Comparison of the Accuracy of Plastic and Metal Stock Trays for Implant Impressions


Autoria(s): Del'Acqua, Marcelo Antonialli; de Avila, Erica Dorigatti; Chagas Amaral, Angela Libia; Pereira Pinelli, Ligia Antunes; Mollo Junior, Francisco de Assis
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/05/2012

Resumo

Purpose: This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. Materials and Methods: A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. Results: The mean values (+/- standard deviations) for the abutment/framework interface gaps were: master cast, 32 +/- 2 mu m; tapered metal, 44 +/- 10 mu m; splinted metal, 69 +/- 28 mu m; tapered plastic, 164 +/- 58 mu m; splinted plastic, 128 +/- 47 mu m. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. Conclusions: In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:544-550.

Formato

544-550

Identificador

http://www.quintpub.com/journals/omi/abstract.php?article_id=12162#.Ui9kKsbks_Y

International Journal of Oral & Maxillofacial Implants. Hanover Park: Quintessence Publishing Co Inc, v. 27, n. 3, p. 544-550, 2012.

0882-2786

http://hdl.handle.net/11449/16526

WOS:000305203300007

Idioma(s)

eng

Publicador

Quintessence Publishing Co Inc

Relação

International Journal of Oral & Maxillofacial Implants

Direitos

closedAccess

Palavras-Chave #closed tray #implant impression accuracy #open tray #splinted squared impression coping #stock tray #tapered impression coping
Tipo

info:eu-repo/semantics/article