986 resultados para First-derivative UV spectrophotometry
Resumo:
The objective of this research was to develop and validate an alternative analytical method for quantitative determination of levofloxacin in tablets and injection preparations. The calibration curves were linear over a concentration range from 3.0 to 8.0 μg mL-1. The relative standard deviation was below 1.0% for both formulations and average recovery was 101.42 ± 0.45% and 100.34 ± 0.85% for tablets and injection formulations, respectively. The limit of detection and limit of quantitation were 0.08 and 0.25 μg mL-1, respectively. It was concluded that the developed method is suitable for the quality control of levofloxacin in pharmaceuticals formulations.
Resumo:
For determination of aliskiren in commercial samples, an analytical UV spectrophotometric method was developed and validate according to ICH guideline. The method was linear in the range between 40 and 100 μg mL-1 (r² = 0.9997, n = 7) and exhibited suitable specificity, accuracy, precision, and robustness. It is simple, it has low cost, and it has low use polluting reagents. Therefore, the proposed method was successfully applied for the assay and dissolution studies of aliskiren in tablet dosage forms, and the results were compared to a validated RP-LC method, showing non-significant difference (P > 0.05).
Validação de método espectrofotométrico na região do UV para quantificação de famotidina em cápsulas
Resumo:
This work describes the validation of a method for quantification of famotidine in capsules by UV spectrophotometry using as solvents buffer solution at pH 2.5 and buffer solution at pH 4.5. The results show that the method is practical, selective, accurate, precise and linear from 10.0 to 25.0 µg/mL of famotidine in both solvents. However, a variance analysis showed a lower mean percentage of famotidine when buffer at pH 2.5 is used. This effect was attributed to the instability of famotidine in acidic media. Therefore, the use of pH 4.5 buffer was considered suitable for analysis of famotidine in capsules.
Resumo:
The simultaneous determination of two or more active components in pharmaceutical preparations, without previous chemical separation, is a common analytical problem. Published works describe the determination of AZT and 3TC separately, as raw material or in different pharmaceutical preparations. In this work, a method using UV spectroscopy and multivariate calibration is described for the simultaneous measurement of 3TC and AZT in fixed dose combinations. The methodology was validated and applied to determine the AZT+3TC contents in tablets from five different manufacturers, as well as their dissolution profile. The results obtained employing the proposed methodology was similar to methods using first derivative technique and HPLC.
Resumo:
This paper reports the development and validation of a new analytical method using UV spectrophotometry to quantify carvedilol (CRV) in hydrophilic matrices and raw material. This method was shown to be linear, accurate, precise, robust and to have adequate limits of quantification and detection (LQ and LD, respectively), allowing its use in the dissolution test of hydrophilic matrices. The content of CRV determined through this method was compared with two previously validated methods based on the reference techniques of High Performance Liquid Chromatography (HPLC) and Potentiometric Titrations (PT). ANOVA confirmed the equivalence of these methods, showing no significant differences.
Resumo:
The effects of microwave heating on the oxidative stability of refined canola, corn and soybean oils were determined by absorptivity in the UV spectrum and by chemical analysis (peroxide and acid values). Samples were heated in a microwave oven (800 W, 2,450 MHz) for 0 to 36 min. Microwave heating produced oxidative degradation in the three oils. Absorptivity at 232 and 270 nm increased gradually with an increase in microwave exposure time (0-36 min) for canola, corn and soybean oils. Values of absorptivity at 232 nm increased from 4.812, 3.568 and 4.183 to 10.579, 12.874 and 15.950 after 36 min of heating canola, corn and soybean oil, respectively. The absorptivity at 232nm, due to the formation of conjugated dienes, was a good index for measuring the degradation of microwaved samples. UV scanning (220 - 320 nm) detected alterations in the spectrum of microwaved samples. Acid value also increased within 36 min of heating for all oils. Peroxide value showed a significant difference (P<0.05) in the initial stage of heating (0-6 min) for all oils. After this period it could not be correlated with absorptivity at 232 nm, due to the instability of hydroperoxides at high temperatures.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This work is combined with the potential of the technique of near infrared spectroscopy - NIR and chemometrics order to determine the content of diclofenac tablets, without destruction of the sample, to which was used as the reference method, ultraviolet spectroscopy, which is one of the official methods. In the construction of multivariate calibration models has been studied several types of pre-processing of NIR spectral data, such as scatter correction, first derivative. The regression method used in the construction of calibration models is the PLS (partial least squares) using NIR spectroscopic data of a set of 90 tablets were divided into two sets (calibration and prediction). 54 were used in the calibration samples and the prediction was used 36, since the calibration method used was crossvalidation method (full cross-validation) that eliminates the need for a validation set. The evaluation of the models was done by observing the values of correlation coefficient R 2 and RMSEC mean square error (calibration error) and RMSEP (forecast error). As the forecast values estimated for the remaining 36 samples, which the results were consistent with the values obtained by UV spectroscopy
Resumo:
The orb-web spiders are polyphagous animals in which the web plays a very important role in the capture of preys; oily droplets usually cover the capture-web of the spider Nephila clavipes and seem to be of great importance for prey capture. The knowledge of the chemical composition of these droplets is necessary to understand the function of this adhesive material in web mechanics and prey capture. A novel subclass of spider toxins, tetrahydro-beta-carboline, was identified among the weaponry of compounds present inside of oily droplets. This type of alkaloid is not common among the natural compounds of spider toxins. Apparently, when the prey arthropods get caught by the spider web, their bodies are covered with many adhesive oily droplets, which disrupt delivering the tetrahydro-beta-carboline to the direct contact with the prey integument. Toxicity assays demonstrated a potent lethal effect of the alkaloid toxin to the spider preys; topical applications of the teirahydro-beta-carboline at first caused clear signs of neurotoxicity, followed by the death of preys. The structure of the major component, a tetrahydro-beta-carboline, among the alkaloid toxins was elucidated by means of UV spectrophotometry, ESI mass spectrometry, H-1-NMR spectroscopy, and high-resolution mass spectrometry. The structure of the natural toxin was determined as 1-(2-guanidinoethyl)-1,2,3,4-tetrahydro-6-hydroxymethyl)-beta-carboline; the investigation of the pharmacological properties and neurotoxic actions of this compound may be used in the future as reference for the development of new drugs to be applied at level of pest control in agriculture.
Resumo:
Diarylpropenamine derivatives are a class of compounds which have been evaluated as potential drug candidates. Here a specific and reproducible HPLC method for the determination of cis- and trans-isomers of the unsubstituted derivative, 3-(4'-bromo-[1,1'-biphenyl]-4-yl)-3-(4-X-phenyl-N,N-dimethyl-2-propen-1-amine (I, where X=H) in feces is described. The analyte I and internal standard, nitro derivative (II, where X=NO2), were isolated from the basified biological matrix using a liquid-liquid extraction with ethyl acetate followed by a solid-phase procedure performed on a silica cartridge. The organic phase was evaporated to dryness, the residue was reconstituted in mobile phase and injected into the HPLC system. The analytes were eluted with ethyl acetate-hexane-triethylamine (59:40:1) in HPLC column (silica) and detected by UV spectrophotometry at 272 nm. Linearity, precision and accuracy data for feces standards after extraction were acceptable. The method has been applied to analyses of feces samples from rats dosed with I, in which it could be anticipated that fecal excretion is quantitatively the major route for I elimination. Copyright (C) 1999 Elsevier Science B.V.
Resumo:
A combined theoretical and experimental study to elucidate the molecular mechanism for the Grob fragmentation of different (N-halo)-2-amino cyclocarboxylates with the nitrogen atom in exocyclic position: (N-Cl)-2-amino cyclopropanecarboxylate (1), (N-Cl)-2-amino cyclobutanecarboxylate (2), (N-Cl)-2-amino cyclopentanecarboxylate (3) and (N-Cl)-2-amino cyclohexanecarboxylate (4), and the corresponding acyclic compounds, (N-Cl)-2-amino isobutyric acid (A), (N-Cl)-2-amino butyric acid (B), has been carried out. The kinetics of decomposition for these compounds and related bromine derivatives were experimentally determined by conventional and stopped-flow UV spectrophotometry. The reaction products have been analyzed by GC and spectrophotometry. Theoretical analysis is based in the localization of stationary points (reactants and transition structures) on the potential energy surface. Calculations were carried out at B3LYP/6-31+G* and MP2/6-31+G* computing methods in the gas phase, while solvent effects have been included by means the self-consistent reaction field theory, PCM continuum model, at MP2/6-31+G* and MP4/6-31+G*//MP2/6-31+G* calculation levels. Based on both experimental and theoretical results, the different Grob fragmentation processes show a global synchronicity index close to 0.9, corresponding to a nearly concerted process. At the TSs, the N-Cl bond breaking is more advanced than the C-C cleavage process. An antiperiplanar configuration of these bonds is reached at the TSs, and this geometrical arrangement is the key factor governing the decomposition. In the case of 1 and 2 the ring strain prevents this spatial disposition, leading to a larger value of the activation barrier. Natural population analysis shows that the polarization of the N-Cl and C-C bonds along the bond-breaking process can be considered the driving force for the decomposition and that a negative charge flows from the carboxylate group to the chlorine atom to assist the reaction pathway. A comparison of theoretical and experimental results shows the relevance of calculation level and the inclusion of solvent effects for determining accurate unimolecular rate coefficients for the decomposition process. © 2002 Published by Elsevier Science B.V.
Resumo:
Pós-graduação em Ciências Farmacêuticas - FCFAR
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this paper, we describe an algorithm that automatically detects and labels peaks I - VII of the normal, suprathreshold auditory brainstem response (ABR). The algorithm proceeds in three stages, with the option of a fourth: ( 1) all candidate peaks and troughs in the ABR waveform are identified using zero crossings of the first derivative, ( 2) peaks I - VII are identified from these candidate peaks based on their latency and morphology, ( 3) if required, peaks II and IV are identified as points of inflection using zero crossings of the second derivative and ( 4) interpeak troughs are identified before peak latencies and amplitudes are measured. The performance of the algorithm was estimated on a set of 240 normal ABR waveforms recorded using a stimulus intensity of 90 dBnHL. When compared to an expert audiologist, the algorithm correctly identified the major ABR peaks ( I, III and V) in 96 - 98% of the waveforms and the minor ABR peaks ( II, IV, VI and VII) in 45 - 83% of waveforms. Whilst peak II was correctly identified in only 83% and peak IV in 77% of waveforms, it was shown that 5% of the peak II identifications and 31% of the peak IV identifications came as a direct result of allowing these peaks to be found as points of inflection. Copyright (C) 2005 S. Karger AG, Basel.