974 resultados para Intracranial aneurysm quanti cation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECT: In this study the accuracy of multislice computerized tomography (MSCT) angiography in the postoperative examination of clip-occluded intracranial aneurysms was compared with that of intraarterial digital subtraction (DS) angiography METHODS: Forty-nine consecutive patients with 60 clipped aneurysms (41 of which had ruptured) were studied with the aid of postoperative MSCT and DS angiography. Both types of radiological studies were reviewed independently by two observers to assess the quality of the images, the artifacts left by the clips, the completeness of aneurysm occlusion, the patency of the parent vessel, and the duration and cost of the examination. The quality of MSCT angiography was good in 42 patients (86%). Poor-quality MSCT angiograms (14%) were a result of the late acquisition of images in three patients and the presence of clip or motion artifacts in four. Occlusion of the aneurysm on good-quality MSCT angiograms was confirmed in all but two patients in whom a small (2-mm) remnant was confirmed on DS angiograms. In one patient, occlusion of a parent vessel was seen on DS angiograms but missed on MSCT angiograms. The sensitivity and specificity for detecting neck remnants on MSCT angiography were both 100%, and the sensitivity and specificity for evaluating vessel patency were 80 and 100%, respectively (95% confidence interval 29.2-100%). Interobserver agreements were 0.765 and 0.86, respectively. The mean duration of the examination was 13 minutes for MSCT angiography and 75 minutes for DS angiography (p < 0.05). Multislice CT angiography was highly cost effective (p < 0.01). CONCLUSIONS: Current-generation MSCT angiography is an accurate noninvasive tool used for assessment of clipped aneurysms in the anterior circulation. Its high sensitivity and low cost warrant its use for postoperative routine control examinations following clip placement on an aneurysm. Digital subtraction angiography must be performed if the interpretation of MSCT angiograms is doubtful or if the aneurysm is located in the posterior circulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The purpose of this study was to assess the incidence of neurological complications in patients with infective endocarditis, the risk factors for their development, their influence on the clinical outcome, and the impact of cardiac surgery. METHODS AND RESULTS This was a retrospective analysis of prospectively collected data on a multicenter cohort of 1345 consecutive episodes of left-sided infective endocarditis from 8 centers in Spain. Cox regression models were developed to analyze variables predictive of neurological complications and associated mortality. Three hundred forty patients (25%) experienced such complications: 192 patients (14%) had ischemic events, 86 (6%) had encephalopathy/meningitis, 60 (4%) had hemorrhages, and 2 (1%) had brain abscesses. Independent risk factors associated with all neurological complications were vegetation size ≥3 cm (hazard ratio [HR] 1.91), Staphylococcus aureus as a cause (HR 2.47), mitral valve involvement (HR 1.29), and anticoagulant therapy (HR 1.31). This last variable was particularly related to a greater incidence of hemorrhagic events (HR 2.71). Overall mortality was 30%, and neurological complications had a negative impact on outcome (45% of deaths versus 24% in patients without these complications; P<0.01), although only moderate to severe ischemic stroke (HR 1.63) and brain hemorrhage (HR 1.73) were significantly associated with a poorer prognosis. Antimicrobial treatment reduced (by 33% to 75%) the risk of neurological complications. In patients with hemorrhage, mortality was higher when surgery was performed within 4 weeks of the hemorrhagic event (75% versus 40% in later surgery). CONCLUSIONS Moderate to severe ischemic stroke and brain hemorrhage were found to have a significant negative impact on the outcome of infective endocarditis. Early appropriate antimicrobial treatment is critical, and transitory discontinuation of anticoagulant therapy should be considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Single Nucleotide Polymorphisms, among other type of sequence variants, constitute key elements in genetic epidemiology and pharmacogenomics. While sequence data about genetic variation is found at databases such as dbSNP, clues about the functional and phenotypic consequences of the variations are generally found in biomedical literature. The identification of the relevant documents and the extraction of the information from them are hampered by the large size of literature databases and the lack of widely accepted standard notation for biomedical entities. Thus, automatic systems for the identification of citations of allelic variants of genes in biomedical texts are required. Results: Our group has previously reported the development of OSIRIS, a system aimed at the retrieval of literature about allelic variants of genes http://ibi.imim.es/osirisform.html. Here we describe the development of a new version of OSIRIS (OSIRISv1.2, http://ibi.imim.es/OSIRISv1.2.html webcite) which incorporates a new entity recognition module and is built on top of a local mirror of the MEDLINE collection and HgenetInfoDB: a database that collects data on human gene sequence variations. The new entity recognition module is based on a pattern-based search algorithm for the identification of variation terms in the texts and their mapping to dbSNP identifiers. The performance of OSIRISv1.2 was evaluated on a manually annotated corpus, resulting in 99% precision, 82% recall, and an F-score of 0.89. As an example, the application of the system for collecting literature citations for the allelic variants of genes related to the diseases intracranial aneurysm and breast cancer is presented. Conclusion: OSIRISv1.2 can be used to link literature references to dbSNP database entries with high accuracy, and therefore is suitable for collecting current knowledge on gene sequence variations and supporting the functional annotation of variation databases. The application of OSIRISv1.2 in combination with controlled vocabularies like MeSH provides a way to identify associations of biomedical interest, such as those that relate SNPs with diseases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new registration algorithm, called Temporal Di eomorphic Free Form Deformation (TDFFD), and its application to motion and strain quanti cation from a sequence of 3D ultrasound (US) images. The originality of our approach resides in enforcing time consistency by representing the 4D velocity eld as the sum of continuous spatiotemporal B-Spline kernels. The spatiotemporal displacement eld is then recovered through forward Eulerian integration of the non-stationary velocity eld. The strain tensor iscomputed locally using the spatial derivatives of the reconstructed displacement eld. The energy functional considered in this paper weighs two terms: the image similarity and a regularization term. The image similarity metric is the sum of squared di erences between the intensities of each frame and a reference one. Any frame in the sequence can be chosen as reference. The regularization term is based on theincompressibility of myocardial tissue. TDFFD was compared to pairwise 3D FFD and 3D+t FFD, bothon displacement and velocity elds, on a set of synthetic 3D US images with di erent noise levels. TDFFDshowed increased robustness to noise compared to these two state-of-the-art algorithms. TDFFD also proved to be more resistant to a reduced temporal resolution when decimating this synthetic sequence. Finally, this synthetic dataset was used to determine optimal settings of the TDFFD algorithm. Subsequently, TDFFDwas applied to a database of cardiac 3D US images of the left ventricle acquired from 9 healthy volunteers and 13 patients treated by Cardiac Resynchronization Therapy (CRT). On healthy cases, uniform strain patterns were observed over all myocardial segments, as physiologically expected. On all CRT patients, theimprovement in synchrony of regional longitudinal strain correlated with CRT clinical outcome as quanti ed by the reduction of end-systolic left ventricular volume at follow-up (6 and 12 months), showing the potential of the proposed algorithm for the assessment of CRT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Endovascular treatment of wide-neck bifurcation aneurysms often results in incomplete occlusion or aneurysm recurrence. The goals of this study were to compare results of coil embolization with or without the assistance of self-expandable stents and to examine how stents may influence neointima formation. MATERIALS AND METHODS: Wide-neck bifurcation aneurysms were constructed in 24 animals and, after 4-6 weeks, were randomly allocated to 1 of 5 groups: 1) coil embolization using the assistance of 1 braided stent (n = 5); 2) coil embolization using the assistance of 2 braided stents in a Y configuration (n = 5); 3) coil embolization without stent assistance (n = 6); 4) Y-stenting alone (n = 4); and 5) untreated controls (n = 4). Angiographic results were compared at baseline and at 12 weeks, by using an ordinal scale. Neointima formation at the neck at 12 weeks was compared among groups by using a semiquantitative grading scale. Bench studies were performed to assess stent porosities. RESULTS: Initial angiographic results were improved with single stent-assisted coiling compared with simple coiling (P = .013). Angiographic results at 12 weeks were improved with any stent assistance (P = .014). Neointimal closure of the aneurysm neck was similar with or without stent assistance (P = .908), with neointima covering coil loops but rarely stent struts. Y-stent placement alone had no therapeutic effect. Bench studies showed that porosities can be decreased with stent compaction, but a relatively stable porous transition zone was a limiting factor. CONCLUSIONS: Stent-assisted coiling may improve results of embolization by allowing more complete initial coiling, but these high-porosity stents did not provide a scaffold for more complete neointimal closure of aneurysms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To determine the pattern of extraocular muscle (EOM) paresis in incomplete vasculopathic third nerve palsies (3NP) that have normal pupillary function. METHODS: A retrospective study in a private practice and academic neuro-ophthalmic practice. Patients diagnosed with vasculopathic 3NP within 4 weeks of symptom onset were identified. The chart of each patient was reviewed to determine pupillary function and the pattern and degree of EOM and levator palpebrae paresis at the time of presentation. RESULTS: Of 55 patients with vasculopathic 3NP, 42 (76%) had normal pupillary function. Of these 42, 23 (55%) demonstrated an incomplete EOM palsy, defined as partially reduced ductions affecting all third nerve-innervated EOMs and levator (diffuse pattern) or partially reduced ductions that involved only some third nerve-innervated EOMs and levator (focal pattern). Twenty (87%) of these 23 patients showed a diffuse pattern of paresis; only three (13%) showed a focal pattern of paresis, one that affected only the superior rectus and levator muscles (superior division weakness). CONCLUSIONS: Based on our series, most patients with EOM/levator involvement in pupil-sparing, incomplete 3NP of vasculopathic origin have a diffuse pattern of paresis. In contrast, our review of the literature suggests that pupil-sparing 3NP of aneurysmal origin usually have a focal pattern of paresis. We propose that distinguishing these two patterns of EOM paresis may be helpful in differentiating between vasculopathic and aneurysmal 3NP. Future studies will be needed to confirm the clinical utility of this hypothesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECT: In 1999 we reported that 94% of unruptured middle cerebral artery (MCA) aneurysms managed prospectively between 1993 and 1997, according to a protocol favoring endovascular coiling, were best treated by surgical clipping. The goal of the current study was to delineate the most appropriate treatment option for unruptured MCA aneurysms today, considering the technical advances in imaging and in endovascular treatment. METHODS: 35 consecutive patients harboring 40 unruptured MCA aneurysms were treated between 1997 and December 2000. Patients with unruptured cerebral aneurysms are managed prospectively according to the same protocol as reported previously [1]: the primary treatment recommendation is endovascular packing with Guglielmi detachable coils (GDCs). Surgical clipping is recommended after failed attempt at coil placement or in the presence of angioanatomical features that contraindicate that type of endovascular therapy. RESULTS: One unruptured MCA aneurysm was treated by endovascular embolization, 37 unruptured MCA aneurysms were clipped, whereas 2 unruptured MCA aneurysms were trapped with simultaneous extracranial-intracranial revascularization. Postoperative angiography revealed complete exclusion of all aneurysms. Preservation of vascular permeability was demonstrated in all clip-reconstructed aneurysms, despite arterial branches frequently originating from the aneurysmal base. Cerebral revascularization of the distal MCA was successful in the 2 patients with giant aneurysms. None of the patients presented permanent disabling complications from the treatment of the unruptured MCA aneurysm. CONCLUSION: Despite major technical advances in imaging and in endovascular treatment of cerebral aneurysms, surgical clipping still is the most efficient treatment for unruptured MCA aneurysms at the beginning of the new millennium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the present study was to determine the frequency of the most common clinical features in patients with autosomal dominant polycystic kidney disease in a sample of the Brazilian population. The medical records of 92 patients with autosomal dominant polycystic kidney disease attended during the period from 1985 to 2003 were reviewed. The following data were recorded: age at diagnosis, gender, associated clinical manifestations, occurrence of stroke, age at loss of renal function (beginning of dialysis), and presence of a family history. The involvement of abdominal viscera was investigated by ultrasonography. Intracranial alterations were prospectively investigated by magnetic resonance angiography in 42 asymptomatic patients, and complemented with digital subtraction arteriography when indicated. Mean age at diagnosis was 35.1 ± 14.9 years, and mean serum creatinine at referral was 2.4 ± 2.8 mg/dL. The most frequent clinical manifestations during the disease were arterial hypertension (63.3%), lumbar pain (55.4%), an abdominal mass (47.8%), and urinary infection (35.8%). Loss of renal function occurred in 27 patients (mean age: 45.4 ± 9.5 years). The liver was the second organ most frequently affected (39.1%). Stroke occurred in 7.6% of the patients. Asymptomatic intracranial aneurysm was detected in 3 patients and arachnoid cysts in 3 other patients. In conclusion, the most common clinical features were lumbar pain, arterial hypertension, abdominal mass, and urinary infection, and the most serious complications were chronic renal failure and stroke. Both intracranial aneurysms and arachnoid cysts occurred in asymptomatic patients at a frequency of 7.14%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Symbolic dynamics is a branch of mathematics that studies the structure of infinite sequences of symbols, or in the multidimensional case, infinite grids of symbols. Classes of such sequences and grids defined by collections of forbidden patterns are called subshifts, and subshifts of finite type are defined by finitely many forbidden patterns. The simplest examples of multidimensional subshifts are sets of Wang tilings, infinite arrangements of square tiles with colored edges, where adjacent edges must have the same color. Multidimensional symbolic dynamics has strong connections to computability theory, since most of the basic properties of subshifts cannot be recognized by computer programs, but are instead characterized by some higher-level notion of computability. This dissertation focuses on the structure of multidimensional subshifts, and the ways in which it relates to their computational properties. In the first part, we study the subpattern posets and Cantor-Bendixson ranks of countable subshifts of finite type, which can be seen as measures of their structural complexity. We show, by explicitly constructing subshifts with the desired properties, that both notions are essentially restricted only by computability conditions. In the second part of the dissertation, we study different methods of defining (classes of ) multidimensional subshifts, and how they relate to each other and existing methods. We present definitions that use monadic second-order logic, a more restricted kind of logical quantication called quantifier extension, and multi-headed finite state machines. Two of the definitions give rise to hierarchies of subshift classes, which are a priori infinite, but which we show to collapse into finitely many levels. The quantifier extension provides insight to the somewhat mysterious class of multidimensional sofic subshifts, since we prove a characterization for the class of subshifts that can extend a sofic subshift into a nonsofic one.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: La DSA es el método de elección para el seguimiento de pacientes con aneurismas intracraneales embolizados; esta se puede asociar a complicaciones incapacitantes o mortales. La MRA se ha propuesto como método alternativo por menor costo y menos morbi-mortalidad, aunque su desempeño diagnóstico permanece en discusión debido al desarrollo de nuevos protocolos, resonadores más potentes y nuevas aplicaciones de la DSA. Metodología: Exploramos la literatura hasta la actualidad y comparamos el desempeño diagnóstico de la MRA con la DSA para detectar flujo residual posterior a la embolización terapéutica de aneurismas intracraneales. Realizamos una revisión sistemática de la literatura y meta-análisis basados en 34 artículos detectados en la búsqueda que incluyó las bases de datos PubMed, Scopus, ScIELO y BVS. Resultados: La TOF-MRA demostró sensibilidad de 86.8% (84.3%-89.1%) y especificidad de 91.2% (89%-93.1%); la SROC para TOF-MRA demostró un AUC de 0.95. El desempeño de la CE-MRA demostró sensibilidad de 88.1% (84.6%-91.1%) y especificidad de 89.1% (85.7%-91.9%); la SROC presentó una AUC de 0.93. El análisis estratificado por potencia del resonador encontró que la TOF-MRA tiene mejor desempeño con el resonador de 3T, aunque no es estadísticamente significativo. La concordancia interobservador con TOF-MRA y CE-MRA fue moderada a muy buena. Discusión: El desempeño diagnóstico de la MRA en el seguimiento de aneurismas intracraneales embolizados demostró ser bueno, con sensibilidad mayor a 84%, siendo ligeramente mejor con TOF-MRA, sin lograr reemplazar la DSA. Sin embargo, los resultados deben ser evaluados con precaución por la heterogeneidad de los resultados de los estudios incluidos. (Abreviaturas: DSA: Angiografía por Sustracción Digital; MRA: Angiografía por Resonancia Magnética; TOF-MRA: Angiorresonancia por Tiempo de Vuelo; CE-MRA: Angiorresonancia contrastada).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este texto representa el esfuerzo combinado de dos lógicos, dos filósofos y un lingüista. Esta empresa fue inspirada por la convicción de los autores de que la lógica y el lenguaje son inseparables, en particular en lo que respecta al análisis del significado. Una región interdisciplinaria emerge entre los límites de la filosofía, la lógica y la lingüística. Lógica, lenguaje y significado: lógica intensional y gramática lógica es una introducción a este campo, el cual aplica los sistemas lógico-formales al estudio del significado del lenguaje natural. El libro comienza con una introducción de los distintos principios de la semántica intensional y luego presenta varias lógicas intensionales, tales como la lógica proposicional modal, la lógica de predicados modal y la lógica temporal. También introduce la teoría de tipos, la lambda-abstracción y la sintaxis categorial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An ultra-fast and improved analytical methodology based on microextraction by packed sorbent (MEPS) combined with ultra-performance LC (UPLC) was developed and validated for determination of (E)-resveratrol in wines. Important factors affecting the performance of MEPS such as the type of sorbent material (C2, C8, C18, SIL, and M1), number of extraction cycles, and sample volume were studied. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (50–250mL) in one extraction cycle (extract–discard) and in a short time period (about 3 min for the entire sample preparation step). (E)-Resveratrol was eluted by 1 250mL of the mixture containing 95% methanol and 5% water, and the separation was carried out on a highstrength silica HSS T3 analytical column (100 mm 2.1 mm, 1.8mm particle size) using a binary mobile phase composed of aqueous 0.1% formic acid (eluent A) and methanol (eluent B) in the gradient elution mode (10 min of total analysis). The method was fully validated in terms of linearity, detection (LOD) and quantication (LOQ) limits, extraction yield, accuracy, and inter/intra-day precision, using a Madeira wine sample (ET) spiked with (E)-resveratrol at concentration levels ranging from 5 to 60mg/mL. Validation experiments revealed very good recovery rate of 9575.8% RSD, good linearity with r2 values 40.999 within the established concentration range, excellent repeatability (0.52%), and reproducibility (1.67%) values (expressed as RSD), thus demonstrating the robustness and accuracy of the MEPSC8/UPLC-photodiode array (PDA) method. The LOD of the method was 0.21mg/mL, whereas the LOQ was 0.68mg/mL. The validated methodology was applied to 30 commercial wines (24 red wines and six white wines) from different grape varieties, vintages, and regions. On the basis of the analytical validation, the MEPSC8/UPLC-PDA methodology shows to be an improved, sensitive, and ultra-fast approach for determination of (E)-resveratrol in wines with high resolving power within 6 min.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Our aim was to evaluate the relationship between serum C-reactive protein (CRP) levels and the neurological prognosis and development of vasospasm in patients with aneurysmal subarachnoid hemorrhage (aSAH). Methods: Eighty-two adult patients with aSAH diagnoses were prospectively evaluated. Glasgow Coma Scale (GCS) score, Hunt and Hess grade, Fisher grade, cranial CT scans, digital subtraction angiography studies and daily neurological examinations were recorded. Serial serum CRP measurements were obtained daily between admission and the tenth day. Glasgow Outcome Scale (GOS) and the modified Rankin Scale (mRS) were used to assess the prognosis. Results: Serum CRP levels were related to severity of aSAH. Patients with lower GCS scores and higher Hunt and Hess and Fisher grades presented statistically significant higher serum CRP levels. Patients with higher serum CRP levels had a less favorable prognosis. Conclusions: Increased serum CRP levels were strongly associated with worse clinical prognosis in this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die S-adenosyl-L-Homocysteinhydrolase (AHCY)-Defizienz ist eine seltene autosomal rezessive Erbkrankheit, bei der Mutationen im AHCY-Gen die Funktionsfähigkeit des kodierten Enzyms beeinträchtigen. Diese Krankheit führt zu Symptomen wie Entwicklungsverzögerungen, mentaler Retardierung und Myopathie. In der vorliegenden Arbeit wurde der Einfluss der AHCY-Defizienz auf die Methylierung der DNA in Blutproben und Fibroblasten von Patienten mit AHCY-Defizienz, sowie in HEK293- und HepG2-Zelllinien mit AHCY-Knockdown untersucht. Der gesamtgenomische Methylierungsstatus wurde mit Hilfe des MethylFlash ™ Methylated DNA Quantication Kit (Epigentek) bei drei Patienten-Blutproben festgestellt. In den Blutproben von sieben Patienten und Fibroblasten von einem Patienten wurde die Methylierung von DMRs sieben geprägter Gene (GTL2, H19, LIT1, MEST, NESPAS, PEG3, SNRPN) und zwei repetitiver Elemente (Alu, LINE1) mittels Bisulfit-Pyrosequenzierung quantifiziert und durch High Resolution Melting-Analyse bestätigt. Zusätzlich wurde eine genomweite Methylierungsanalyse mit dem Infinium® HumanMethylation450 BeadChip (Illumina) für vier Patientenproben durchgeführt und die Expression von AHCY in Fibroblasten mittels Expressions-qPCR und QUASEP-Analyse untersucht. Die Methylierungsanalysen ergaben eine Hypermethylierung der gesamtgenomischen DNA und stochastische Hypermethylierungen von DMRs geprägter Gene bei einigen Patienten. Die HEK293- und HepG2-Zelllinien wiesen dagegen hauptsächlich stochastische Hypomethylierungen an einigen DMRs geprägter Gene und LINE1-Elementen auf. Die genomweite Methylierungsarray-Analyse konnte die Ergebnisse der Bisulfit-Pyrosequenzierung nicht bestätigen. Die Expressionsanalysen der AHCY-defizienten Fibroblasten zeigten eine verminderte Expression von AHCY, wobei beide Allele etwa gleich stark transkribiert wurden. Die Ergebnisse deuten darauf hin, dass die AHCY-Defizienz eine gute Modellerkrankung für die Untersuchung biologischer Konsequenzen von Methylierungsstörungen im Rahmen der Epigenetik-Forschung sein könnte. Sie ist unseres Wissens die erste monogene Erkrankung mit symptomaler DNA-Hypermethylierung beim Menschen.