958 resultados para Goodenough’s human figure test


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chromosomal microarray (CMA) is increasingly utilized for genetic testing of individuals with unexplained developmental delay/intellectual disability (DD/ID), autism spectrum disorders (ASD), or multiple congenital anomalies (MCA). Performing CMA and G-banded karyotyping on every patient substantially increases the total cost of genetic testing. The International Standard Cytogenomic Array (ISCA) Consortium held two international workshops and conducted a literature review of 33 studies, including 21,698 patients tested by CMA. We provide an evidence-based summary of clinical cytogenetic testing comparing CMA to G-banded karyotyping with respect to technical advantages and limitations, diagnostic yield for various types of chromosomal aberrations, and issues that affect test interpretation. CMA offers a much higher diagnostic yield (15%-20%) for genetic testing of individuals with unexplained DD/ID, ASD, or MCA than a G-banded karyotype (similar to 3%, excluding Down syndrome and other recognizable chromosomal syndromes), primarily because of its higher sensitivity for submicroscopic deletions and duplications. Truly balanced rearrangements and low-level mosaicism are generally not detectable by arrays, but these are relatively infrequent causes of abnormal phenotypes in this population (<1%). Available evidence strongly supports the use of CMA in place of G-banded karyotyping as the first-tier cytogenetic diagnostic test for patients with DD/ID, ASD, or MCA. G-banded karyotype analysis should be reserved for patients with obvious chromosomal syndromes (e.g., Down syndrome), a family history of chromosomal rearrangement, or a history of multiple miscarriages.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid, sensitive and specific method for quantifying ciprofibrate in human plasma using bezafibrate as the internal standard (IS) is described. The sample was acidified prior extraction with formic acid (88%). The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (diethyl ether/dichloromethane 70/30 (v/v)). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS/MS). Chromatography was performed using Genesis C18 4 mu m analytical column (4.6 x 150 mm i.d.) and a mobile phase consisting of acetonitrile/water (70/30, v/v) and 1 mM acetic acid. The method had a chromatographic run time of 3.4 min and a linear calibration curve over the range 0.1-60 mu g/mL (r > 0.99). The limit of quantification was 0.1 mu g/mL. The intra- and interday accuracy and precision values of the assay were less than 13.5%. The stability tests indicated no significant degradation. The recovery of ciprofibrate was 81.2%, 73.3% and 76.2% for the 0.3, 5.0 and 48.0 ng/mL standard concentrations, respectively. For ciprofibrate, the optimized parameters of the declustering potential, collision energy and collision exit potential were -51 V, -16 eV and -5 V, respectively. The method was also validated without the use of the internal standard. This HPLC-MS/MS procedure was used to assess the bioequivalence of two ciprofibrate 100 mg tablet formulations in healthy volunteers of both sexes. The following pharmacokinetic parameters were obtained from the ciprofibrate plasma concentration vs. time curves: AUC(last), AUC(0-168 h), C(max) and T(max). The geometric mean with corresponding 90% confidence interval (CI) for test/reference percent ratios were 93.80% (90% CI = 88.16-99.79%) for C(max), 98.31% (90% CI = 94.91-101.83%) for AUC(last) and 97.67% (90% CI = 94.45-101.01%) for AUC(0-168 h). Since the 90% Cl for AUC(last), AUC(0-168 h) and C(max) ratios were within the 80-125% interval proposed by the US FDA, it was concluded that ciprofibrate (Lipless (R) 100 mg tablet) formulation manufactured by Biolab Sanus Farmaceutica Ltda. is bioequivalent to the Oroxadin (R) (100 mg tablet) formulation for both the rate and the extent of absorption. (C) 2011 Published by Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Differences in the prevalence of human herpesvirus 8 (HHV-8) and Kaposi`s sarcoma (KS) have been described, depending on the study population and their geographic origin. A cross-sectional study aimed at detecting the frequency and titers of antibodies against HHV-8 latent and lytic antigens in serum samples from individuals with different risk-factors for HHV-8 infection, as well as predictive marker identification in patients with KS, was conducted. Serum samples were collected from seven groups of individuals: 75 patients with AIDS-KS, 5 with classic KS, 16 with African KS, 495 with HIV/AIDS, 805 patients with chronic kidney disease, 683 handicapped individuals, and 757 health care workers. Samples were evaluated for the presence and titers of HHV-8-specific antibodies to latent and lytic antigens using ""in house"" immunofluorescence assays. The results were analyzed by the Chi-square, Fisher`s exact test, Kruskal-Wallis and/or Mann-Whitney U-tests. The frequencies of HHV-8 antibodies were as follows: 87.5-100% in patients with KS, 20.4% in patients with HIV/AIDS, 18% in patients with chronic kidney disease, 1.6% in handicapped individuals, and 1.1% in health care workers. A greater number of samples were antibody positive to lytic antigens. Elevated titers of antibodies to latent and lytic antigens, mostly among patients with KS, were detected. Using established serological assays, different ""at-risk"" populations for HHV-8 infection/disease were detected in this geographic area, confirming HIV/AIDS and identifying patients with chronic kidney disease as high-risk groups. It is suggested that a longitudinal evaluation of antibody titers in patients with chronic kidney disease be undertaken to confirm their predictive value in the development of KS. J. Med. Virol. 81: 1292-1297, 2009. (C) 2009 Wiley-Liss, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the bioequivalence of three ibuprofen formulations (Test formulation: ibuprofen (400 mg capsule) manufactured by Cardinal Health Brasil 402 Ltda. (Sorocaba, Brazil) and licensed to Boehringer Ingelheim do Brasil Quim. e Farm. Ltda. (Sao Paulo, Brazil); Reference formulation (1): ibuprofen (Advil (R); 2 x 200 mg coated tablet) from Wyeth-Whitehall Ltda. (Itapevi, Brazil); Reference formulation (2): ibuprofen (Alivium (R); 8 ml x 50 mg/ml solution) from Schering Plough S.A. (Rio de Janeiro, Brazil)) in 24 healthy volunteers of both sexes. Methods: The study was conducted using an open, randomized, three-period crossover design with at least 5-day washout interval. Plasma samples were obtained over a 24-h period. Plasma ibuprofen concentrations were analyzed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) with negative ion electrospray ionization using multiple reaction monitoring (MRM). The following pharmacokinetic parameters were obtained from the ibuprofen plasma concentration vs. time curves: AUC(last), AUC(trunctmax) AUC(inf) and C-max. Results: The limit of quantification for ibuprofen was 0.1 mu g x ml(-1). The geometric mean with corresponding 90% confidence interval (CI) for Test/Reference (1) percent ratios were 114.24% (90% CI = 105.67, 123.50%) for C-max, 98.97% (90% CI = 94.69, 103.44%) for AUC(last) and 99.40% (90% CI = 95.21, 103.78%) for AUCinf. The geometric mean and respective 90% confidence interval (CI) for Test/Reference (2) percent ratios were 108.38% (90% Cl = 100.195, 117.25%) for C-max, 100.79% (90% CI = 96.39, 105.40%) for AUC(last) and 101.26% (90% CI = 96.94, 105.77%) for AUC(inf); t(max) for the 400 mg Test capsule was shorter than that for the 2 x 200 mg Reference (1) tablets (p < 0.002). Conclusion: Since the 90% CI for AUC(last), AUC(inf) and C-max ratios were within the 80 - 125% interval proposed by the US FDA, it was concluded that ibuprofen formulation manufactured by Cardinal Health Brasil 402 Ltda. and licensed to Boehringer Ingelheim do Brasil Quim. e Farm. Ltda. is bioequivalent to the Advil (R) and Alivium (R) formulations with regard to both the rate and the extent of absorption.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Organotellurium(]V) compounds have been reported to have multiple biological activities including cysteine protease-inhibitory activity, mainly cathepsin B. As cathepsin B is a highly predictive indicator for prognosis and diagnosis of cancer, a possible antitumor potential for these new compounds is expected. In this work, it was investigated the effectiveness of organotellurium(IV) RT-04 to produce lethal effects in the human promyelocytic leukaemia cell line HL60. Using the MTT tetrazolium reduction test, and trypan blue exclusion assay, the IC50 for the compound after 24 h incubation was 6.8 and 0.35 mu M, respectively. Moreover, the compound was found to trigger apoptosis in HL60 cells, inducing DNA fragmentation and caspase-3, -6, and -9 activations. The apoptsosis-induced by RT-04 is probably related to the diminished Bcl-2 expression, observed by RT-PCR, in HL60-treated cells. In vivo studies demonstrated that the RT-04 treatment (2.76 mg/kg given for three consecutive days) produces no significant toxic effects for bone marrow and spleen CFU-GM. However, higher doses (5.0 and 10 mg/kg) produced a dose-dependent reduction in the number of CFU-GM of RT-04-treated mice. These results suggest that RT-04 is able to induce apoptosis in HL60 cells by Bcl-2 expression down-modulation. Further studies are necessary to better clarify the effects of this compound on bone marrow normal cells. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

DANTAS, Rodrigo Assis Neves; NÓBREGA, Walkíria Gomes da; MORAIS FILHO, Luiz Alves; MACÊDO, Eurides Araújo Bezerra de ; FONSECA , Patrícia de Cássia Bezerra; ENDERS, Bertha Cruz; MENEZES, Rejane Maria Paiva de; TORRES , Gilson de Vasconcelos. Paradigms in health care and its relationship to the nursing theories: an analytical test . Revista de Enfermagem UFPE on line. v.4,n.2, p.16-24.abr/jun. 2010. Disponível em < http://www.ufpe.br/revistaenfermagem/index.php/revista>.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present study we evaluated the precision of the ELISA method to quantify caffeine in human plasma and compared the results with those obtained by gas chromatography. A total of 58 samples were analyzed by gas chromatography using a nitrogen-phosphorus detector and routine techniques. For the ELISA test, the samples were diluted to obtain a concentration corresponding to 50% of the absorbance of the standard curve. To determine whether the proximity between the I50 of the standard curve and that of the sample would bring about a more precise result, the samples were divided into three blocks according to the criterion of difference, in modulus, of the I50 of the standard curve and of the I50 of the sample. The samples were classified into three groups. The first was composed of 20 samples with I50 up to 1.5 ng/ml, the second consisted of 21 samples with I50 ranging from 1.51 to 3 ng/ml, and the third of 17 samples with I50 ranging from 3.01 to 13 ng/ml. The determination coefficient (R² = 0.999) showed that the data obtained by gas chromatography represented a reliable basis. The results obtained by ELISA were also reliable, with an estimated Pearson correlation coefficient of 0.82 between the two methods. This coefficient for the different groups (0.88, 0.79 and 0.49 for groups 1, 2 and 3, respectively) showed greater reliability for the test with dilutions closer to I50.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Considering that counting the percentage of CD4 T lymphocytes can add prognostic information regarding patients infected with HIV, the aim of this study was to evaluate the percentage values of CD4+ T lymphocytes from 81 patients determined by flow cytometry and estimated by flow cytometry in conjunction with a hematology counter. Means were compared through the Student's t-test. Pearson's correlation was determined, and the agreement between results was tested by Bland-Altman. The level of significance was P < 0.05. It was found a significantly higher mean difference between the relative values of CD4+ T lymphocytes to the hematologic counter (P < 0.05), for all strata studied. Positive and significant correlations (P < 0.01) were found between the strata CD4 < 200 cells/mL (r = 0.93), between 200 and 500 cells/mL (r = 0.65), and >500 cells/mL (r = 0.81). The limits of agreement were 1.0 +/- 3.8% for the stratum of CD4 < 200 cells/mL, approximately 2.2 +/- 13.5% for the stratum of CD4 between 200 and 500 cells/mL, and approximately 6.2 +/- 20.4% for the stratum > 500 cells/mL. The differences in the percentages of CD4+ T lymphocytes obtained by different methodologies could lead to conflict when used in clinical decisions related to the treatment and care of people infected with HIV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Epidemiological studies have provided evidence that high consumption of tomatoes effectively reduces the risk of reactive oxygen species (ROS)-mediated diseases such as cancer. Tomatoes are rich sources of lycopene, a potent singlet oxygen-quenching carotenoid. In addition to its antioxidant properties, lycopene shows an array of biological effects including antimutagenic and anticarcinogenic activities. In the present study, the chemopreventive action of lycopene was examined on DNA damage and clastogenic or aneugenic effects of H2O2 and n-nitrosodiethylamine (DEN) in the metabolically competent human hepatoma cell line (HepG2 cells). Lycopene at concentrations of 10. 25, and 50 mu M, was tested under three protocols: before, simultaneously, and after treatment with the mutagen, using the comet and micronucleus assays. Lycopene significantly reduced the genotoxicity and mutagenicity of H2O2 in all of the conditions tested. For DEN, significant reductions of primary DNA damage (comet assay) were detected when the carotenoid (all of the doses) was added in the cell culture medium before or simultaneously with the mutagen. In the micronucleus test, the protective effect of lycopene was observed only when added prior to DEN treatment. In conclusion, our results suggest that lycopene is a suitable agent for preventing chemically-induced DNA and chromosome damage. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Taking into consideration that DNA damage plays an important role in carcinogenesis, the purpose of this study was to evaluate whether some radiopacifiers widely used in clinical practice are able to induce genetic damage in primary human cells in vitro. Human peripheral lymphocytes obtained from 10 healthy volunteers were exposed to barium sulphate (BaSO(4)), zirconium oxide (ZnO(2)) and bismuth oxide (Bi(2)O(3)) at final concentrations ranging from 1 to 1000 mu g/mL for 1 h at 37 degrees C. The negative control group was treated with vehicle control (phosphate buffer solution) for 1 h at 37 degrees C and the positive control group was treated with hydrogen peroxide (at 100 mu M) for 5 min on ice. Results were analyzed by the Friedman non-parametric test. The results pointed all compounds tested out did not induce DNA breakage in human peripheral lymphocytes as depicted by the mean tail moment and tail intensity in all concentrations tested. In summary, our results indicate that exposure to these radiopacifiers may not be a factor that increases the level of DNA lesions in human peripheral lymphocytes as detected by single cell gel (comet) assay.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUÇÃO: Leptospirose é uma zoonose que tem como hospedeiros primários os animais silvestres, sinantrópicos e domésticos. Os humanos comportam-se como hospedeiros terminais e acidentais. Sua prevalência depende dos animais portadores que disseminam o agente, de sua sobrevivência ambiental e do contato de pessoas susceptíveis. Cada sorovar tem um ou mais hospedeiros com diferentes níveis de adaptação. Os focos de leptospirose devem-se aos animais infectados, doentes e assintomáticos, considerados como fontes de infecção ambiental. O objetivo deste estudo foi determinar áreas de risco da infecção leptospírica em cães errantes e pacientes com diagnóstico de leptospirose nos anos de 2006 a 2008, em Maringá, Estado do Paraná, Brasil. MÉTODOS: Foram estudados 335 cães errantes e 25 pacientes. Os soros, tanto dos animais como dos pacientes, foram examinados pela prova de soroaglutinação microscópica (SAM), para pesquisa de anticorpos antileptospíricos. Para determinar áreas de risco e a distribuição espacial da doença foram elaborados mapas temáticos. RESULTADOS: Foram observados 41(12,2%) cães positivos para um ou mais sorovares de leptospiras, e os mais frequentes foram: Pyrogenes (43,9%), Canícola (21,9%) e Copennhageni (19,5%). Nos humanos, a positividade foi de 2 (8%) para os sorovares, Pyrogenes e Hardjo Prajitno e, Pyrogenes e Cynopteri. CONCLUSÕES: A análise espacial revelou que o risco de cães e humanos, no município de Maringá, se infectar com leptospiras está presente tanto em áreas centrais como periféricas, fato que reforça a relevância deste estudo e de ações contínuas de vigilância epidemiológica e ambiental para o controle da doença tanto nos animais como no homem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Em agosto de 1983 foram observados 85 habitantes do Município de Humaitá, Estado do Amazonas, Brasil, com a finalidade de estudar a prevalência dos antígenos de HLA -A, -B, -C e DR, dentre os quais 38 eram doentes com malária causada pelo Plasmodium falciparum Todos eles foram examinados para avaliação de esplenomegalia, exame parasitológico de sangue e pesquisa de anticorpos de malária. Foram constituídos três grupos: (I) 25 indivíduos nascidos na região Amazônica que nunca tiveram malária; (II) 38 indivíduos naturais da Amazônia que tinham sido tratados de malária no passado, ou que estavam tendo malária atual, e (III) 22 doentes com malária que contraíram na Amazônia e eram procedentes de outras regiões do Brasil. Foram colhidas amostras de sangue de cada um deles, separados os linfôcitos e os antígenos de HLA foram tipados pelo teste de microlinfocitotoxidade. Houve elevada freqüência de antígenos não identificados, nos grupos estudados, o que sugere ou a existência de homozigoze, oufenôtipo não identificado nessa população. Houve alta freqüência fenotípica de antígeno deAg(W24) (44,7%) no Grupo II, quando comparado ao Grupo 1(32%) ou Grupo III (9%). Os indivíduos do Grupo II mostraram também elevada freqüência do antígeno DR4 (80%) quando comparado ao Grupo 1(36,3%) ou Grupo III(16,6%). Essas observações sugerem a possibilidade de suscetibilidadegenética ã malária entre os nativos da Amazônia e indicam a necessidade da realização de inquéritos mais extensos sobre a freqüência de antígenos de HLA em habitantes de zona endêmica de malária.