765 resultados para MEASURING DEVICES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a mesurement system designed to register the displacement of the legs using a two-dimensional laser range sensor with a scanning plane parallel to the ground and extract gait parameters. In the proposed methodology, the position of the legs is estimated by fitting two circles with the laser points that define their contour and the gait parameters are extracted applying a step-line model to the estimated displacement of the legs to reduce uncertainty in the determination of the stand and swing phase of the gait. Results obtained in a range up to 8 m shows that the systematic error in the location of one static leg is lower than 10 mm with and standard deviation lower than 8 mm; this deviation increases to 11 mm in the case of a moving leg. The proposed measurement system has been applied to estimate the gait parameters of six volunteers in a preliminary walking experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to provide an instrument for measuring service quality in sports enterprises from the point of view of the customers. For this purpose we intend to elaborate an enquiry starting out from a more general scale called SERVIQUAL. We have limited our research project to sports enterprises where the customer participates actively, i.e., we have excluded sports clubs and other organizations which offer sport as entertainment. Our choice is mainly due to the fact that few studies have been carried out in this area and that sports has been earning an increasing amount of adepts during the last decades in Spain. The DELPHI method has been applied with the collaboration of a panel of experts in order to evaluate the viability and adequacy of the modified SERVQUAL scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the analysis of different walking paths registered using a Light Detection And Ranging (LIDAR) laser range sensor in order to measure oscillating trajectories during unsupervised walking. The estimate of the gait and trajectory parameters were obtained with a terrestrial LIDAR placed 100 mm above the ground with the scanning plane parallel to the floor to measure the trajectory of the legs without attaching any markers or modifying the floor. Three different large walking experiments were performed to test the proposed measurement system with straight and oscillating trajectories. The main advantages of the proposed system are the possibility to measure several steps and obtain average gait parameters and the minimum infrastructure required. This measurement system enables the development of new ambulatory applications based on the analysis of the gait and the trajectory during a walk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heart transplantation (HTx) is the treatment of choice for end-stage heart failure but the limited availability of heart's donors still represents a major issue. So long-term mechanical circulatory support (MCS) has been proposed as an alternative treatment option to assist patients scheduled on HTx waiting list bridging them for a variable time period to cardiac transplantation-the so-called bridge-to-transplantation (BTT) strategy. Nowadays approximately 90% of patients being considered for MCS receive a left ventricular assist device (LVAD). In fact, LVAD experienced several improvements in the last decade and the predominance of continuous-flow over pulsatile-flow technology has been evident since 2008. The aim of the present report is to give an overview of continuous-flow LVAD utilization in the specific setting of the BTT strategy taking into consideration the most representative articles of the scientific literature and focusing the attention on the evolution, clinical outcomes, relevant implications on the HTx strategy and future perspectives of the continuous-flow LVAD technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diplomityössä luotiin katsaus sellu- ja paperiteollisuuden haitallisimpiin ilmapäästöihin ja ilmapäästömäärien kehitykseen Suomessa 1990-luvun alusta nykypäivään. Työssä tutustuttiin sellu- ja paperiteollisuuden ilmapäästöjä rajoittavan lainsäädännön ajankohtaisiin asioihin Suomessa ja Euroopan Unionissa, sekä tarkasteltiin nykyisen lainsäädännön perustana olleita ilmastosopimuksia eli kansainvälisen ilmastopolitiikan syntyä ja kehittymistä. Työssä on myös selvitetty ilman osuutta paperinvalmistuksessa, tutustuttu ilmapäästöjen rajoittamismenetelmiin ja eri mittausmenetelmiin ilmapäästöjen toteamiseksi. Työn puitteissa suoritettiin mittalaitetestejä eri paperitehtailla. Haitallisimpia ja määrällisesti suurimpia ilmapäästöjä sellu- ja paperiteollisuudessa ovat typen ja rikin oksidit, pelkistyneet rikkiyhdisteet, hiukkaset, haihtuvat orgaaniset yhdisteet (VOC) ja hiilidioksidi. Ilmapäästömäärät Suomessa ovat typenoksideja lukuun ottamatta olleet laskussa 1990-luvun alusta nykypäivään. Tärkein kasvihuonekaasu on hiilidioksidi, jonka määrää rajoitetaan Kioton sopimuksessa. Vuoden 2002 aikana selvinneekin, mikä on Kioton sopimuksen vaikutus Suomen metsäteollisuuteen. Päästömittauksia tarvitaan lainsäädännön raja-arvojen toteamiseksi, mittauksia suorittavat sertifioidut päästömittauslaboratoriot. Suoritetuissa mittalaitetesteissä havaittiin mittalaitteiden soveltuvuudessa kosteiden paperiprosessin poistokaasujen määrittämiseen suuria eroja.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Occupational therapists could play an important role in facilitating driving cessation for ageing drivers. This, however, requires an easy-to-learn, standardised on-road evaluation method. This study therefore investigates whether use of P-drive' could be reliably taught to occupational therapists via a short half-day training session. Method Using the English 26-item version of P-drive, two occupational therapists evaluated the driving ability of 24 home-dwelling drivers aged 70 years or over on a standardised on-road route. Experienced driving instructors' on-road, subjective evaluations were then compared with P-drive scores. Results Following a short half-day training session, P-drive was shown to have almost perfect between-rater reliability (ICC2,1=0.950, 95% CI 0.889 to 0.978). Reliability was stable across sessions including the training phase even if occupational therapists seemed to become slightly less severe in their ratings with experience. P-drive's score was related to the driving instructors' subjective evaluations of driving skills in a non-linear manner (R-2=0.445, p=0.021). Conclusion P-drive is a reliable instrument that can easily be taught to occupational therapists and implemented as a way of standardising the on-road driving test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monet henkilökohtaiset mobiililaitteet tarjoavat mahdollisuuden tallentaa henkilötietoja ja mahdollisuuden lyhyen kantaman radiotekniikoiden hyödyntämiseen. Vastaavasti henkilötietoja käyttävien tai vaativien verkkopalveluiden määrä on kasvussa. Mobiililaitteisiin tallennetut henkilötiedot tarjoavat potentiaalisen keinon välttää samojen henkilötietojen toistuva käsinsyöttö erilaisiin verkkopalveluihin ja keskitettyyn ajantasallapitoon. Tässä työssä käydään läpi ratkaisumalli henkilökohtaisen mobiililaitteen ja verkkopalveluiden välillä tapahtuvaan henkilötietojen siirtoon ja synkronointiin. Malli pohjautuu selainlaajennukseen, joka voi pyytää sekä selaimessa auki olevalta verkkopalvelun sivulta että mobiililta päätelaitteelta senhetkiset henkilötiedot ja synkronoida ne. Jo olemassaolevia henkilötietojen hallintaa helpottavia ratkaisuja käydään läpi arvioiden käyttökelpoisuutta tämänkaltaisiin tarpeisiin. Ratkaisumallin kannalta olennaiset tekniikat ja standardit, erityisesti Bluetooth ja SyncML, esitellään. Ratkaisumallin arkkitehtuuri käydään korkealla tasolla läpi ja esitellään toteutuksen yksityiskohtia. Tuloksena on periaatteeltaan kelvollinen henkilökohtaisten tietojen synkronointijärjestelmä, jonka toteutusta nykyisten mobiilien päätelaitteiden toiminnallisuus jossain määrin hankaloittaa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universal Converter (UNICON) –projektin osana suunniteltiin sähkömoottorikäyttöjen ohjaukseen ja mittaukseen soveltuva digitaaliseen signaaliprosessoriin (DSP) pohjautuva sulautettu järjestelmä. Riittävän laskentatehon varmistamiseksi päädyttiin käyttämään moniprosessorijärjestelmää. Prosessorijärjestelmässä käytettävää DSP-piiriä valittaessa valintaperusteina olivat piirien tarjoama prosessointiteho ja moniprosessorituki. Analog Devices:n SHARC-sarjan DSP-piirit täyttivät parhaiten asetetut vaatimukset: Ne tarjoavat tehokkaan käskykannan lisäksi suuren sisäisen muistin ja sisäänrakennetun moniprosessorituen. Järjestelmän mittalaiteluonteisuudesta johtuen keskeinen suunnitteluparametri oli luoda nopeat tiedonsiirtoyhteydet mittausantureilta DSP-järjestelmään. Tämä toteutettiin käyttäen ohjelmointavia FPGA-logiikkapiirejä digitaalimuotoisen mittausdatan vastaanotossa ja esikäsittelyssä. Tiedonsiirtoyhteys PC-tietokoneelle toteutettiin käyttäen erityistä liityntäkorttia DSP-järjestelmän ja PC-tietokoneen välillä. Liityntäkortin päätehtävänä on puskuroida siirrettävä data. Järjestelyllä estetään PC-tietokoneen vaikutus DSP-järjestelmän toimintaan, jotta kyetään takaamaan järjestelmän reaaliaikainen toiminta kaikissa olosuhteissa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän työn tarkoituksena oli tutkia kuinka organisaation kyvykkyyksiä voidaan mitata engineering- ja konsultointialalla käyttämällä ns. kyvykkyysauditointimenetelmää. Päämotiivit aineettoman omaisuuden mittaamiseksi tunnistettiin kirjallisuuskatsauksen pohjalta. Erilaisten menetelmien etuja ja haittoja tutkittiin, jotta kyvykkyysauditoinnin suorittamiseen liittyvät haasteet ja vaatimukset tulisivat tunnistetuiksi. Kyvykkyysauditoinnin rakentaminen vaati teollisuudenalan erityispiirteiden tunnistamista. Niiksi havaittiin tietointensiivisyys ja projektikeskeisyys. Auditoinnin implementaatioprosessi koostui neljästä osasta, joista kolmen ensimmäisen suorittamiseen case-yritys antoi merkittävän panoksensa. Kriittisten menestystekijöiden selvittämisen jälkeen voitiin niihin vaikuttavat organisaation kyvykkyydet tunnistaa ja arviointi suorittaa. Arvioinnit kerättiin sisäisiltä ja ulkoisilta arvioijilta, ja ne muodostivat pohjan analyysille, joka selvitti yrityksen kehittämistarpeita. Kyvykkyysauditoinnin hyödyiksi laskettiin kasvanut tietämys yrityksen vahvuuksista ja heikkouksista sekä mahdollisuus tarkkailla säännöllisesti sen kokonaissuorituskykyä ja parantaa sitä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, we examined seawater biofiltration in terms of adenosine triphosphate (ATP) and turbidity. A pilot biofilter continuously fed with fresh seawater reduced both turbidity and biological activity measured by ATP. Experiments operated with an empty bed contact time (EBCT) of between 2 and 14 min resulted in cellular ATP removals of 32% to 60% and turbidity removals of 38% to 75%. Analysis of the water from backwashing the biofilter revealed that the first half of the biofilter concentrated around 80% of the active biomass and colloidal material that produces turbidity. By reducing the EBCT, the biological activity moved from the first part of the biofilter to the end. Balances of cellular ATP and turbidity between consecutive backwashings indicated that the biological activity generated in the biofilter represented more than 90% of the detached cellular ATP. In contrast, the trapped ATP was less than 10% of the overall cellular ATP detached during the backwashing process. Furthermore, the biological activity generated in the biofilter seemed to be more dependent on the elapsed time than the volume filtered. In contrast, the turbidity trapped in the biofilter was proportional to the volume filtered, although a slightly higher amount of turbidity was found in the backwashing water; this was probably due to attrition of the bed medium. Finally, no correlations were found between turbidity and ATP, indicating that the two parameters focus on different matter. This suggests that turbidity should not be used as an alternative to cellular concentration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to improve the efficacy and safety of treatments, drug dosage needs to be adjusted to the actual needs of each patient in a truly personalized medicine approach. Key for widespread dosage adjustment is the availability of point-of-care devices able to measure plasma drug concentration in a simple, automated, and cost-effective fashion. In the present work, we introduce and test a portable, palm-sized transmission-localized surface plasmon resonance (T-LSPR) setup, comprised of off-the-shelf components and coupled with DNA-based aptamers specific to the antibiotic tobramycin (467 Da). The core of the T-LSPR setup are aptamer-functionalized gold nanoislands (NIs) deposited on a glass slide covered with fluorine-doped tin oxide (FTO), which acts as a biosensor. The gold NIs exhibit localized plasmon resonance in the visible range matching the sensitivity of the complementary metal oxide semiconductor (CMOS) image sensor employed as a light detector. The combination of gold NIs on the FTO substrate, causing NIs size and pattern irregularity, might reduce the overall sensitivity but confers extremely high stability in high-ionic solutions, allowing it to withstand numerous regeneration cycles without sensing losses. With this rather simple T-LSPR setup, we show real-time label-free detection of tobramycin in buffer, measuring concentrations down to 0.5 μM. We determined an affinity constant of the aptamer-tobramycin pair consistent with the value obtained using a commercial propagating-wave based SPR. Moreover, our label-free system can detect tobramycin in filtered undiluted blood serum, measuring concentrations down to 10 μM with a theoretical detection limit of 3.4 μM. While the association signal of tobramycin onto the aptamer is masked by the serum injection, the quantification of the captured tobramycin is possible during the dissociation phase and leads to a linear calibration curve for the concentrations over the tested range (10-80 μM). The plasmon shift following surface binding is calculated in terms of both plasmon peak location and hue, with the latter allowing faster data elaboration and real-time display of the results. The presented T-LSPR system shows for the first time label-free direct detection and quantification of a small molecule in the complex matrix of filtered undiluted blood serum. Its uncomplicated construction and compact size, together with the remarkable performances, represent a leap forward toward effective point-of-care devices for therapeutic drug concentration monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background In an agreement assay, it is of interest to evaluate the degree of agreement between the different methods (devices, instruments or observers) used to measure the same characteristic. We propose in this study a technical simplification for inference about the total deviation index (TDI) estimate to assess agreement between two devices of normally-distributed measurements and describe its utility to evaluate inter- and intra-rater agreement if more than one reading per subject is available for each device. Methods We propose to estimate the TDI by constructing a probability interval of the difference in paired measurements between devices, and thereafter, we derive a tolerance interval (TI) procedure as a natural way to make inferences about probability limit estimates. We also describe how the proposed method can be used to compute bounds of the coverage probability. Results The approach is illustrated in a real case example where the agreement between two instruments, a handle mercury sphygmomanometer device and an OMRON 711 automatic device, is assessed in a sample of 384 subjects where measures of systolic blood pressure were taken twice by each device. A simulation study procedure is implemented to evaluate and compare the accuracy of the approach to two already established methods, showing that the TI approximation produces accurate empirical confidence levels which are reasonably close to the nominal confidence level. Conclusions The method proposed is straightforward since the TDI estimate is derived directly from a probability interval of a normally-distributed variable in its original scale, without further transformations. Thereafter, a natural way of making inferences about this estimate is to derive the appropriate TI. Constructions of TI based on normal populations are implemented in most standard statistical packages, thus making it simpler for any practitioner to implement our proposal to assess agreement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn tarkoituksena oli selvittää Alstom Finland Oy:n pääasiakkaiden ympäristö-lupatilanne sekä tarkastella, miten Alstomin toimittamat hiukkastenpuhdistuslait-teet täyttävät muuttavat lainsäädännön vaatimukset. Lisäksi työssä arvioitiin lai-tosten hiukkaspäästöjen vähentämisestä syntyvää savukaasunpuhdistuslaitteiden investointitarvetta. Työn teoriaosuus sisältää katsauksen ympäristölupakäytäntöön sekä Valtioneu-voston asetuksiin, jotka koskevat laitosten hiukkaspäästöjä. Lisäksi työssä on kä-sitelty parhaan käytettävissä olevan tekniikan mukaisia hiukkaspäästörajoja ja tekniikoita sekä hiukkasten muodostumista että raskasmetallien sitoutumista hiukkasiin. Kaikkiaan työssä mukana olevia laitoksia oli 49, joista tarkemmin tarkasteltiin 12 laitosta. Suurin osa laitoksista ei ollut saanut tai hakenut ympäristönsuojelulain mukaista ympäristölupaa, joten niillä on velvollisuus hakea lupaa siirtymäsään-nöksen mukaisesti vuoden 2004 loppuun mennessä. Tarkemmassa tarkastelussa olevien laitosten hiukkaspäästömittaustuloksia vertailtiin nykyisiin sekä uu-siin/oletettuihin ympäristölupien hiukkaspäästörajoihin. Tarkastelussa mukana olevasta seitsemästä soodakattilalaitoksesta, joilla ei vielä ollut uutta ympäristölu-paa, 43 % ylitti arvioidun uuden luparajan 50 mg/m3(n):ssa ja kolmesta meesauu-nia käyttävästä laitoksesta yksi sekä viidestä muusta kattilasta kaksi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diplomityössä päivitetään voimalaitoksen ympäristöntarkkailusuunnitelma vastaamaan uudistuneen ympäristöluvan ja lainsäädännön edellytyksiä. Työssä tutkitaan leijupetikatti-loiden tulipesän lämpötiloja, savukaasun viipymäaikoja tulipesässä, leijukerroskattiloiden päästöjä, päästöjen jatkuvatoimista mittaamista sekä päästöjen seurantaa ja raportointia. Tulipesän lämpötiloja mitattiin kupla- ja kiertoleijukattiloilla. Tuloksien perusteella havait-tiin kiertoleijukattilan tulipesän alaosan lämpötilojen olevan lähes riippumaton pedin lämpötilasta ja höyrykuormasta. Tulipesän yläosassa lämpötilat nousevat höyrykuorman kasvaessa, mutta pedin lämpötilalla ei havaittu vaikutusta tulipesän yläosassakaan. Molemmilla kattiloilla havaittiin voimakas vaakatasoinen lämpötilaprofiili. Kuplaleijukattilalla sekä höyrykuorma että pedin lämpötila vaikuttivat tulipesän lämpötilaan. Savukaasun teoreettiset viipymäajat laskettiin kiertoleijukattilalle. Laskelmien ja mittauksien perusteella havaittiin kattilalla mahdollisuus saavuttaa savukaasun kahden sekunnin viipymäaika 850 ºC lämpötilassa. Kattilan käyttäytymisen aukottomaksi selvittämiseksi kaikilla polttoaineseoksilla ja höyrykuormilla tarvitaan lisää toimenpiteitä kattilalla ja lisää tulipesän lämpötilamittauksia. Leijukerroskattiloiden päästöjen syntymistä ja hallintaa tutkittiin teoreettisesti kirjallisuustutkimuksena. Tutkittuihin päästöihin kuuluivat typen oksidit, rikkidioksidi, hiukkaset, hiilimonoksidi, orgaaninen kokonaishiili, suolahappo, fluorivety, raskasmetallit sekä dioksiinit ja furaanit. Jatkuvatoimisten päästömittausmittauslaitteiden toimintaperiaatteita selvitettiin kirjalli-suustutkimuksena. Samoin selvitettiin jatkuvatoimisten päästömittauslaitteiden virhelähtei-tä. Päästömittauslaitteille laadittiin pitkän ja lyhyen ajan laadunvarmistussuunnitelma. Ha-vaittiin, että nykyiset jatkuvatoimiset päästömittauslaitteet eivät täytä kaikkia uusia laatu-kriteereitä. Päästöjen jatkuvatoimiseen seuraamiseen työssä suunniteltiin uusi valvomonäyttö. Uuden näytön avulla tehostetaan päästöjen valvontaa. Päästöjen raportointiin työssä suunniteltiin vuorokausiraportti. Raporttiin kerätään jatkuva-toimisten päästömittauslaitteiden puolen tunnin keskiarvot. Raportin tarkastaa, allekirjoittaa ja arkistoi vuorossa oleva operaattori.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The subject of this master’s thesis was developing a context-based reminder service for mobile devices. Possible sources of context were identified and analyzed. One such source is geographical location obtained via a GPS receiver. These receivers consume a lot of power and techniques and algorithms for reducing power consumptions were proposed and analyzed. The service was implemented as an application on a series 60 mobile phone. The application requirements, user interface and architecture are presented. The end-user experiences are discussed and possible future development and research areas are presented.