Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity-modulated and volumetric-modulated arc radiotherapy
Data(s) |
19/11/2013
|
---|---|
Resumo |
Introduction This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across 5 centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity-modulated radiotherapy (IMRT) and 47 treated with volumetric-modulated arc therapy (VMAT). Methods Treatment plan quality was evaluated in terms of target dose homogeneity and organ-at-risk sparing, through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each organ-at-risk. Statistical significance was evaluated using two-tailed Welch’s T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. Results The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the organs-at-risk: with increased compliance with recommended organ-at-risk dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. Conclusions This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT. |
Formato |
application/pdf |
Identificador | |
Publicador |
Wiley Blackwell |
Relação |
http://eprints.qut.edu.au/69111/1/Crowe_-_Evaluation_of_prostate_treatments.pdf DOI:10.1002/jmrs.24 Crowe, Scott, Kairn, Tanya, Middlebrook, Nigel, Hill, Brendan, Christie, David, Knight, Richard, Kenny, John, Langton, Christian M., & Trapp, Jamie (2013) Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity-modulated and volumetric-modulated arc radiotherapy. Journal of Medical Radiation Sciences, 60(4), pp. 131-138. http://purl.org/au-research/grants/ARC/LP110100401 |
Direitos |
Copyright 2013 The Authors. Journal of Medical Radiation Sciences published by Wiley Publishing Asia Pty Ltd on behalf of Australian Institute of Radiography and New Zealand Institute of Medical Radiation Technology This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
Fonte |
School of Chemistry, Physics & Mechanical Engineering; Science & Engineering Faculty |
Palavras-Chave | #029903 Medical Physics #111208 Radiation Therapy #prostate carcinoma #dosimetric quality #intensity-modulated radiotherapy #volumetric-modulated arc therapy #treatment planning |
Tipo |
Journal Article |