899 resultados para Building performance


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The performance assessment as to water consumption in WC cisterns has contributed to the development of flushing system technologies, which allow smaller flushing volumes. The purpose of this work is to assess the performance of the the low water consumption requirement of WC cisterns with dual flushing system (6/3L), when compared to 6L flushing volume WC cisterns in multifamily buildings. The research methodology consisted of a case study in a multifamily residential building with submetering system, by monitoring the total water consumption and the two flushing systems using water meters installed in WC cisterns. By means of a mathematical model, a comparison of the design flowrate in the main branch was carried out considering the two types of WC cisterns. The results indicated that the water consumption in the 6L WC cistern was 20% in relation to the total domestic consumption, whereas the water consumption observed in the dual-flush WC cistern (6/3L) was 16%. The dual flushing system (6/3L) presented about 18% consumption reduction impact as compared to the 6 L system. The design flowrate values in the main branch, obtained by the mathematical model, were 0.35 L/s for systems with 6 L WC cistern and 0.34 L/s with dual-flush WC cistern (6/3 L), that is, a reduction of similar to 3%. Practical application: The knowledge of the performance in field of dual-flush WC cistern contributes to industry to improve this system and to users to aid their choice of technologies aimed at water conservation, and so assisting to the development of sustainable buildings.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tutkimuksen tavoite oli selvittää yrityksen web toiminnan rakentamisen vaiheita sekä menestyksen mittaamista. Rakennusprosessia tutkittiin viisiportaisen askelmallin avulla. Mallin askeleet ovat; arviointi, strategian muotoilu, suunnitelma, pohjapiirros ja toteutus. Arviointi- ja toteutusvaiheiden täydentämiseksi sekä erityisesti myös internet toiminnan onnistumisen mittaamisen avuksi internet toiminnan hyödyt (CRM,kommunikointi-, myynti-, ja jakelukanava hyödyt markkinoinnin kannalta) käsiteltiin. Toiminnan menestyksen arvioinnin avuksi esiteltiin myös porrasmalli internet toimintaan. Porrasmalli määrittelee kauppakulissi-, dynaaminen-, transaktio- ja e-businessportaat. Tutkimuksessa löydettiin menestystekijöitä internet toimintojen menestykselle. Nämä tekijät ovat laadukas sisältö, kiinnostavuus, viihdyttävyys, informatiivisuus, ajankohtaisuus, personoitavuus, luottamus, interaktiivisuus, käytettävyys, kätevyys, lojaalisuus, suoriutuminen, responssiivisuus ja käyttäjätiedon kerääminen. Mittarit jaettiin tutkimuksessa aktiivisuus-, käyttäytymis- ja muunnosmittareihin. Lisäksi muita mittareita ja menestysindikaattoreita esiteltiin. Nämä menestyksen elementit ja mittarit koottiin yhteen uudessa internet toimintojen menestyksenarviointimallissa. Tutkielman empiirisessä osuudessa,esitettyjä teorioita peilattiin ABB:n (ABB:n sisällä erityisesti ABB Stotz-Kontakt) web toimintaan. Apuna olivat dokumenttianalyysi sekä haastattelut. Empiirinen osa havainnollisti teoriat käytännössä ja toi ilmi mahdollisuuden teorioiden laajentamiseen. Internet toimintojen rakentamismallia voidaan käyttää myös web toimintojen kehittämiseen ja porrasmalli sopii myös nykyisten internet toimintojen arvioimiseen. Mittareiden soveltaminen käytännössä toi kuitenkin ilmi tarpeen niiden kehittämiseen ja aiheen lisätutkimukseen. Niiden tulisi olla myös aiempaatiiviimmin liitetty kokonaisvaltaisen liiketoiminnan menestyksen mittaamiseen.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An exchange traded fund (ETF) is a financial instrument that tracks some predetermined index. Since their initial establishment in 1993, ETFs have grown in importance in the field of passive investing. The main reason for the growth of the ETF industry is that ETFs combine benefits of stock investing and mutual fund investing. Although ETFs resemble mutual funds in many ways, also many differences occur. In addition, ETFs not only differ from mutual funds but also differ among each other. ETFs can be divided into two categories, i.e. market capitalisation ETFs and fundamental (or strategic) ETFs, and further into subcategories depending on their fundament basis. ETFs are a useful tool for diversification especially for a long-term investor. Although the economic importance of ETFs has risen drastically during the past 25 years, the differences and risk-return characteristics of fundamental ETFs have yet been rather unstudied area. In effect, no previous research on market capitalisation and fundamental ETFs was found during the research process. For its part, this thesis seeks to fill this research gap. The studied data consist of 50 market capitalisation ETFs and 50 fundamental ETFs. The fundaments, on which the indices that the fundamental ETFs track, were not limited nor segregated into subsections. The two types of ETFs were studied at an aggregate level as two different research groups. The dataset ranges from June 2006 to December 2014 with 103 monthly observations. The data was gathered using Bloomberg Terminal. The analysis was conducted as an econometric performance analysis. In addition to other econometric measures, the methods that were used in the performance analysis included modified Value-at-Risk, modified Sharpe ratio and Treynor ratio. The results supported the hypothesis that passive market capitalisation ETFs outperform active fundamental ETFs in terms of risk-adjusted returns, though the difference is rather small. Nevertheless, when taking into account the higher overall trading costs of the fundamental ETFs, the underperformance gap widens. According to the research results, market capitalisation ETFs are a recommendable diversification instrument for a long-term investor. In addition to better risk-adjusted returns, passive ETFs are more transparent and the bases of their underlying indices are simpler than those of fundamental ETFs. ETFs are still a young financial innovation and hence data is scarcely available. On future research, it would be valuable to research the differences in risk-adjusted returns also between the subsections of fundamental ETFs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A wind catcher/tower natural ventilation system was installed in a seminar room in the building of the School of Construction Management and Engineering, the University of Reading in the UK . Performance was analysed by means of ventilation tracer gas measurements, indoor climate measurements (temperature, humidity, CO2) and occupant surveys. In addition, the potential of simple design tools was evaluated by comparing observed ventilation results with those predicted by an explicit ventilation model and the AIDA implicit ventilation model. To support this analysis, external climate parameters (wind speed and direction, solar radiation, external temperature and humidity) were also monitored. The results showed the chosen ventilation design provided a substantially greater ventilation rate than an equivalent area of openable window. Also air quality parameters stayed within accepted norms while occupants expressed general satisfaction with the system and with comfort conditions. Night cooling was maximised by using the system in combination with openable windows. Comparisons of calculations with ventilation rate measurements showed that while AIDA gave reasonably correlated results with the monitored performance results, the widely used industry explicit model was found to over estimate the monitored ventilation rate.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A case study on the tendering process and cost/time performance of a public building project in Ghana is conducted. Competitive bids submitted by five contractors for the project, in which contractors were required to prepare their own quantities, were analyzed to compare differences in their pricing levels and risk/requirement perceptions. Queries sent to the consultants at the tender stage were also analyzed to identify the significant areas of concern to contractors in relation to the tender documentation. The five bidding prices were significantly different. The queries submitted for clarifications were significantly different, although a few were similar. Using a before-and-after experiment, the expected cost/time estimate at the start of the project was compared to the actual cost/time values, i.e. what happened in the actual construction phase. The analysis showed that the project exceeded its expected cost by 18% and its planned time by 210%. Variations and inadequate design were the major reasons. Following an exploration of these issues, an alternative tendering mechanism is recommended to clients. A shift away from the conventional approach of awarding work based on price, and serious consideration of alternative procurement routes can help clients in Ghana obtain better value for money on their projects.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study presents the findings of applying a Discrete Demand Side Control (DDSC) approach to the space heating of two case study buildings. High and low tolerance scenarios are implemented on the space heating controller to assess the impact of DDSC upon buildings with different thermal capacitances, light-weight and heavy-weight construction. Space heating is provided by an electric heat pump powered from a wind turbine, with a back-up electrical network connection in the event of insufficient wind being available when a demand occurs. Findings highlight that thermal comfort is maintained within an acceptable range while the DDSC controller maintains the demand/supply balance. Whilst it is noted that energy demand increases slightly, as this is mostly supplied from the wind turbine, this is of little significance and hence a reduction in operating costs and carbon emissions is still attained.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Existing buildings contribute greatly to global energy use and greenhouse gas emissions. In the UK, about 18% of carbon emissions are generated by non-domestic buildings; sustainable building refurbishment can play an important role in reducing carbon emissions. This paper looks at the performance of a recently refurbished 5-storey office building in London, in terms of energy consumption as well as occupants’ satisfaction. Pre- and post-occupancy evaluation studies were conducted using online questionnaire surveys and energy consumption evaluation. Results from pre-occupancy and post-occupancy evaluation studies showed that employees, in general, were more satisfied with their work environment at the refurbished building than with that of their previous office. Employees’ self-reported productivity improved after the move to Elms House. These surveys showed a positive relationship between employees’ satisfaction with their work environment and their self-reported productivity, well-being and enjoyment at work. The factor that contributed to increasing employee satisfaction the most was: better use of interior space. Although the refurbishment was a success in terms of reducing energy consumption per m2, the performance gap was almost 3 times greater than that estimated. Unregulated loads, problems with building control, ineffective use of space and occupants’ behaviour are argued to be reasons for this gap.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this study, the performance, yield and characteristics of a 15 year old photovoltaic system installation has been investigated. The technology, BP Saturn modules which were steel-blue polycrystalline silicon cells are no longer in production. A bespoke monitoring system was designed and purpose built to monitor the characteristics of 6 strings, of 18 modules connected in series. The total output of the system is configured to 6.5kWp (series to parallel configuration). The PV system is demonstrating system outputs to be inferior by 0.7% per year. However,efficiency values in comparison to standard test conditions have remained practically the same. This output though very relevant to the possible performance and stability of aging cells, requires additional parametric studies to develop a more robust argument. The result presented in this paper is part of an on going investigation into PV system aging effects.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this study, the performance, yield and characteristics of a 16 year old photovoltaic (PV) system installation have been investigated. The technology, BP Saturn modules which were steel-blue polycrystalline silicon cells are no longer in production. A bespoke monitoring system has been designed to monitor the characteristics of 6 refurbished strings, of 18 modules connected in series. The total output of the system is configured to 6.5 kWp (series to parallel configuration). In addition to experimental results, the performance ratio (PR) of known values was simulated using PVSyst, a simulation software package. From calculations using experimental values, the PV system showed approximately 10% inferior power outputs to what would have been expected as standard test conditions. However, efficiency values in comparison to standard test conditions and the performance ratio (w75% from PVSyst simulations) over the past decade have remained practically the same. This output though very relevant to the possible performance and stability of aging cells, requires additional parametric studies to develop a more robust argument. The result presented in this paper is part of an on-going investigation into PV system aging effects.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cool materials are characterized by having a high solar reflectance r – which is able to reduce heat gains during daytime - and a high thermal emissivity ε that enables them to dissipate the heat absorbed throughout the day during night. Despite the concept of cool roofs - i.e. the application of cool materials to roof surfaces - is well known in US since 1990s, many studies focused on their performance in both residential and commercial sectors under various climatic conditions for US countries, while only a few case studies are analyzed in EU countries. The present work aims at analyzing the thermal benefits due to their application to existing office buildings located in EU countries. Indeed, due to their weight in the existing buildings stock, as well as the very low rate of new buildings construction, the retrofit of office buildings is a topic of great concern worldwide. After an in-depth characterization of the existing buildings stock in the EU, the book gives an insight into roof energy balance due to different technological solutions, showing in which cases and to what extent cool roofs are preferable. A detailed description of the physical properties of cool materials and their availability on the market provides a solid background for the parametric analysis carried out by means of detailed numerical models that aims at evaluating cool roofs performance for various climates and office buildings configurations. With the help of dynamic simulations, the thermal behavior of representative office buildings of the existing EU buildings stock is assessed in terms of thermal comfort and energy needs for air conditioning. The results, which consider several variations of building features that may affect the resulting energy balance, show how cool roofs are an effective strategy for reducing overheating occurrences and thus improving thermal comfort in any climate. On the other hand, potential heating penalties due to a reduction in the incoming heat fluxes through the roof are taken into account, as well as the aging process of cool materials. Finally, an economic analysis of the best performing models shows the boundaries for their economic convenience.