Performance of a BP c-Si building Integrated PV system after 15years of installation


Autoria(s): Essah, Emmanuel; Glover, Neil; Rodriguez Arguelles, Ana
Data(s)

24/10/2013

Resumo

In this study, the performance, yield and characteristics of a 15 year old photovoltaic system installation has been investigated. The technology, BP Saturn modules which were steel-blue polycrystalline silicon cells are no longer in production. A bespoke monitoring system was designed and purpose built to monitor the characteristics of 6 strings, of 18 modules connected in series. The total output of the system is configured to 6.5kWp (series to parallel configuration). The PV system is demonstrating system outputs to be inferior by 0.7% per year. However,efficiency values in comparison to standard test conditions have remained practically the same. This output though very relevant to the possible performance and stability of aging cells, requires additional parametric studies to develop a more robust argument. The result presented in this paper is part of an on going investigation into PV system aging effects.

Formato

text

Identificador

http://centaur.reading.ac.uk/35145/1/SUDBE-2013%20Emmanuel%20Essah.pdf

Essah, E. <http://centaur.reading.ac.uk/view/creators/90001164.html>, Glover, N. and Rodriguez Arguelles, A. (2013) Performance of a BP c-Si building Integrated PV system after 15years of installation. In: International Conference of SuDBE2013, 25-28 Oct 2013, Chongqing, China.

Idioma(s)

en

Relação

http://centaur.reading.ac.uk/35145/

creatorInternal Essah, Emmanuel

Tipo

Conference or Workshop Item

PeerReviewed