989 resultados para Dental impression techniques
Resumo:
Foram avaliadas as técnicas radiográficas dentárias intra (TIB) e extrabucal (TEB) em 50 cães com doença periodontal, no intuito de padronizar os procedimentos de diagnóstico dessa síndrome. A TIB revelou que 16 animais não apresentaram lesões ósseas visíveis, enquanto a TEB apontou que 39 pacientes foram negativos para as mesmas lesões. em resumo, a TIB foi mais eficaz na detecção de sinais radiográficos, especialmente as chamadas lesões finas, que a TEB, sendo a técnica de escolha na síndrome periodontal.
Resumo:
Purpose: This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. Materials and Methods: A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. Results: The mean values (+/- standard deviations) for the abutment/framework interface gaps were: master cast, 32 +/- 2 mu m; tapered metal, 44 +/- 10 mu m; splinted metal, 69 +/- 28 mu m; tapered plastic, 164 +/- 58 mu m; splinted plastic, 128 +/- 47 mu m. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. Conclusions: In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:544-550.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
STATEMENT OF PROBLEM: Despite careful procedures, master stone dies may be damaged during laboratory procedures. The dentist routinely adjusts castings because the marginal fit of casting is not as accurate as on the dies. PURPOSE: This study evaluated the technique of internal adjustment of castings with use of duplicated stone dies and a disclosing agent to improve marginal fit discrepancy. MATERIAL AND METHODS: Thirty-two nickel-chromium copings were fabricated and simulated standard clinical and laboratory procedures with 2 variables: tooth preparation convergence angles of 6 and 18 degrees, with or without internal relief. Master stone dies and their duplicates were selected for coping construction and internal adjustment, respectively. A specimen positioning device was coupled with a Toolmakers microscope to allow reproducibility of measurements. Each coping was evaluated at 8 locations of its marginal perimeter, before and after internal adjustment. RESULTS: Marginal fit discrepancy of copings were significantly reduced with an internal adjustment technique (mean > 52%) for all experimental groups. Tooth preparations with greater convergence and internally relieved castings recorded a better marginal fit. CONCLUSION: The casting internal adjustment technique with use of duplicated stone dies and a disclosing agent substantially reduced marginal fit discrepancy.
Resumo:
Restorative dentistry has been increasingly concerned with preservation of the dental structure. For that reason, ultraconservative cavity preparations have been performed with air abrasion systems. The aim of this study was to present treatment options for the occlusal surface of first permanent molars with employment of the conventional method and the air abrasion system for accomplishment of the cavity preparation and a composite occlusal matrix for an accurate reproduction of the tooth surface.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The present study aims at evaluating dimensional alteration of stone casts made from impressions with a standard irreversible hydrocolloid and an antimicrobial one. For this, an alginate without disinfectant (Type II Jeltrate) and other containing chlorhexidine (Type II Avagel) were used, which rose by the same regime of treatment: without disinfection; immersion; and spraying. A 1% sodium hypochlorite solution was used for 10 minutes. To obtain the impressions, a perforated impression tray was made from a standard metal model. After molding, the molds were washed in running water for 30 seconds to simulate removal of saliva. Then, with the exception of the control group, these molds were subjected to disinfection treatment. After 10 minutes they were washed again. 60 samples poured with type V special gypsum (Durone) were obtained, that were measured 3 times in a stereomicroscope (SZX12, Olympus) to record the average of dimensional alterations. The disinfection treatment did not bring significant changes in the models obtained from both alginate tested (standard p = 0.7102; with chlorhexidine p = 0.5832). The results showed a statistically significant and additional advantage of the traditional alginate on alginate with chlorhexidine, with respect to dimensional alteration (p < 0.05).
Resumo:
The dental trade has offered dental impression and dental stone for orthodontic use ensuring accurate models. The compatibility between these materials is defined by the wetting of the model surfaces by the mixture water/stone poured over it and the influenced by the method of disinfection of model and disinfectant solution used. It was evaluated the influence of spray disinfection with sodium hypochlorite 1% on the wettability of two commercial alginate (Jeltrate ® - Dentsply and Orthoprint ® - Zhermack) at two commercial type III gypsum (Rio ® - ME and AOBussoli Orthogesso Orthogesso ®-SA). Twenty models were fabricated for each type of alginate, which were divided into two groups (water and sodium hypochlorite), receiving respectively water and sodium hypochlorite 1% spray. Each group of models was then further divided into two subgroups, and on their surface were poured 2 ml of type III gypsum (Gesso Rio® or Orthogesso®). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to ANOVA and founded statistical significance for solutions used. It was concluded that sodium hypochlorite spray improved wettability of alginates studied.
Resumo:
The cares at the manipulation of the alginate (condensation, disinfection of the impression and the time elapsed until the leak of the plaster) deserve special attention considering the great amount of distortions occurring every time the impression is not fill of plaster in a brief space of time and appropriate storage conditions. Besides its adaptation to the plaster suffers influence of the events happened after the impression is removed of the mouth. The purpose of this research was to evaluate the wetting capacity of three brands of alginate (Jeltrate™,Hydrogum™ e Orthoprint™) by the plaster type III (Rio™) under the influence of disinfection by sodium hypochlorite 1% sprays and the time of storage of 15 minutes,30 minutes, 1 hour, 6, 12 and 24 hours. There were made 60 impressions of each brand of alginate divided in two groups (water and sodium hypochlorite 1%) rearranged after the application of the sodium hypochlorite spray according to the storage time (15 or 30 minutes and 1,6,12, or 24 hours). On the surface of the impressions 2ml of plaster were flowed, proportioned and condensed in agreement with manufacturer‘s instructions. After the final setting expansion the casts were sectioned vertically and medially, regularized at the cut surface (emery paper 400) and setted for reading the contact angle at the microscope Carl Zeiss. The obtained results, submitted to statistical treatment (ANOVA) revealed significant differences when compared the employed solutions (water and sodium hypochlorite 1%) and the time of storage. The sodium hypochlorite 1% exhibited the smallest contact angles and the times of storage of 15 minutes and 6 hours the smallest and larger angles, respectively. It can be concluded that the alginate impressions exhibited larger adaptation to the plaster when disinfected by hypochlorite of sodium 1% and stocked by 15 minutes.
Resumo:
The functional impression technique is one of the most important steps for complete and/or partial edentulism treatment. So, correct analysis and record of supporting structures are essential to determine the denture extension. The functional impression technique has two stages - a customized final impression tray and a border impression - which aims to record the optimal denture supporting area. The aim of this study was to review the literature related to border impression and functional impression techniques, describing the technique and materials, and identifying the procedure’s objectives and function.
Resumo:
The aim of the present study was to evaluate the tensile strength, elongation, microhardness, microstructure and fracture pattern of various metal ceramic alloys cast under different casting conditions. Two Ni-Cr alloys, Co-Cr and Pd-Ag were used. The casting conditions were as follows: electromagnetic induction under argon atmosphere, vacuum, using blowtorch without atmosphere control. For each condition, 16 specimens, each measuring 25 mm long and 2.5 mm in diameter, were obtained. Ultimate tensile strength (UTS) and elongation (EL) tests were performed using a Kratos machine. Vickers Microhardness (VM), fracture mode and microstructure were analyzed by SEM. UTS, EL and VM data were statistically analyzed using ANOVA. For UTS, alloy composition had a direct influence on casting condition of alloys (Wiron 99 and Remanium CD), with higher values shown when cast with Flame/Air (p < 0.05). The factors "alloy" and "casting condition" influenced the EL and VM results, generally presenting opposite results, i.e., alloy with high elongation value had lower hardness (Wiron 99), and casting condition with the lowest EL values had the highest VM values (blowtorch). Both factors had significant influence on the properties evaluated, and prosthetic laboratories should select the appropriate casting method for each alloy composition to obtain the desired property.