ANALYTIC STUDY ON HIGH-VOLTAGE CROWBAR SYSTEM


Autoria(s): Campos, D. O.; Machida, M.; Honda, R. Y.; Aramaki, E. A.; Berni, L. A.
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/10/1995

Resumo

Crowbar switches are largely used in plasma devices, such as field-reversed configuration (FRC) machines and tokamaks, to avoid energy return from the discharge coil to the capacitor bank. A method of identification of all resistances, inductances and currents involved in capacitor bank discharges using a crowbar is proposed based on the derivation of the general analytical form of the coil current. This analysis can also be used for optimization of the discharge, reducing the ripple amplitude inherent in the crowbar-switched current. Fitting results of the TC-1 UNICAMP FRC device are also presented in this work.

Formato

5818-5820

Identificador

http://dx.doi.org/10.1143/JJAP.34.5818

Japanese Journal of Applied Physics Part 1-regular Papers Short Notes & Review Papers. Minato-ku Tokyo: Japan J Applied Physics, v. 34, n. 10, p. 5818-5820, 1995.

0021-4922

http://hdl.handle.net/11449/32935

10.1143/JJAP.34.5818

WOS:A1995TF79500063

Idioma(s)

eng

Publicador

Japan J Applied Physics

Relação

Japanese Journal of Applied Physics Part 1-regular Papers Short Notes & Review Papers

Direitos

closedAccess

Palavras-Chave #CROWBAR SWITCHES #CROWBAR CURRENT #CIRCUIT ANALYSIS #HIGH-VOLTAGE AND HIGH-CURRENT #THETA-PINCH
Tipo