963 resultados para Conventional evaluation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Notwithstanding significant efforts by international aid agencies, aid ineffectiveness became apparent in 1990s as the impact of continued development intervention did not endure the expected outcomes. Conventional monitoring and evaluation by those agencies is critiqued for focusing on measuring project outcomes and giving little attention to aspects of sustainability. As a result, devising a rigorous evaluation framework for educational development has been sought in light of recent paradigm shifts in international development. This paper reports on a case study of an Egyptian educational development project highlighting the importance of transforming the evaluation procedures to process evaluation so as to enhance project impact and longevity. This requires building evaluation capacity of the aid recipient country.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Proposed transmission smart grids will use a digital platform for the automation of substations operating at voltage levels of 110 kV and above. The IEC 61850 series of standards, released in parts over the last ten years, provide a specification for substation communications networks and systems. These standards, along with IEEE Std 1588-2008 Precision Time Protocol version 2 (PTPv2) for precision timing, are recommended by the both IEC Smart Grid Strategy Group and the NIST Framework and Roadmap for Smart Grid Interoperability Standards for substation automation. IEC 61850-8-1 and IEC 61850-9-2 provide an inter-operable solution to support multi-vendor digital process bus solutions, allowing for the removal of potentially lethal voltages and damaging currents from substation control rooms, a reduction in the amount of cabling required in substations, and facilitates the adoption of non-conventional instrument transformers (NCITs). IEC 61850, PTPv2 and Ethernet are three complementary protocol families that together define the future of sampled value digital process connections for smart substation automation. This paper describes a specific test and evaluation system that uses real time simulation, protection relays, PTPv2 time clocks and artificial network impairment that is being used to investigate technical impediments to the adoption of SV process bus systems by transmission utilities. Knowing the limits of a digital process bus, especially when sampled values and NCITs are included, will enable utilities to make informed decisions regarding the adoption of this technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In 1990 the Dispute Resolution Centres Act, 1990 (Qld) (the Act) was passed by the Queensland Parliament. In the second reading speech for the Dispute Resolution Centres Bill on May 1990 the Hon Dean Wells stated that the proposed legislation would make mediation services available “in a non-coercive, voluntary forum where, with the help of trained mediators, the disputants will be assisted towards their own solutions to their disputes, thereby ensuring that the result is acceptable to the parties” (Hansard, 1990, 1718). It was recognised at that time that a method for resolving disputes was necessary for which “the conventional court system is not always equipped to provide lasting resolution” (Hansard, 1990, 1717). In particular, the lasting resolution of “disputes between people in continuing relationships” was seen as made possible through the new legislation; for example, “domestic disputes, disputes between employees, and neighbourhood disputes relating to such issues as overhanging tree branches, dividing fences, barking dogs, smoke, noise and other nuisances are occurring continually in the community” (Hansard, 1990, 1717). The key features of the proposed form of mediation in the Act were articulated as follows: “attendance of both parties at mediation sessions is voluntary; a party may withdraw at any time; mediation sessions will be conducted with as little formality and technicality as possible; the rules of evidence will not apply; any agreement reached is not enforceable in any court; although it could be made so if the parties chose to proceed that way; and the provisions of the Act do not affect any rights or remedies that a party to a dispute has apart from the Act” (Hansard, 1990, 1718). Since the introduction of the Act, the Alternative Dispute Resolution Branch of the Queensland Department of Justice and Attorney General has offered mediation services through, first the Community Justice Program (CJP), and then the Dispute Resolution Centres (DRCs) for a range of family, neighbourhood, workplace and community disputes. These services have mirrored those available through similar government agencies in other states such as the Community Justice Centres of NSW and the Victorian Dispute Resolution Centres. Since 1990, mediation has become one of the fastest growing forms of alternative dispute resolution (ADR). Sourdin has commented that "In addition to the growth in court-based and community-based dispute resolution schemes, ADR has been institutionalised and has grown within Australia and overseas” (2005, 14). In Australia, in particular, the development of ADR service provision “has been assisted by the creation and growth of professional organisations such as the Leading Edge Alternative Dispute Resolvers (LEADR), the Australian Commercial Dispute Centres (ACDC), Australian Disputes Resolution Association (ADRA), Conflict Resolution Network, and the Institute of Arbitrators and Mediators Australia (IAMA)” (Sourdin, 2005, 14). The increased emphasis on the use of ADR within education contexts (particularly secondary and tertiary contexts) has “also led to an increasing acceptance and understanding of (ADR) processes” (Sourdin, 2005, 14). Proponents of the mediation process, in particular, argue that much of its success derives from the inherent flexibility and creativity of the agreements reached through the mediation process and that it is a relatively low cost option in many cases (Menkel-Meadow, 1997, 417). It is also accepted that one of the main reasons for the success of mediation can be attributed to the high level of participation by the parties involved and thus creating a sense of ownership of, and commitment to, the terms of the agreement (Boulle, 2005, 65). These characteristics are associated with some of the core values of mediation, particularly as practised in community-based models as found at the DRCs. These core values include voluntary participation, party self-determination and party empowerment (Boulle, 2005, 65). For this reason mediation is argued as being an effective approach to resolving disputes, that creates a lasting resolution of the issues. Evaluation of the mediation process, particularly in the context of the growth of ADR, has been an important aspect of the development of the process (Sourdin, 2008). Writing in 2005 for example, Boulle, states that “although there is a constant refrain for more research into mediation practice, there has been a not insignificant amount of mediation measurement, both in Australia and overseas” (Boulle, 2005, 575). The positive claims of mediation have been supported to a significant degree by evaluations of the efficiency and effectiveness of the process. A common indicator of the effectiveness of mediation is the settlement rate achieved. High settlement rates for mediated disputes have been found for Australia (Altobelli, 2003) and internationally (Alexander, 2003). Boulle notes that mediation agreement rates claimed by service providers range from 55% to 92% (Boulle, 2005, 590). The annual reports for the Alternative Dispute Resolution Branch of the Queensland Department of Justice and Attorney-General considered prior to the commencement of this study indicated generally achievement of an approximate settlement figure of 86% by the Queensland Dispute Resolution Centres. More recently, the 2008-2009 annual report states that of the 2291 civil dispute mediated in 2007-2008, 86% reached an agreement. Further, of the 2693 civil disputes mediated in 2008-2009, 73% reached an agreement. These results are noted in the report as indicating “the effectiveness of mediation in resolving disputes” and as reflecting “the high level of agreement achieved for voluntary mediations” (Annual Report, 2008-2009, online). Whilst the settlement rates for the DRCs are strong, parties are rarely contacted for long term follow-up to assess whether agreements reached during mediation lasted to the satisfaction of each party. It has certainly been the case that the Dispute Resolution Centres of Queensland have not been resourced to conduct long-term follow-up assessments of mediation agreements. As Wade notes, "it is very difficult to compare "success" rates” and whilst “politicians want the comparison studies (they) usually do not want the delay and expense of accurate studies" (1998, 114). To date, therefore, it is fair to say that the efficiency of the mediation process has been evaluated but not necessarily its effectiveness. Rather, the practice at the Queensland DRCs has been to evaluate the quality of mediation service provision and of the practice of the mediation process. This has occurred, for example, through follow-up surveys of parties' satisfaction rates with the mediation service. In most other respects it is fair to say that the Centres have relied on the high settlement rates of the mediation process as a sign of the effectiveness of mediation (Annual Reports 1991 - 2010). Research of the mediation literature conducted for the purpose of this thesis has also indicated that there is little evaluative literature that provides an in-depth analysis and assessment of the longevity of mediated agreements. Instead evaluative studies of mediation tend to assess how mediation is conducted, or compare mediation with other conflict resolution options, or assess the agreement rate of mediations, including parties' levels of satisfaction with the service provision of the dispute resolution service provider (Boulle, 2005, Chapter 16).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Monte Carlo DICOM Tool-Kit (MCDTK) is a software suite designed for treatment plan dose verification, using the BEAMnrc and DOSXYZnrc Monte Carlo codes. MCDTK converts DICOM-format treatment plan information into Monte Carlo input files and compares the results of Monte Carlo treatment simulations with conventional treatment planning dose calculations. In this study, a treatment is planned using a commercial treatment planning system, delivered to a pelvis phantom containing ten thermoluminescent dosimeters and simulated using BEAMnrc and DOSXYZnrc using inputs derived from MCDTK. The dosimetric accuracy of the Monte Carlo data is then evaluated via comparisons with the dose distribution obtained from the treatment planning system as well as the in-phantom point dose measurements. The simulated beam arrangement produced by MCDTK is found to be in geometric agreement with the planned treatment. An isodose display generated from the Monte Carlo data by MCDTK shows general agreement with the isodose display obtained from the treatment planning system, except for small regions around density heterogeneities in the phantom, where the pencil-beam dose calculation performed by the treatment planning systemis likely to be less accurate. All point dose measurements agree with the Monte Carlo data obtained using MCDTK, within confidence limits, and all except one of these point dose measurements show closer agreement with theMonte Carlo data than with the doses calculated by the treatment planning system. This study provides a simple demonstration of the geometric and dosimetric accuracy ofMonte Carlo simulations based on information from MCDTK.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background The onsite treatment of sewage and effluent disposal within the premises is widely prevalent in rural and urban fringe areas due to the general unavailability of reticulated wastewater collection systems. Despite the seemingly low technology of the systems, failure is common and in many cases leading to adverse public health and environmental consequences. Therefore it is important that careful consideration is given to the design and location of onsite sewage treatment systems. It requires an understanding of the factors that influence treatment performance. The use of subsurface effluent absorption systems is the most common form of effluent disposal for onsite sewage treatment and particularly for septic tanks. Additionally in the case of septic tanks, a subsurface disposal system is generally an integral component of the sewage treatment process. Therefore location specific factors will play a key role in this context. The project The primary aims of the research project are: • to relate treatment performance of onsite sewage treatment systems to soil conditions at site; • to identify important areas where there is currently a lack of relevant research knowledge and is in need of further investigation. These tasks were undertaken with the objective of facilitating the development of performance based planning and management strategies for onsite sewage treatment. The primary focus of the research project has been on septic tanks. Therefore by implication the investigation has been confined to subsurface soil absorption systems. The design and treatment processes taking place within the septic tank chamber itself did not form a part of the investigation. In the evaluation to be undertaken, the treatment performance of soil absorption systems will be related to the physico-chemical characteristics of the soil. Five broad categories of soil types have been considered for this purpose. The number of systems investigated was based on the proportionate area of urban development within the Brisbane region located on each soil types. In the initial phase of the investigation, though the majority of the systems evaluated were septic tanks, a small number of aerobic wastewater treatment systems (AWTS) were also included. This was primarily to compare the effluent quality of systems employing different generic treatment processes. It is important to note that the number of different types of systems investigated was relatively small. As such this does not permit a statistical analysis to be undertaken of the results obtained. This is an important issue considering the large number of parameters that can influence treatment performance and their wide variability. The report This report is the second in a series of three reports focussing on the performance evaluation of onsite treatment of sewage. The research project was initiated at the request of the Brisbane City Council. The work undertaken included site investigation and testing of sewage effluent and soil samples taken at distances of 1 and 3 m from the effluent disposal area. The project component discussed in the current report formed the basis for the more detailed investigation undertaken subsequently. The outcomes from the initial studies have been discussed, which enabled the identification of factors to be investigated further. Primarily, this report contains the results of the field monitoring program, the initial analysis undertaken and preliminary conclusions. Field study and outcomes Initially commencing with a list of 252 locations in 17 different suburbs, a total of 22 sites in 21 different locations were monitored. These sites were selected based on predetermined criteria. To obtain house owner agreement to participate in the monitoring study was not an easy task. Six of these sites had to be abandoned subsequently due to various reasons. The remaining sites included eight septic systems with subsurface effluent disposal and treating blackwater or combined black and greywater, two sites treating greywater only and six sites with AWTS. In addition to collecting effluent and soil samples from each site, a detailed field investigation including a series of house owner interviews were also undertaken. Significant observations were made during the field investigations. In addition to site specific observations, the general observations include the following: • Most house owners are unaware of the need for regular maintenance. Sludge removal has not been undertaken in any of the septic tanks monitored. Even in the case of aerated wastewater treatment systems, the regular inspections by the supplier is confined only to the treatment system and does not include the effluent disposal system. This is not a satisfactory situation as the investigations revealed. • In the case of separate greywater systems, only one site had a suitably functioning disposal arrangement. The general practice is to employ a garden hose to siphon the greywater for use in surface irrigation of the garden. • In most sites, the soil profile showed significant lateral percolation of effluent. As such, the flow of effluent to surface water bodies is a distinct possibility. • The need to investigate the subsurface condition to a depth greater than what is required for the standard percolation test was clearly evident. On occasion, seemingly permeable soil was found to have an underlying impermeable soil layer or vice versa. The important outcomes from the testing program include the following: • Though effluent treatment is influenced by the physico-chemical characteristics of the soil, it was not possible to distinguish between the treatment performance of different soil types. This leads to the hypothesis that effluent renovation is significantly influenced by the combination of various physico-chemical parameters rather than single parameters. This would make the processes involved strongly site specific. • Generally the improvement in effluent quality appears to take place only within the initial 1 m of travel and without any appreciable improvement thereafter. This relates only to the degree of improvement obtained and does not imply that this quality is satisfactory. This calls into question the value of adopting setback distances from sensitive water bodies. • Use of AWTS for sewage treatment may provide effluent of higher quality suitable for surface disposal. However on the whole, after a 1-3 m of travel through the subsurface, it was not possible to distinguish any significant differences in quality between those originating from septic tanks and AWTS. • In comparison with effluent quality from a conventional wastewater treatment plant, most systems were found to perform satisfactorily with regards to Total Nitrogen. The success rate was much lower in the case of faecal coliforms. However it is important to note that five of the systems exhibited problems with regards to effluent disposal, resulting in surface flow. This could lead to possible contamination of surface water courses. • The ratio of TDS to EC is about 0.42 whilst the optimum recommended value for use of treated effluent for irrigation should be about 0.64. This would mean a higher salt content in the effluent than what is advisable for use in irrigation. A consequence of this would be the accumulation of salts to a concentration harmful to crops or the landscape unless adequate leaching is present. These relatively high EC values are present even in the case of AWTS where surface irrigation of effluent is being undertaken. However it is important to note that this is not an artefact of the treatment process but rather an indication of the quality of the wastewater generated in the household. This clearly indicates the need for further research to evaluate the suitability of various soil types for the surface irrigation of effluent where the TDS/EC ratio is less than 0.64. • Effluent percolating through the subsurface absorption field may travel in the form of dilute pulses. As such the effluent will move through the soil profile forming fronts of elevated parameter levels. • The downward flow of effluent and leaching of the soil profile is evident in the case of podsolic, lithosol and kransozem soils. Lateral flow of effluent is evident in the case of prairie soils. Gleyed podsolic soils indicate poor drainage and ponding of effluent. In the current phase of the research project, a number of chemical indicators such as EC, pH and chloride concentration were employed as indicators to investigate the extent of effluent flow and to understand how soil renovates effluent. The soil profile, especially texture, structure and moisture regime was examined more in an engineering sense to determine the effect of movement of water into and through the soil. However it is not only the physical characteristics, but the chemical characteristics of the soil also play a key role in the effluent renovation process. Therefore in order to understand the complex processes taking place in a subsurface effluent disposal area, it is important that the identified influential parameters are evaluated using soil chemical concepts. Consequently the primary focus of the next phase of the research project will be to identify linkages between various important parameters. The research thus envisaged will help to develop robust criteria for evaluating the performance of subsurface disposal systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across 5 centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity-modulated radiotherapy (IMRT) and 47 treated with volumetric-modulated arc therapy (VMAT). Methods Treatment plan quality was evaluated in terms of target dose homogeneity and organ-at-risk sparing, through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each organ-at-risk. Statistical significance was evaluated using two-tailed Welch’s T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. Results The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the organs-at-risk: with increased compliance with recommended organ-at-risk dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. Conclusions This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The introduction of online delivery platforms such as learning management systems (LMS) in tertiary education has changed the methods and modes of curriculum delivery and communication. While course evaluation methods have also changed from paper-based in-class-administered methods to largely online-administered methods, the data collection instruments have remained unchanged. This paper reports on a small exploratory study of two tertiary-level courses. The study investigated why design of the instruments and methods to administer surveys in the courses are ineffective measures against the intrinsic characteristics of online learning. It reviewed the students' response rates of the conventional evaluations for the courses over an eight-year period. It then compared a newly developed online evaluation and the conventional methods over a two-year period. The results showed the response rates with the new evaluation method increased by more than 80% from the average of the conventional evaluations (below 30%), and the students' written feedback was more detailed and comprehensive than in the conventional evaluations. The study demonstrated the possibility that the LMS-based learning evaluation can be effective and efficient in terms of the quality of students' participation and engagement in their learning, and for an integrated pedagogical approach in an online learning environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: It is important for nutrition intervention in malnourished patients to be guided by accurate evaluation and detection of small changes in the patient’s nutrition status over time. However, the current Subjective Global Assessment (SGA) is not able to detect changes in a short period of time. The aim of the study was to determine whether 7-point SGA is more time sensitive to nutrition changes than the conventional SGA. Methods: In this prospective study, 67 adult inpatients assessed as malnourished using both the 7-point SGA and conventional SGA were recruited. Each patient received nutrition intervention and was followed up post-discharge. Patients were reassessed using both tools at 1, 3 and 5 months from baseline assessment. Results: It took significantly shorter time to see a one-point change using 7-point SGA compared to conventional SGA (median: 1 month vs. 3 months, p = 0.002). The likelihood of at least a one-point change is 6.74 times greater in 7-point SGA compared to conventional SGA after controlling for age, gender and medical specialties (odds ratio = 6.74, 95% CI 2.88-15.80, p<0.001). Fifty-six percent of patients who had no change in SGA score had changes detected using 7-point SGA. The level of agreement was 100% (k = 1, p < 0.001) between 7-point SGA and 3-point SGA and 83% (k=0.726, p<0.001) between two blinded assessors for 7-point SGA. Conclusion: The 7-point SGA is more time sensitive in its response to nutrition changes than conventional SGA. It can be used to guide nutrition intervention for patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A restriction analysis of PCR (PCR-REA) amplified apxIVA gene has been suggested as an alternative method for serotyping of Actinobacillus pleuropneumoniae by Jaglic et al. [Jaglic, Z., Svastova, P., Rychlik, I., Nedbalcova, K., Kucerova, Z., Pavlik, I., Bartos, M., 2004. Differentiation of Actinobacillus pleuropneumoniae by PCR-REA based on sequence variability of the apxIVA gene and by ribotyping. Vet. Microbiol. 103, 63-69]. The current study investigated whether this alternative method could distinguish between the reference strains of serovars 13-15 and the value of the method when applied to 47 field isolates representing serovars 1-3, 5, 7-9, 12 and 15 as well as non-typable isolates. The reference strains of serovars 13 and 14 had the same sized product after the apxIVA PCR, while the product for serovar 15 was of different size compared to all the other serovar reference strains. The CfoI digest profiles of the reference serovars 13 and 14 strains were different from each other and from all other serovars. The HpaII digest profiles of these two serovars were very similar to each other, but both were distinctively different from the other serovar profiles. The CfoI digest profile of serovar 15 strain was very similar to the serovars 3 and 12 strains except for two faint extra bands for serovar 15. The HpaII digest profiles of serovars 12 and 15 reference strains were identical. The PCR-REA method correctly recognized the serovar of 21 of 43 field isolates. It was concluded that the method was a useful additional tool to support, but could not replace, conventional serotyping.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The banana industry worldwide is under threat from a fungal disease known as Fusarium wilt, a disease for which there is no chemical control. Conventional breeding approaches to generate resistant banana varieties are lengthy and very difficult. As such, genetic engineering for disease resistance is considered the most viable control option. In this PhD thesis, genetically modified banana plants were generated using several different stress tolerance genes. When challenged with Fusarium wilt in glasshouse trials, some lines showed increased resistance to the disease. The promising elite lines generated in this study will now require testing in field trials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluating the length of time required to dry hardwood timber using vacuum drying compared to conventional drying facilities and technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Drying trials were conducted using two species of plantation grown eucalypt timbers: 19-year-old Eucalyptus cloeziana (Gympie messmate) and 15-year-old Eucalyptus pellita (red mahogany). The objective of this study was to gain an understanding of the drying potential of young plantation grown material using accelerated seasoning methods, a process expected to be critcal to the success of plantation hardwood products entering value added markets. The findings are encouraging, indicating that both species can be dried using conventional drying techniques much faster than industry is currently achieving when drying native forest timber. The results suggest that there is a definite drying time advantatge in vacuum drying over conventional methods for 19-year-old E. cloeziana. The findings have shown that through careful schedule manipulation and adjustment, the grade quality can be optimised to suit the desired expectation. As this study was limited to only a small number of trials, time and quality improvements are expected to be realised for both conventional and vacuum drying methods as more research is conducted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The results of drying trials show that vacuum drying produces material of the same or better quality than is currently being produced by conventional methods within 41 to 66 % of the drying time, depending on the species. Economic analysis indicates positive or negative results depending on the species and the size of drying operation. Definite economic benefits exist by vacuum drying over conventional drying for all operation sizes, in terms of drying quality, time and economic viability, for E. marginata and E. pilularis. The same applies for vacuum drying C. citriodora and E. obliqua in larger drying operations (kiln capacity 50 m3 or above), but not for smaller operations at this stage. Further schedule refinement has the ability to reduce drying times further and may improve the vacuum drying viability of the latter species in smaller operations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to validate a multiplex PCR for the species identification and serotyping of Actinobacillus pleuropneumoniae serovars 1, 5, 7, 12 and 15. All 15 reference strains and 411 field isolates (394 from Australia, 11 from Indonesia, five from Mexico and one from New Zealand) of A. pleuropneumoniae were tested with the multiplex PCR. The specificity of this multiplex PCR was validated on 26 non-A. pleuropneumoniae species. The multiplex PCR gave the expected results with all 15 serovar reference strains and agreed with conventional serotyping for all field isolates from serovars 1 (n = 46), 5 (n = 81), 7 (n = 80), 12 (n = 16) and serovar 15 (n = 117). In addition, a species-specific product was amplified in the multiplex PCR with all 411 A. pleuropneumoniae field isolates. Of 25 nontypeable field isolates only two did not yield a serovar-specific band in the multiplex PCR. This multiplex PCR for serovars 1, 5, 7, 12 and 15 is species specific and capable of serotyping isolates from diverse locations. Significance and Impact of the Study A multiplex PCR that can recognize serovars 1, 5, 7, 12 and 15 of A. pleuropneumoniae was developed and validated. This novel diagnostic tool will enable frontline laboratories to provide key information (the serovar) to guide targeted prevention and control programmes for porcine pleuropneumonia, a serious economic disease of pigs. The previous technology, traditional serotyping, is typically provided by specialized reference laboratories, limiting the capacity to respond to this key disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A randomised and population-based screening design with new technologies has been applied to the organised cervical cancer screening programme in Finland. In this experiment the women invited to routine five-yearly screening are individually randomised to be screened with automation-assisted cytology, human papillomavirus (HPV) test or conventional cytology. By using the randomised design, the ultimate aim is to assess and compare the long-term outcomes of the different screening regimens. The primary aim of the current study was to evaluate, based on the material collected during the implementation phase of the Finnish randomised screening experiment, the cross-sectional performance and validity of automation-assisted cytology (Papnet system) and primary HPV DNA testing (Hybrid Capture II assay for 13 oncogenic HPV types) within service screening, in comparison to conventional cytology. The parameters of interest were test positivity rate, histological detection rate, relative sensitivity, relative specificity and positive predictive value. Also, the effect of variation in performance by screening laboratory on age-adjusted cervical cancer incidence was assessed. Based on the cross-sectional results, almost no differences were observed in the performance of conventional and automation-assisted screening. Instead, primary HPV screening found 58% (95% confidence interval 19-109%) more cervical lesions than conventional screening. However, this was mainly due to overrepresentation of mild- and moderate-grade lesions and, thus, is likely to result in overtreatment since a great deal of these lesions would never progress to invasive cancer. Primary screening with an HPV DNA test alone caused substantial loss in specificity in comparison to cytological screening. With the use of cytology triage test, the specificity of HPV screening improved close to the level of conventional cytology. The specificity of primary HPV screening was also increased by increasing the test positivity cutoff from the level recommended for clinical use, but the increase was more modest than the one gained with the use of cytology triage. The performance of the cervical cancer screening programme varied widely between the screening laboratories, but the variation in overall programme effectiveness between respective populations was more marginal from the very beginning of the organised screening activity. Thus, conclusive interpretations on the quality or success of screening should not be based on performance parameters only. In the evaluation of cervical cancer screening the outcome should be selected as closely as possible to the true measure of programme effectiveness, which is the number of invasive cervical cancers and subsequent deaths prevented in the target population. The evaluation of benefits and adverse effects of each new suggested screening technology should be performed before the technology becomes an accepted routine in the existing screening programme. At best, the evaluation is performed randomised, within the population and screening programme in question, which makes the results directly applicable to routine use.