933 resultados para Current-voltage analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work looks at the effect on mid-gap interface state defect density estimates for In0.53Ga0.47As semiconductor capacitors when different AC voltage amplitudes are selected for a fixed voltage bias step size (100 mV) during room temperature only electrical characterization. Results are presented for Au/Ni/Al2O3/In0.53Ga0.47As/InP metal–oxide–semiconductor capacitors with (1) n-type and p-type semiconductors, (2) different Al2O3 thicknesses, (3) different In0.53Ga0.47As surface passivation concentrations of ammonium sulphide, and (4) different transfer times to the atomic layer deposition chamber after passivation treatment on the semiconductor surface—thereby demonstrating a cross-section of device characteristics. The authors set out to determine the importance of the AC voltage amplitude selection on the interface state defect density extractions and whether this selection has a combined effect with the oxide capacitance. These capacitors are prototypical of the type of gate oxide material stacks that could form equivalent metal–oxide–semiconductor field-effect transistors beyond the 32 nm technology node. The authors do not attempt to achieve the best scaled equivalent oxide thickness in this work, as our focus is on accurately extracting device properties that will allow the investigation and reduction of interface state defect densities at the high-k/III–V semiconductor interface. The operating voltage for future devices will be reduced, potentially leading to an associated reduction in the AC voltage amplitude, which will force a decrease in the signal-to-noise ratio of electrical responses and could therefore result in less accurate impedance measurements. A concern thus arises regarding the accuracy of the electrical property extractions using such impedance measurements for future devices, particularly in relation to the mid-gap interface state defect density estimated from the conductance method and from the combined high–low frequency capacitance–voltage method. The authors apply a fixed voltage step of 100 mV for all voltage sweep measurements at each AC frequency. Each of these measurements is repeated 15 times for the equidistant AC voltage amplitudes between 10 mV and 150 mV. This provides the desired AC voltage amplitude to step size ratios from 1:10 to 3:2. Our results indicate that, although the selection of the oxide capacitance is important both to the success and accuracy of the extraction method, the mid-gap interface state defect density extractions are not overly sensitive to the AC voltage amplitude employed regardless of what oxide capacitance is used in the extractions, particularly in the range from 50% below the voltage sweep step size to 50% above it. Therefore, the use of larger AC voltage amplitudes in this range to achieve a better signal-to-noise ratio during impedance measurements for future low operating voltage devices will not distort the extracted interface state defect density.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Membrane currents were recorded under voltage clamp from root hairs of Arabidopsis thaliana L. using the two-electrode method. Concurrent measurements of membrane voltage distal to the point of current injection were also carried out to assess the extent of current dissipation along the root hair axis. Estimates of the characteristic cable length, λ, showed this parameter to be a function both of membrane voltage and of substrate concentration for transport. The mean value for λ at 0 mV was 103 ± 20 μm (n=17), but ranged by as much as 6-fold in any one cell for membrane voltages from -300 to +40 mV and was affected by 0.25 to 3-fold at any one voltage on raising [K+]0 from 0.1 to 10 mol m-3. Current dissipation along the length of the cells lead to serious distortions of the current-voltage [I-V) characteristic, including consistent underestimates of membrane current as well as a general linearization of the I-V curve and a masking of conductance changes in the presence of transported substrates. In some experiments, microelectrodes were also placed in neighbouring epidermal cells to record the extent of intercellular coupling. Even with current-passing microelectrodes placed at the base of root hairs, coupling was ≤5% (voltage deflection of the epidermal cell ≤5% that recorded at the site of current injection), indicating an appreciable resistance to current passage between cells. These results demonstrate the feasibility of using root hairs as a 'single-cell model' in electrophysiological analyses of transport across the higher-plant plasma membrane; they also confirmed the need to correct for the cable properties of these cells on a cell-by-cell basis. © 1994 Oxford University Press.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We observed the decrease of the hysteresis effect and the transition from the stable to the dynamic domain regime in doped superlattices with increasing temperature. The current-voltage characteristics and the behaviours of the domain boundary are dominated by the temperature-dependent lineshape of the electric field dependence of the drift velocity (V(F)), As the peak-valley ratio in the V(F) curve decreases with increasing temperature, the hysteresis will diminish and temporal current self-oscillations will occur. The simulated calculation, which takes the difference in V(F) curves into consideration, gives a good agreement with the experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dynamic dc voltage band was found emerging from each sawtooth-like branch of the current-voltage characteristics of a doped GaAs/AlAs superlattice in the transition process from static to dynamic electric-field domain formation caused by increasing the sample temperature. As the temperature increases, these dynamic dc voltage bands expand within each sawtooth-like branch, squeeze out the static regions, and join up together to turn the whole plateau into dynamic electric-field domain formation. These results are well explained by a general analysis of stability of the sequential tunneling current in superlattices. (C) 1999 American Institute of Physics. [S0003-6951(99)04443-5].

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The output characteristics of micro-solar cell arrays are analyzed on the basis of a modified model in which the shunt resistance between cell lines results in current leakage. The modification mainly consists of adding a shunt resistor network to the traditional model. The obtained results agree well with the reported experimental results. The calculation results demonstrate that leakage current in substrate affects seriously the performance of GaAs micro- solar cell arrays. The performance of arrays can be improved by reducing the number of cells per line. In addition, at a certain level of integration, an appropriate space occupancy rate of the single cell is recommended for ensuring high open circuit voltages, and it is more appropriate to set the rates at 80%-90% through the calculation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Active-clamp dc-dc converters are pulsewidth-modulated converters having two switches featuring zero-voltage switching at frequencies beyond 100 kHz. Generalized equivalent circuits valid for steady-state and dynamic performance have been proposed for the family of active-clamp converters. The active-clamp converter is analyzed for its dynamic behavior under current control in this paper. The steady-state stability analysis is presented. On account of the lossless damping inherent in the active-clamp converters, it appears that the stability region in the current-controlled active-clamp converters get extended for duty ratios, a little greater than 0.5, unlike in conventional hard-switched converters. The conventional graphical approach fails to assess the stability of current-controlled active-clamp converters due to the coupling between the filter inductor current and resonant inductor current. An analysis that takes into account the presence of the resonant elements is presented to establish the condition for stability. This method correctly predicts the stability of the current-controlled active-clamp converters. A simple expression for the maximum duty cycle for subharmonic free operation is obtained. The results are verified experimentally.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Active-clamp dc-dc converters are pulsewidth-modulated converters having two switches featuring zero-voltage switching at frequencies beyond 100 kHz. Generalized equivalent circuits valid for steady-state and dynamic performance have been proposed for the family of active-clamp converters. The active-clamp converter is analyzed for its dynamic behavior under current control in this paper. The steady-state stability analysis is presented. On account of the lossless damping inherent in the active-clamp converters, it appears that the stability region in the current-controlled active-clamp converters get extended for duty ratios, a little greater than 0.5 unlike in conventional hard-switched converters. The conventional graphical approach fails to assess the stability of current-controlled active-clamp converters, due to the coupling between the filter inductor current and resonant inductor current. An analysis that takes into account the presence of the resonant elements is presented to establish the condition for stability. This method correctly predicts the stability of the current-controlled active-clamp converters. A simple expression for the maximum duty cycle for subharmonic-free operation is obtained. The results are verified experimentally.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Problem of DC link size in a stiff voltage-source inverter for electric drive is described in the paper. Advantages of advanced film capacitor technology over conventional one for DC link application are reviewed. Conventional DC link capacitor selection methods are questioned in view of advanced capacitor technology utilization in stiff voltage-source inverter. For capacitor selection maximum ripple rms current point is shown. DC link ripple current spectrum analysis under modern PWM techniques is presented. Some capacitor selection recommendations are given. The analysis has been aided greatly by computer modeling in PSpice. ©2005 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electron transport in a self-consistent potential along a ballistic two-terminal conductor has been investigated. We have derived general formulas which describe the nonlinear current-voltage characteristics, differential conductance, and low-frequency current and voltage noise assuming an arbitrary distribution function and correlation properties of injected electrons. The analytical results have been obtained for a wide range of biases: from equilibrium to high values beyond the linear-response regime. The particular case of a three-dimensional Fermi-Dirac injection has been analyzed. We show that the Coulomb correlations are manifested in the negative excess voltage noise, i.e., the voltage fluctuations under high-field transport conditions can be less than in equilibrium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alle bisher untersuchten Lebewesen besitzen (circadiane) innere Uhren, die eine endogene Perioden-länge von ungefähr 24 Stunden generieren. Eine innere Uhr kann über Zeitgeber mit der Umwelt synchronisiert werden und ermöglicht dem Organismus, rhythmische Umweltveränderungen vorweg zu nehmen. Neben einem zentralen Schrittmacher, der Physiologie und Verhalten des Organismus steuert, gibt es in unterschiedlichen Organen auch periphere Uhren, die die zeitlichen Abläufe in der spezifischen Funktion dieser Organe steuern. In dieser Arbeit sollten zentrale und periphere Schrittmacherneurone von Insekten physiologisch untersucht und verglichen werden. Die Neurone der akzessorischen Medulla (AME) von Rhyparobia maderae dienten als Modellsystem für zentrale Schrittmacher, während olfaktorische Rezeptorneurone (ORNs) von Manduca sexta als Modellsystem für periphere Schrittmacher dienten. Die zentralen Schrittmacherneurone wurden in extrazellulären Ableitungen an der isolierten AME (Netzwerkebene) und in Patch-Clamp Experimenten an primären AME Zellkulturen (Einzelzellebene) untersucht. Auf Netzwerkebene zeigten sich zwei charakteristische Aktivitätsmuster: regelmäßige Aktivität und Wechsel zwischen hoher und niedriger Aktivität (Oszillationen). Es wurde gezeigt, dass Glutamat ein Neurotransmitter der weitverbreiteten inhibitorischen Synapsen der AME ist, und dass in geringem Maße auch exzitatorische Synapsen vorkommen. Das Neuropeptid pigment-dispersing factor (PDF), das von nur wenigen AME Neuronen exprimiert wird und ein wichtiger Kopplungsfaktor im circadianen System ist, führte zu Hemmungen, Aktivierungen oder Oszillationen. Die Effekte waren transient oder langanhaltend und wurden wahrscheinlich durch den sekundären Botenstoff cAMP vermittelt. Ein Zielmolekül von cAMP war vermutlich exchange protein directly activated by cAMP (EPAC). Auf Einzelzellebene wurde gezeigt, dass die meisten AME Neurone depolarisiert waren und deshalb nicht feuerten. Die Analyse von Strom-Spannungs-Kennlinien und pharmakologische Experimente ergaben, dass unterschiedliche Ionenkanäle vorhanden waren (Ca2+, Cl-, K+, Na+ Kanäle sowie nicht-spezifische Kationenkanäle). Starke, bei hohen Spannungen aktivierende Ca2+ Ströme (ICa) könnten eine wichtige Rolle bei Ca2+-abhängiger Neurotransmitter-Ausschüttung, Oszillationen, und Aktionspotentialen spielen. PDF hemmte unterschiedliche Ströme (ICa, IK und INa) und aktivierte nicht-spezifische Kationenströme (Ih). Es wurde angenommen, dass simultane PDF-abhängige Hyper- und Depolarisationen rhythmische Membranpotential-Oszillationen verursachen. Dieser Mechanismus könnte eine Rolle bei PDF-abhängigen Synchronisationen spielen. Die Analyse peripherer Schrittmacherneurone konzentrierte sich auf die Charakterisierung des olfaktorischen Corezeptors von M. sexta (MsexORCO). In anderen Insekten ist ORCO für die Membran-Insertion von olfaktorischen Rezeptoren (ORs) erforderlich. ORCO bildet Komplexe mit den ORs, die in heterologen Expressionssystemen als Ionenkanäle fungieren und Duft-Antworten vermitteln. Es wurde die Hypothese aufgestellt, dass MsexORCO in pheromonsensitiven ORNs in vivo nicht als Teil eines ionotropen Rezeptors sondern als Schrittmacherkanal fungiert, der unterschwellige Membranpotential-Oszillationen generiert. MsexORCO wurde mit vermeintlichen Pheromonrezeptoren in human embryonic kidney (HEK 293) Zellen coexprimiert. Immuncytochemie und Ca2+ Imaging Experimente zeigten sehr schwache Expressionsraten. Trotzdem war es möglich zu zeigen, dass MsexORCO wahrscheinlich ein spontan-aktiver, Ca2+-permeabler Ionenkanal ist, der durch den ORCO-Agonisten VUAA1 und cyclische Nucleotide aktiviert wird. Außerdem wiesen die Experimente darauf hin, dass MsexOR-1 offensichtlich der Bombykal-Rezeptor ist. Eine weitere Charakterisierung von MsexORCO in primären M. sexta ORN Zellkulturen konnte nicht vollendet werden, weil die ORNs nicht signifikant auf ORCO-Agonisten oder -Antagonisten reagierten.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Crowbar switches are largely used in plasma devices, such as field-reversed configuration (FRC) machines and tokamaks, to avoid energy return from the discharge coil to the capacitor bank. A method of identification of all resistances, inductances and currents involved in capacitor bank discharges using a crowbar is proposed based on the derivation of the general analytical form of the coil current. This analysis can also be used for optimization of the discharge, reducing the ripple amplitude inherent in the crowbar-switched current. Fitting results of the TC-1 UNICAMP FRC device are also presented in this work.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a new high power factor three-phase rectifier based on a Y-connected differential autotransformer with reduced kVA and 18-pulse input current followed by three DC-DC boost converters. The topology provides a regulated output voltage and natural three-phase input power factor correction. The lowest input current harmonic components are the 17th and the 19th. Three boost converters, with constant input currents and regulated parallel connected output voltages are used to process 4kW each one. Analytical results from Fourier analyses of winding currents and the vector diagram of winding voltages are presented. Simulation results to verify the proposed concept and experimental results are shown in the paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the analysis, design, simulation, and experimental results for a high frequency high Power-Factor (PF) AC (Alternate Current) voltage regulator, using a Sepic converter as power stage. The control technique employed to impose a sinusoidal input current waveform, with low Total Harmonic Distortion (THD), is the sinusoidal variable hysteresis control. The control technique was implemented in a FPGA (Field Programmable Gate Array) device, using a Hardware Description Language (VHDL). Through the use of the proposed control technique, the AC voltage regulator performs active power-factor correction, and low THD in the input current, for linear and non-linear loads, satisfying the requirements of the EEC61000-3-2 standards. Experimental results from an example prototype, designed for 300W of nominal output power, 50kHz (switching frequency), and 127Vrms of nominal input and output voltages, are presented in order to validate the proposed AC regulator. © 2005 IEEE.