970 resultados para microfluidic chip system


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The purpose of this work is to establish the application of a fully automated microfluidic chip based protein separation assay in tear analysis. It is rapid, requires small sample volumes and is vastly superior to, and more convenient than, comparable conventional gel electrophoresis assays. The protein sizing chip technology was applied to three specific fields of analysis. Firstly tear samples were collected regularly from subjects establishing the baseline effects of tear stimulation, tear state and patient health. Secondly tear samples were taken from lens wearing eyes and thirdly the use of microfluidic technology was assessed as a means to investigate a novel area of tear analysis, which we have termed the 'tear envelope'. Utilising the Agilent 2100 Bioanalyzer in combination with the Protein 200 Plus LabChip kit, these studies investigated tear proteins in the range of 14-200 kDa. Particular attention was paid to the relative concentrations of lysozyme, tear lipocalin, secretory IgA (sIgA), IgG and lactoferrin, together with the overall tear electropherogram 'fingerprint'. Furthermore, whilst lens-tear interaction studies are generally thought of as an investigation into the effects of tears components on the contact lens material, i.e. deposition studies, this report addresses the reverse phenomenon-the effect of the lens, and particularly the newly inserted lens, on the tear fluid composition and dynamics. The use of microfluidic technology provides a significant advance in tear studies and should prove invaluable in tear diagnostics and contact lens performance analysis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Multidrug resistance (MDR) occurs in prostate cancer, and this happens when the cancer cells resist chemotherapeutic drugs by pumping them out of the cells. MDR inhibitors such as cyclosporin A (CsA) can stop the pumping and enhance the drugs accumulated in the cells. The cellular drug accumulation is monitored using a microfluidic chip mounted on a single cell bioanalyzer. This equipment has been developed to measure accumulation of drugs such as doxorubicin (DOX) and fluorescently labeled paclitaxel (PTX) in single prostate cancer cells. The inhibition of drug efflux on the same prostate cell was examined in drug-sensitive and drug-resistant cells. Accumulation of these drug molecules was not found in the MDR cells, PC-3 RX-DT2R cells. Enhanced drug accumulation was observed only after treating the MDR cell in the presence of 5 μM of CsA as the MDR inhibitor. We envision this monitoring of the accumulation of fluorescent molecules (drug or fluorescent molecules), if conducted on single patient cancer cells, can provide information for clinical monitoring of patients undergoing chemotherapy in the future.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis presents the development of chip-based technology for informative in vitro cancer diagnostics. In the first part of this thesis, I will present my contribution in the development of a technology called “Nucleic Acid Cell Sorting (NACS)”, based on microarrays composed of nucleic acid encoded peptide major histocompatibility complexes (p/MHC), and the experimental and theoretical methods to detect and analyze secreted proteins from single or few cells.

Secondly, a novel portable platform for imaging of cellular metabolism with radio probes is presented. A microfluidic chip, so called “Radiopharmaceutical Imaging Chip” (RIMChip), combined with a beta-particle imaging camera, is developed to visualize the uptake of radio probes in a small number of cells. Due to its sophisticated design, RIMChip allows robust and user-friendly execution of sensitive and quantitative radio assays. The performance of this platform is validated with adherent and suspension cancer cell lines. This platform is then applied to study the metabolic response of cancer cells under the treatment of drugs. Both cases of mouse lymphoma and human glioblastoma cell lines, the metabolic responses to the drug exposures are observed within a short time (~ 1 hour), and are correlated with the arrest of cell-cycle, or with changes in receptor tyrosine kinase signaling.

The last parts of this thesis present summaries of ongoing projects: development of a new agent as an in vivo imaging probe for c-MET, and quantitative monitoring of glycolytic metabolism of primary glioblastoma cells. To develop a new agent for c-MET imaging, the one-bead-one-compound combinatorial library method is used, coupled with iterative screening. The performance of the agent is quantitatively validated with cell-based fluorescent assays. In the case of monitoring the metabolism of primary glioblastoma cell, by RIMChip, cells were sorting according to their expression levels of oncoprotein, or were treated with different kinds of drugs to study the metabolic heterogeneity of cancer cells or metabolic response of glioblastoma cells to drug treatments, respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

针对目前在纳米器件及传感器的制造中尚无对大量粒子进行有效操纵的方法,我们利用介电泳方法对大量微粒进行定位和传输操纵,介绍了利用MEMS工艺进行介电泳芯片加工的过程以及整个观测与实验系统的建立,通过有限元软件对传统介电泳和行波介电泳中电极阵列的电场分布进行求解,并在该实验系统下实现了对微通道中的悬浮高度和微粒的运动速度的测量.该实验系统的研究为液体环境下微纳颗粒的装配和分离提供了一条有效的技术路径.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this thesis I theoretically study quantum states of ultracold atoms. The majority of the Chapters focus on engineering specific quantum states of single atoms with high fidelity in experimentally realistic systems. In the sixth Chapter, I investigate the stability and dynamics of new multidimensional solitonic states that can be created in inhomogeneous atomic Bose-Einstein condensates. In Chapter three I present two papers in which I demonstrate how the coherent tunnelling by adiabatic passage (CTAP) process can be implemented in an experimentally realistic atom chip system, to coherently transfer the centre-of-mass of a single atom between two spatially distinct magnetic waveguides. In these works I also utilise GPU (Graphics Processing Unit) computing which offers a significant performance increase in the numerical simulation of the Schrödinger equation. In Chapter four I investigate the CTAP process for a linear arrangement of radio frequency traps where the centre-of-mass of both, single atoms and clouds of interacting atoms, can be coherently controlled. In Chapter five I present a theoretical study of adiabatic radio frequency potentials where I use Floquet theory to more accurately model situations where frequencies are close and/or field amplitudes are large. I also show how one can create highly versatile 2D adiabatic radio frequency potentials using multiple radio frequency fields with arbitrary field orientation and demonstrate their utility by simulating the creation of ring vortex solitons. In the sixth Chapter I discuss the stability and dynamics of a family of multidimensional solitonic states created in harmonically confined Bose-Einstein condensates. I demonstrate that these solitonic states have interesting dynamical instabilities, where a continuous collapse and revival of the initial state occurs. Through Bogoliubov analysis, I determine the modes responsible for the observed instabilities of each solitonic state and also extract information related to the time at which instability can be observed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Membranproteine spielen eine wichtige Rolle bei physiologischen Prozessen wie Signalweiterleitung oder Immunreaktion. Deshalb stehen sie im Fokus der pharmakologischen Wirkstoffentwicklung und es besteht großes Interesse, Membranproteinbasierte Biosensoren zu entwickeln, die sich z.B. als Screening-Plattformen eignen. Allerdings stellt die Handhabung von Membranproteinen wegen ihrer amphiphilen Struktur eine große Herausforderung dar. Membranproteine werden meist in Zellkultur oder in bakteriellen Expressionssystemen synthetisiert. Diese Verfahren liefern aber oft nur eine geringe Ausbeute und erlauben wenig Kontrolle über die Expressionsbedingungen. Als alternativer Ansatz bietet sich stattdessen die in vitro Synthese von Proteinen an, die in einer zellfreien Umgebung stattfindet. Ziel der vorliegenden Arbeit war die Etablierung eines miniaturisierten Analysesystems, das Aktivitätsmessungen an in vitro synthetisierten Ionenkanälen erlaubt. Dafür wurde ein Labon- Chip entwickelt, der elektrochemische und optische Nachweismethoden in parallelen Anätzen ermöglicht. Als amphiphile Umgebung für die Inkorporation von Membranproteinen wurden vier verschieden biomimetische Membranaufbauten hinsichtlich ihrer Dichtigkeit und ihrer Reproduzierbarkeit untersucht. Als Methode fanden insbesondere die Impedanzspektroskpie und die Oberflächenplasmonen-Resonanzspektroskopie Anwendung. Die peptide cushioned Bilyer Lipid Membranes (pcBLM) eignete sich dabei am besten für Untersuchungen an Membranproteinen. Zur Detektion der Ionenkanalaktivität wurde eine neue Messmethode etabliert, die auf der Messung der Impedanz bei fester Frequenz basiert und u.a. eine Aussage über die Änderung des Membranwiderstandes bei Aktivierung erlaubt. Am Beispiel des nicotinischen Acetylcholinrezeptors (nAchR) konnte gezeigt werden, dass sich die Aktivität von Ionenkanälen mit dem entwickelten Chip-System nachweisen ließ. Die Spezifität der Methode konnte durch verschiedene Kontrollen wie die Zugabe eines nicht-aktivierenden Liganden oder Inhibition des Rezeptors nachgewiesen werden. Weiterhin konnte die in vitro Synthese des Ionenkanals a7 nAchR durch Radioaktivmarkierung nachgewiesen werden. Die Inkorporation des Rezeptors in die biomimetischen Membranen wurde mit Immunodetektion und elektrochemischen Methoden untersucht. Es zeigte sich, dass die funktionelle Inkorporation des a7 nAchR davon abhing, welcher biomimetische Membranaufbau verwendet wurde.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The three canonical Rho GTPases RhoA, Rac1 and Cdc42 co-ordinate cytoskeletal dynamics. Recent studies indicate that all three Rho GTPases are activated at the leading edge of motile fibroblasts, where their activity fluctuates at subminute time and micrometer length scales. Here, we use a microfluidic chip to acutely manipulate fibroblast edge dynamics by applying pulses of platelet-derived growth factor (PDGF) or the Rho kinase inhibitor Y-27632 (which lowers contractility). This induces acute and robust membrane protrusion and retraction events, that exhibit stereotyped cytoskeletal dynamics, allowing us to fairly compare specific morphodynamic states across experiments. Using a novel Cdc42, as well as previously described, second generation RhoA and Rac1 biosensors, we observe distinct spatio-temporal signaling programs that involve all three Rho GTPases, during protrusion/retraction edge dynamics. Our results suggest that Rac1, Cdc42 and RhoA regulate different cytoskeletal and adhesion processes to fine tune the highly plastic edge protrusion/retraction dynamics that power cell motility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Due to increasing integration density and operating frequency of today's high performance processors, the temperature of a typical chip can easily exceed 100 degrees Celsius. However, the runtime thermal state of a chip is very hard to predict and manage due to the random nature in computing workloads, as well as the process, voltage and ambient temperature variability (together called PVT variability). The uneven nature (both in time and space) of the heat dissipation of the chip could lead to severe reliability issues and error-prone chip behavior (e.g. timing errors). Many dynamic power/thermal management techniques have been proposed to address this issue such as dynamic voltage and frequency scaling (DVFS), clock gating and etc. However, most of such techniques require accurate knowledge of the runtime thermal state of the chip to make efficient and effective control decisions. In this work we address the problem of tracking and managing the temperature of microprocessors which include the following sub-problems: (1) how to design an efficient sensor-based thermal tracking system on a given design that could provide accurate real-time temperature feedback; (2) what statistical techniques could be used to estimate the full-chip thermal profile based on very limited (and possibly noise-corrupted) sensor observations; (3) how do we adapt to changes in the underlying system's behavior, since such changes could impact the accuracy of our thermal estimation. The thermal tracking methodology proposed in this work is enabled by on-chip sensors which are already implemented in many modern processors. We first investigate the underlying relationship between heat distribution and power consumption, then we introduce an accurate thermal model for the chip system. Based on this model, we characterize the temperature correlation that exists among different chip modules and explore statistical approaches (such as those based on Kalman filter) that could utilize such correlation to estimate the accurate chip-level thermal profiles in real time. Such estimation is performed based on limited sensor information because sensors are usually resource constrained and noise-corrupted. We also took a further step to extend the standard Kalman filter approach to account for (1) nonlinear effects such as leakage-temperature interdependency and (2) varying statistical characteristics in the underlying system model. The proposed thermal tracking infrastructure and estimation algorithms could consistently generate accurate thermal estimates even when the system is switching among workloads that have very distinct characteristics. Through experiments, our approaches have demonstrated promising results with much higher accuracy compared to existing approaches. Such results can be used to ensure thermal reliability and improve the effectiveness of dynamic thermal management techniques.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Microfluidic systems have become competitive tools in the invitro modelling of diseases and promising alternatives to animal studies. They allow obtaining more invivo like conditions for cellular assays. Research in idiopathic pulmonary fibrosis could benefit from this novel methodological approach to understand the pathophysiology of the disease & develop efficient therapies. The use of hepatocyte growth factor (HGF) for alveolar reepithelisation is a promising approach. In this study, we show a new microfluidic system to analyse the effects of HGF on injured alveolar epithelial cells. Microfluidic systems in polydimethylsiloxane were fabricated by soft lithography. The alveolar A549 epithelial cells (10,000 cells) were seeded and studied in these microfluidic systems with media perfusion (1μl/30min). Injury tests were made on the cells by the perfusion with media containing H2O2 or bleomycin. The degree of injury was then assessed by a metabolic and an apoptotic assays. Wound assays were also performed with a central laminar flow of trypsin. Monitoring of wound closure with HGF vs control media was assessed. The alveolar A549 epithelial cells grew and proliferated in the microfluidic system. In the wound closure assay, the degree of wound closure after 5 hours was (53.3±1.3%) with HGF compared to (9.8±2.4%) without HGF (P <0.001). We present a novel microfluidic model that allows culture, injury and wounding of A549 epithelial cells and represents the first step towards the development of an invitro reconstitution of the alveolar-capillary interface. We were also able to confirm that HGF increased alveolar epithelial repair in this system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Microfluidics system are novel tools to study cell-cell interactions in vitro. This project focuses on the development of a new microfluidic device to co-culture alveolar epithelial cells and mesenchymal stem cells to study cellular interactions involved in healing the injured alveolar epithelium. Methods: Microfluidic systems in polydimethylsiloxane were fabricated by soft lithography. The alveolar A549 epithelial cells were seeded and injury tests were made on the cells by perfusion with media containing H2O2 or bleomycin during 6 or 18hrs. Rat Bone marrow derived stromal cells (BMSC) were then introduced into the system and cell-cell interaction was studied over 24 hrs. Results: A successful co-culture of A549 alveolar epithelial cells and BMS was achieved in the microfluidic system. The seeded alveolar epithelial cells and BMSC adhered to the bottom surface of the microfluidic device and proliferated under constant perfusion. Epithelial injury to mimic mechanisms seen in idiopathic pulmonary fibrosis was induced in the microchannels by perfusing with H2O2 or bleomycin. Migration of BMSC towards the injured epithelium was observed as well as cell-cell interaction between the two cell types was also seen. Conclusion: We demonstrate a novel microfluidic device aimed at showing interactions between different cell types on the basis of a changing microenvironment. Also we were able to confirm interaction between injured alvolar epithelium and BMSC, and showed that BMSC try to heal the injured epitelium.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Tumors are heterogeneous masses of cells characterized pathologically by their size and spread. Their chaotic biology makes treatment of malignancies hard to generalize. We present a robust and reproducible glass microfluidic system, for the maintenance and “interrogation” of head and neck squamous cell carcinoma (HNSCC) tumor biopsies, which enables continuous media perfusion and waste removal, recreating in vivo laminar flow and diffusion-driven conditions. Primary HNSCC or metastatic lymph samples were subsequently treated with 5-fluorouracil and cisplatin, alone and in combination, and were monitored for viability and apoptotic biomarker release ‘off-chip’ over 7 days. The concentration of lactate dehydrogenase was initially high but rapidly dropped to minimally detectable levels in all tumor samples; conversely, effluent concentration of WST-1 (cell proliferation) increased over 7 days: both factors demonstrating cell viability. Addition of cell lysis reagent resulted in increased cell death and reduction in cell proliferation. An apoptotic biomarker, cytochrome c, was analyzed and all the treated samples showed higher levels than the control, with the combination therapy showing the greatest effect. Hematoxylin- and Eosin-stained sections from the biopsy, before and after maintenance, demonstrated the preservation of tissue architecture. This device offers a novel method of studying the tumor environment, and offers a pre-clinical model for creating personalized treatment regimens.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

 Cardiovascular diseases are the most prevalent medical conditions affecting the modern world, reducing the quality of life for those affected and causing an ever increasing burden on clinical resources. Cardiac biomarkers are crucial in the diagnosis and management of patient outcomes. In that respect, such proteins are desirable to be measured at the point of care, overcoming the shortcomings of current instrumentation. We present a CO2 laser engraving technique for the rapid prototyping of a polymeric autonomous capillary system with embedded on-chip planar lenses and biosensing elements, the first step towards a fully miniaturised and integrated cardiac biosensing platform. The system has been applied to the detection of cardiac Troponin I, the gold standard biomarker for the diagnosis of acute myocardial infarction. The devised lab-on-a-chip device was demonstrated to have 24 pg/ml limit of detection, which is well within the minimum threshold for clinically applicable concentrations. Assays were completed within approximately 7–9 min. Initial results suggest that, given the portability, low power consumption and high sensitivity of the device, this technology could be developed further into point of care instrumentation useful in the diagnosis of various forms of cardiovascular diseases. 2014 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We describe a System-C based framework we are developing, to explore the impact of various architectural and microarchitectural level parameters of the on-chip interconnection network elements on its power and performance. The framework enables one to choose from a variety of architectural options like topology, routing policy, etc., as well as allows experimentation with various microarchitectural options for the individual links like length, wire width, pitch, pipelining, supply voltage and frequency. The framework also supports a flexible traffic generation and communication model. We provide preliminary results of using this framework to study the power, latency and throughput of a 4x4 multi-core processing array using mesh, torus and folded torus, for two different communication patterns of dense and sparse linear algebra. The traffic consists of both Request-Response messages (mimicing cache accesses)and One-Way messages. We find that the average latency can be reduced by increasing the pipeline depth, as it enables higher link frequencies. We also find that there exists an optimum degree of pipelining which minimizes energy-delay product.