996 resultados para Digital speckle pattern interferometry
Resumo:
An 8-year-old female neutered Siamese cat was presented with a recent history of incomplete excision of an apocrine gland adenocarcinoma from the palmar aspect of the right antebrachium, just proximal to the carpal joint. There was no evidence of metastasis. Wide surgical excision of the previous surgery site was performed resulting in a soft tissue defect. Partial reconstruction was achieved using digital pad transposition of the first digit (dewclaw), forming a local axial pattern flap that was transposed into the adjacent defect. The remaining defect was closed by primary apposition. The skin flap healed successfully. Some breakdown of the skin closed by primary apposition necessitated open wound management. The cosmetic and functional result of the first digital pad transposition was considered excellent, rendering it a useful means to reconstruct soft tissue defects in the carpal region.
Resumo:
Software for pattern recognition of the larvae of mosquitoes Aedes aegypti and Aedes albopictus, biological vectors of dengue and yellow fever, has been developed. Rapid field identification of larva using a digital camera linked to a laptop computer equipped with this software may greatly help prevention campaigns.
Resumo:
Magdeburg, Univ., Fak. für Naturwiss., Diss., 2009
Resumo:
Amb una plantilla, hem elaborat uns materials docents -l'objecte d'estudi dels quals és l’Estatut d'Autonomia de Catalunya de 2006, des d'una perspectiva jurídica -, que corresponen fonamentalment a l’assignatura “Institucions Polítiques de Catalunya” de 4rt. curs de la llicenciatura de Dret de la UAB. Els materials s’han penjat al web http://www.institucionspolitiques.com. L' objectiu de l’acció docent ha estat consolidar una eina interactiva, que fomenti la creativitat i el treball cooperatiu de l’estudiant, que permeti un rol més actiu del professorat, i finalment, es faciliti l’adaptació docent a l’espai europeu d’educació superior. L’experiència s'ha completat amb l’ús del mètode bimodal -campus virtual de la UAB -, amb visites a institucions públiques i amb l’assistència periòdica com a públic a programes de televisió de continguts relacionats amb la matèria. La plantilla per a desenvolupar els diversos temes del programa ha estat la següent: 1.- Redacció del tema; 2.- Visualització de conceptes: quadres sinòptics, esquemes, gràfics; 3.-Bibliografia bàsica. 4.-Legislació i jurisprudència. 5.-Text reproduït. 6.-Qüestions.7.-Temes per al debat. 8.-Test. 9.-Materials complementaris audiovisuals. 10.-Enllaços útils a la xarxa. L'experiència s’ha desenvolupat els dos darrers cursos acadèmics: 2006/07 i 2007/08, i ha girat entorn de l'elaboració i aplicació dels materials elaborats. Ha estat teòrica i pràctica a la vegada. S'ha prestat especial atenció a la feina de l'alumnat fora de l'aula, amb el conseqüent estudi previ i col·laboració en l’elaboració de materials. Cal destacar també que hem aconseguit augmentar la participació de l'alumnat a l’aula, i d'aquesta manera el rol del professor ha esdevingut més dinàmic. Els materials han permès un fàcil i ràpid accés dels estudiants, amb l’objectiu de gaudir d’unes sessions presencials més interactives, i s'ha connectat la Universitat amb la societat, a més de desenvolupar actituds cíviques o de consciència de país en una matèria tan sensible com és l'estudi del dret públic de Catalunya.
Resumo:
Purpose: To phenotype a large 3 generation Swiss family with pattern dystrophy and to report a successful result of treatment with ranibizumab of a subfoveal choroidal neovascularisation (CNV) associated with pattern dystrophy in 1 patient Patients and methods: 4 affected and 3 unaffected patients (3 female 4 male, age range: 19 - 80 years) were assessed with a complete ophthalmologic examination. AF images were taken using Heidelberg Retina Angiograph and the digital color photos, fluorescein angiogragraphy (FFA) using the same TOPCON 501 camera. Electroretinogram (full-field and multifocal) was performed in 1 affected patient. One 48 years old patient developed a subfoveal CNV, which was treated with 2 injections of ranibizumab, at 3 months interval. Blood sample was taken for molecular analysis (screening of the gene RDS). Results: Two patients had a typical fundoscopic appearance of pattern dystrophy with butterfly shaped deposit at the fovea and some peripheral flecks, as shown with AF imaging.. Two others affected patients had a more unusual appearance with some macular atrophy in one or both eyes, surrounded by flecks. The visual acuity ranged from 1.0 to 0.1 according to Snellen EDTRS chart. The patient with subfoveal CNV presented a drop of vision form 1.0 to 0.6 within 10 days prior to the diagnosis and also reported some metamorphopsia. FFA and optical computerized tomography (OCT) confirmed a classic CNV. After the 1st injection her vision improved to 1.0 but persistent metamorphopsia and fluid on OCT motivated a second injection. One month after the second injection the OCT was flat and the patient had no symptoms. The results of RDS screening will be presented at the meeting. Conclusion: We present a family with pattern dystrophy, with some members having an unusual fundus appearance, which was mistaken for an early onset dry AMD. The AF imaging is a useful tool in diagnosing this condition. A CNV associated with pattern dystrophy a rare. This is the first report of a successful treatment of the CNV with anti-VEGF intravitreal injections.
Resumo:
In this article we present a method to achieve tri-dimensional contouring of macroscopic objects. A modified reference wave speckle interferometer is used in conjunction with a source of reduced coherence. The depth signal is given by the envelope of the interference signal, directly determined by the coherence length of the source. Fringes are detected in the interferogram obtained by a single shot and are detected by means of adequate filtering. With the approach based on off-axis configuration, a contour line can be extracted from a single acquisition, thus allowing to use the system in harsh environment. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
BACKGROUND AND STUDY AIMS: The current gold standard in Barrett's esophagus monitoring consists of four-quadrant biopsies every 1-2 cm in accordance with the Seattle protocol. Adding brush cytology processed by digital image cytometry (DICM) may further increase the detection of patients with Barrett's esophagus who are at risk of neoplasia. The aim of the present study was to assess the additional diagnostic value and accuracy of DICM when added to the standard histological analysis in a cross-sectional multicenter study of patients with Barrett's esophagus in Switzerland. METHODS: One hundred sixty-four patients with Barrett's esophagus underwent 239 endoscopies with biopsy and brush cytology. DICM was carried out on 239 cytology specimens. Measures of the test accuracy of DICM (relative risk, sensitivity, specificity, likelihood ratios) were obtained by dichotomizing the histopathology results (high-grade dysplasia or adenocarcinoma vs. all others) and DICM results (aneuploidy/intermediate pattern vs. diploidy). RESULTS: DICM revealed diploidy in 83% of 239 endoscopies, an intermediate pattern in 8.8%, and aneuploidy in 8.4%. An intermediate DICM result carried a relative risk (RR) of 12 and aneuploidy a RR of 27 for high-grade dysplasia/adenocarcinoma. Adding DICM to the standard biopsy protocol, a pathological cytometry result (aneuploid or intermediate) was found in 25 of 239 endoscopies (11%; 18 patients) with low-risk histology (no high-grade dysplasia or adenocarcinoma). During follow-up of 14 of these 18 patients, histological deterioration was seen in 3 (21%). CONCLUSION: DICM from brush cytology may add important information to a standard biopsy protocol by identifying a subgroup of BE-patients with high-risk cellular abnormalities.
Resumo:
Structural settings and lithological characteristics are traditionally assumed to influence the development of erosional landforms, such as gully networks and rock couloirs, in steep mountain rock basins. The structural control of erosion of two small alpine catchments of distinctive rock types is evaluated by comparing the correspondences between the orientations of their gullies and rock couloirs with (1) the sliding orientations of potential slope failures mechanisms, and (2) the orientation of the maximum joint frequency, this latter being considered as the direction exploited primarily by erosion and mass wasting processes. These characteristic orientations can be interpreted as structural weaknesses contributing to the initiation and propagation of erosion. The morphostructural analysis was performed using digital elevation models and field observations. The catchment comprised of magmatic intrusive rocks shows a clear structural control, mostly expressed through potential wedges failure. Such joint configurations have a particular geometry that encourages the development of gullies in hard rock, e.g. through enhanced gravitational and hydrological erosional processes. In the catchment underlain by sedimentary rocks, penetrative joints that act as structural weaknesses seem to be exploited by gullies and rock couloirs. However, the lithological setting and bedding configuration prominently control the development of erosional landforms, and influence not only the local pattern of geomorphic features, but the general morphology of the catchment. The orientations of the maximum joint frequency are clearly associated with the gully network, suggesting that its development is governed by anisotropy in rock strength. These two catchments are typical of bedrock-dominated basins prone to intense processes of debris supply. This study suggests a quantitative approach for describing the relationship between bedrock jointing and geomorphic features geometry. Incorporation of bedrock structure can be relevant when studying processes governing the transfer of clastic material, for the assessment of sediment yields and in landforms evolution models.
Resumo:
BACKGROUND: To identify patients with spontaneous subarachnoid hemorrhage for whom CT angiography alone can exclude ruptured aneurysms. METHODS: An observational retrospective review was carried out of all consecutive patients with non-traumatic subarachnoid hemorrhage who underwent both CT angiography and catheter angiography to exclude an aneurysm. CT angiography negative cases (no aneurysm) were classified according to their CT hemorrhage pattern as "aneurismal", "perimesencephalic" or as "no-hemorrhage." RESULTS: Two hundred and forty-one patients were included. A CT angiography aneurysm detection sensitivity and specificity of 96.4% and 96.0% were observed. All 35 cases of perimesencephalic or no-hemorrhage out of 78 CT angiography negatives also had negative angiography findings. CONCLUSIONS: CT angiography is self-reliant to exclude ruptured aneurysms when either a perimesencephalic hemorrhage or no-hemorrhage pattern is identified on the CT within a week of symptom onset.
Resumo:
Context: Ovarian tumors (OT) typing is a competency expected from pathologists, with significant clinical implications. OT however come in numerous different types, some rather rare, with the consequence of few opportunities for practice in some departments. Aim: Our aim was to design a tool for pathologists to train in less common OT typing. Method and Results: Representative slides of 20 less common OT were scanned (Nano Zoomer Digital Hamamatsu®) and the diagnostic algorithm proposed by Young and Scully applied to each case (Young RH and Scully RE, Seminars in Diagnostic Pathology 2001, 18: 161-235) to include: recognition of morphological pattern(s); shortlisting of differential diagnosis; proposition of relevant immunohistochemical markers. The next steps of this project will be: evaluation of the tool in several post-graduate training centers in Europe and Québec; improvement of its design based on evaluation results; diffusion to a larger public. Discussion: In clinical medicine, solving many cases is recognized as of utmost importance for a novice to become an expert. This project relies on the virtual slides technology to provide pathologists with a learning tool aimed at increasing their skills in OT typing. After due evaluation, this model might be extended to other uncommon tumors.
Resumo:
Back-focal-plane interferometry is used to measure displacements of optically trapped samples with very high spatial and temporal resolution. However, the technique is closely related to a method that measures the rate of change in light momentum. It has long been known that displacements of the interference pattern at the back focal plane may be used to track the optical force directly, provided that a considerable fraction of the light is effectively monitored. Nonetheless, the practical application of this idea has been limited to counter-propagating, low-aperture beams where the accurate momentum measurements are possible. Here, we experimentally show that the connection can be extended to single-beam optical traps. In particular, we show that, in a gradient trap, the calibration product κ·β (where κ is the trap stiffness and 1/β is the position sensitivity) corresponds to the factor that converts detector signals into momentum changes; this factor is uniquely determined by three construction features of the detection instrument and does not depend, therefore, on the specific conditions of the experiment. Then, we find that force measurements obtained from back-focal-plane displacements are in practice not restricted to a linear relationship with position and hence they can be extended outside that regime. Finally, and more importantly, we show that these properties are still recognizable even when the system is not fully optimized for light collection. These results should enable a more general use of back-focal-plane interferometry whenever the ultimate goal is the measurement of the forces exerted by an optical trap.
Resumo:
Back-focal-plane interferometry is used to measure displacements of optically trapped samples with very high spatial and temporal resolution. However, the technique is closely related to a method that measures the rate of change in light momentum. It has long been known that displacements of the interference pattern at the back focal plane may be used to track the optical force directly, provided that a considerable fraction of the light is effectively monitored. Nonetheless, the practical application of this idea has been limited to counter-propagating, low-aperture beams where the accurate momentum measurements are possible. Here, we experimentally show that the connection can be extended to single-beam optical traps. In particular, we show that, in a gradient trap, the calibration product κ·β (where κ is the trap stiffness and 1/β is the position sensitivity) corresponds to the factor that converts detector signals into momentum changes; this factor is uniquely determined by three construction features of the detection instrument and does not depend, therefore, on the specific conditions of the experiment. Then, we find that force measurements obtained from back-focal-plane displacements are in practice not restricted to a linear relationship with position and hence they can be extended outside that regime. Finally, and more importantly, we show that these properties are still recognizable even when the system is not fully optimized for light collection. These results should enable a more general use of back-focal-plane interferometry whenever the ultimate goal is the measurement of the forces exerted by an optical trap.
Resumo:
In this communication we introduce a low or reduced coherence interferometry technique that can be used to retrieve surface topology on samples with high roughness. Moreover, we will show that the approach enables surface topology measurement also at the interface of so-called turbid media, where multiple scattering inside tissues can be a major issue, preventing accurate measurements.
Resumo:
A method for generating beams with arbitrary polarization and shape is proposed. Our design requires the use of a Mach-Zehnder set-up combined with translucent liquid crystal displays in each arm of the interferometer; in this way, independent manipulation of each transverse beam components is possible. The target of this communication is to develop a numerical procedure for calculating the holograms required for dynamically encode any amplitude value and polarization state in each point of the wavefront. Several examples demonstrating the capabilities of the method are provided.