985 resultados para femoral nerve block


Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVES The importance of phrenic nerve preservation during pneumonectomy remains controversial. We previously demonstrated that preservation of the phrenic nerve in the immediate postoperative period preserved lung function by 3-5% but little is known about its long-term effects. We, therefore, decided to investigate the effect of temporary ipsilateral cervical phrenic nerve block on dynamic lung volumes in mid- to long-term pneumonectomy patients. METHODS We investigated 14 patients after a median of 9 years post pneumonectomy (range: 1-15 years). Lung function testing (spirometry) and fluoroscopic and/or sonographic assessment of diaphragmatic motion on the pneumonectomy side were performed before and after ultrasonographic-guided ipsilateral cervical phrenic nerve block by infiltration with lidocaine. RESULTS Ipsilateral phrenic nerve block was successfully achieved in 12 patients (86%). In the remaining 2 patients, diaphragmatic motion was already paradoxical before the nerve block. We found no significant difference on dynamic lung function values (FEV1 'before' 1.39 ± 0.44 vs FEV1 'after' 1.38 ± 0.40; P = 0.81). CONCLUSIONS Induction of a temporary diaphragmatic palsy did not significantly influence dynamic lung volumes in mid- to long-term pneumonectomy patients, suggesting that preservation of the phrenic nerve is of greater importance in the immediate postoperative period after pneumonectomy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background and objectives: Peripheral nerve blockade requires regional anesthesia skills that are taught in several formats and assessing technical proficiency has shifted from fulfillment of quotas to comprehensive procedural evaluation. Complete analgesia is the clinical endpoint validating successful nerve blockade but patient, technical and procedural factors influence this result. The purpose of this study was to determine if physician trainee or nurse anesthetist administered sciatic nerve blockade influence postoperative pain scores and opioid analgesic requirements and if patient factors, technique and repetition influence this outcome. Method: Sciatic nerve blockade by nerve stimulation and ultrasound based techniques were performed by senior anesthesiology resident trainees and nurse anesthetists under the supervision of regional anesthesia faculty. Preoperative patient characteristics including obesity, trauma, chronic pain, opioid use and preoperative pain scores were recorded and compared to the post-procedure pain scores and opioid analgesic requirements upon discharge from the post-anesthesia care unit and 24 hours following sciatic nerve blockade. Results: 93 patients received sciatic nerve blockade from 22 nurse anesthetists and 21 residents during 36 months. A significant relation between training background and improved pain scores was not demonstrated but transition from nerve stimulation to ultrasound guided techniques lowered immediate opioid usage in all groups. Patients with pre-existing chronic opioid use had higher postoperative pain scores and opioid dosages following nerve block. Conclusion: Patient analgesia should be an integral measure of proficiency in regional anesthesia techniques and evaluating this procedure outcome for all practitioners throughout their training and beyond graduation will longitudinally assess technical expertise.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: Assessment of expertise in regional anesthesia techniques is traditionally based upon quota fulfillment of procedures during training. Validation of practitioner proficiency in performing procedures in surgical specialties has moved from simple measurement of technical skills to evaluation of global patient outcomes. Complete absence of pain as a result of nerve blockade is the most important clinical endpoint but patient, technical and procedural factors influence results. The purpose of this study was to measure the postoperative pain scores and associated analgesic medication requirements for patients administered sciatic nerve blockade by nurse anesthetists and determine patient or procedural factors that influenced this outcome. Methods: Either nerve stimulator or ultrasound guided sciatic nerve blockade was administered by nurse anesthetists under the supervision of regional anesthesia faculty. Patient demographic data that was collected included gender, body mass index, surgical procedure, and pre-existing chronic pain with associated opioid use. Patient self-reported pain scores and opioid analgesic dosages in the preoperative, intraoperative, immediate postoperative and 24 hour post procedure intervals were recorded. Results: 22 nurse anesthetists administered sciatic nerve blockade to 48 patients during a 36 month interval. Transition from a nerve stimulator to ultrasound guided sciatic nerve block technique resulted in lower mean pain scores. Patients reporting chronic opioid use were observed to have elevated perioperative opioid analgesic requirements and pain scores compared to opioid naïve patients. Conclusion: Effective analgesia is a prime measure for assessing expertise in regional anesthesia and continuous evaluation of this outcome in everyday practice is proposed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To investigate the validity of the Trendelenburg test (TT) using an ultrasound-guided nerve block (UNB) of the superior gluteal nerve and determine whether the reduction in hip abductor muscle (HABD) strength would result in the theorized mechanical compensatory strategies measured during the TT. Design: Quasi-experimental. Setting: Hospital. Participants: Convenience sample of 9 healthy men. Only participants with no current or previous injury to the lumbar spine, pelvis, or lower extremities, and no previous surgeries were included. Interventions: Ultrasound-guided nerve block. Main Outcome Measures: Hip abductor muscle strength (percent body weight [%BW]), contralateral pelvic drop (cPD), change in contralateral pelvic drop (Delta cPD), ipsilateral hip adduction, and ipsilateral trunk sway (TRUNK) measured in degrees. Results: The median age and weight of the participants were 31 years (interquartile range [IQR], 22-32 years) and 73 kg (IQR, 67-81 kg), respectively. An average 52% reduction of HABD strength (z = 2.36, P = 0.02) resulted after the UNB. No differences were found in cPD or Delta cPD (z = 0.01, P = 0.99, z = 20.67, P = 0.49, respectively). Individual changes in biomechanics showed no consistency between participants and nonsystematic changes across the group. One participant demonstrated the mechanical compensations described by Trendelenburg. Conclusions: The TT should not be used as a screening measure for HABD strength in populations demonstrating strength greater than 30% BW but should be reserved for use with populations with marked HABD weakness. Clinical Relevance: This study presents data regarding a critical level of HABD strength required to support the pelvis during the TT.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The Trendelenburg Test (TT) is used to assess the functional strength of the hip abductor muscles (HABD), their ability to control frontal plane motion of the pelvis, and the ability of the lumbopelvic complex to transfer load into single leg stance. Rationale: Although a standard method to perform the test has been described for use within clinical populations, no study has directly investigated Trendelenburg’s hypotheses. Purpose: To investigate the validity of the TT using an ultrasound guided nerve block (UNB) of the superior gluteal nerve and determine whether the reduction in HABD strength would result in the theorized mechanical compensatory strategies measured during the TT. Methods: Quasi-experimental design using a convenience sample of nine healthy males. Only subjects with no current or previous injury to the lumbar spine, pelvis, or lower extremities, and no previous surgeries were included. Force dynamometry was used to evaluation HABD strength (%BW). 2D mechanics were used to evaluate contralateral pelvic drop (cMPD), change in contralateral pelvic drop (∆cMPD), ipsilateral hip adduction (iHADD) and ipsilateral trunk sway (TRUNK) measured in degrees (°). All measures were collected prior to and following a UNB on the superior gluteal nerve performed by an interventional radiologist. Results: Subjects’ age was median 31yrs (IQR:22-32yrs); and weight was median 73kg (IQR:67-81kg). An average 52% reduction of HABD strength (z=2.36,p=0.02) resulted following the UNB. No differences were found in cMPD or ∆cMPD (z=0.01,p= 0.99, z=-0.67,p=0.49). Individual changes in biomechanics show no consistency between subjects and non-systematic changes across the group. One subject demonstrated the mechanical compensations described by Trendelenburg. Discussion: The TT should not be used as screening measure for HABD strength in populations demonstrating strength greater than 30%BW but reserved for use with populations with marked HABD weakness. Importance: This study presents data regarding a critical level of HABD strength required to support the pelvis during the TT.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Researchers have postulated that reduced hip-abductor muscle strength may have a role in the progression of knee osteoarthritis by increasing the external knee-adduction moment. However, the relationship between hip-abductor strength and frontal-plane biomechanics remains unclear. To experimentally reduce hip-abduction strength and observe the subsequent changes in frontal-plane biomechanics. Descriptive laboratory study. Research laboratory. Eight healthy, recreationally active men (age = 27 ± 6 years, height = 1.75 ± 0.11 m, mass = 76.1 ± 10.0 kg). All participants underwent a superior gluteal nerve block injection to reduce the force output of the hip-abductor muscle group. Maximal isometric hip-abduction strength and gait biomechanical data were collected before and after the injections. Gait biomechanical variables collected during walking consisted of knee- and hip-adduction moments and impulses and the peak angles of contralateral pelvic drop, hip adduction, and ipsilateral trunk lean. Hip-abduction strength was reduced after the injection (P = .001) and remained lower than baseline values at the completion of the postinjection gait data collection (P = .02). No alterations in hip- or knee-adduction moments (hip: P = .11; knee: P = .52) or impulses (hip: P = .16; knee: P = .41) were found after the nerve block. Similarly, no changes in angular kinematics were observed for contralateral pelvic drop (P = .53), ipsilateral trunk lean (P = .78), or hip adduction (P = .48). A short-term reduction in hip-abductor strength was not associated with alterations in the frontal-plane gait biomechanics of young, healthy men. Further research is needed to determine whether a similar relationship is true in older adults with knee osteoarthritis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis work covered the fabrication and characterisation of impedance sensors for biological applications aiming in particular to the cytotoxicity monitoring of cultured cells exposed to different kind of chemical compounds and drugs and to the identification of different types of biological tissue (fat, muscles, nerves) using a sensor fabricated on the tip of a commercially available needle during peripheral nerve block procedures. Gold impedance electrodes have been successfully fabricated for impedance measurement on cells cultured on the electrode surface which was modified with the fabrication of gold nanopillars. These nanostructures have a height of 60nm or 100nm and they have highly ordered layout as they are fabricated through the e-beam technique. The fabrication of the threedimensional structures on the interdigitated electrodes was supposed to improve the sensitivity of the ECIS (electric cell-substrate impedance sensing) measurement while monitoring the cytotoxicity effects of two different drugs (Antrodia Camphorata extract and Nicotine) on three different cell lines (HeLa, A549 and BALBc 3T3) cultured on the impedance devices and change the morphology of the cells growing on the nanostructured electrodes. The fabrication of the nanostructures was achieved combining techniques like UV lithography, metal lift-off, evaporation and e-beam lithography techniques. The electrodes were packaged using a pressure sensitive, medical grade adhesive double-sided tape. The electrodes were then characterised with the aid of AFM and SEM imaging which confirmed the success of the fabrication processes showing the nanopillars fabricated with the right layout and dimensions figures. The introduction of nanopillars on the impedance electrodes, however, did not improve much the sensitivity of the assay with the exception of tests carried out with Nicotine. HeLa and A549 cells appeared to grow in a different way on the two surfaces, while no differences where noticed on the BALBc 3T3 cells. Impedance measurements obtained with the dead cells on the negative control electrodes or the test electrodes with the drugs can be compared to those done on the electrodes containing just media in the tested volume (as no cells are attached and cover the electrode surface). The impedance figures recorded using these electrodes were between 1.5kΩ and 2.5 kΩ, while the figures recorded on confluent cell layers range between 4kΩ and 5.5kΩ with peaks of almost 7 kΩ if there was more than one layer of cells growing on each other. There was then a very clear separation between the values of living cell compared to the dead ones which was almost 2.5 - 3kΩ. In this way it was very easy to determine whether the drugs affected the cells normal life cycle on not. However, little or no differences were noticed in the impedance analysis carried out on the two different kinds of electrodes using cultured cells. An increase of sensitivity was noticed only in a couple of experiments carried out on A549 cells growing on the nanostructured electrodes and exposed to different concentration of a solution containing Nicotine. More experiments to achieve a higher number of statistical evidences will be needed to prove these findings with an absolute confidence. The smart needle project aimed to reduce the limitations of the Electrical Nerve Stimulation (ENS) and the Ultra Sound Guided peripheral nerve block techniques giving the clinicians an additional tool for performing correctly the peripheral nerve block. Bioimpedance, as measured at the needle tip, provides additional information on needle tip location, thereby facilitating detection of intraneural needle placement. Using the needle as a precision instrument and guidance tool may provide additional information as to needle tip location and enhance safety in regional anaesthesia. In the time analysis, with the frequency fixed at 10kHz and the samples kept at 12°C, the approximate range for muscle bioimpedance was 203 – 616 Ω, the approximate bioimpedance range for fat was 5.02 - 17.8 kΩ and the approximate range for connective tissue was 790 Ω – 1.55 kΩ. While when the samples were heated at 37°C and measured again at 10kHz, the approximate bioimpedance range for muscle was 100-175Ω. The approximate bioimpedance range of fat was 627 Ω - 3.2 kΩ and the range for connective tissue was 221-540Ω. In the experiments done on the fresh slaughtered lamb carcass, replicating a scenario close to the real application, the impedance values recorded for fat were around 17 kΩ, for muscle and lean tissue around 1.3 kΩ while the nervous structures had an impedance value of 2.9 kΩ. With the data collected during this research, it was possible to conclude that measurements of bioimpedance at the needle tip location can give valuable information to the clinicians performing a peripheral nerve block procedure as the separation (in terms of impedance figures) was very marked between the different type of tissues. It is then feasible to use an impedance electrode fabricated on the needle tip to differentiate several tissues from the nerve tissue. Currently, several different methods are being studied to fabricate an impedance electrode on the surface of a commercially available needle used for the peripheral nerve block procedure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dans l’hémiparésie consécutive à un AVC, une coactivation anormale des extenseurs du genou et de la cheville est souvent observée à la jambe atteinte lorsque la personne tente de bouger ou encore lors de la marche. Les mécanismes sous-jacents à cette coactivation sont mal compris. Bien que l’AVC entraîne une lésion supraspinale, des évidences démontrent le dysfonctionnement de certains circuits spinaux dans l’hémiparésie. Ce projet de doctorat visait à évaluer : 1) l’excitabilité des circuits spinaux intersegmentaires projetant des extenseurs du genou aux extenseurs de la cheville et 2) si un éventuel dysfonctionnement de ces circuits dans l’hémiparésie est associé à une coactivation anormale des extenseurs du genou et de la cheville lors de contractions statiques et au cours de la marche. La première étude compare la modulation de l’activité réflexe du soléaire suite à la stimulation du nerf fémoral entre des sujets hémiparétiques et sains. Une augmentation de la facilitation hétéronyme de courte latence et une diminution de l’inhibition ultérieure du réflexe H du soléaire ont été observées chez les sujets hémiparétiques. Ces résultats démontrent un dysfonctionnement des circuits intersegmentaires propriospinaux liant le quadriceps au soléaire suite à l’AVC. La deuxième étude démontre que ces changements dans la modulation hétéronyme des sujets hémiparétiques, évaluée au moyen de la méthode complexe basée sur l’activité réflexe du soléaire, sont similaires à ceux observés lorsque la modulation est évaluée en utilisant une méthode plus simple, soit celle de l’activité volontaire du soléaire. De plus, la modulation hétéronyme évaluée par les deux méthodes est corrélée avec l’atteinte motrice à la jambe parétique. La troisième étude a permis de quantifier une augmentation de la coactivation entre les extenseurs du genou et de la cheville lors de contractions volontaires statiques chez des personnes hémiparétiques par rapport à des personnes saines. De plus, le niveau accru de la coactivation involontaire des extenseurs de la cheville lors de l’activation volontaire des extenseurs du genou s’avère corrélé avec la modulation intersegmentaire du côté parétique. La quatrième étude a utilisé un indice temporel, soit l’intervalle entre les pics d’activation électromyographique (PAI), et un indice d’amplitude de coactivation (CAI) pour quantifier une augmentation de la coactivation entre les extenseurs du genou et de la cheville lors de la marche chez des personnes hémiparétiques par rapport à des personnes saines. Ces indices sont corrélés, pour certains groupes musculaires, avec la modulation intersegmentaire modifiée du côté parétique. Finalement, des résultats préliminaires montrent que la vibration mécanique du tendon rotulien (80 Hz) réduit la facilitation intersegmentaire accrue des sujets hémiparétiques. Ce projet doctoral a permis de mettre en lumière un dysfonctionnement de circuits spinaux liant le quadriceps et le soléaire dans l’hémiparésie consécutive à un AVC. Ce changement dans les mécanismes neurophysiologiques de la moelle épinière est corrélé avec des changements fonctionnels. Ainsi, ce dysfonctionnement pourrait contribuer à la coactivation involontaire entre les extenseurs du genou et de la cheville qui fait partie intégrante de la synergie pathologique en extension souvent rencontrée à la jambe parétique lors d’efforts en statique et pendant la marche. Finalement, une étude préliminaire suggère que la vibration mécanique serait une modalité sensorielle prometteuse pour réguler l’hyperexcitabilité des circuits spinaux qui contribuerait aux atteintes motrices chez les personnes hémiparétiques.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Las cirugías reconstructivas múltiples de miembros inferiores son intervenciones quirúrgicas que implican un difícil manejo analgésico en el postoperatorio, actualmente la técnica analgésica usada es la analgesia peridural; sin embargo los efectos adversos asociados a esta no la hacen una técnica ideal para manejo de dolor. Los bloqueos de nervio periférico han aparecido como una alternativa para el manejo del dolor; pero no se ha difundido ampliamente su uso. Se pretende evaluar la disminución de efectos adversos con el uso de bloqueos de nervio periférico sobre la analgesia epidural. Este estudio piloto inicial se realizo para verificar efectividad técnicas a usar y problemas que se pudieran presentar. Se aplico el protocolo en 23 pacientes que fueron llevados a cirugía de miembros inferiores, se dividieron en 2 grupos 11 recibieron bloqueos de nervio periférico y 12 analgesia epidural. Se les realizo seguimiento por 48 horas y se evaluó el control del dolor, consumo de opioides y efectos adversos. El tiempo de colocación del bloqueo fue similar en ambos grupos, el grupo de bloqueos presento menos episodios de dolor y menos episodios de dolor severo. No se presento retención urinaria en ningún paciente pero en el grupo de epidural se presento mayor incidencia de nausea y vomito (60% vs 45%). Se encontró que los bloqueos de nervio periférico son una adecuada opción para el manejo del dolor en este tipo de cirugías; y al parecer disminuye la incidencia de eventos adversos asociados a la analgesia epidural.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introducción: La herniorrafia inguinal se asocia hasta en un 50% de los casos con dolor crónico posoperatorio (DCP), y en algunos puede ser incapacitante. En este estudio se evaluaron los factores asociados al DCP en pacientes llevados a herniorrafia inguinal. Métodología: Se realizó un estudio de cohorte multicéntrico. Se obtuvo información sociodemográfica y de antecedentes personales. Se determinó la presencia e intensidad de dolor agudo posoperatorio (DAP) y se evaluaron los factores asociados al DCP con seguimiento a los dos meses del posoperatorio. Se establecieron asociaciones con la prueba chi cuadrado. Mediante una regresión lineal se evaluó el papel de los factores de confusión. Resultados: Se analizaron 108 pacientes. 54.7% presentaron DCP. La edad menor de 40 años, el DAP no controlado, el DAP severo, y el dolor no controlado entre la primera y tercera semanas del POP se relacionaron con mayor riesgo de DCP. La edad mayor a 65, el uso de opioides intratecales, la visualización y preservación de los nervios durante la cirugía, y el uso de tres o más analgésicos intravenosos con bloqueo ilioinguinal/iliohipogástrico fueron factores protectores. Discusión: El DCP es frecuente en nuestro medio. La prevención y manejo eficientes del DAP utilizando analgesia multimodal, el uso de opioide intratecal, y la identificación y preservación de los nervios en el área quirúrgica ayudan a prevenir el desarrollo de DCP. Estudios de este tipo realizados a una escala más grande, permitirán identificar otros factores relacionados con esta patología. Palabras clave: Dolor crónico postoperatorio, herniorrafia inguinal, inguinodina, factores asociados.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCCIÓN. El ultrasonido es fundamental en la medicina de emergencias, no se conoce cual debería ser la curva de aprendizaje para obtener las competencias técnicas y operativas; ACEP recomienda por cada ventana ecográfica realizar 25 repeticiones. No existe una curva de aprendizaje para ventana de VCI en la población de residentes colombianos. OBJETIVO: Determinar la curva de aprendizaje necesaria para obtener una proporción mayor al 80% de éxitos en la toma de la ventana ecográfica de la VCI, usando la escala de calificación para el aseguramiento de la calidad sugerida por ACEP, en residentes de I a III año de medicina de emergencias. METODOLOGÍA: Estudio experimental no comparativo, que evaluó la proporción de éxito en función del las tomas repetidas de la VCI por ultrasonido, mediciones que se tomaron luego de participar en una capacitación teórica y demostrativa de la técnica propuesta; se calificaron los videos según la escala publicada por ACEP. El análisis estadístico se realizó con un modelo logístico multinivel para la proporción del éxito, agrupado por repetición y agrupado por sujeto. RESULTADOS: Se obtuvo información de 8 residentes, cada uno realizo 25 repeticiones a 3 modelos sanos con asignación aleatoria. Se realizó la curva de aprendizaje obteniendo en 11 repeticiones una proporción de 0.80 (rango 0.54 a 0.92) y en 21 repeticiones una proporción de 0.9 (rango 0.75 a 0.96), datos ajustados por numero de repetición y residente. CONCLUSIÓN: La curva de aprendizaje para la ventana ecográfica de la VCI es de 11 y 21 repeticiones para obtener el 80% y 90% de éxito en residentes de medicina de emergencias de I a III año de la universidad del rosario.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El presente trabajo es un capítulo de libro titulado “Anestesia Regional y Periférica Guiada por Ultrasonido en el Paciente Crítico” que será incluido en la última edición del libro “Manual de Ultrasonido en Terapia Intensiva y Emergencias” cuyo editor es el Doctor José de Jesús Rincón Salas y que será publicado por la Editorial Prado de México para distribución latinoamericana desde dicho país. Por solicitud del editor y teniendo en cuenta el enfoque del libro, el presente trabajo está dirigido a estudiantes de formación, médicos graduados y especialistas en las áreas de cuidado intensivo, anestesiología, dolor, medicina interna y medicina de urgencias. Tiene como propósito empapar de conocimientos necesarios y prácticos en anestesia regional a personas que usualmente no han tenido contacto con la anestesia regional, pues desafortunadamente sólo en los últimos años ha sido posible que la anestesia regional haya comenzado a salir de las salas de cirugía, ámbito donde ha estado confinada tradicionalmente. El lenguaje utilizado es sencillo y el capítulo ha sido escrito para que sea fácil de leer y consultar, dejando así mensajes muy claros sobre la utilidad, viabilidad e implicaciones que tiene el uso de anestesia regional guiada por ultrasonido en cuidado intensivo. Los autores esperamos que de esta manera, el presente capítulo permita continuar superando los obstáculos que se interponen entre los invaluables beneficios de la anestesia regional y los pacientes de cuidado intensivo que necesitan de ella.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

 This article discusses the medicolegal implications of a recent judgment in relation to a patient who suffered significant morbidity as a result of patient positioning during an operative procedure. The patient developed an unexpected serious complication following surgery, in the context of a preoperative consent that did not cover every potential complication or contingency. The court held that the failure to warn of a particular risk that would have prevented the patient from undergoing a procedure but did not occur will not necessarily result in a finding of negligence in relation to another risk where the harm did occur. This finding is well aligned to current clinical practice and at the same time does not abrogate the practitioner's duty to provide a comprehensive list of possible complications during the consent process for any proceduralist. In the context of a procedure requiring anaesthesia, the importance of communication and understanding between the anaesthetist and proceduralist as to which aspects of the consent process are undertaken by whom, and to ensure the process is done comprehensively, is of great importance and is indirectly highlighted by this recent judgment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

When a muscle contracts it produces vibrations. The origin of these vibrations is not known in detail. The purpose of this study was to determine the mechanism associated with muscle vibrations. Mechanisms which have been proposed in the literature were described as theories (cross-bridge cycling, vibrating string and unfused motor unit theories). Specific predictions were derived from each theory, and tested in three conceptually different studies. In the first study, the influence of recruitment strategies of motor units (MUs) on the vibromyographic (VMG) signal was studied in the in-situ cat soleus using electrical stimulation of the soleus nerve. VMG signals increased with increasing recruitment and decreased with increasing firing rates of MUs. Similar results were obtained for the human rectus femoris (RF) muscle using percutaneous electrical stimulation of the femoral nerve. The influence of MU activation on muscle vibrations was studied in RF by analyzing VMG signals at different percentages (0-100%) of the maximal voluntary contraction (MVC). In our second study, we tested the effects of changing the material properties of the in-situ cat soleus (through muscle length changes) on the VMG signal. The magnitude of the VMG signal was higher for intermediate muscle lengths compared to the longest and the shortest muscle lengths. The decreased magnitude of the VMG signal at the longest and at the shortest muscle lengths was associated with increased passive stiffness and with decreased force transients during unfused contractions, respectively. In the third study, the effect of fatigue on muscle vibrations was studied in human RF and vastus lateralis (VL) musc1es during isometric voluntary contractions at a leveI of 70% MVC. A decrease in the VMG signal magnitude was observed in RF (presumably due to derecruitment of MUs) and an increase in VL (probably related to the enhancement of physiological tremor, which may have occurred predorninantly in a mediolateral direction) with fatigue. The unfused MU theory, which is based on the idea that force transients produced by MUs during unfused tetanic contraction is the mechanism for muscle vibrations, was supported by the results obtained in the above three studies.