161 resultados para TAPER
Resumo:
Purpose: To test the strength to failure and fracture mode of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments vs cemented standard porcelain-fused-to-metal (PFM) crowns. Materials and Methods: Sixty-four locking taper abutments were randomly allocated to four groups and were cleaned in ethanol in an ultrasonic bath for 5 min. After drying under ambient conditions, the abutments were grit blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n = 16 per group) of Tescera (Bisco), Ceramage (Shofu), and Diamond Crown (DRM) according to the manufacturer`s instructions. The porcelain-fused-to-metal crowns were fabricated by conventional means involving the construction and a wax pattern and casting of a metallic coping followed by sintering of increasing layers of porcelain. All crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1 mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% level of significance was utilized for statistical analysis. Results: The single load to failure (+/- SD) results were: Tescera (1130 +/- 239 N), Ceramage (1099 +/- 257 N), Diamond Crown (1155 +/- 284 N), and PFM (1081 +/- 243 N). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment/metallic coping exposure. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. Conclusion: The three indirect composites and PFM systems fractured at loads higher than those typically associated with normal occlusal function. Although each material had a different composition and handling technique, no significant differences were found concerning their single load to fracture resistance among composite systems and PFM.
Resumo:
Introduction: The aim of this study was to evaluate the root canal preparation in flat-oval canals treated with either rotary or self-adjusting file (SAF) by using micro-tomography analysis. Methods: Forty mandibular incisors were scanned before and after root canal instrumentation with rotary instruments (n = 20) or SAF (n = 20). Changes in canal volume, surface area, and cross-sectional geometry were compared with preoperative values. Data were compared by independent sample t test and chi(2) test between groups and paired sample t test within the group (alpha = 0.05). Results: Overall, area, perimeter, roundness, and major and minor diameters revealed no statistical difference between groups (P > .05). In the coronal third, percentage of prepared root canal walls and mean increases of volume and area were significantly higher with SAF (92.0%, 1.44 +/- 0.49 mm(3), 0.40 +/- 0.14 mm(2), respectively) than rotary instrumentation (62.0%, 0.81 +/- 0.45 mm(3), 0.23 +/- 0.15 mm2, respectively) (P < .05). SAF removed dentin layer from all around the canal, whereas rotary instrumentation showed substantial untouched areas. Conclusions: In the coronal third, mean increases of area and volume of the canal as well as the percentage of prepared walls were significantly higher with SAF than with rotary instrumentation. By using SAF instruments, flat-oval canals were homogenously and circumferentially prepared. The size of the SAF preparation in the apical third of the canal was equivalent to those prepared with #40 rotary file with a 0.02 taper. (J Endod 2011;37:1002-1007)
Resumo:
P>Objective To evaluate the influence of apical size on cleaning of the apical third of curved canals prepared with rotary instruments. Methodology Forty-four mesiobuccal canals of maxillary molars teeth were instrumented to different apical sizes (30, 0.02; 35, 0.02; 40, 0.02; 45, 0.02) using a crown-down technique. After canal preparation, the apical thirds of the roots were submitted to histological processing and examination. The specimens were analysed at 40x magnification and the images were submitted to morphometric analysis with an integration grid to evaluate the percentage of debris and uninstrumented root canal walls. The action of the instruments on the root canal walls was assessed based on the surface regularity, abrupt change on the continuity of root canal walls, and partial or total pre-dentine removal. The results were statistically compared using one-way anova with post hoc Tukey test. Pearson`s correlation was performed to identify potential correlations between values. Results The percentage of uninstrumented root canal dentine was higher when apical enlargement was performed with instruments 30, 0.02 taper (55.64 +/- 4.62%) and 35, 0.02 taper (49.03 +/- 5.70%) than with instruments 40, 0.02 taper (38.08 +/- 10.44%) and 45, 0.02 taper (32.65 +/- 8.51%) (P < 0.05). More debris were observed when apical enlargement was performed with instruments 30, 0.02 taper (34.62 +/- 9.49%) and 35, 0.02 taper (25.33 +/- 7.37%) (P < 0.05). There was a significant correlation between the amount of remaining debris and the perimeter of uninstrumented root canal dentine (r = 0.9130, P < 0.001). Conclusion No apical enlargement size allowed the root canal walls to be prepared completely. Apical third cleanliness could be predicted by instrument diameter.
Resumo:
Evaluate, through computerized tomography, canal transportation and centring ability of RaCe rotary instruments after preparation of mesiobuccal root canals in maxillary molar teeth. Twenty-seven teeth were submitted to three cone beam tomographic analyses, one preoperatively, and two after preparation with file size 35, .02 taper and size 50, .02 taper. Canal transportation and centring ability were measured with reference to the distance between the noninstrumented portion of the root canals and the mesial and distal periphery of the root, compared with images obtained after the preparation with size 35 and 50 instruments. Canal transportation after preparation with the size 35 file was 0.030 +/- 0.253 mm and after the size 50 file was 0.057 +/- 0.317 mm. The centring ratio values after preparation with the size 35 file was 0.42 +/- 0.32 and after the size 50 file was 0.54 +/- 0.29, with no significant statistical difference between the groups. RaCe instruments allowed the preparation of curved root canals with preparation diameters larger than those normally used with minimal canal transportation and adequate centring ability.
Resumo:
Purpose: Gaps between an abutment and a dental implant are unavoidable, and microleakage may occur, leading to problems such as malodor and peri-implantitis. The aim of the present in vitro study was to investigate leakage of Staphylococcus aureus through the implant/abutment interface by the method of bacterial culture, and to compare the leakage rates of two different types of implant-abutment connections. Materials and Methods: Twenty Morse taper implants with abutments were divided into two groups: group A, which were evaluated for microleakage into the inner part of the implants, and group B, which were evaluated for microleakage from the inner part of the implants. Twenty internal-hexagon implants with abutments were also divided into two groups: group C, which were evaluated for microleakage into the inner part of the implants, and group D, which were evaluated for microleakage from the inner part of the implants. For the evaluation of leakage from the implants, the assemblies had the inner parts inoculated with S aureus, and each assembly was incubated in sterile brain heart infusion broth for 1 week. For assessment of leakage into the implants, each assembly was submerged in 4 mL S aureus culture in tubes and incubated for 2 weeks. The microleakage of the two implant connections was compared. Results: Microbial leakage occurred in all groups, and there was no statistically significant difference between groups A and C or between groups B and D. Conclusions: In vitro, S aureus leakage through the implant/abutment interface occurred with both Morse taper and internal-hexagon implants. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:56-62
Resumo:
An experimental and Finite Element study was performed on the bending behaviour of wood beams of the Pinus Pinaster species repaired with adhesively-bonded carbon–epoxy patches, after sustaining damage by cross-grain failure. This damage is characterized by crack growth at a small angle to the beams longitudinal axis, due to misalignment between the wood fibres and the beam axis. Cross-grain failure can occur in large-scale in a wood member when trees that have grown spirally or with a pronounced taper are cut for lumber. Three patch lengths were tested. The simulations include the possibility of cohesive fracture of the adhesive layer, failure within the wood beam in two propagation planes and patch interlaminar failure, by the use of cohesive zone modelling. The respective cohesive properties were estimated either by an inverse method or from the literature. The comparison with the tests allowed the validation of the proposed methodology, opening a good perspective for the reduction of costs in the design stages of these repairs due to extensive experimentation.
Resumo:
A precisão do volume de um povoamento florestal torna-se importante à medida que as empresas florestais integram verticalmente suas atividades e o resíduo da elaboração de um produto torna-se matéria-prima para outros. Os estudos realizados objetivaram avaliar a acurácia dos modelos polinomiais propostos por Schöepfer (1966), Hradetzky (1976) e Goulding & Murray (1976), na estimativa dos diâmetros e volumes ao longo do fuste de Tectona grandis L.f. de quatro povoamentos localizados na microrregião do Baixo Rio Acre e, ainda, testar a identidade do melhor modelo polinomial, avaliando-se a adequação de manter as áreas agrupadas ou segregá-las em grupos menores ou individualmente. A base de dados foi constituída de 159 árvores cubadas rigorosamente. Na avaliação da acurácia dos modelos foram empregadas estatísticas de desvio médio, desvio padrão das diferenças, soma dos quadrados dos resíduos relativos e resíduos percentuais. O modelo Goulding & Murray (1976) gerou as melhores estimativas de diâmetros e volumes ao longo do fuste, seguido pelos modelos Hradetzky (1976) e Schöepfer (1966). O teste de identidade de modelo mostrou ser mais adequado realizar ajustes independentes para as áreas 1 e 4 e para o subgrupo 2 e 3.
Resumo:
O treino competitivo envolve exercício intenso e prolongado, capaz de modular o número e actividade das células imunitárias. Quando demasiado exigente poderá induzir fadiga e aumentar a susceptibilidade a doenças. Esta dissertação apresenta três estudos desenvolvidos no âmbito da Imunologia do Exercício, considerando a análise da resposta celular imunitária sistémica aguda e crónica ao exercício aplicada em situações reais do treino competitivo de natação, controlando factores passíveis de influenciar esta resposta. Pretendeu-se avaliar a resposta imunitária a uma sessão de treino prolongada e intensa, durante as 24h de recuperação (Estudo 1) e a uma época de treino com sete meses (Estudo 2), e estudar a influência de um macrociclo de treino de quatro meses sobre a resposta imunitária à mesma sessão de treino e período de recuperação (Estudo 3), controlando sexo, fases do ciclo menstrual, maturidade, escalão, especialidade, performance, cargas de treino e sintomas respiratórios superiores (URS). A sessão de treino induziu a diminuição da vigilância imunitária adquirida imediatamente e, pelo menos nas 2h seguintes. Juvenis e seniores recuperaram totalmente 24h depois, mas não os juniores, reforçando a ideia da existência de uma janela aberta para a infecção após exercícios prolongados e intensos e sugerindo uma recuperação menos eficiente para os juniores. No período de treino mais intenso da época observou-se uma imunodepressão e maior prevalência de URS. No final da época, a imunidade inata diminuiu aparentando maior sensibilidade aos efeitos cumulativos da carga de treino, enquanto a imunidade adquirida parece ter recuperado após o taper. O macrociclo de treino atenuou a resposta imunitária à sessão de treino e aumentou o período de janela aberta às infecções (efeitos mais acentuados nos adolescentes). Os resultados evidenciam a importância de controlar alterações imunitárias durante a época competitiva, especialmente em períodos de treino intenso e quando se realizam sessões de treino intensas consecutivas com recuperações inferiores a 24h.
Resumo:
Abdominal Aortic Aneurysms (AAA) haemorhaging is a life-threatening disease. An aneurysm is a permanent swelling of an artery due to a weakness in its wall. Current surgical repair involves opening the chest or abdomen, gaining temporary vascular control of the aorta and suturing a prosthetic graft to the healthy aorta within the aneurysm itself The outcome of this surgical approach is not perfect, and the quality of life after this repair is impaired by postoperative pain, sexual dysfunction, and a lengthy hospital stay resulting in high health costs. All these negative effects are related to the large incision and extensive tissue dissection. Endovascular grafting is an alternative to the standard surgical method. This treatment is a less invasive method of treating aortic aneurysms. It involves a surgical exposure of the common femoral arteries where the stent graft can be inserted through by an over-the-wire technique. All manipulations are controlled from a remote place by the use of a catheter and this technique avoids the need to directly expose the diseased artery through a large incision or an extensive dissection. The proposed design method outlined in this project is to develop the endovascular approach. The main aim is to design an unitary bifurcated stent graft (1 e- bifurcated graft as a single component) to treat these Abdominal Aortic Aneurysms. This includes the delivery system and deployment mechanism necessary to first accurately position the stent graft across the aneurysm sac and also across the iliac bifurcation, and secondly fix the stent graft in position by using expandable metal stents. Thus, excluding the aneurysm from the circulation and therefore preventing rupture. Miniaturisation is a critical aspect of this design, as the smaller the crimped stent graft the easier to guide through the vascular system to the desired location. Biocompatibility is an important aspect. The preferred materials for this prosthesis are to use Shape Memory Alloys for the stent and a multifilament fabric for the graft. A taper design is applied for the geometry as this gives a favourable flow characteristic and reduced wave reflections. Adequate testing of the stent graft to prove its durability and the ease of the method of deployment is a prerequisite. A bench test facility has being designed and build to replicate the cardiovascular system and the disease in question aortic aneurysms at the iliac bifurcation. The testing here shows the feasibility of the proposed delivery system and the durability of the stent graft across the aneurysm sac. Finally, these endovascular treatments offer the economic advantage of short hospital stays or even treatment as an outpatient, as well as elimination of the need for postoperative intensive care The risk of developing an aneurysm increases with age, that is one of the mam reasons to look for less invasive ways of treating aneurysms. Consequently, there is enormous pressure to develop and use these devices rapidly.
Resumo:
L'hétérotopie sous-corticale en bandes ou double-cortex est une malformation cérébrale causée par une interruption de la migration des neurones du néocortex pendant sa formation. La souris HeCo est un modèle murin de cette affection, caractérisée par un amas de neurones corticaux dans la substance blanche sous-corticale. Les signes cliniques de cette maladie sont le plus souvent une épilepsie réfractaire, un retard développemental et mental. Chez l'homme, l'hétérotopie se trouve en partie en profondeur du cortex somatotopique moteur et sensitif et semble participer à leurs fonctions. L'IRM fonctionnelle a montré lors d'une tâche motrice (taper des doigts), l'activation en plus du cortex moteur controlatéral du cortex hétérotopique sous-jacent. La pathogenèse des malformations corticales est toujours mal comprise, c'est pourquoi il est important d'avoir plusieurs modèles animaux. Jusqu'il a peu, il n'existait que le rat TISH, découvert en 1997, dont la génétique n'est pas connue à ce jour. La souris HeCo est un nouveau modèle animal de malformation corticale dont le gène muté impliquant une protéine associée aux microtubules a été découvert récemment. Elle partage avec les cas humains un seuil épileptique abaissé et un certain retard développemental. Objectif : Déterminer si le cortex hétérotopique de la souris HeCo est activé lors d'une tâche sensitive (exploration de l'environnement à l'aide des vibrisses du museau). Méthode : Chez la souris, les vibrisses sont des organes sensitifs essentiels dans l'exploration de l'environnement. Pour déterminer si le cortex hétérotopique est actif lors d'une tâche sensitive, on utilisera donc un exercice de découverte d'une cage enrichie en stimulus. Afin de visualiser les régions du cerveau actives, on utilisera plusieurs méthodes: l'autoradiographie ([14C]2- deoxyglucose, 2-DG) et l'immunohistochimie c-Fos. Le 2-DG est un analogue du glucose qui se fixe dans les régions cérébrales métaboliquement actives, ici impliquées dans la sensibilité. Il est injecté dans le péritoine de la souris à jeun avant l'exploration. Le contrôle négatif se fera en coupant les vibrisses d'un côté avant la tâche sensitive. A la fin de la tâche, on prélève des coupes du cerveau pour mesurer l'autoradioactivité. L'immunohistochimie c-Fos est réalisée sur les cerveaux de souris ayant effectué la même tâche sensitive et détecte une protéine d'activation neuronale. Afin de détecter une activation de l'hétérotopie à plus long terme, on utilisera la cytochrome oxydase, une enzyme qui met en évidence les régions contenant beaucoup de mitochondries, donc métaboliquement très actives. Résultats : La cytochrome oxydase a marqué de façon égale le cortex homotopique de la souris HeCo et le cortex des souris contrôle. Par ailleurs, chez le mutant, elle a montré un faible marquage dans la partie médiale de l'hétérotopie et des zones de marquage plus intenses dans sa partie latérale. L'autoradiographie 2-DG a montré un pattern classique d'activation du cortex homotopique du côté stimulé, avec une intensité plus marquée dans la couche IV. Du même côté, l'hétérotopie latérale montre une intensité similaire à celui de la couche IV. Du côté non stimulé, on note une intensité faible, tant dans le cortex homotopique que dans le cortex hétérotopique. L'immunohistochimie c-Fos a montré une nette différence entre l'hémisphère stimulé et l'hémisphère non stimulé dans la couche IV comme dans l'hétérotopie. Il existe, tant du côté stimulé que du côté non stimulé, un gradient dans l'hétérotopie, le marquage latéral étant du même ordre que dans la couche IV alors qu'il est moins intense médialement. Conclusion : l'hétérotopie corticale latérale, située en particulier sous le cortex somatosensoriel, semble traiter l'information périphérique controlatérale dans le même ordre que le cortex homotopique.
Resumo:
Improving safety at nighttime work zones is important because of the extra visibility concerns. The deployment of sequential lights is an innovative method for improving driver recognition of lane closures and work zone tapers. Sequential lights are wireless warning lights that flash in a sequence to clearly delineate the taper at work zones. The effectiveness of sequential lights was investigated using controlled field studies. Traffic parameters were collected at the same field site with and without the deployment of sequential lights. Three surrogate performance measures were used to determine the impact of sequential lights on safety. These measures were the speeds of approaching vehicles, the number of late taper merges and the locations where vehicles merged into open lane from the closed lane. In addition, an economic analysis was conducted to monetize the benefits and costs of deploying sequential lights at nighttime work zones. The results of this study indicates that sequential warning lights had a net positive effect in reducing the speeds of approaching vehicles, enhancing driver compliance, and preventing passenger cars, trucks and vehicles at rural work zones from late taper merges. Statistically significant decreases of 2.21 mph mean speed and 1 mph 85% speed resulted with sequential lights. The shift in the cumulative speed distributions to the left (i.e. speed decrease) was also found to be statistically significant using the Mann-Whitney and Kolmogorov-Smirnov tests. But a statistically significant increase of 0.91 mph in the speed standard deviation also resulted with sequential lights. With sequential lights, the percentage of vehicles that merged earlier increased from 53.49% to 65.36%. A benefit-cost ratio of around 5 or 10 resulted from this analysis of Missouri nighttime work zones and historical crash data. The two different benefitcost ratios reflect two different ways of computing labor costs.
Resumo:
In work-zone configurations where lane drops are present, merging of traffic at the taper presents an operational concern. In addition, as flow through the work zone is reduced, the relative traffic safety of the work zone is also reduced. Improving work-zone flow-through merge points depends on the behavior of individual drivers. By better understanding driver behavior, traffic control plans, work zone policies, and countermeasures can be better targeted to reinforce desirable lane closure merging behavior, leading to both improved safety and work-zone capacity. The researchers collected data for two work-zone scenarios that included lane drops with one scenario on the Interstate and the other on an urban arterial roadway. The researchers then modeled and calibrated these scenarios in VISSIM using real-world speeds, travel times, queue lengths, and merging behaviors (percentage of vehicles merging upstream and near the merge point). Once built and calibrated, the researchers modeled strategies for various countermeasures in the two work zones. The models were then used to test and evaluate how various merging strategies affect safety and operations at the merge areas in these two work zones.
Resumo:
This report updates the Iowa Department of Transportation (DOT) design procedures for circular, slope-tapered concrete culverts. The current practice is to use the design coefficients for a square-edged, circular concrete culvert with a headwall that are found in Hydraulic Series No. 5 (HDS-5). New inlet control design constants and entrance loss coefficients were calculated for the slope-tapered culverts and then compared with the HDS-5 coefficients (square edge). In addition, various reducer lengths and taper ratios were also studied to determine what impact, if any, they have on the design coefficients. All of the laboratory testing was done at the Federal Highway Administration�s Turner-Fairbank Highway Research Center located in McLean, Virginia.
Resumo:
Abstract
Resumo:
El presente trabajo tiene por objetivo principal analizar tres funciones de perfil del fuste sobre tres clones de Populus x euramericana (Canadá Blanco, I-214 y MC) en la Comunidad Foral de Navarra para elaborar una tarifa de cubicación con clasificación de volumen. Para minimizar el efecto de la autocorrelación entre los residuos se emplea una estructura de error continua autorregresiva de orden 2 o de orden 3 en función del clon analizado. Por otra parte, se compara el coeficiente local de forma de cada uno de los clones estudiados mediante dos metodologías: el análisis de la varianza de la estimación individual de dicho coeficiente y el contraste del estadístico de máxima verosimilitud entre ajustes, resultando ser el clon Canadá el más cónico de los tres. Los datos utilizados provienen de 143 chopos de plantaciones coetáneas y con mismo marco de plantación (marco real de 4,5 × 4,5 m).