899 resultados para Total Hip Prosthesis
Resumo:
Introduction Malorientation of the socket contributes to instability after hip arthroplasty but the optimal orientation of the cup in relation to the pelvis has not been unequivocally described. Large radiological studies are few and problems occur with film standardisation, measurement methodology used and alternative definitions of describing acetabular orientation. Methods A cohort of 1,578 patients from a single institution is studied where all patient data was collected prospectively. Risk factors for patients undergoing surgery are analysed. Radiological data was compared between a series of non-dislocating hips and dislocating cases matched 2:1 by operation type, age and diagnosis. Results The overall dislocation rate for all 1,578 cases was 3.23% but the rate varied according to the type of surgery performed. The rate in uncomplicated primary cases was 2.4% which increased to 9.3% for second stage implantation for a two stage procedure for infection. There was no significant difference in the variability of the dislocating and non-dislocating groups for either inclination (p = 0.393) or anteversion (p = 0.661). Conclusions A “safe zone” for socket orientation to avoid dislocation could not be defined. The cause of dislocation is multifactorial, re-establishing the anatomic centre of rotation, balancing soft tissues and avoidance of impingement around the hip are important considerations.
Resumo:
The first aim of the current study was to evaluate the survival of total hip arthroplasty (THA) in patients aged 55 years and older on a nation-wide level. The second aim was to evaluate, on a nation wide-basis, the geographical variation of the incidence of primary THA for primary OA and also to identify those variables that are possibly associated with this variation. The third aim was to evaluate the effects of hospital volume: on the length of stay, on the numbers of re-admissions and on the numbers of complications of THR on population-based level in Finland. The survival of implants was analysed based on data from the Finnish Arthroplasty Register. The incidence and hospital volume data were obtained from the Hospital Discharge Register. Cementless total hip replacements had a significantly reduced risk of revision for aseptic loosening compared with cemented hip replacements. When revision for any reason was the end point in the survival analyses, there were no significant differences found between the groups. Adjusted incidence ratios of THA varied from 1.9- to 3.0-fold during the study period. Neither the average income within a region nor the morbidity index was associated with the incidence of THA. For the four categories of volume of total hip replacements performed per hospital, the length of the surgical treatment period was shorter for the highest volume group than for the lowest volume group. The odds ratio for dislocations was significantly lower in the high volume group than in the low volume group. In patients who were 55 years of age or older, the survival of cementless total hip replacements was as good as that of the cemented replacements. However, multiple wear-related revisions of the cementless cups indicate that excessive polyethylene wear was a major clinical problem with modular cementless cups. The variation in the long-term rates of survival for different cemented stems was considerable. Cementless proximal porous-coated stems were found to be a good option for elderly patients. When hip surgery was performed on with a large repertoire, the indications to perform THAs due to primary OA were tight. Socio-economic status of the patient had no apparent effect on THA rate. Specialization of hip replacements in high volume hospitals should reduce costs by significantly shortening the length of stay, and may reduce the dislocation rate.
Resumo:
There is an ongoing controversy as to which methods in total hip arthroplasty (THA) could provide young patients with best long-term results. THA is an especially demanding operation in patients with severely dysplastic hips. The optimal surgical treatment for these patients also remains controversial. The aim of this study was to evaluate the long-term survival of THA in young patients (<55 years at the time of the primary operation) on a nation-wide level, and to analyze the long-term clinical and radio-graphical outcome of uncemented THA in patients with severely dysplastic joints. Survival of 4661 primary THAs performed for primary osteoarthritis (OA), 2557 primary THAs per-formed for rheumatoid arthritis (RA), and modern uncemented THA designs performed for primary OA in young patients, were analysed from the Finnish Arthroplasty Register. A total of 68 THAs were per-formed in 56 consecutive patients with high congenital hip dislocation between 1989-1994, and 68 THAs were performed in 59 consecutive patients with severely dysplastic hips and a previous Schanz osteotomy of the femur between 1988-1995 at the Orton Orthopaedic Hospital, Helsinki, Finland. These patients underwent a detailed physical and radiographical evaluation at a mean of 12.3 years and 13.0 years postoperatively, respectively. The risk of stem revision due to aseptic loosening in young patients with primary OA was higher for cemented stems than for proximally porous-coated or HA-coated uncemented stems implanted over the 1991-2001 period. There was no difference in the risk of revision between all-poly cemented-cups and press-fit porous-coated uncemented cups implanted during the same period, when the end point was defined as any revision (including exchange of liner). All uncemented stem designs studied in young patients with primary OA had >90% survival rates at 10 years. The Biomet Bi-Metric stem had a 95% (95% CI 93-97) survival rate even at 15 years. When the end point was defined as any revision, 10 year survival rates of all uncemented cup designs except the Harris-Galante II decreased to <80%. In young patients with RA, the risk of stem revision due to aseptic loosening was higher with cemented stems than with proximally porous-coated uncemented stems. In contrast, the risk of cup revision was higher for all uncemented cup concepts than for all-poly cemented cups with any type of cup revision as the end point. The Harris hip score increased significantly (p<0.001) both in patients with high con-genital hip dislocation and in patients with severely dysplastic hips and a previous Schanz osteotomy, treated with uncemented THA. There was a negative Trendelenburg sign in 92% and in 88% of hips, respectively. There were 12 (18%) and 15 (22%) perioperative complications. The rate of survival for the CDH femoral components, with revision due to aseptic loosening as the end point, was 98% (95% CI 97-100) at 10 years in patients with high hip dislocation and 92% (95% CI, 86-99) at 14 years in patients with a previous Schanz osteotomy. The rate of survival for press-fit, porous-coated acetabular components, with revision due to aseptic loosening as the end point, was 95% (95% CI 89-100) at 10 years in patients with high hip dislocation, and 98% (95% CI 89-100) in patients with a previous Schanz osteotomy. When revision of the cup for any reason was defined as the end point, 10 year sur-vival rates declined to 88% (95% CI 81-95) and to 69% (95% CI, 56-82), respectively. For young patients with primary OA, uncemented proximally circumferentially porous- and HA-coated stems are the implants of choice. However, survival rates of modern uncemented cups are no better than that of all-poly cemented cups. Uncemented proximally circumferentially porous-coated stems and cemented all-poly cups are currently the implants of choice for young patients with RA. Uncemented THA, with placement of the cup at the level of the true acetabulum, distal advancement of the greater trochanter and femoral shortening osteotomy provided patients with high congenital hip dislocation good long-term outcomes. Most of the patients with severely dysplastic hips and a previous Schanz osteotomy can be successfully treated with the same method. However, the subtrochanteric segmental shortening with angular correction gives better leg length correction for the patients with a previous low-seated unilateral Schanz osteotomy.
Resumo:
Some perioperative clinical factors related to the primary cemented arthroplasty operation for osteoarthritis of the hip or knee joint are studied and discussed in this thesis. In a randomized, double-blind study, 39 patients were divided into two groups: one receiving tranexamic acid and the other not receiving it. Tranexamic acid was given in a dose of 10 mg/kg before the operation and twice thereafter, at 8-hour intervals. Total blood loss was smaller in the tranexamic acid group than in the control group. No thromboembolic complications were noticed. In a prospective, randomized study, 58 patients with hip arthroplasty and 39 patients with knee arthroplasty were divided into groups with postoperative closed-suction drainage and without drainage. There was no difference in healing of the wounds, postoperative blood transfusions, complications or range of motion. As a result of this study, the use of drains is no longer recommended. In a randomised study the effectiveness of a femoral nerve block (25 patients) was compared with other methods of pain control (24 patients) on the first postoperative day after total knee arthroplasty. The femoral block consisted of a single injection administered at patients´ bedside during the surgeon´s hospital rounds. Femoral block patients reported less pain and required half of the amount of oxycodone. Additional femoral block or continued epidural analgesia was required more frequently by the control group patients. Pain management with femoral blocks resulted in less work for nursing staff. In a retrospective study of 422 total hip and knee arthroplasty cases the C-reactive protein levels and clinical course were examined. After hip and knee arthroplasty the maximal C-reactive protein values are seen on the second and third postoperative days, after which the level decreases rapidly. There is no difference between patients with cemented or uncemented prostheses. Major postoperative complications may cause a further increase in C-reactive protein levels at one and two weeks. In-hospital and outpatient postoperative control radiographs of 200 hip and knee arthroplasties were reviewed retrospectively. If postoperative radiographs are of good quality, there seems to be no need for early repetitive radiographs. The quality and safety of follow-up is not compromised by limiting follow-up radiographs to those with clinical indications. Exposure of the patients and the staff to radiation is reduced. Reading of the radiographs by only the treating orthopaedic surgeon is enough. These factors may seem separate from each other, but linking them together may help the treating orthopaedic surgeon to adequate patient care strategy. Notable savings can be achieved.
Resumo:
Aims: We report on the outcome of the Exeter Contemporary flanged cemented all-polyethylene acetabular component with a mean follow-up of 12 years (10 to 13.9). This study reviewed 203 hips in 194 patients. 129 hips in 122 patients are still in situ; 66 hips in 64 patients were in patients who died before ten years, and eight hips (eight patients) were revised. Clinical outcome scores were available for 108 hips (104 patients) and radiographs for 103 hips (100 patients). Patients and Methods: A retrospective review was undertaken of a consecutive series of 203 routine primary cemented total hip arthroplasties (THA) in 194 patients. Results: There were no acetabular component revisions for aseptic loosening. Acetabular revision was undertaken in eight hips. In four hips revision was necessitated by periprosthetic femoral fractures, in two hips by recurrent dislocation, in one hip for infection and in one hip for unexplained ongoing pain. Oxford and Harris hip scores demonstrated significant clinical improvement (all p < 0.001). Radiolucent lines were present in 37 (36%) of the 103 acetabular components available for radiological evaluation. In 27 of these, the line was confined to zone 1. No component had migrated. Conclusion: Kaplan–Meier survivorship, with revision for aseptic loosening as the endpoint, was 100% at 12.5 years and for all causes was 97.8% (95% confidence interval 95.6 to 100) when 40 components remained at risk. The Exeter Contemporary flanged cemented acetabular component demonstrates excellent survivorship at 12.5 years. Take home message: The Exeter Contemporary flanged cemented acetabular component has excellent clinical outcomes and survivorship when used with the Exeter stem in total hip arthroplasty.
Resumo:
Background The incidence of obesity amongst patients presenting for elective Total Hip Arthroplasty (THA) has increased in the last decade and the relationship between obesity and the need for joint replacement has been demonstrated. This study evaluates the effects of morbid obesity on outcomes following primary THA by comparing short-term outcomes in THA between a morbidly obese (BMI ≥40) and a normal weight (BMI 18.5 - <25) cohort at our institution between January 2003 and December 2010. Methods Thirty-nine patients included in the morbidly obese group were compared with 186 in the normal weight group. Operative time, length of stay, complications, readmission and length of readmission were compared. Results Operative time was increased in the morbidly obese group at 122 minutes compared with 100 minutes (p=0.002). Post-operatively there was an increased 30-day readmission rate related to surgery of 12.8% associated with BMI ≥40 compared with 2.7% (p= 0.005) as well as a 5.1 fold increase in surgery related readmitted bed days - 0.32 bed days per patient for normal weight compared with 1.64 per patient for the morbidly obese (p=0.026). Conclusion Morbidly obese patients present a technical challenge and likely this and the resultant complications are underestimated. More work needs to be performed in order to enable suitable allocation of resources.
Resumo:
The purpose of this study was to identify preoperative predictors of length of stay after primary total hip arthroplasty in a patient population reflecting current trends toward shorter hospitalization and using readily obtainable factors that do not require scoring systems. A retrospective review of 112 consecutive patients was performed. High preoperative pain level and patient expectation of discharge to extended care facilities (ECFs) were the only significant multivariable predictors of hospitalization extending beyond 2 days (P=0.001 and P<0.001 respectively). Patient expectation remained significant after adjusting for Medicare's 3-day requirement for discharge to ECFs (P<0.001). The study was adequately powered to analyze the variables in the multivariable logistic regression model, which had a concordance index of 0.857.
Resumo:
BACKGROUND: Development of hip adductor, tensor fascia lata, and rectus femoris muscle contractures following total hip arthroplasties are quite common, with some patients failing to improve despite treatment with a variety of non-operative modalities. The purpose of the present study was to describe the use of and patient outcomes of botulinum toxin injections as an adjunctive treatment for muscle tightness following total hip arthroplasty. METHODS: Ten patients (14 hips) who had hip adductor, abductor, and/or flexor muscle contractures following total arthroplasty and had been refractory to physical therapeutic efforts were treated with injection of botulinum toxin A. Eight limbs received injections into the adductor muscle, 8 limbs received injections into the tensor fascia lata muscle, and 2 limbs received injection into the rectus femoris muscle, followed by intensive physical therapy for 6 weeks. RESULTS: At a mean final follow-up of 20 months, all 14 hips had increased range in the affected arc of motion, with a mean improvement of 23 degrees (range, 10 to 45 degrees). Additionally all hips had an improvement in hip scores, with a significant increase in mean score from 74 points (range, 57 to 91 points) prior to injection to a mean of 96 points (range, 93 to 98) at final follow-up. There were no serious treatment-related adverse events. CONCLUSION: Botulinum toxin A injections combined with intensive physical therapy may be considered as a potential treatment modality, especially in difficult cases of muscle tightness that are refractory to standard therapy.
Resumo:
BACKGROUND: The purpose of this study was to evaluate whether compliance and rehabilitative efforts were predictors of early clinical outcome of total hip resurfacing arthroplasty. METHODS: A cross-sectional survey was utilized to collect information from 147 resurfacing patients, who were operated on by a single surgeon, regarding their level of commitment to rehabilitation following surgery. Patients were followed for a mean of 52 months (range, 24 to 90 months). Clinical outcomes and functional capabilities were assessed utilizing the Harris hip objective rating system, the SF-12 Health Survey, and an eleven-point satisfaction score. A linear regression analysis was used to determine whether there was any correlation between the rehabilitation commitment scores and any of the outcome measures, and a multivariate regression model was used to control for potentially confounding factors. RESULTS: Overall, an increased level of commitment to rehabilitation was positively correlated with each of the following outcome measures: SF-12 Mental Component Score, SF-12 Physical Component Score, Harris Hip score, and satisfaction scores. These correlations remained statistically significant in the multivariate regression model. CONCLUSIONS: Patients who were more committed to their therapy after hip resurfacing returned to higher levels of functionality and were more satisfied following their surgery.