878 resultados para Foot Measurement Evaluation
Resumo:
An electrochemical technique for the real-time detection of hydrogen peroxide (H2O2) was employed to describe respiratory burst activity (RBA) of phagocytes in plasma which can be used to evaluate the ability of immune system and disease resistance. The method is based upon the electric current changes, by redox reaction on platinum electrode of extracellular hydrogen peroxide (H2O2) released from phagocytes stimulated by the zymosan at 680 mV direct current (d.c.). Compared with the control, activation of respiratory burst by zymosan particles results in a high amperometric response, and a current peak was obtained during the whole monitoring process. The peak current was proved by addition Of Cu2+ and other controls, to be the result of intense release of H2O2 from phagocytes. The peak area was calculated and used to evaluate the quantity of effective H2O2, which represents the quantity of H2O2 beyond the clearance of related enzymes in plasma. According to Faraday's law, the phagocytes' ability of prawns to generate effective H2O2 was evaluated from 1.253 x 10(-14) mol/cell to 6.146 x 10(-14) mol/cell, and carp from 1.689 x 10(-15) Mol/Cell to 7.873 x 10(-1)5 mol/cell. This method is an acute and quick detection of extracellular effective H2O2 in plasma and reflects the capacity of phagocytes under natural conditions, which could be applied for selecting species and parents with high immunity for breeding in aquaculture. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Aim: To develop and evaluate the psychometric properties of an instrument for the measurement of self-neglect (SN).Conceptual Framework: An elder self-neglect (ESN) conceptual framework guided the literature review and scale development. The framework has two key dimensions physical/psycho-social and environmental and seven sub dimensions which are representative of the factors that can contribute to intentional and unintentional SN. Methods: A descriptive cross-sectional design was adopted to achieve the research aim. The study was conducted in two phases. Phase 1 involved the development of the questionnaire content and structure. Phase 2 focused on establishing the psychometric properties of the instrument. Content validity was established by a panel of 8 experts and piloted with 9 health and social care professionals. The instrument was subsequently posted with a stamped addressed envelope to 566 health and social care professionals who met specific eligibility criteria across the four HSE areas. A total of 341 questionnaires were returned, a response rate of 60% and 305 (50%) completed responses were included in exploratory factor analysis (EFA). Item and factor analyses were performed to elicit the instruments underlying factor structure and establish preliminary construct validity. Findings: Item and factor analyses resulted in a logically coherent, 37 items, five factor solution, explaining 55.6% of the cumulative variance. The factors were labelled: ‘Environment’, ‘Social Networks’, ‘Emotional and Behavioural Liability’, ‘Health Avoidance’ and ‘Self-Determinism’. The factor loadings were >0.40 for all items on each of the five subscales. Preliminary construct validity was supported by findings. Conclusion: The main outcome of this research is a 37 item Self-Neglect (SN-37) measurement instrument that was developed by EFA and underpinned by an ESN conceptual framework. Preliminary psychometric evaluation of the instrument is promising. Future work should be directed at establishing the construct and criterion related validity of the instrument.
Resumo:
There is little agreement as to the most appropriate thermometer, the anatomical site to carry out temperature measurement in children with cancer, or the type of thermometer preferred by the patients. The authors carried out this study to assess temperature measurement in children with cancer who were admitted for febrile episodes. The body temperatures of children with cancer who were admitted consecutively between January and October 2005 to the paediatric department because of febrile episodes were measured on admission and over the next 24–36 hours using an electronic thermometer sublingually as the standard reference site. These measurements were compared with those obtained with two ear-based thermometers, a forehead thermometer, and from the axilla (representing current practice). The parents were asked about the type of thermometer they used at home and the children were asked about the type of thermometer they preferred. There were 34 admissions during this period, of which 19 (56%) were confirmed as febrile. Altogether, 108 sets of temperature measurements were obtained, producing a total of 540 measurements from these admissions. Measurements with the two ear-based thermometers in febrile children achieved higher sensitivity than that with axillary and the forehead measurements. The ear-based thermometer was the most common type used at home while the forehead thermometer was the one preferred by the children. In conclusion, ear-based temperature measurements in febrile children were more accurate than axillary and forehead temperature measurements. The current practice of axillary temperature measurement needs to be re-considered.
Resumo:
The purpose of this research note is to demonstrate how an individualised quality of life instrument could be adapted to provide a more accurate estimate of the impact of a social service on a person’s quality of life. An increase in quality of life between the start and end of a service is often taken as an indication that the service impacted positively on quality of life. The modifications to the quality of life instrument suggested in this paper show that this assumption is not always accurate and should be questioned directly.
Resumo:
Policy-based network management (PBNM) paradigms provide an effective tool for end-to-end resource
management in converged next generation networks by enabling unified, adaptive and scalable solutions
that integrate and co-ordinate diverse resource management mechanisms associated with heterogeneous
access technologies. In our project, a PBNM framework for end-to-end QoS management in converged
networks is being developed. The framework consists of distributed functional entities managed within a
policy-based infrastructure to provide QoS and resource management in converged networks. Within any
QoS control framework, an effective admission control scheme is essential for maintaining the QoS of
flows present in the network. Measurement based admission control (MBAC) and parameter basedadmission control (PBAC) are two commonly used approaches. This paper presents the implementationand analysis of various measurement-based admission control schemes developed within a Java-based
prototype of our policy-based framework. The evaluation is made with real traffic flows on a Linux-based experimental testbed where the current prototype is deployed. Our results show that unlike with classic MBAC or PBAC only schemes, a hybrid approach that combines both methods can simultaneously result in improved admission control and network utilization efficiency
Resumo:
This paper reports on a Field Programmable Gate Array (FPGA) implementation as well as prototyping for real-time testing of a low complexity high efficiency decimation filter processor which is deployed in conjunction with a custom built low-power jitter insensitive Continuous Time (CT) Sigma-Delta (Σ-Δ) Modulator to measure and assess its performance. The CT Σ-Δ modulator/decimation filter cascade can be used in integrated all-digital microphone interfaces for a variety of applications including mobile phone handsets, wireless handsets as well as other applications requiring all-digital microphones. The work reported here concentrates on the design and implementation as well as prototyping on a Xilinx Spartan 3 FPGA development system and real-time testing of the decimation processing part deploying All-Pass based structures to process the bit stream coming from CT Σ-Δ modulator hence measuring in real-time and fully assessing the modulator's performance.
Resumo:
Resumen tomado de la publicación. Monográfico titulado: economía de la educación
Resumo:
The concentrations of sulfate, black carbon (BC) and other aerosols in the Arctic are characterized by high values in late winter and spring (so-called Arctic Haze) and low values in summer. Models have long been struggling to capture this seasonality and especially the high concentrations associated with Arctic Haze. In this study, we evaluate sulfate and BC concentrations from eleven different models driven with the same emission inventory against a comprehensive pan-Arctic measurement data set over a time period of 2 years (2008–2009). The set of models consisted of one Lagrangian particle dispersion model, four chemistry transport models (CTMs), one atmospheric chemistry-weather forecast model and five chemistry climate models (CCMs), of which two were nudged to meteorological analyses and three were running freely. The measurement data set consisted of surface measurements of equivalent BC (eBC) from five stations (Alert, Barrow, Pallas, Tiksi and Zeppelin), elemental carbon (EC) from Station Nord and Alert and aircraft measurements of refractory BC (rBC) from six different campaigns. We find that the models generally captured the measured eBC or rBC and sulfate concentrations quite well, compared to previous comparisons. However, the aerosol seasonality at the surface is still too weak in most models. Concentrations of eBC and sulfate averaged over three surface sites are underestimated in winter/spring in all but one model (model means for January–March underestimated by 59 and 37 % for BC and sulfate, respectively), whereas concentrations in summer are overestimated in the model mean (by 88 and 44 % for July–September), but with overestimates as well as underestimates present in individual models. The most pronounced eBC underestimates, not included in the above multi-site average, are found for the station Tiksi in Siberia where the measured annual mean eBC concentration is 3 times higher than the average annual mean for all other stations. This suggests an underestimate of BC sources in Russia in the emission inventory used. Based on the campaign data, biomass burning was identified as another cause of the modeling problems. For sulfate, very large differences were found in the model ensemble, with an apparent anti-correlation between modeled surface concentrations and total atmospheric columns. There is a strong correlation between observed sulfate and eBC concentrations with consistent sulfate/eBC slopes found for all Arctic stations, indicating that the sources contributing to sulfate and BC are similar throughout the Arctic and that the aerosols are internally mixed and undergo similar removal. However, only three models reproduced this finding, whereas sulfate and BC are weakly correlated in the other models. Overall, no class of models (e.g., CTMs, CCMs) performed better than the others and differences are independent of model resolution.
Resumo:
This Thesis project is a part of the all-round automation of production of concentrating solar PV/T systems Absolicon X10. ABSOLICON Solar Concentrator AB has been invented and started production of the prospective solar concentrated system Absolicon X10. The aims of this Thesis project are designing, assembling, calibrating and putting in operation the automatic measurement system intended to evaluate the shape of concentrating parabolic reflectors.On the basis of the requirements of the company administration and needs of real production process the operation conditions for the Laser testing rig were formulated. The basic concept to use laser radiation was defined.At the first step, the complex design of the whole system was made and division on the parts was defined. After the preliminary conducted simulations the function and operation conditions of the all parts were formulated.At the next steps, the detailed design of all the parts was conducted. Most components were ordered from respective companies. Some of the mechanical components were made in the workshop of the company. All parts of the Laser-testing rig were assembled and tested. Software part, which controls the Laser-testing rig work, was created on the LabVIEW basis. To tune and test software part the special simulator was designed and assembled.When all parts were assembled in the complete system, the Laser-testing rig was tested, calibrated and tuned.In the workshop of Absolicon AB, the trial measurements were conducted and Laser-testing rig was installed in the production line at the plant in Soleftea.
Resumo:
This Thesis project is a part of the research conducted in Solar industry. ABSOLICON Solar Concentrator AB has invented and started production of the prospective solar concentrated system Absolicon X10. The aims of this Thesis project are designing, assembling, calibrating and putting in operation the automatic measurement system intended to evaluate distribution of density of solar radiation in the focal line of the concentrated parabolic reflectors and to measure radiation from the artificial source of light being a calibration-testing tool.On the basis of the requirements of the company’s administration and needs of designing the concentrated reflectors the operation conditions for the Sun-Walker were formulated. As the first step, the complex design of the whole system was made and division on the parts was specified. After the preliminary conducted simulation of the functions and operation conditions of the all parts were formulated.As the next steps, the detailed design of all the parts was made. Most components were ordered from respective companies. Some of the mechanical components were made in the workshop of the company. All parts of the Sun-Walker were assembled and tested. The software part, which controls the Sun-Walker work and conducts measurements of solar irradiation, was created on the LabVIEW basis. To tune and test the software part, the special simulator was designed and assembled.When all parts were assembled in the complete system, the Sun-Walker was tested, calibrated and tuned.