, obtiveram-se os resultados médios de 19,7ºC e 66,9%, respetivamente, ligeiramente abaixo do previsto na legislação (20,0ºC no período em que foi feita a medição, inverno). No que diz respeito aos parâmetros químicos, os valores médios registados para as concentrações de dióxido de carbono (CO2), monóxido de carbono (CO), ozono (O3), formaldeído (HCHO), partículas em suspensão (PM10) e radão, foram iguais a 580 ppm, 0,2 ppm, 0,06 ppm, 0,01 ppm, 0,07 mg/m3 e 196 Bq/m3, respetivamente, verificando-se que estão abaixo dos valores máximos de referência presentes no regulamento (984 ppm, 10,7 ppm, 0,10 ppm, 0,08 ppm, 0,15 mg/m3 e 400 Bq/m3). No entanto, o parâmetro relativo aos compostos orgânicos voláteis (COV) teve um valor médio igual a 0,84 ppm, bastante acima do valor máximo de referência (0,26 ppm). Neste caso, terá que ser realizada uma nova série de medições utilizando meios cromatográficos, para avaliar qual(ais) são o(s) agente(s) poluidor(es), de modo a eliminar ou atenuar as fontes de emissão.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação tem dois objetivos, o primeiro é a realização de uma auditoria energética e avaliação da qualidade do ar às instalações de uma Piscina Municipal, permitindo a sua classificação energética, e o segundo é o estudo de propostas de melhoria que contribuam para uma melhor eficiência energética do edifício. Na análise à qualidade do ar interior os parâmetros avaliados encontravam-se todos dentro dos limites estabelecidos por lei, com exceção dos valores de COVs que em dois pontos de medição (ambos na nave) ultrapassaram os limites estabelecidos por lei. A auditoria ao edifício permitiu verificar que o caudal mínimo de água nova nas piscinas imposto por lei é cumprido pela instalação. No que diz respeito ao caudal de ar novo introduzido, este apenas é respeitado quando a unidade de tratamento de ar está a debitar 100% da sua capacidade. Quando a unidade opera a 50% da sua capacidade apresenta um défice de 5% do valor mínimo estabelecido. Relativamente às perdas energéticas associadas aos tanques de natação, estas apresentam um valor de 95,89 kW, em que 59,09 kW dizem respeito às perdas por evaporação. Foi também possível concluir que as perdas por evaporação representam cerca de 39% da energia calorifica produzida nas caldeiras. O edifício apresenta um consumo anual de eletricidade de 166 482 kWh em que 69% deste valor é provocado pelas unidades de tratamento de ar e a iluminação apresenta apenas um peso de 3%. Em relação ao gás natural consumido pelas caldeiras o seu valor anual é de 1 317 240 kWh. A simulação dinâmica do edifício permitiu concluir que este apresenta um IEE de 1 269,9 kWh/m2.ano. O rácio de classe energética (RIEE) é de 1,24 o que significa que o edifício pertence à classe energética C. As medidas estudadas para a melhoria da eficiência energética, nomeadamente integração energética com uma central de ciclo combinado, aplicação de cobertura isotérmica nas piscinas e substituição do telhado na zona da nave, mostraram-se viáveis. O estudo da possibilidade da realização de uma integração energética permitiu concluir que a poupança anual é de 9 374 € e o investimento é recuperado em menos de 1,5 anos. Relativamente à aplicação de cobertura isotérmica o investimento é de 14 000 € e é recuperado em 2 anos. A substituição do telhado na zona da nave tem um investimento de 20 500 € e a recuperação realiza-se num período de 3,5 anos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whereas child care quality has been extensively studied in the U.S., there is much less information about the quality of child care in other countries.With one of the highest maternal employment rates in Europe, it is important to examine child care in Portugal. Thirty toddler classrooms in child care centers were observed. The purpose of this studywas to determine whether structural features account for overall toddler child care quality. Results showed younger and better-paid teachers provided better toddler child care quality. Space available per childwas not a statistically significant predictor of toddler child care quality.Overall quality results suggest some issues to be addressed by early education policy makers and indicate the need to promote quality in Portuguese toddler child care programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gestão de Energia e Sustentabilidade são os pilares em que assenta esta dissertação, realizada no âmbito da Energia Elétrica em Ambiente Industrial. Neste sentido, deve entender-se “Gestão de Energia” como o planeamento de operações nas unidades de produção e de consumo. Tem como objetivos a conservação dos recursos, proteção climática e redução de custos, para que seja possível o acesso permanente à energia de que necessitamos. “Sustentabilidade”, por definição, é uma caraterística ou condição de um processo ou de um sistema que permite a sua permanência, até um determinado nível, por um determinado prazo. A Indústria Têxtil, da região do Vale do Ave, por ser extensa e muito heterogénea, quer na qualidade, quer na dimensão e nos recursos que utiliza, apresentou-se como uma oportunidade para aplicar os conhecimentos adquiridos, nas diversas disciplinas do Mestrado em Engenharia Electrotécnica - Área de Sistemas Eléctricos de Energia e como meio condutor à tentativa de optimização e racionalização do consumo de Energia Elétrica no Sector. O modelo encontrado para dar uma resposta satisfatória ao inicialmente proposto foi a Auditoria Energética. Neste sentido, foram realizadas visitas às instalações industriais, para o levantamento e recolha de informação, que posteriormente viria a ser analisada e, com base na mesma, tentou apresentar-se um conjunto de soluções que visassem a eficiência Energética do sector. Com o decorrer das visitas, surgiu a necessidade de criar um modelo, que servisse de guia da auditoria. Algo que seria um bloco de notas, mas específico, de forma a não perder a informação recolhida. Então foi desenvolvida uma aplicação para IPAD/IPHONE, o que permite também a recolha e armazenamento de fotografias, que aqui tem um papel fundamental. Salienta-se que as expectativas foram ao encontro do esperado, pois o que se encontrou foi um número significativo de empresas a precisar deste contributo. Atuando no “combate” ao consumo desnecessário e ao desperdício, é estar a contribuir ativa e positivamente, no desenvolvimento próspero da temática de Sustentabilidade Energética.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clothing sector in several countries is still seen, in many aspects as a traditional sector with some average characteristics, nevertheless is a very important sector in terms of labour market. Globalization and de-localization are having a strong impact in the organisation of work and in occupational careers. Very few companies are able to keep a position in the market without changes in organisation of work and workers, founding different ways to face this reality according to size, capital and position. We could find two main paths: one where companies outsource production to another territory, close and/ or dismissal the workers; other path, where companies up skilled their capacities. This paper will present some results from the European project WORKS – Work organisation and restructuring in the knowledge society (6th Framework Programme), focusing the Portuguese case studies in several clothing companies in a comparative analysis with some other European countrie

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado apresentada ao Instituto Superior de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Contabilidade e Finanças, sob orientação do Dr. Rodrigo Mário de Oliveira Carvalho